{"id":608,"date":"2025-07-02T05:36:28","date_gmt":"2025-07-02T05:36:28","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=608"},"modified":"2025-07-02T07:28:27","modified_gmt":"2025-07-02T07:28:27","slug":"iso-7886-1","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/sv\/standards\/iso-7886-1","title":{"rendered":"ISO 7886-1"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"608\" class=\"elementor elementor-608\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-292be0b e-flex e-con-boxed e-con e-parent\" data-id=\"292be0b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0f48abd elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"0f48abd\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 7886-1 Standard f\u00f6r funktionstest av sprutor<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6817f29 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"6817f29\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"389\" data-end=\"862\"><strong data-start=\"408\" data-end=\"422\">ISO 7886-1<\/strong> \u00e4r en internationellt erk\u00e4nd standard som definierar prestanda- och testkrav f\u00f6r <em data-start=\"524\" data-end=\"599\">sterila hypodermiska sprutor f\u00f6r eng\u00e5ngsbruk, avsedda f\u00f6r manuell anv\u00e4ndning<\/em>. Denna standard spelar en viktig roll i kvalitetskontrollen av sprutor och s\u00e4kerst\u00e4ller funktionss\u00e4kerhet och patientskydd. Kvalitetskontrollingenj\u00f6rer och regleringsspecialister f\u00f6rlitar sig p\u00e5 detta dokument f\u00f6r att v\u00e4gleda <em data-start=\"797\" data-end=\"828\">test av sprutans funktionalitet<\/em> och validera produktens prestanda. Fr\u00e5n <strong data-start=\"869\" data-end=\"908\">test av bryt- och glidkraft<\/strong> till <strong data-start=\"912\" data-end=\"936\">l\u00e4ckagetestning av sprutor<\/strong>ISO 7886-1 beskriver exakta testmetoder f\u00f6r att utv\u00e4rdera sprutans integritet.\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad68bc6 e-flex e-con-boxed e-con e-parent\" data-id=\"ad68bc6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ecf369e elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ecf369e\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Krav p\u00e5 nyckelprestanda enligt ISO 7886-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-343a570 e-n-tabs-mobile elementor-invisible elementor-widget elementor-widget-n-tabs\" data-id=\"343a570\" data-element_type=\"widget\" data-settings=\"{&quot;tabs_justify_horizontal&quot;:&quot;center&quot;,&quot;_animation&quot;:&quot;fadeInUp&quot;,&quot;horizontal_scroll&quot;:&quot;disable&quot;}\" data-widget_type=\"nested-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-tabs\" data-widget-number=\"54764912\" aria-label=\"Tab. Buka item dengan Enter atau Spasi, tutup dengan Escape dan navigasikan menggunakan tombol Panah.\" data-no-translation-aria-label=\"\">\n\t\t\t<div class=\"e-n-tabs-heading\" role=\"tablist\">\n\t\t\t\t\t<button id=\"e-n-tab-title-547649121\" class=\"e-n-tab-title\" aria-selected=\"true\" data-tab-index=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"e-n-tab-content-547649121\" style=\"--n-tabs-title-order: 1;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tDead Space\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-547649122\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-547649122\" style=\"--n-tabs-title-order: 2;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tLuft- och v\u00e4tskel\u00e4ckage\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-547649123\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-547649123\" style=\"--n-tabs-title-order: 3;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tKolvens man\u00f6vreringskraft\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-547649124\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-547649124\" style=\"--n-tabs-title-order: 4;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tKolvens passform och fasth\u00e5llning\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t\t<\/div>\n\t\t\t<div class=\"e-n-tabs-content\">\n\t\t\t\t<div id=\"e-n-tab-content-547649121\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-547649121\" data-tab-index=\"1\" style=\"--n-tabs-title-order: 1;\" class=\"e-active elementor-element elementor-element-9d08f18 e-flex e-con-boxed e-con e-child\" data-id=\"9d08f18\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a7b7101 elementor-widget elementor-widget-text-editor\" data-id=\"a7b7101\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"347\" data-end=\"741\">F\u00f6r att minska medicinavfallet och minimera risken f\u00f6r korskontaminering kr\u00e4ver ISO 7886-1 att sprutans d\u00f6dutrymme - den v\u00e4tskevolym som \u00e5terst\u00e5r efter att kolven f\u00f6rts in helt - m\u00e5ste h\u00e5llas p\u00e5 en minimal niv\u00e5.