{"id":154,"date":"2025-04-30T01:31:34","date_gmt":"2025-04-30T01:31:34","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=154"},"modified":"2026-05-09T06:36:31","modified_gmt":"2026-05-09T06:36:31","slug":"finger-flange-breakage-force-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/tr\/finger-flange-breakage-force-test","title":{"rendered":"Parmak Flan\u015f\u0131 K\u0131r\u0131lma Kuvveti Testi"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"154\" class=\"elementor elementor-154\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-247db7c e-flex e-con-boxed e-con e-parent\" data-id=\"247db7c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab06118 elementor-widget elementor-widget-heading\" data-id=\"ab06118\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Parmak Flan\u015f\u0131 K\u0131r\u0131lma Kuvveti Testi<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62cf733 elementor-widget elementor-widget-text-editor\" data-id=\"62cf733\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u0130la\u00e7 ve t\u0131bbi ambalaj end\u00fcstrisinde, <strong>parmak flan\u015f\u0131 k\u0131r\u0131lma kuvveti<\/strong> \u015f\u0131r\u0131nga kovanlar\u0131n\u0131n yap\u0131sal g\u00fcvenilirli\u011fini sa\u011flamak i\u00e7in kritik bir performans g\u00f6stergesidir. Bu parametre \u015fu \u015fekilde tan\u0131mlanm\u0131\u015f ve standartla\u015ft\u0131r\u0131lm\u0131\u015ft\u0131r <strong><em><a href=\"https:\/\/www.syringetest.com\/tr\/standards\/iso-11040-4\/\">ISO 11040-4<\/a> Ek C1<\/em><\/strong>\u00fcreticilerin ve kalite g\u00fcvence uzmanlar\u0131n\u0131n \u015f\u0131r\u0131nga flan\u015f\u0131n\u0131n ta\u015f\u0131ma ve enjeksiyon s\u0131ras\u0131nda mekanik gerilime dayan\u0131p dayanamayaca\u011f\u0131n\u0131 de\u011ferlendirmelerine yard\u0131mc\u0131 olur.<\/p><p>Bu \u00f6l\u00e7\u00fcm\u00fc ve standart test y\u00f6ntemini anlamak, a\u015fa\u011f\u0131dakilerle ilgilenen profesyoneller i\u00e7in hayati \u00f6nem ta\u015f\u0131r <strong>\u015f\u0131r\u0131nga testi<\/strong>\u00f6zellikle enjekte edilebilir \u00e7\u00f6zeltiler i\u00e7in tasarlanm\u0131\u015f steril alt montajl\u0131 \u015f\u0131r\u0131ngalar i\u00e7in.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f136d2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f136d2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b673494 elementor-widget elementor-widget-heading\" data-id=\"b673494\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u015e\u0131r\u0131nga B\u00fct\u00fcnl\u00fc\u011f\u00fcnde Parmak Flan\u015f\u0131 K\u0131r\u0131lma Kuvvetinin \u00d6nemi<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa819a0 elementor-widget elementor-widget-text-editor\" data-id=\"aa819a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bu <strong>parmak flan\u015f\u0131 k\u0131r\u0131lma kuvveti<\/strong> bir \u015f\u0131r\u0131ngan\u0131n flan\u015f\u0131n\u0131n ar\u0131zalanmadan \u00f6nce dayanabilece\u011fi maksimum mekanik kuvveti ifade eder. Bu de\u011fer, \u00f6zellikle kullan\u0131c\u0131lar enjeksiyon s\u0131ras\u0131nda bas\u0131n\u00e7 uygulad\u0131\u011f\u0131nda veya otomatik dolum sistemleri \u015f\u0131r\u0131ngay\u0131 kavrad\u0131\u011f\u0131nda \u015f\u0131r\u0131ngan\u0131n sa\u011flaml\u0131\u011f\u0131n\u0131 g\u00f6sterir.<\/p><p>Yetersiz bir k\u0131r\u0131lma kuvveti, flan\u015f \u00e7atlaklar\u0131na veya tamamen ar\u0131zaya neden olarak g\u00fcvenlik tehlikesi olu\u015fturabilir. Bu nedenle, t\u0131bbi cihaz \u00fcretiminde partiler aras\u0131nda tutarl\u0131 kalitenin korunmas\u0131 tart\u0131\u015f\u0131lmazd\u0131r.