{"id":743,"date":"2026-01-21T01:54:08","date_gmt":"2026-01-21T01:54:08","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=743"},"modified":"2026-05-19T07:28:56","modified_gmt":"2026-05-19T07:28:56","slug":"iso-9626","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/tr\/standards\/iso-9626","title":{"rendered":"ISO 9626"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"743\" class=\"elementor elementor-743\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f874d59 e-flex e-con-boxed e-con e-parent\" data-id=\"f874d59\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bd174fc elementor-widget elementor-widget-heading\" data-id=\"bd174fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 9626<br><small>T\u0131bbi Cihazlar i\u00e7in \u0130\u011fne Hortumu Sertlik Testi ve Diren\u00e7 Testi<\/small><\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e540d6b elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"e540d6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong data-start=\"525\" data-end=\"537\">ISO 9626<\/strong> hipodermik i\u011fneler gibi t\u0131bbi cihazlarda kullan\u0131lan paslanmaz \u00e7elik i\u011fne borular\u0131n\u0131n test edilmesine y\u00f6nelik kritik k\u0131lavuz ilkeler sunmaktad\u0131r. Bu testler, a\u015fa\u011f\u0131dakileri i\u00e7erir <a href=\"https:\/\/www.syringetest.com\/tr\/needle-tubing-stiffness-test\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"689\" data-end=\"721\">i\u011fne hortumu sertlik testi<\/strong><\/a> ve k\u0131r\u0131lma direnci, hortumun \u00e7e\u015fitli ko\u015fullar alt\u0131nda mekanik b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc korumas\u0131n\u0131 sa\u011flayarak t\u0131bbi cihazlar\u0131n g\u00fcvenli\u011fine ve etkinli\u011fine katk\u0131da bulunur. Bu makale a\u015fa\u011f\u0131dakilerin temel y\u00f6nlerini a\u00e7\u0131klamaktad\u0131r <strong data-start=\"933\" data-end=\"945\">ISO 9626<\/strong>, the <strong data-start=\"951\" data-end=\"983\">i\u011fne hortumu sertlik testi<\/strong>, ve a\u015fa\u011f\u0131daki gibi ilgili testler <strong data-start=\"1011\" data-end=\"1035\">korozyon di\u0307renci\u0307<\/strong> ve <strong data-start=\"1040\" data-end=\"1077\">i\u011fne hortumu k\u0131r\u0131lma direnci<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b53c62 e-flex e-con-boxed e-con e-parent\" data-id=\"7b53c62\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a6b3275 elementor-widget elementor-widget-heading\" data-id=\"a6b3275\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0130\u011fneli Boru Testlerinde ISO 9626'n\u0131n \u00d6nemi<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9be5caa elementor-widget elementor-widget-text-editor\" data-id=\"9be5caa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1141\" data-end=\"1609\"><strong data-start=\"1141\" data-end=\"1158\">ISO 9626:2016<\/strong> i\u00e7in gereklilikleri belirtir <strong data-start=\"1190\" data-end=\"1229\">sert paslanmaz \u00e7elik i\u011fne hortumu<\/strong> ba\u015fta insan kullan\u0131m\u0131 i\u00e7in olmak \u00fczere t\u0131bbi cihazlar\u0131n \u00fcretiminde kullan\u0131l\u0131r. Standart, a\u015fa\u011f\u0131dakiler aras\u0131nda de\u011fi\u015fen \u00e7e\u015fitli metrik boyutlardaki borular i\u00e7in ge\u00e7erlidir <strong data-start=\"1367\" data-end=\"1388\">3,4 mm (10 Gauge)<\/strong> i\u00e7in <strong data-start=\"1392\" data-end=\"1414\">0,18 mm (34 Gauge)<\/strong>. A\u015fa\u011f\u0131dakiler gibi mekanik \u00f6zellikleri kapsar <strong data-start=\"1456\" data-end=\"1483\">i\u011fne hortumu sertli\u011fi<\/strong>, T\u0131bbi cihazlar\u0131n g\u00fcvenli\u011fini ve g\u00fcvenilirli\u011fini sa\u011flamak i\u00e7in \u00e7ok \u00f6nemli olan k\u0131r\u0131lma direnci ve korozyon direnci.<\/p><p data-start=\"1611\" data-end=\"1904\">ISO 9626, a\u015fa\u011f\u0131dakiler dahil olmak \u00fczere i\u011fne hortumunun fiziksel \u00f6zelliklerini belirlemeye y\u00f6nelik test y\u00f6ntemlerini ana hatlar\u0131yla belirtir <strong data-start=\"1717\" data-end=\"1737\">\u00c7ekme Dayan\u0131m\u0131<\/strong>, <strong data-start=\"1739\" data-end=\"1752\">sertlik<\/strong>ve <strong data-start=\"1758\" data-end=\"1781\">k\u0131r\u0131lma direnci<\/strong>. Bu testler, \u00fcreticilerin end\u00fcstri standartlar\u0131na uymas\u0131 ve y\u00fcksek kaliteli, dayan\u0131kl\u0131 \u00fcr\u00fcnler sunmas\u0131 i\u00e7in gereklidir.