<\/p><p data-start=\"743\" data-end=\"1267\">\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-547649122\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-547649122\" data-tab-index=\"2\" style=\"--n-tabs-title-order: 2;\" class=\"elementor-element elementor-element-56c370d e-flex e-con-boxed e-con e-child\" data-id=\"56c370d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8f5102f elementor-widget elementor-widget-text-editor\" data-id=\"8f5102f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"743\" data-end=\"1267\">Sprutor m\u00e5ste uppvisa robust t\u00e4tningsprestanda. I enlighet med <em data-start=\"850\" data-end=\"859\">Bilaga D<\/em>b\u00f6r det finnas <strong data-start=\"877\" data-end=\"908\">inget synligt l\u00e4ckage av vatten<\/strong> f\u00f6rbi kolvproppen eller t\u00e4tningen under kompression. Medan sm\u00e5 droppar mellan interna t\u00e4tningar \u00e4r till\u00e5tna, utg\u00f6r externt l\u00e4ckage ett fel. Dessutom g\u00e4ller f\u00f6ljande, <em data-start=\"1076\" data-end=\"1085\">Bilaga B<\/em> f\u00f6reskriver att <strong data-start=\"1100\" data-end=\"1118\">inget luftl\u00e4ckage<\/strong> eller fall i vakuumtrycket kan uppst\u00e5 under aspirationstestet. Dessa kriterier s\u00e4kerst\u00e4ller sprutans barri\u00e4rintegritet och en s\u00e4ker klinisk anv\u00e4ndning.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-547649123\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-547649123\" data-tab-index=\"3\" style=\"--n-tabs-title-order: 3;\" class=\"elementor-element elementor-element-0debdba e-flex e-con-boxed e-con e-child\" data-id=\"0debdba\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-94d47e2 elementor-widget elementor-widget-text-editor\" data-id=\"94d47e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1269\" data-end=\"1702\">ISO 7886-1 rekommenderar att man verifierar de krafter som kr\u00e4vs f\u00f6r att initiera och uppr\u00e4tth\u00e5lla kolvr\u00f6relsen, eftersom sprutans anv\u00e4ndbarhet och dosreglering \u00e4r beroende av detta. <em data-start=\"1457\" data-end=\"1466\">Bilaga E<\/em> presenterar en metod f\u00f6r att m\u00e4ta <strong data-start=\"1500\" data-end=\"1532\">bryta loss och glida krafter<\/strong> med hj\u00e4lp av ett mekaniskt testsystem. \u00c4ven om detta test \u00e4r informativt snarare \u00e4n obligatoriskt, spelar det en avg\u00f6rande roll f\u00f6r att s\u00e4kerst\u00e4lla konsekvent och anv\u00e4ndarv\u00e4nlig prestanda.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-547649124\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-547649124\" data-tab-index=\"4\" style=\"--n-tabs-title-order: 4;\" class=\"elementor-element elementor-element-99198a0 e-flex e-con-boxed e-con e-child\" data-id=\"99198a0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d2653db elementor-widget elementor-widget-text-editor\" data-id=\"d2653db\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Kolvproppen m\u00e5ste sitta ordentligt fast i cylindern. F\u00f6r att bekr\u00e4fta detta fylls sprutan till sin nominella kapacitet och h\u00e5lls vertikalt - b\u00e5de uppr\u00e4tt och inverterad. I b\u00e5da l\u00e4gena ska kolven <strong data-start=\"1945\" data-end=\"1979\">inte r\u00f6r sig p\u00e5 grund av sin egen vikt<\/strong> eller enbart vattnets vikt. Detta krav skyddar mot oavsiktliga r\u00f6relser som kan leda till feldosering eller l\u00e4ckage.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4835ce e-flex e-con-boxed e-con e-parent\" data-id=\"d4835ce\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea29382 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ea29382\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test av sprutans funktionalitet: Viktiga parametrar och testmetoder<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-55047da e-con-full e-flex e-con e-child\" data-id=\"55047da\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-ae8face e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"ae8face\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7c7cd83 elementor-widget elementor-widget-heading\" data-id=\"7c7cd83\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.syringetest.com\/sv\/break-loose-and-glide-force-testing\/\">Test av bryt- och glidkraft<\/a><\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-42248e5 elementor-widget elementor-widget-text-editor\" data-id=\"42248e5\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1844\" data-end=\"2038\"><strong data-start=\"1844\" data-end=\"1855\">Bilaga E<\/strong> av ISO 7886-1 specificerar metoden f\u00f6r att best\u00e4mma <em data-start=\"1911\" data-end=\"1924\">bryta sig loss<\/em> och <em data-start=\"1929\" data-end=\"1942\">glidflygkraft<\/em> kr\u00e4vs f\u00f6r att man\u00f6vrera kolven. Dessa krafter p\u00e5verkar anv\u00e4ndarupplevelsen och kontrollen av doseringen.