{"id":492,"date":"2025-06-04T05:44:42","date_gmt":"2025-06-04T05:44:42","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=492"},"modified":"2026-05-19T08:11:59","modified_gmt":"2026-05-19T08:11:59","slug":"syringe-liquid-leakage-test-for-closure-system","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/sk\/syringe-liquid-leakage-test-for-closure-system","title":{"rendered":"Test \u00faniku kvapaliny z injek\u010dnej strieka\u010dky pre syst\u00e9m uzatv\u00e1rania"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"492\" class=\"elementor elementor-492\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-14a7ec1 e-flex e-con-boxed e-con e-parent\" data-id=\"14a7ec1\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8ba13c0 elementor-widget elementor-widget-heading\" data-id=\"8ba13c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Test \u00faniku kvapaliny zo syst\u00e9mu uzatv\u00e1rania injek\u010dn\u00fdch strieka\u010diek<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bbb28e6 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"bbb28e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"401\" data-end=\"1099\">Vo farmaceutickom priemysle a priemysle zdravotn\u00edckych pom\u00f4cok je zabezpe\u010denie integrity injek\u010dn\u00fdch strieka\u010diek k\u013e\u00fa\u010dov\u00e9 pre bezpe\u010dnos\u0165 v\u00fdrobkov a zdravie pacientov. Jedn\u00fdm z najd\u00f4le\u017eitej\u0161\u00edch postupov je <strong data-start=\"602\" data-end=\"633\">sk\u00fa\u0161ka \u00faniku kvapaliny z injek\u010dnej strieka\u010dky<\/strong>, v ktorom sa hodnot\u00ed schopnos\u0165 piestu injek\u010dnej strieka\u010dky a syst\u00e9mu uz\u00e1veru zabr\u00e1ni\u0165 \u00faniku kvapaliny pod tlakom. Tento \u010dl\u00e1nok poskytne komplexn\u00fd n\u00e1vod, ako vykona\u0165 sk\u00fa\u0161ku tesnosti injek\u010dnej strieka\u010dky v s\u00falade s <strong data-start=\"862\" data-end=\"884\"><a href=\"https:\/\/www.syringetest.com\/sk\/standards\/iso-7886-1\/\">ISO 7886-1<\/a> Pr\u00edloha D<\/strong> a <strong data-start=\"889\" data-end=\"913\"><a href=\"https:\/\/www.syringetest.com\/sk\/standards\/iso-11040-4\/\">ISO 11040-4<\/a> Pr\u00edloha G2<\/strong> normy. Ako popredn\u00fd v\u00fdrobca presn\u00fdch testovac\u00edch pr\u00edstrojov, <strong data-start=\"985\" data-end=\"1005\">Mobiln\u00e9 n\u00e1stroje<\/strong> pon\u00faka spo\u013eahliv\u00e9 rie\u0161enia pre profesion\u00e1lov a pracovn\u00edkov kontroly kvality pri testovan\u00ed injek\u010dn\u00fdch strieka\u010diek.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb57b12 e-flex e-con-boxed e-con e-parent\" data-id=\"cb57b12\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c5f7942 elementor-widget elementor-widget-heading\" data-id=\"c5f7942\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pochopenie testu \u00faniku kvapaliny z injek\u010dnej strieka\u010dky<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24b1f4a elementor-widget elementor-widget-text-editor\" data-id=\"24b1f4a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1106\" data-end=\"1433\">Str\u00e1nka <strong data-start=\"1162\" data-end=\"1193\">sk\u00fa\u0161ka \u00faniku kvapaliny z injek\u010dnej strieka\u010dky<\/strong> zaru\u010duje, \u017ee injek\u010dn\u00e9 strieka\u010dky zostan\u00fa tesn\u00e9 aj pri vystaven\u00ed tlaku. Posudzuje tesnos\u0165 piestovej z\u00e1tky aj uzatv\u00e1racieho syst\u00e9mu (krytov hrotov alebo \u0161t\u00edtov ihiel), \u010d\u00edm chr\u00e1ni pred kontamin\u00e1ciou a nepresnos\u0165ou d\u00e1vkovania.