{"id":298,"date":"2025-05-06T07:03:47","date_gmt":"2025-05-06T07:03:47","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=298"},"modified":"2026-05-14T08:26:56","modified_gmt":"2026-05-14T08:26:56","slug":"pull-off-force-of-the-tip-cap-or-the-needle-shield","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/sk\/pull-off-force-of-the-tip-cap-or-the-needle-shield","title":{"rendered":"Sila od\u0165ahu krytu hrotu alebo \u0161t\u00edtu ihly"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"298\" class=\"elementor elementor-298\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3dce31e e-flex e-con-boxed e-con e-parent\" data-id=\"3dce31e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4ace088 elementor-widget elementor-widget-heading\" data-id=\"4ace088\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Sila od\u0165ahu krytu hrotu alebo \u0161t\u00edtu ihly<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-879fa28 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"879fa28\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Vo farmaceutickom a lek\u00e1rskom priemysle sa <strong>sila od\u0165ahu krytu hrotu alebo \u0161t\u00edtu ihly<\/strong> zohr\u00e1va d\u00f4le\u017eit\u00fa \u00falohu pri zabezpe\u010dovan\u00ed integrity, pou\u017eite\u013enosti a bezpe\u010dnosti predplnen\u00fdch injek\u010dn\u00fdch strieka\u010diek. Presn\u00e9 meranie a kontrola tohto parametra priamo ovplyv\u0148uj\u00fa spo\u013eahlivos\u0165 v\u00fdrobku a bezpe\u010dnos\u0165 pacienta. Pre odborn\u00edkov, ktor\u00ed sa podie\u013eaj\u00fa na kontrole kvality injek\u010dn\u00fdch strieka\u010diek, je d\u00f4le\u017eit\u00e9 pochopi\u0165, ako spr\u00e1vne vyhodnoti\u0165 silu od\u0165ahu - v s\u00falade s <strong>ISO 11040-4<\/strong> a <strong>ISO 11040-4 Pr\u00edloha G5<\/strong> normy - je nevyhnutn\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0ce9476 e-flex e-con-boxed e-con e-parent\" data-id=\"0ce9476\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eb4d8a9 elementor-widget elementor-widget-heading\" data-id=\"eb4d8a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00f4le\u017eitos\u0165 sily od\u0165ahu krytu hrotu alebo \u0161t\u00edtu ihly<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1cc60b7 elementor-widget elementor-widget-text-editor\" data-id=\"1cc60b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Str\u00e1nka <strong>sila od\u0165ahu krytu hrotu alebo \u0161t\u00edtu ihly<\/strong> sa vz\u0165ahuje na silu potrebn\u00fa na odstr\u00e1nenie ochrann\u00e9ho krytu z hrotu strieka\u010dky alebo ihly pred pou\u017eit\u00edm.<br \/>Spr\u00e1vne kalibrovan\u00e1 sila od\u0165ahu zabezpe\u010duje:<\/p><ul><li>Jednoduch\u00e9 odstr\u00e1nenie bez pou\u017eitia nadmernej sily<\/li><li>Ochrana proti n\u00e1hodn\u00e9mu uvo\u013eneniu po\u010das prepravy alebo skladovania<\/li><li>Zachovanie sterility a\u017e do miesta pou\u017eitia<\/li><\/ul><p>Ak je sila vytiahnutia pr\u00edli\u0161 n\u00edzka, m\u00f4\u017ee to ohrozi\u0165 bezpe\u010dnos\u0165 v\u00fdrobku. Naopak, ak je pr\u00edli\u0161 ve\u013ek\u00e1, m\u00f4\u017ee br\u00e1ni\u0165 pou\u017eite\u013enosti, najm\u00e4 v klinick\u00fdch podmienkach, kde je rozhoduj\u00faca r\u00fdchlos\u0165 a jednoduchos\u0165.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc4154b e-flex e-con-boxed e-con e-parent\" data-id=\"dc4154b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5983954 elementor-widget elementor-widget-heading\" data-id=\"5983954\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pre\u010do s\u00fa normy ISO 11040-4 a ISO 11040-4 pr\u00edloha G5 kritick\u00e9 pre testovanie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1c51fe9 e-con-full e-flex e-con e-child\" data-id=\"1c51fe9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-53b605e elementor-widget elementor-widget-text-editor\" data-id=\"53b605e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Medzin\u00e1rodn\u00e9 normy, ako napr. <a href=\"https:\/\/www.syringetest.com\/sk\/standards\/iso-11040-4\/\"><strong>ISO 11040-4<\/strong><\/a> a najm\u00e4 <strong>ISO 11040-4 Pr\u00edloha G5<\/strong> poskytuj\u00fa podrobn\u00e9 metodiky na hodnotenie kritick\u00fdch komponentov predplnen\u00fdch injek\u010dn\u00fdch strieka\u010diek vr\u00e1tane krytu hrotu a \u0161t\u00edtu ihly.