<\/p><ul><li data-start=\"2042\" data-end=\"2112\"><a href=\"https:\/\/www.syringetest.com\/sv\/break-loose-and-glide-force-testing\/\"><strong data-start=\"2042\" data-end=\"2063\">Bryt loss kraft<\/strong><\/a> \u00e4r den initiala kraft som kr\u00e4vs f\u00f6r att flytta kolven.<\/li><li data-start=\"2115\" data-end=\"2188\"><a href=\"https:\/\/www.syringetest.com\/sv\/break-loose-and-glide-force-testing\/\"><strong data-start=\"2115\" data-end=\"2130\">Glidande kraft<\/strong><\/a> \u00e4r den genomsnittliga kraft som kr\u00e4vs f\u00f6r att forts\u00e4tta kolvens r\u00f6relse.<\/li><\/ul><p data-start=\"2190\" data-end=\"2217\"><strong data-start=\"2190\" data-end=\"2217\">Testmetod H\u00f6jdpunkter:<\/strong><\/p><ul><li data-start=\"2220\" data-end=\"2329\">Anv\u00e4nd ett mekaniskt testsystem (t.ex. Cell Instruments' <strong data-start=\"2277\" data-end=\"2309\">MST-01 Tester f\u00f6r medicinska sprutor<\/strong>) vid 100 \u00b1 5 mm\/min.<\/li><li data-start=\"2332\" data-end=\"2369\">Fyll sprutan med vatten vid 23 \u00b1 5 \u00b0C.<\/li><li data-start=\"2372\" data-end=\"2457\">Anslut sprutan till slangen och tryck ut vatten tills kolven n\u00e5r den nominella markeringen.<\/li><li data-start=\"2460\" data-end=\"2467\">Rekord:<ul><li data-start=\"2472\" data-end=\"2499\">Initial r\u00f6relsekraft (f\u209b)<\/li><li data-start=\"2504\" data-end=\"2525\">Genomsnittlig r\u00f6relsekraft (F)<\/li><li data-start=\"2530\" data-end=\"2558\">Maximal motst\u00e5ndskraft (Fmax)<\/li><\/ul><\/li><\/ul><p data-start=\"2560\" data-end=\"2677\"><em data-start=\"2560\" data-end=\"2677\">Konsekventa glidprestanda s\u00e4kerst\u00e4ller j\u00e4mn injektion och anv\u00e4ndarkomfort, vilket g\u00f6r det till ett viktigt kvalitetsm\u00e5tt.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fda7334 e-con-full e-flex e-con e-child\" data-id=\"fda7334\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a601c24 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-image\" data-id=\"a601c24\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInRight&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"546\" height=\"719\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\" class=\"attachment-large size-large wp-image-613\" alt=\"ISO 7886-1 Bilaga E\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp 546w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E-228x300.webp 228w\" sizes=\"(max-width: 546px) 100vw, 546px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7ada073 e-con-full e-flex e-con e-child\" data-id=\"7ada073\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-61bbbd2 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"61bbbd2\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.syringetest.com\/sv\/syringe-liquid-leakage-test-for-closure-system\/\">Detektering av v\u00e4tskel\u00e4ckage i spruta (under kompression)<\/a><\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e3eedc elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"0e3eedc\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2741\" data-end=\"2896\"><strong data-start=\"2741\" data-end=\"2752\">Bilaga D<\/strong> beskriver en metod f\u00f6r att detektera <a href=\"https:\/\/www.syringetest.com\/sv\/syringe-liquid-leakage-test-for-closure-system\/\"><strong data-start=\"2781\" data-end=\"2799\">v\u00e4tskel\u00e4ckage<\/strong><\/a> f\u00f6rbi <strong data-start=\"2809\" data-end=\"2833\">kolv propp t\u00e4tning<\/strong> under komprimering - en viktig indikator p\u00e5 sprutans tillf\u00f6rlitlighet.<\/p><p data-start=\"2898\" data-end=\"2915\"><strong data-start=\"2898\" data-end=\"2915\">Testprocess:<\/strong><\/p><ul><li data-start=\"2918\" data-end=\"2985\">Fyll sprutan till nominell volym med destillerat vatten (18-28 \u00b0C).<\/li><li data-start=\"2988\" data-end=\"3049\">F\u00f6rslut sprutans munstycke med kopplingar som uppfyller ISO 80369-7.