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0f9719a e-flex e-con-boxed e-con e-parent\" data-id=\"0f9719a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9a70f61 elementor-widget elementor-widget-heading\" data-id=\"9a70f61\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Sk\u00fa\u0161ka \u00faniku kvapaliny z injek\u010dnej strieka\u010dky pod\u013ea normy ISO 7886-1, pr\u00edloha D<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6461ae4 elementor-widget elementor-widget-text-editor\" data-id=\"6461ae4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1440\" data-end=\"1622\"><strong data-start=\"1506\" data-end=\"1528\">ISO 7886-1 Pr\u00edloha D<\/strong> na\u010drt\u00e1va presn\u00fa met\u00f3du hodnotenia tesniaceho v\u00fdkonu piestovej z\u00e1tky injek\u010dnej strieka\u010dky.<\/p><h3 data-start=\"1440\" data-end=\"1622\">Princ\u00edp testu<\/h3><p data-start=\"1624\" data-end=\"1847\">Injek\u010dn\u00e1 strieka\u010dka sa napln\u00ed destilovanou vodou, utesn\u00ed sa na d\u00fdze a p\u00f4sob\u00ed na \u0148u axi\u00e1lna aj radi\u00e1lna sila. Cie\u013eom je simulova\u0165 nap\u00e4tia, ktor\u00e9 by mohli sp\u00f4sobi\u0165 \u00fanik kvapaliny za z\u00e1tku piestu.<\/p><h3 data-start=\"1624\" data-end=\"1847\">Pr\u00edstroje a \u010dinidl\u00e1<\/h3><ul><li><strong data-start=\"1880\" data-end=\"1898\">Tesniace zariadenie<\/strong>: \u00dapln\u00e9 utesnenie alebo uzatvorenie trysky strieka\u010dky.<\/li><li><strong data-start=\"1949\" data-end=\"1977\">Zariadenie na aplik\u00e1ciu sily<\/strong>: Na piest p\u00f4sobi\u0165 bo\u010dnou silou 0,25 N a\u017e 3 N.<\/li><li><strong data-start=\"2042\" data-end=\"2061\">Tlakov\u00e9 zariadenie<\/strong>: Schopnos\u0165 generova\u0165 tlak <strong data-start=\"2098\" data-end=\"2109\">200 kPa<\/strong> a <strong data-start=\"2114\" data-end=\"2125\">300 kPa<\/strong>.<\/li><li><strong data-start=\"2131\" data-end=\"2150\">Destilovan\u00e1 voda<\/strong>: Udr\u017eiavan\u00e9 medzi <strong data-start=\"2171\" data-end=\"2189\">18 \u00b0C a\u017e 28 \u00b0C<\/strong>.<\/li><\/ul><h3 data-start=\"1624\" data-end=\"1847\">Postup testovania<\/h3><ol><li data-start=\"2216\" data-end=\"2283\">Napl\u0148te injek\u010dn\u00fa strieka\u010dku destilovanou vodou nad jej menovit\u00fd objem.<\/li><li data-start=\"2287\" data-end=\"2343\">Vypustite vzduch a upravte objem vody na menovit\u00fd objem.<\/li><li data-start=\"2347\" data-end=\"2373\">Utesnite trysku strieka\u010dky.<\/li><li data-start=\"2377\" data-end=\"2454\">Na piest p\u00f4sobte bo\u010dnou silou, aby ste dosiahli maxim\u00e1lnu radi\u00e1lnu v\u00fdchylku.<\/li><li data-start=\"2458\" data-end=\"2522\">Vytvorte po\u017eadovan\u00fd tlak a udr\u017eujte ho 30-35 sek\u00fand.<\/li><li data-start=\"2526\" data-end=\"2596\">Skontrolujte, \u010di injek\u010dn\u00e1 strieka\u010dka nevyte\u010die za z\u00e1tku piestu.<\/li><\/ol><h3 data-start=\"1624\" data-end=\"1847\">V\u00fdznam<\/h3><p data-start=\"2598\" data-end=\"2733\">Tento test simuluje manipula\u010dn\u00e9 za\u0165a\u017eenie, aby sa overilo, \u010di <strong data-start=\"2674\" data-end=\"2693\">piest strieka\u010dky<\/strong> udr\u017euje bezpe\u010dn\u00e9 utesnenie pod tlakom.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0e39f22 e-flex e-con-boxed e-con e-parent\" data-id=\"0e39f22\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9e4bce6 elementor-widget elementor-widget-heading\" data-id=\"9e4bce6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Sk\u00fa\u0161ka tesnosti uz\u00e1veru injek\u010dnej strieka\u010dky: ISO 11040-4 pr\u00edloha G2<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f35e53 elementor-widget elementor-widget-text-editor\" data-id=\"2f35e53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2740\" data-end=\"2956\">Str\u00e1nka <strong data-start=\"2798\" data-end=\"2848\">ISO 11040-4 Pr\u00edloha G2 Sk\u00fa\u0161ka tesnosti uz\u00e1veru injek\u010dnej strieka\u010dky<\/strong> sa zameriava na hodnotenie v\u00fdkonnosti <strong data-start=\"2889\" data-end=\"2916\">syst\u00e9my uzatv\u00e1rania injek\u010dn\u00fdch strieka\u010diek<\/strong>vr\u00e1tane krytov hrotov a \u0161t\u00edtov ihiel.