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-37feff9 e-flex e-con-boxed e-con e-parent\" data-id=\"37feff9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3146496 elementor-widget elementor-widget-heading\" data-id=\"3146496\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Parmak Flan\u015f\u0131 K\u0131r\u0131lma Kuvveti Testi - ISO 11040-4 Ek C1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08fc359 elementor-widget elementor-widget-text-editor\" data-id=\"08fc359\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bu <strong><a href=\"https:\/\/www.syringetest.com\/tr\/standards\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">ISO 11040-4<\/a> Ek C1<\/strong> flan\u015f k\u0131r\u0131lma direncini de\u011ferlendirmek i\u00e7in test y\u00f6ntemini \u00f6zetlemektedir. Prosed\u00fcr do\u011fru, tekrarlanabilir sonu\u00e7lar sa\u011flar ve \u015f\u0131r\u0131nga performans testinde alt\u0131n standart haline getirir.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd10895 e-grid e-con-full e-con e-child\" data-id=\"fd10895\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d98b842 elementor-widget elementor-widget-text-editor\" data-id=\"d98b842\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Test Hedefi<\/h3><p>\u00d6zel ekipman kullanarak \u015f\u0131r\u0131nga kovan\u0131na a\u015fa\u011f\u0131 do\u011fru bir kuvvet uygulayarak flan\u015f k\u0131r\u0131lma direncini belirlemek. Bu test her iki flan\u015f\u0131 da de\u011ferlendirir <strong>cam varil mukavemeti<\/strong> ve \u015f\u0131r\u0131nga tasar\u0131m\u0131n\u0131n geri kalan\u0131yla uyumlulu\u011fu.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db58dbc elementor-widget elementor-widget-text-editor\" data-id=\"db58dbc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Gerekli Ekipman<\/h3><ul><li><strong>\u00dcniversal \u00e7ekme ve basma test cihaz\u0131<\/strong>: Uygun bir y\u00fck h\u00fccresi ve yap\u0131land\u0131r\u0131labilir bir test h\u0131z\u0131 i\u00e7ermelidir. <strong>100 mm\/dak<\/strong>.<\/li><li><strong>\u015e\u0131r\u0131nga tutucu<\/strong>: Tipik olarak PEEK'ten yap\u0131l\u0131r, \u015f\u0131r\u0131nga boyutlar\u0131na g\u00f6re uyarlan\u0131r.<\/li><li><strong>Y\u00fckleme pimi<\/strong>: Poliasetal veya paslanmaz \u00e7elikten yap\u0131lm\u0131\u015f, kuvveti e\u015fit olarak uygulamak i\u00e7in tasarlanm\u0131\u015ft\u0131r.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a8c15d0 elementor-widget elementor-widget-image\" data-id=\"a8c15d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"202\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-1024x258.webp\" class=\"attachment-large size-large wp-image-163\" alt=\"\u015e\u0131r\u0131nga Parmak Flan\u015f\u0131 K\u0131r\u0131lma Kuvveti Testi - ISO 11040-4 Ek C1\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-1024x258.webp 1024w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-300x76.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-768x194.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1.webp 1190w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a78210 e-flex e-con-boxed e-con e-parent\" data-id=\"3a78210\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e89a55d elementor-widget elementor-widget-heading\" data-id=\"e89a55d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u015e\u0131r\u0131nga Testi Kurulumu ve Y\u00fcr\u00fct\u00fclmesi<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e8f3f2 elementor-widget elementor-widget-text-editor\" data-id=\"2e8f3f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Testin a\u015fa\u011f\u0131da belirtilen \u015fekilde ger\u00e7ekle\u015ftirilmesi i\u00e7in <strong>ISO 11040-4 testi<\/strong>a\u015fa\u011f\u0131daki ad\u0131mlar\u0131 izleyin:<\/p><h3>1. \u00d6rnek Haz\u0131rlama<\/h3><p>Testten \u00f6nce \u015f\u0131r\u0131nga kovanlar\u0131n\u0131 \u015foklamaktan veya yanl\u0131\u015f kullanmaktan ka\u00e7\u0131n\u0131n. Tutucuyu ve pimi a\u015f\u0131nma a\u00e7\u0131s\u0131ndan inceleyin.