<\/li><li data-start=\"3052\" data-end=\"3098\">Applicera en kraft i sidled (0,25-3 N) p\u00e5 kolven.<\/li><li data-start=\"3101\" data-end=\"3163\">Applicera axiell kraft f\u00f6r att generera inre tryck (200-300 kPa).<\/li><li data-start=\"3166\" data-end=\"3193\">H\u00e5ll kvar i 30-35 sekunder.<\/li><li data-start=\"3196\" data-end=\"3238\">Kontrollera att ingen v\u00e4tska l\u00e4cker ut ur pipan.<\/li><\/ul><p data-start=\"3240\" data-end=\"3361\">Cell Instruments erbjuder <strong data-start=\"3268\" data-end=\"3298\">SLT-02 L\u00e4ckagetestare f\u00f6r sprutor<\/strong>perfekt f\u00f6r exakt tryckkontroll och observation i realtid.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb1aef4 e-con-full e-flex e-con e-child\" data-id=\"cb1aef4\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-64a5239 e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"64a5239\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c50402d elementor-widget elementor-widget-heading\" data-id=\"c50402d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Detektering av luftl\u00e4ckage i sprutan (under aspiration)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b9b9803 elementor-widget elementor-widget-text-editor\" data-id=\"b9b9803\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3422\" data-end=\"3549\"><strong data-start=\"3422\" data-end=\"3433\">Bilaga B<\/strong> definierar f\u00f6rfaranden f\u00f6r <strong data-start=\"3457\" data-end=\"3490\">Luftl\u00e4cks\u00f6kning av spruta<\/strong> och verifiering av att kolvstoppet h\u00e5lls kvar under aspirationen.<\/p><p data-start=\"3551\" data-end=\"3565\"><strong data-start=\"3551\" data-end=\"3565\">F\u00f6rfarande:<\/strong><\/p><ul><li data-start=\"3568\" data-end=\"3635\">Fyll sprutan delvis med vatten och dra kolven till nominell markering.<\/li><li data-start=\"3638\" data-end=\"3690\">S\u00e4kra kolven och anslut sprutan till vakuumsystemet.<\/li><li data-start=\"3693\" data-end=\"3736\">Generera 88 kPa under atmosf\u00e4rstryck.<\/li><li data-start=\"3739\" data-end=\"3762\">Observera i 60 sekunder:<ul><li data-start=\"3767\" data-end=\"3810\">Manometertryckfall (indikerar l\u00e4ckage)<\/li><li data-start=\"3815\" data-end=\"3848\">Kolven lossnar eller \u00e4r instabil<\/li><\/ul><\/li><\/ul><p data-start=\"3850\" data-end=\"3955\">Luftt\u00e4thet s\u00e4kerst\u00e4ller doseringsnoggrannhet och f\u00f6rhindrar kontaminering, vilket g\u00f6r detta test avg\u00f6rande f\u00f6r s\u00e4ker anv\u00e4ndning.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a4bf01b e-con-full e-flex e-con e-child\" data-id=\"a4bf01b\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-812ae93 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-image\" data-id=\"812ae93\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInRight&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"694\" height=\"570\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B.webp\" class=\"attachment-large size-large wp-image-614\" alt=\"ISO 7886-1 Bilaga B\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B.webp 694w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B-300x246.webp 300w\" sizes=\"(max-width: 694px) 100vw, 694px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-41ab1d6 e-con-full e-flex e-con e-parent\" data-id=\"41ab1d6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-48c60fb elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"48c60fb\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e4lja r\u00e4tt utrustning f\u00f6r sprutprovning<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-57384eb e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"57384eb\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInUp&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ffb5df1 eael-infobox-content-align--center eael-infobox-shape-square eael-infobox-hover-img-shape-square elementor-widget elementor-widget-eael-info-box\" data-id=\"ffb5df1\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"eael-info-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-infobox icon-on-top\">\n\t            <div class=\"infobox-icon\">\n\n                            <img decoding=\"async\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B-air-leakage-test-for-syringe.webp\" alt=\"ISO 7886-1 Bilaga B luftl\u00e4ckagetest f\u00f6r spruta\">\n            \n            \n            \n        <\/div>\n            <div class=\"infobox-content\">\n                    <div class=\"infobox-title-section\">\n                <h3 class=\"title\">SLT-02 L\u00e4ckagetestare f\u00f6r sprutor<\/h3>            <\/div>\n            <div><p data-start=\"0\" data-end=\"483\">Detta instrument applicerar exakt ett kontrollerat vakuum p\u00e5 sprutan, vilket m\u00f6jligg\u00f6r noggrann \u00f6vervakning av tryckf\u00f6r\u00e4ndringar och kolvens integritet. SLT-01 \u00e4r utformad med ISO 80369-7-kompatibla anslutningar och s\u00e4kra kl\u00e4mmekanismer, vilket s\u00e4kerst\u00e4ller noggrann utv\u00e4rdering av b\u00e5de luftt\u00e4thet och kolvstoppets retention.