<\/p><h3 data-start=\"2740\" data-end=\"2956\">Princ\u00edp testu<\/h3><p data-start=\"2958\" data-end=\"3123\">Cie\u013eom je overi\u0165, \u010di syst\u00e9m uz\u00e1veru injek\u010dnej strieka\u010dky odol\u00e1 pr\u00edpadn\u00e9mu pretlaku po\u010das plnenia alebo prepravy a zabr\u00e1ni \u00faniku.<\/p><h3 data-start=\"2740\" data-end=\"2956\">Postup testovania<\/h3><ol><li data-start=\"3149\" data-end=\"3208\">Napl\u0148te injek\u010dn\u00fa strieka\u010dku po <strong data-start=\"3169\" data-end=\"3183\">1\/3 a\u017e 2\/3<\/strong> menovit\u00e9ho objemu.<\/li><li data-start=\"3212\" data-end=\"3268\">Vlo\u017ete injek\u010dn\u00fa strieka\u010dku do dr\u017eiaka na testy a zaistite ju.<\/li><li data-start=\"3272\" data-end=\"3322\">Aplikova\u0165 <strong data-start=\"3278\" data-end=\"3289\">110 kPa<\/strong> tlaku na <strong data-start=\"3306\" data-end=\"3319\">5 sek\u00fand<\/strong>.<\/li><li data-start=\"3326\" data-end=\"3398\">Po\u010das testu a po \u0148om sledujte, \u010di injek\u010dn\u00e1 strieka\u010dka vidite\u013ene nevytek\u00e1.<\/li><li data-start=\"3402\" data-end=\"3544\">Uvo\u013enite tlak a vyhodno\u0165te syst\u00e9m: test prebehol \u00faspe\u0161ne, ak uz\u00e1very hrotov alebo \u0161t\u00edty ihiel zostali na mieste a zvonku sa netvoria \u017eiadne kvapky.<\/li><\/ol><h3 data-start=\"2740\" data-end=\"2956\">V\u00fdpo\u010det sily<\/h3><p data-start=\"3546\" data-end=\"3669\">Sila vn\u00fatorn\u00e9ho tlaku (<strong data-start=\"3602\" data-end=\"3607\">F<\/strong>) mo\u017eno vypo\u010d\u00edta\u0165 pomocou:<br data-start=\"3632\" data-end=\"3635\" \/>F = p \u00d7 \u03c0\/4 \u00d7 d\u00b2 \u00d7 10-\u00b3<br data-start=\"3658\" data-end=\"3661\" \/>kde:<\/p><ul><li data-start=\"3672\" data-end=\"3685\">p = 110 kPa<\/li><li data-start=\"3688\" data-end=\"3743\">d = menovit\u00fd vn\u00fatorn\u00fd priemer valca injek\u010dnej strieka\u010dky (mm)<\/li><\/ul><p data-start=\"3745\" data-end=\"3840\">T\u00fdm sa zabezpe\u010d\u00ed presn\u00e9 a konzistentn\u00e9 vyv\u00edjanie tlaku na injek\u010dn\u00fa strieka\u010dku po\u010das testu.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f6abf6 e-flex e-con-boxed e-con e-parent\" data-id=\"9f6abf6\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cabb0a8 elementor-widget elementor-widget-heading\" data-id=\"cabb0a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00fdhody pou\u017e\u00edvania testovac\u00edch rie\u0161en\u00ed Cell Instruments<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e08dd76 elementor-widget elementor-widget-text-editor\" data-id=\"e08dd76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3847\" data-end=\"4059\"><strong data-start=\"3907\" data-end=\"3927\">Mobiln\u00e9 n\u00e1stroje<\/strong> pon\u00faka pokro\u010dil\u00e9 a prisp\u00f4sobite\u013en\u00e9 <strong data-start=\"3961\" data-end=\"3992\">sk\u00fa\u0161ka \u00faniku kvapaliny z injek\u010dnej strieka\u010dky<\/strong> zariadenia prisp\u00f4soben\u00e9 norm\u00e1m ISO. Na\u0161e testovacie rie\u0161enia:<\/p><ul><li data-start=\"4062\" data-end=\"4106\">Poskytova\u0165 presn\u00e9 a reprodukovate\u013en\u00e9 v\u00fdsledky.<\/li><li data-start=\"4109\" data-end=\"4155\">Vhodn\u00fd pre r\u00f4zne ve\u013ekosti a typy injek\u010dn\u00fdch strieka\u010diek.<\/li><li data-start=\"4158\" data-end=\"4221\">Bezprobl\u00e9mov\u00e1 integr\u00e1cia s existuj\u00facimi pracovn\u00fdmi postupmi kontroly kvality.