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-358c421 e-flex e-con-boxed e-con e-parent\" data-id=\"358c421\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ebed27b elementor-widget elementor-widget-heading\" data-id=\"ebed27b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 9626'ya G\u00f6re \u0130\u011fne Boru Sertlik Testi<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a74594e e-con-full e-flex e-con e-child\" data-id=\"a74594e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-370bb8f elementor-widget elementor-widget-text-editor\" data-id=\"370bb8f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1844\" data-end=\"2038\">Bu <strong data-start=\"1970\" data-end=\"2002\">i\u011fne hortumu sertlik testi<\/strong> ISO 9626'n\u0131n ayr\u0131lmaz bir par\u00e7as\u0131d\u0131r. Bu test, borunun kuvvet alt\u0131nda b\u00fck\u00fclmeye direnme kabiliyetini de\u011ferlendirir. Testi ger\u00e7ekle\u015ftirmek i\u00e7in, her iki ucundan desteklenen belirli bir boru uzunlu\u011funun merkezine belirli bir kuvvet uygulan\u0131r. Daha sonra sapma miktar\u0131 \u00f6l\u00e7\u00fcl\u00fcr.<\/p><h3>Sertlik Testi i\u00e7in Ekipman<\/h3><p data-start=\"2321\" data-end=\"2655\">Sertlik testi i\u00e7in bir <strong data-start=\"2351\" data-end=\"2382\">sertlik test aparat\u0131<\/strong> kadar a\u015fa\u011f\u0131 do\u011fru kuvvet uygulayabilen <strong data-start=\"2429\" data-end=\"2437\">60 N<\/strong>. Bu aparat, alt k\u0131sm\u0131nda k\u00f6r bir kama bulunan bir pistona sahip olmal\u0131 ve uygulanan kuvvet a\u015fa\u011f\u0131daki hassasiyetle \u00f6l\u00e7\u00fclmelidir <strong data-start=\"2568\" data-end=\"2578\">\u00b10.1 N<\/strong>. Borunun sapmas\u0131 en yak\u0131n \u00f6l\u00e7\u00fcye g\u00f6re \u00f6l\u00e7\u00fclmelidir <strong data-start=\"2643\" data-end=\"2654\">0.01 mm<\/strong>.<\/p><p data-start=\"2657\" data-end=\"2958\">Test, bir i\u011fnenin hortumunun kullan\u0131m s\u0131ras\u0131nda nas\u0131l performans g\u00f6sterece\u011fini anlamak i\u00e7in \u00f6nemli veriler sa\u011flar. <strong data-start=\"2769\" data-end=\"2784\">esneklik<\/strong> ve d\u0131\u015f kuvvetlere ar\u0131zalanmadan dayanma kabiliyeti. \u00dcreticiler a\u015fa\u011f\u0131dakilere g\u00fcvenir <strong data-start=\"2869\" data-end=\"2887\">sertlik testi<\/strong> \u00fcr\u00fcnlerinin gerekli mekanik standartlar\u0131 kar\u015f\u0131lad\u0131\u011f\u0131ndan emin olmak i\u00e7in.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9f5ae8e elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"9f5ae8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance.webp\" class=\"attachment-large size-large wp-image-749\" alt=\"ISO 9626 \u0130\u011fneli Boru Sertlik Testi ve K\u0131r\u0131lma Direnci\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-300x300.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-150x150.webp 150w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">\u0130\u011fne Boru Sertlik Testi ve K\u0131r\u0131lma Direnci<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f25e92e elementor-widget elementor-widget-text-editor\" data-id=\"f25e92e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>\u0130\u011fne Hortumu K\u0131r\u0131lma Direnci: Dayan\u0131kl\u0131l\u0131\u011f\u0131n Sa\u011flanmas\u0131<\/h3><p data-start=\"3024\" data-end=\"3310\">'de belirtilen bir di\u011fer \u00f6nemli test <strong data-start=\"3054\" data-end=\"3066\">ISO 9626<\/strong> bu <a href=\"https:\/\/www.syringetest.com\/tr\/needle-tubing-breakage-resistance-test\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"3074\" data-end=\"3116\">i\u011fne hortumu k\u0131r\u0131lma direnci testi<\/strong>.<\/a> Bu test, i\u011fnenin yerle\u015ftirme s\u0131ras\u0131nda strese maruz kalabilece\u011fi uygulamalarda kritik \u00f6neme sahip olan i\u011fne hortumunun k\u0131r\u0131lmadan tekrarlanan b\u00fck\u00fclmelere dayanma kabiliyetini de\u011ferlendirir.