<\/p><p data-start=\"485\" data-end=\"945\">\u00a0<\/p><\/div>        <\/div>\n            <\/div>\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c042898 eael-infobox-content-align--center eael-infobox-shape-square eael-infobox-hover-img-shape-square elementor-widget elementor-widget-eael-info-box\" data-id=\"c042898\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"eael-info-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-infobox icon-on-top\">\n\t            <div class=\"infobox-icon\">\n\n                            <img decoding=\"async\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E-syringe-glide-force-tester.webp\" alt=\"ISO 7886-1 Bilaga E sprutans glidkraftsprovare\">\n            \n            \n            \n        <\/div>\n            <div class=\"infobox-content\">\n                    <div class=\"infobox-title-section\">\n                <h2 class=\"title\">MST-01 Tester f\u00f6r medicinska sprutor<\/h2>            <\/div>\n            <div><p data-start=\"485\" data-end=\"945\">Den anv\u00e4nder ett mekaniskt system med h\u00f6g precision f\u00f6r att m\u00e4ta l\u00f6sg\u00f6rings- och glidkrafter under v\u00e4tskeutdrivning. MST-01 g\u00f6r det m\u00f6jligt f\u00f6r tillverkare att kvantifiera initierings- och r\u00f6relsemotst\u00e5ndet, vilket ger viktiga data f\u00f6r att s\u00e4kerst\u00e4lla en j\u00e4mn och konsekvent kolvr\u00f6relse - avg\u00f6rande f\u00f6r s\u00e4kerhet och komfort.<\/p><p data-start=\"947\" data-end=\"1407\" data-is-last-node=\"\" data-is-only-node=\"\">\u00a0<\/p><\/div>        <\/div>\n            <\/div>\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a5ad445 eael-infobox-content-align--center eael-infobox-shape-square eael-infobox-hover-img-shape-square elementor-widget elementor-widget-eael-info-box\" data-id=\"a5ad445\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"eael-info-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-infobox icon-on-top\">\n\t            <div class=\"infobox-icon\">\n\n                            <img decoding=\"async\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-D-liquid-leakage-at-syringe-plunger-stopper-under-compression.webp\" alt=\"ISO 7886-1 Bilaga D v\u00e4tskel\u00e4ckage vid sprutans kolvpropp under kompression\">\n            \n            \n            \n        <\/div>\n            <div class=\"infobox-content\">\n                    <div class=\"infobox-title-section\">\n                <h2 class=\"title\">SPPT-01 Sprutans t\u00e4thetsprovare<\/h2>            <\/div>\n            <div><p>Denna enhet simulerar trycket inuti sprutans cylinder samtidigt som den applicerar laterala och axiella belastningar p\u00e5 kolven, vilket n\u00e4ra replikerar kliniska anv\u00e4ndningsf\u00f6rh\u00e5llanden. SSPT-01 \u00e4r konstruerad f\u00f6r att uppt\u00e4cka \u00e4ven subtila t\u00e4tningsfel, vilket hj\u00e4lper tillverkare att verifiera produkttillf\u00f6rlitlighet och efterlevnad av str\u00e4nga s\u00e4kerhetsstandarder.<\/p><\/div>        <\/div>\n            <\/div>\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad468be e-flex e-con-boxed e-con e-parent\" data-id=\"ad468be\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-edb7717 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"edb7717\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Varf\u00f6r efterlevnad av ISO 7886-1 \u00e4r viktigt<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5810d33 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"5810d33\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4571\" data-end=\"4657\">Genom att f\u00f6lja ISO 7886-1 s\u00e4kerst\u00e4lls att sprutorna:<\/p><ul><li data-start=\"4660\" data-end=\"4682\">Leverera exakta doser<\/li><li data-start=\"4685\" data-end=\"4713\">\u00c4r s\u00e4kra och enkla att anv\u00e4nda<\/li><li data-start=\"4716\" data-end=\"4740\">F\u00f6rblir f\u00f6rseglade under anv\u00e4ndning<\/li><li data-start=\"4743\" data-end=\"4789\">Uppfylla globala reglerings- och exportkrav<\/li><\/ul><p data-start=\"4791\" data-end=\"4910\">F\u00f6rsummelse av korrekt <strong data-start=\"4809\" data-end=\"4842\">test av sprutans funktionalitet<\/strong> kan leda till produkt\u00e5terkallelser, regulatoriska p\u00e5f\u00f6ljder eller patientskador.