{"id":154,"date":"2025-04-30T01:31:34","date_gmt":"2025-04-30T01:31:34","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=154"},"modified":"2026-05-09T06:36:31","modified_gmt":"2026-05-09T06:36:31","slug":"finger-flange-breakage-force-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/sv\/finger-flange-breakage-force-test","title":{"rendered":"Test av kraft vid brott p\u00e5 fingerfl\u00e4ns"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"154\" class=\"elementor elementor-154\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-247db7c e-flex e-con-boxed e-con e-parent\" data-id=\"247db7c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab06118 elementor-widget elementor-widget-heading\" data-id=\"ab06118\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Kraftprovning av fingerfl\u00e4nsens brott<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62cf733 elementor-widget elementor-widget-text-editor\" data-id=\"62cf733\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Inom l\u00e4kemedels- och medicinf\u00f6rpackningsindustrin, <strong>finger fl\u00e4ns brytkraft<\/strong> \u00e4r en kritisk prestandaindikator f\u00f6r att s\u00e4kerst\u00e4lla den strukturella tillf\u00f6rlitligheten hos spruthylsor. Denna parameter, som definieras och standardiseras i <strong><em><a href=\"https:\/\/www.syringetest.com\/sv\/standards\/iso-11040-4\/\">ISO 11040-4<\/a> Bilaga C1<\/em><\/strong>hj\u00e4lper tillverkare och kvalitetss\u00e4krare att bed\u00f6ma om sprutans fl\u00e4ns klarar mekaniska p\u00e5frestningar under hantering och injektion.<\/p><p>Att f\u00f6rst\u00e5 denna m\u00e4tning och dess standardtestmetod \u00e4r avg\u00f6rande f\u00f6r yrkesverksamma som \u00e4r involverade i <strong>spruttestning<\/strong>, s\u00e4rskilt f\u00f6r sterila, sammansatta sprutor avsedda f\u00f6r injicerbara l\u00f6sningar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f136d2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f136d2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b673494 elementor-widget elementor-widget-heading\" data-id=\"b673494\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Betydelsen av fingerfl\u00e4nsens brytkraft f\u00f6r sprutans integritet<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa819a0 elementor-widget elementor-widget-text-editor\" data-id=\"aa819a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Den <strong>finger fl\u00e4ns brytkraft<\/strong> avser den maximala mekaniska kraft som fl\u00e4nsen p\u00e5 en spruta kan motst\u00e5 innan den g\u00e5r s\u00f6nder. Detta v\u00e4rde indikerar sprutans robusthet, s\u00e4rskilt n\u00e4r anv\u00e4ndarna ut\u00f6var tryck under injektionen eller n\u00e4r automatiserade fyllningssystem greppar sprutan.<\/p><p>En otillr\u00e4cklig brytkraft kan leda till fl\u00e4nssprickor eller fullst\u00e4ndigt fel, vilket utg\u00f6r en s\u00e4kerhetsrisk. D\u00e4rf\u00f6r \u00e4r det inte f\u00f6rhandlingsbart att uppr\u00e4tth\u00e5lla en j\u00e4mn kvalitet mellan olika batcher vid tillverkning av medicintekniska produkter.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-37feff9 e-flex e-con-boxed e-con e-parent\" data-id=\"37feff9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3146496 elementor-widget elementor-widget-heading\" data-id=\"3146496\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kraftprov f\u00f6r brytning av fingerfl\u00e4ns - ISO 11040-4 Bilaga C1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08fc359 elementor-widget elementor-widget-text-editor\" data-id=\"08fc359\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Den <strong><a href=\"https:\/\/www.syringetest.com\/sv\/standards\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">ISO 11040-4<\/a> Bilaga C1<\/strong> beskriver testmetoden f\u00f6r utv\u00e4rdering av fl\u00e4nsens brottmotst\u00e5nd. Proceduren s\u00e4kerst\u00e4ller exakta och repeterbara resultat, vilket g\u00f6r den till guldstandarden f\u00f6r testning av sprutors prestanda.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd10895 e-grid e-con-full e-con e-child\" data-id=\"fd10895\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d98b842 elementor-widget elementor-widget-text-editor\" data-id=\"d98b842\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Testets m\u00e5l<\/h3><p>F\u00f6r att best\u00e4mma fl\u00e4nsens brottmotst\u00e5nd genom att applicera en ned\u00e5triktad kraft p\u00e5 sprutans pipa med hj\u00e4lp av specialutrustning. Detta test utv\u00e4rderar b\u00e5de <strong>h\u00e5llfasthet f\u00f6r glasfat<\/strong> och dess kompatibilitet med resten av sprutans design.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db58dbc elementor-widget elementor-widget-text-editor\" data-id=\"db58dbc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>N\u00f6dv\u00e4ndig utrustning<\/h3><ul><li><strong>Universell drag- och tryckprovningsmaskin<\/strong>: M\u00e5ste inkludera en l\u00e4mplig lastcell och en konfigurerbar testhastighet p\u00e5 <strong>100 mm\/min<\/strong>.