<\/p><h3>2. Ekipman Kurulumu<\/h3><ul><li>\u015e\u0131r\u0131ngay\u0131 flan\u015f\u0131n alt\u0131ndaki tutucuya yerle\u015ftirin.<\/li><li>Namlu flan\u015f\u0131n\u0131n derinli\u011fine kuvvet uygulamak i\u00e7in y\u00fckleme pimini hizalay\u0131n.<\/li><\/ul><h3>3. Test Y\u00fcr\u00fctme<\/h3><ul><li>Makineyi \u015fu h\u0131zda \u00e7al\u0131\u015ft\u0131r\u0131n <strong>100 mm\/dak<\/strong>.<\/li><li>Kuvvet-yer de\u011fi\u015ftirme grafi\u011fini kaydedin.<\/li><li>Kullan\u0131m <strong>en az 500 Hz \u00f6rnekleme h\u0131z\u0131<\/strong> tepe kuvveti tespiti i\u00e7in.<\/li><\/ul><h3>4. Sonu\u00e7 Analizi<\/h3><p>Flan\u015f ar\u0131zas\u0131ndan \u00f6nce g\u00f6zlemlenen en y\u00fcksek kuvvet <strong>parmak flan\u015f\u0131 k\u0131r\u0131lma kuvveti<\/strong>. ISO 11040-4 Ek C1, test h\u0131z\u0131 ve numune say\u0131s\u0131 ile birlikte bu de\u011ferin nihai dok\u00fcmantasyonda rapor edilmesi gerekti\u011fini belirtir.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2d148ee e-grid e-con-full e-con e-parent\" data-id=\"2d148ee\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef5e9b3 elementor-widget elementor-widget-image\" data-id=\"ef5e9b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f83c119 e-con-full e-flex e-con e-child\" data-id=\"f83c119\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-af86f15 elementor-widget elementor-widget-heading\" data-id=\"af86f15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Neden Se\u00e7melisiniz <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-321653d elementor-widget elementor-widget-text-editor\" data-id=\"321653d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Do\u011fru flan\u015f k\u0131r\u0131lma kuvveti testi, y\u00fcksek performansl\u0131 cihazlar gerektirir. At <strong>Syringetest.com<\/strong>i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015f geli\u015fmi\u015f \u00e7ekme ve s\u0131k\u0131\u015ft\u0131rma test cihazlar\u0131 sunuyoruz <strong>\u015f\u0131r\u0131nga testi<\/strong>ile tam uyumludur. <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><em>ISO 11040-4<\/em><\/a>. Sistemlerimiz hassas y\u00fck h\u00fccreleri, ayarlanabilir h\u0131zlar ve ger\u00e7ek zamanl\u0131 veri g\u00f6rselle\u015ftirme ve d\u0131\u015fa aktarma i\u00e7in sezgisel yaz\u0131l\u0131m ile donat\u0131lm\u0131\u015ft\u0131r.<\/p><p>Ayr\u0131ca \u015funlar\u0131 da sunuyoruz <strong>\u00f6zel \u015firinga tutucular ve otomasyon entegrasyonu<\/strong>y\u00fcksek verimli \u00fcretim ortamlar\u0131nda testleri kolayla\u015ft\u0131rmaya yard\u0131mc\u0131 olur.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-262c330 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"262c330\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/tr\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Bize Ula\u015f\u0131n<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Finger Flange Breakage Force Testing In the pharmaceutical and medical packaging industry, finger flange breakage force is a critical performance indicator for ensuring the structural reliability of syringe barrels. This parameter, defined and standardized in ISO 11040-4 Annex C1, helps manufacturers and quality assurance professionals assess whether the syringe flange can withstand mechanical stress during [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-154","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/pages\/154","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/comments?post=154"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/pages\/154\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/tr\/wp-json\/wp\/v2\/media?parent=154"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}