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b581cc e-con-full e-flex e-con e-parent\" data-id=\"1b581cc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-61afd37 e-grid e-con-full e-con e-child\" data-id=\"61afd37\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-f8ace73 e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"f8ace73\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94cc5ad e-flex e-con-boxed elementor-invisible e-con e-child\" data-id=\"94cc5ad\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInRight&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-907b713 elementor-widget elementor-widget-heading\" data-id=\"907b713\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Varf\u00f6r v\u00e4lja <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-718f32f elementor-widget elementor-widget-text-editor\" data-id=\"718f32f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4917\" data-end=\"5240\">F\u00f6rst\u00e5else och till\u00e4mpning <strong data-start=\"4961\" data-end=\"4975\">ISO 7886-1<\/strong> testmetoder \u00e4r avg\u00f6rande f\u00f6r alla f\u00f6retag som \u00e4r involverade i sprutproduktion eller kvalitetskontroll. Fr\u00e5n <strong data-start=\"5077\" data-end=\"5116\">test av bryt- och glidkraft<\/strong> till <strong data-start=\"5120\" data-end=\"5153\">Detektering av luft- och v\u00e4tskel\u00e4ckage<\/strong>Varje test har en specifik roll n\u00e4r det g\u00e4ller att garantera produktens tillf\u00f6rlitlighet och anv\u00e4ndarnas s\u00e4kerhet.<\/p><p data-start=\"5242\" data-end=\"5537\"><strong>Syringetest.com<\/strong> tillhandah\u00e5ller avancerad <strong data-start=\"5281\" data-end=\"5310\">Testutrustning f\u00f6r sprutor<\/strong> utformade f\u00f6r att st\u00f6dja fullst\u00e4ndig efterlevnad och str\u00f6mlinjeformade QC-arbetsfl\u00f6den. Om du vill uppgradera din sprutvalideringsprocess eller f\u00f6rb\u00e4ttra testnoggrannheten, kontakta oss f\u00f6r att f\u00e5 veta hur v\u00e5ra instrument kan hj\u00e4lpa dig att uppfylla dina standarder.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f735b94 elementor-widget elementor-widget-eael-creative-button\" data-id=\"f735b94\" data-element_type=\"widget\" data-widget_type=\"eael-creative-button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-creative-button-wrapper\">\n\n            <a class=\"eael-creative-button eael-creative-button--default\" href=\"#\" data-text=\"Contact Us\">\n\n\t    \n                <div class=\"creative-button-inner\">\n\n                    \n                    <span class=\"cretive-button-text\">Kontakta oss<\/span>\n\n                                    <\/div>\n\t                        <\/a>\n        <\/div>\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 7886-1 Syringe Functionality Testing Standard ISO 7886-1 is the internationally recognized standard that defines the performance and testing requirements for sterile hypodermic syringes for single use, intended for manual operation. This standard plays a vital role in syringe quality control, ensuring functional safety and patient protection. Quality control engineers and regulatory specialists rely on [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"parent":603,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-608","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 7886-1 Syringe Functionality Testing and Testing Equipment<\/title>\n<meta name=\"description\" content=\"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.syringetest.com\/sv\/standards\/iso-7886-1\/\" \/>\n<meta property=\"og:locale\" content=\"sv_SE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 7886-1 Syringe Functionality Testing and Testing Equipment\" \/>\n<meta property=\"og:description\" content=\"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.syringetest.com\/sv\/standards\/iso-7886-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Syringe and Needle Testing\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-02T07:28:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"546\" \/>\n\t<meta property=\"og:image:height\" content=\"719\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Ber\u00e4knad