<\/li><li><strong>Spruth\u00e5llare<\/strong>: Vanligtvis tillverkad av PEEK, anpassad till sprutans dimensioner.<\/li><li><strong>Lastpinne<\/strong>: Tillverkad av polyacetal eller rostfritt st\u00e5l, utformad f\u00f6r att applicera kraften j\u00e4mnt.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a8c15d0 elementor-widget elementor-widget-image\" data-id=\"a8c15d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"202\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-1024x258.webp\" class=\"attachment-large size-large wp-image-163\" alt=\"Test av sprutans fingerfl\u00e4ns f\u00f6r brottkraft - ISO 11040-4 Bilaga C1\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-1024x258.webp 1024w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-300x76.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-768x194.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1.webp 1190w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a78210 e-flex e-con-boxed e-con e-parent\" data-id=\"3a78210\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e89a55d elementor-widget elementor-widget-heading\" data-id=\"e89a55d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Uppl\u00e4gg och utf\u00f6rande av sprutprov<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e8f3f2 elementor-widget elementor-widget-text-editor\" data-id=\"2e8f3f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00f6r att utf\u00f6ra testet enligt specifikationerna i <strong>ISO 11040-4-testning<\/strong>F\u00f6lj dessa steg:<\/p><h3>1. Beredning av prov<\/h3><p>Undvik st\u00f6tar eller felaktig hantering av spruthylsorna f\u00f6re testning. Inspektera h\u00e5llare och stift f\u00f6r slitage.<\/p><h3>2. Upps\u00e4ttning av utrustning<\/h3><ul><li>Placera sprutan i h\u00e5llaren under fl\u00e4nsen.<\/li><li>Rikta in laddningsstiftet s\u00e5 att kraften appliceras p\u00e5 pipfl\u00e4nsens djup.<\/li><\/ul><h3>3. Utf\u00f6rande av test<\/h3><ul><li>K\u00f6r maskinen p\u00e5 <strong>100 mm\/min<\/strong>.<\/li><li>Registrera kraft-f\u00f6rskjutningsdiagrammet.<\/li><li>Anv\u00e4nd en <strong>samplingsfrekvens p\u00e5 minst 500 Hz<\/strong> f\u00f6r detektering av toppkraft.<\/li><\/ul><h3>4. Analys av resultat<\/h3><p>Den maximala kraft som observeras innan fl\u00e4nsen g\u00e5r s\u00f6nder registreras som <strong>finger fl\u00e4ns brytkraft<\/strong>. ISO 11040-4 Annex C1 specificerar att detta v\u00e4rde, tillsammans med testhastighet och provantal, ska rapporteras i den slutliga dokumentationen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2d148ee e-grid e-con-full e-con e-parent\" data-id=\"2d148ee\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef5e9b3 elementor-widget elementor-widget-image\" data-id=\"ef5e9b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f83c119 e-con-full e-flex e-con e-child\" data-id=\"f83c119\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-af86f15 elementor-widget elementor-widget-heading\" data-id=\"af86f15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Varf\u00f6r v\u00e4lja <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-321653d elementor-widget elementor-widget-text-editor\" data-id=\"321653d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Noggrann provning av fl\u00e4nsbrottskraft kr\u00e4ver h\u00f6gpresterande instrument. Vid <strong>Syringetest.com<\/strong>erbjuder vi avancerade drag- och kompressionsprovare som \u00e4r skr\u00e4ddarsydda f\u00f6r <strong>spruttestning<\/strong>, helt i \u00f6verensst\u00e4mmelse med <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><em>ISO 11040-4<\/em><\/a>. V\u00e5ra system \u00e4r utrustade med precisionslastceller, justerbara hastigheter och intuitiv programvara f\u00f6r visualisering och export av data i realtid.<\/p><p>Vi erbjuder ocks\u00e5 <strong>anpassade spruth\u00e5llare och integration av automation<\/strong>vilket bidrar till att effektivisera testning i produktionsmilj\u00f6er med h\u00f6g genomstr\u00f6mning.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-262c330 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"262c330\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/sv\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakta oss<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Finger Flange Breakage Force Testing In the pharmaceutical and medical packaging industry, finger flange breakage force is a critical performance indicator for ensuring the structural reliability of syringe barrels. This parameter, defined and standardized in ISO 11040-4 Annex C1, helps manufacturers and quality assurance professionals assess whether the syringe flange can withstand mechanical stress during [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-154","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/pages\/154","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/comments?post=154"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/pages\/154\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/sv\/wp-json\/wp\/v2\/media?parent=154"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}