<\/li><\/ul><p data-start=\"4223\" data-end=\"4349\"><strong data-start=\"4223\" data-end=\"4251\">Z\u00e1kazn\u00edcke testovacie rie\u0161enia<\/strong> a <strong data-start=\"4256\" data-end=\"4294\">automatiza\u010dn\u00e9 transforma\u010dn\u00e9 slu\u017eby<\/strong> zabezpe\u010di\u0165 prisp\u00f4sobite\u013enos\u0165 \u0161pecifick\u00fdm po\u017eiadavk\u00e1m na testovanie.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-95bd826 e-flex e-con-boxed e-con e-parent\" data-id=\"95bd826\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-dd9a294 e-con-full e-flex e-con e-child\" data-id=\"dd9a294\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-350f1cc elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"350f1cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"465\" height=\"1024\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-465x1024.webp\" class=\"attachment-large size-large wp-image-494\" alt=\"Test \u00faniku kvapaliny z injek\u010dnej strieka\u010dky pre syst\u00e9m uzatv\u00e1rania\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-465x1024.webp 465w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-136x300.webp 136w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-768x1690.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-698x1536.webp 698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-931x2048.webp 931w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-scaled.webp 1164w\" sizes=\"(max-width: 465px) 100vw, 465px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6a72395 e-con-full e-flex e-con e-child\" data-id=\"6a72395\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1a711e6 elementor-widget elementor-widget-heading\" data-id=\"1a711e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pre\u010do si vybra\u0165 <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e791ed8 elementor-widget elementor-widget-text-editor\" data-id=\"e791ed8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Str\u00e1nka <strong data-start=\"4377\" data-end=\"4408\">sk\u00fa\u0161ka \u00faniku kvapaliny z injek\u010dnej strieka\u010dky<\/strong> je nevyhnutn\u00fd na overenie integrity injek\u010dn\u00fdch strieka\u010diek vo farmaceutickom priemysle. V s\u00falade s usmerneniami stanoven\u00fdmi <strong data-start=\"4527\" data-end=\"4549\">ISO 7886-1 Pr\u00edloha D<\/strong> a <strong data-start=\"4554\" data-end=\"4578\">ISO 11040-4 Pr\u00edloha G2<\/strong> zabezpe\u010duje s\u00falad, spo\u013eahlivos\u0165 v\u00fdrobku a bezpe\u010dnos\u0165 pacienta. Trust <strong data-start=\"4646\" data-end=\"4666\">Mobiln\u00e9 n\u00e1stroje<\/strong> pre odborn\u00e9 testovacie rie\u0161enia a prisp\u00f4soben\u00fa podporu na zlep\u0161enie va\u0161ich procesov kontroly kvality injek\u010dn\u00fdch strieka\u010diek.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c65166e elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"c65166e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/sk\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontaktujte n\u00e1s<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Syringe Closure System Liquid Leakage Test In the pharmaceutical and medical device industries, ensuring the integrity of syringes is crucial for product safety and patient health. One of the most essential procedures is the syringe liquid leakage test, which evaluates the ability of a syringe\u2019s plunger and closure system to prevent liquid leaks under pressure. [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-492","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/pages\/492","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/comments?post=492"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/pages\/492\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/media?parent=492"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}