l\u00e4stid\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minuter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1\",\"url\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1\",\"name\":\"ISO 7886-1 Syringe Functionality Testing and Testing Equipment\",\"isPartOf\":{\"@id\":\"https:\/\/www.syringetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\",\"datePublished\":\"2025-07-02T05:36:28+00:00\",\"dateModified\":\"2025-07-02T07:28:27+00:00\",\"description\":\"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#breadcrumb\"},\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.syringetest.com\/standards\/iso-7886-1\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.syringetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Standards\",\"item\":\"https:\/\/www.syringetest.com\/standards\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ISO 7886-1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.syringetest.com\/#website\",\"url\":\"https:\/\/www.syringetest.com\/\",\"name\":\"Syringe and Needle Testing\",\"description\":\"Syringe and Needle Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.syringetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.syringetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sv-SE\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.syringetest.com\/#organization\",\"name\":\"Syringe and Needle Testing\",\"url\":\"https:\/\/www.syringetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"width\":512,\"height\":512,\"caption\":\"Syringe and Needle Testing\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 7886-1 Syringe Functionality Testing and Testing Equipment","description":"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.syringetest.com\/sv\/standards\/iso-7886-1\/","og_locale":"sv_SE","og_type":"article","og_title":"ISO 7886-1 Syringe Functionality Testing and Testing Equipment","og_description":"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.","og_url":"https:\/\/www.syringetest.com\/sv\/standards\/iso-7886-1\/","og_site_name":"Syringe and Needle Testing","article_modified_time":"2025-07-02T07:28:27+00:00","og_image":[{"width":546,"height":719,"url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Ber\u00e4knad l\u00e4stid":"6 minuter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1","url":"https:\/\/www.syringetest.com\/standards\/iso-7886-1","name":"ISO 7886-1 Syringe Functionality Testing and Testing Equipment","isPartOf":{"@id":"https:\/\/www.syringetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage"},"image":{"@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage"},"thumbnailUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp","datePublished":"2025-07-02T05:36:28+00:00","dateModified":"2025-07-02T07:28:27+00:00","description":"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.","breadcrumb":{"@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#breadcrumb"},"inLanguage":"sv-SE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.syringetest.com\/standards\/iso-7886-1"]}]},{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.syringetest.com\/"},{"@type":"ListItem","position":2,"name":"Standards","item":"https:\/\/www.syringetest.com\/standards"},{"@type":"ListItem","position":3,"name":"ISO 7886-1"}]},{"@type":"WebSite","@id":"https:\/\/www.syringetest.com\/#website","url":"https:\/\/www.syringetest.com\/","name":"Syringe and Needle Testing","description":"Syringe and Needle Test Solutions","publisher":{"@id":"https:\/\/www.syringetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.syringetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sv-SE"},{"@type":"Organization","@id":"https:\/\/www.syringetest.com\/#organization","name":"Syringe and Needle Testing","url":"https:\/\/www.syringetest.com\/","logo":{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","width":512,"height":512,"caption":"Syringe and Needle Testing"},"image":{"@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/pages\/608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/comments?post=608"}],"version-history":[{"count":5,"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/pages\/608\/revisions"}],"predecessor-version":[{"id":627,"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/pages\/608\/revisions\/627"}],"up":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/pages\/603"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/media?parent=608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}