<\/p><p data-start=\"3312\" data-end=\"3664\">Test, boruya bir kuvvet uygulanmas\u0131n\u0131, belirli bir a\u00e7\u0131 boyunca b\u00fck\u00fclmesini ve b\u00fckme d\u00f6ng\u00fclerinin tekrarlanmas\u0131n\u0131 i\u00e7erir. Boru a\u015fa\u011f\u0131dakilere dayanmal\u0131d\u0131r <strong data-start=\"3459\" data-end=\"3472\">20 d\u00f6ng\u00fc<\/strong> k\u0131r\u0131lmadan her iki y\u00f6nde de b\u00fck\u00fclebilir. Bu test, hortumun rutin kullan\u0131m s\u0131ras\u0131nda kar\u015f\u0131la\u015fabilece\u011fi kuvvetleri sim\u00fcle eder ve i\u011fnenin normal ko\u015fullar alt\u0131nda ar\u0131zalanmamas\u0131n\u0131 sa\u011flar<\/p><h3 data-start=\"3719\" data-end=\"4048\">\u0130\u011fneli Boru i\u00e7in Korozyon Direnci Testi<\/h3><p data-start=\"3719\" data-end=\"4048\">Bu <strong data-start=\"3723\" data-end=\"3747\">korozyon di\u0307renci\u0307<\/strong> \u00f6zellikle \u00e7e\u015fitli kimyasallara ve sterilizasyon i\u015flemlerine maruz kalan t\u0131bbi cihazlar i\u00e7in bir di\u011fer \u00f6nemli \u00f6zelliktir. ISO 9626, hortumu bir kimyasal\u0131n i\u00e7ine dald\u0131rarak korozyon direncini test etmek i\u00e7in bir y\u00f6ntemin ana hatlar\u0131n\u0131 \u00e7izmektedir. <strong data-start=\"3974\" data-end=\"4002\">sodyum klor\u00fcr \u00e7\u00f6zeltisi<\/strong> ve belirli bir s\u00fcre sonra etkilerin g\u00f6zlemlenmesi.<\/p><p data-start=\"4050\" data-end=\"4434\">Test, hortumun bir t\u00fcpe dald\u0131r\u0131lmas\u0131n\u0131 i\u00e7erir. <strong data-start=\"4094\" data-end=\"4132\">0,5 mol\/l sodyum klor\u00fcr \u00e7\u00f6zeltisi<\/strong> at <strong data-start=\"4136\" data-end=\"4148\">23 \u00b1 2\u00b0C<\/strong> i\u00e7in <strong data-start=\"4153\" data-end=\"4164\">7 saat<\/strong>. Dald\u0131rma s\u00fcresinden sonra, hortum herhangi bir korozyon belirtisi a\u00e7\u0131s\u0131ndan incelenir. Korozyon direnci, \u00f6zellikle salin sol\u00fcsyonlar\u0131na veya sterilizasyon maddelerine maruz kald\u0131\u011f\u0131 ortamlarda i\u011fne hortumunun uzun \u00f6m\u00fcrl\u00fc olmas\u0131n\u0131 ve b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc sa\u011flamak i\u00e7in gereklidir.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-196f14b e-flex e-con-boxed e-con e-parent\" data-id=\"196f14b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-aeb9a58 elementor-widget elementor-widget-heading\" data-id=\"aeb9a58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Do\u011fru \u015e\u0131r\u0131nga Test Ekipman\u0131n\u0131n Se\u00e7ilmesi<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b66d85 e-grid e-con-full e-con e-child\" data-id=\"1b66d85\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8e5c175 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"8e5c175\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-1.webp\" class=\"attachment-full size-full wp-image-750\" alt=\"ISO 9626 \u0130\u011fne Boru Sertlik Testi ve K\u0131r\u0131lma Direnci 1\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-1.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-1-300x300.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-1-150x150.webp 150w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-1-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">TS-01 Boru Sertlik Test Cihaz\u0131<\/h3><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d0d80d4 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"d0d80d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-2.webp\" class=\"attachment-full size-full wp-image-751\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-2.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-2-300x300.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-2-150x150.webp 150w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-2-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">MST-01 T\u0131bbi \u015e\u0131r\u0131nga Test Cihaz\u0131<\/h3><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-546e5c0 e-flex e-con-boxed e-con e-parent\" data-id=\"546e5c0\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9bd6bef elementor-widget elementor-widget-heading\" data-id=\"9bd6bef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u015e\u0131r\u0131nga T\u00fcp\u00fc Sertlik Test Cihaz\u0131n\u0131n Rol\u00fc<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b983f6 elementor-widget elementor-widget-text-editor\" data-id=\"7b983f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4491\" data-end=\"4950\">Do\u011fru bir \u015fekilde y\u00fcr\u00fctmek i\u00e7in <strong data-start=\"4511\" data-end=\"4544\">i\u011fne hortumu sertlik testleri<\/strong>, do\u011fru ekipman\u0131 kullanmak \u00e7ok \u00f6nemlidir. Bu <strong data-start=\"4596\" data-end=\"4629\">\u015e\u0131r\u0131nga T\u00fcp\u00fc Sertlik Test Cihaz\u0131<\/strong> \u00f6l\u00e7mek i\u00e7in tasarlanm\u0131\u015ft\u0131r. <strong data-start=\"4657\" data-end=\"4679\">e\u011filme direnci<\/strong> \u00dcr\u00fcn\u00fcn t\u0131bbi uygulamalarda kullan\u0131m i\u00e7in gerekli standartlar\u0131 kar\u015f\u0131lamas\u0131n\u0131 sa\u011flar. Bu cihaz, de\u011fi\u015fen y\u00fckler alt\u0131nda hortumun sapmas\u0131n\u0131 \u00f6l\u00e7ebilir ve \u00fcreticilerin hortumun kalitesini de\u011ferlendirmesine ve dayan\u0131kl\u0131l\u0131\u011f\u0131n\u0131 sa\u011flamas\u0131na olanak tan\u0131r.<\/p><p data-start=\"4952\" data-end=\"5261\">\u015e\u0131r\u0131nga T\u00fcp\u00fc Sertlik Test Cihaz\u0131 son derece hassast\u0131r ve \u00fcreticilerin a\u015fa\u011f\u0131dakilere uygunlu\u011fu sa\u011flamalar\u0131 i\u00e7in g\u00fcvenilir veriler sa\u011flar <strong data-start=\"5076\" data-end=\"5088\">ISO 9626<\/strong> standartlar\u0131. Bu ekipman\u0131n kullan\u0131lmas\u0131, i\u011fne hortumunun kullan\u0131m s\u0131ras\u0131nda \u015feklini ve b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc koruyacak kadar sert, ancak kolayca yerle\u015ftirilebilecek kadar esnek olmas\u0131n\u0131 garanti etmeye yard\u0131mc\u0131 olur.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1e2088e e-grid e-con-full e-con e-parent\" data-id=\"1e2088e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c84e9d5 elementor-widget elementor-widget-image\" data-id=\"c84e9d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2db946f e-con-full e-flex e-con e-child\" data-id=\"2db946f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8a85f93 elementor-widget elementor-widget-heading\" data-id=\"8a85f93\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Neden Se\u00e7melisiniz <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b4a49d elementor-widget elementor-widget-text-editor\" data-id=\"6b4a49d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4917\" data-end=\"5240\">Takip ederek <strong data-start=\"6439\" data-end=\"6451\">ISO 9626<\/strong> ve uygun test ekipmanlar\u0131n\u0131 kullanarak, \u00fcreticiler hastalar\u0131n g\u00fcvenli\u011fini ve t\u0131bbi cihazlar\u0131n etkinli\u011fini sa\u011flayan dayan\u0131kl\u0131 ve y\u00fcksek kaliteli i\u011fne hortumlar\u0131 \u00fcretebilirler.<\/p><p data-start=\"5242\" data-end=\"5537\"><strong>Syringetest.com<\/strong> geli\u015fmi\u015f sa\u011flar <strong data-start=\"5281\" data-end=\"5310\">\u015f\u0131r\u0131nga test ekipmanlar\u0131<\/strong> tam uyumlulu\u011fu ve kolayla\u015ft\u0131r\u0131lm\u0131\u015f QC i\u015f ak\u0131\u015flar\u0131n\u0131 desteklemek i\u00e7in tasarlanm\u0131\u015ft\u0131r. \u015e\u0131r\u0131nga do\u011frulama s\u00fcrecinizi y\u00fckseltmek veya test do\u011frulu\u011funu art\u0131rmak istiyorsan\u0131z, cihazlar\u0131m\u0131z\u0131n standartlar\u0131n\u0131z\u0131 kar\u015f\u0131laman\u0131za nas\u0131l yard\u0131mc\u0131 olabilece\u011fini \u00f6\u011frenmek i\u00e7in bizimle ileti\u015fime ge\u00e7in.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68036d0 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"68036d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/tr\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Bize Ula\u015f\u0131n<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 9626Needle Tubing Stiffness Test and Resistance Testing for Medical Devices ISO 9626 provides critical guidelines for testing stainless steel needle tubing used in medical devices, such as hypodermic needles. These tests, including the needle tubing stiffness test and breakage resistance, ensure that the tubing maintains mechanical integrity under various conditions, contributing to the safety [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":603,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-743","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/pages\/743","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/comments?post=743"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/pages\/743\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/pages\/603"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/media?parent=743"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}