<\/p><p>Tieto normy stanovuj\u00fa:<\/p><ul><li>Po\u017eiadavky na sk\u00fa\u0161obn\u00fd pr\u00edstroj<\/li><li>Podmienky testovania a manipul\u00e1cia so vzorkami<\/li><li>Pokyny na zaznamen\u00e1vanie a interpret\u00e1ciu \u00fadajov<\/li><\/ul><p>Dodr\u017eiavan\u00edm t\u00fdchto protokolov v\u00fdrobcovia a agent\u00fary pre kontrolu kvality zabezpe\u010duj\u00fa konzistentn\u00e9, reprodukovate\u013en\u00e9 a medzin\u00e1rodne uzn\u00e1van\u00e9 v\u00fdsledky. <strong>Syringetest.com<\/strong>\u00a0sa \u0161pecializuje na poskytovanie presn\u00fdch testovac\u00edch zariaden\u00ed, ktor\u00e9 s\u00fa v s\u00falade s t\u00fdmito normami, \u010d\u00edm zabezpe\u010duje optim\u00e1lny v\u00fdkon pri vyhodnocovan\u00ed va\u0161ich injek\u010dn\u00fdch strieka\u010diek.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68fc685 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"68fc685\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"234\" height=\"300\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5-234x300.webp\" class=\"attachment-medium size-medium wp-image-290\" alt=\"Sila od\u0165ahu krytu hrotu alebo \u0161t\u00edtu ihly - ISO 11040-4 pr\u00edloha G5\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5-234x300.webp 234w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp 320w\" sizes=\"(max-width: 234px) 100vw, 234px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e7cb14b e-flex e-con-boxed e-con e-parent\" data-id=\"e7cb14b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eb7acec elementor-widget elementor-widget-heading\" data-id=\"eb7acec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vybavenie potrebn\u00e9 na vytiahnutie \u0161pi\u010dkovej \u010diapky alebo ihlov\u00e9ho \u0161t\u00edtu<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc30e9d e-con-full e-flex e-con e-child\" data-id=\"dc30e9d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-721bd9d elementor-widget elementor-widget-image\" data-id=\"721bd9d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"320\" height=\"410\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp\" class=\"attachment-large size-large wp-image-290\" alt=\"Sila od\u0165ahu krytu hrotu alebo \u0161t\u00edtu ihly - ISO 11040-4 pr\u00edloha G5\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp 320w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5-234x300.webp 234w\" sizes=\"(max-width: 320px) 100vw, 320px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4543b33 elementor-widget elementor-widget-text-editor\" data-id=\"4543b33\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Na presn\u00e9 testovanie <strong>sila od\u0165ahu krytu hrotu alebo \u0161t\u00edtu ihly<\/strong>, je potrebn\u00e9 \u0161pecializovan\u00e9 testovacie zariadenie. Typick\u00e9 nastavenie zah\u0155\u0148a:<\/p><ul><li>Univerz\u00e1lny sk\u00fa\u0161obn\u00fd stroj so sn\u00edma\u010dom sily vhodn\u00fd na merania s n\u00edzkym rozsahom<\/li><li>Ch\u00e1padl\u00e1 navrhnut\u00e9 tak, aby bezpe\u010dne dr\u017eali injek\u010dn\u00fa strieka\u010dku a uz\u00e1ver bez sk\u013aznutia alebo deform\u00e1cie<\/li><li>Syst\u00e9m zberu \u00fadajov s odpor\u00fa\u010danou vzorkovacou frekvenciou aspo\u0148 100 Hz (na detekciu \u0161pi\u010dkovej sily sa uprednost\u0148uje 500 Hz).<\/li><\/ul><p>Na str\u00e1nke <strong>Syringetest.com<\/strong>, pon\u00fakame vysoko presn\u00e9 testery s\u0165ahovacej sily nakonfigurovan\u00e9 \u0161peci\u00e1lne na splnenie <strong>ISO 11040-4 Pr\u00edloha G5<\/strong> po\u017eiadavky.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b172ef4 e-flex e-con-boxed e-con e-parent\" data-id=\"b172ef4\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0a1cba7 elementor-widget elementor-widget-heading\" data-id=\"0a1cba7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Sk\u00fa\u0161obn\u00e1 met\u00f3da pod\u013ea ISO 11040-5 pr\u00edloha G5<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-86d3c07 elementor-widget elementor-widget-text-editor\" data-id=\"86d3c07\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Proces testovania zah\u0155\u0148a nieko\u013eko d\u00f4le\u017eit\u00fdch krokov:<\/p><h3>Pr\u00edprava vzorky<\/h3><ul><li>Pou\u017e\u00edvajte sterilizovan\u00e9 podomontovan\u00e9 injek\u010dn\u00e9 strieka\u010dky pripraven\u00e9 na plnenie pod\u013ea v\u00fdrobn\u00fdch \u0161pecifik\u00e1ci\u00ed.<\/li><li>Uistite sa, \u017ee vzorky pre\u0161li rovnak\u00fdmi podmienkami manipul\u00e1cie a skladovania ako v\u00fdrobn\u00e9 \u0161ar\u017ee.<\/li><\/ul><h3>Postup testovania<\/h3><ul><li>Injek\u010dn\u00fa strieka\u010dku upevnite do testovacieho pr\u00edpravku vo zvislej polohe.<\/li><li>Zabezpe\u010dte kryt hrotu alebo \u0161t\u00edt ihly pomocou vhodn\u00e9ho uchopovacieho mechanizmu.<\/li><li>Vynulujte syst\u00e9m merania sily, aby ste eliminovali \u00fa\u010dinky predbe\u017en\u00e9ho za\u0165a\u017eenia.<\/li><li>Pou\u017eite rovnomern\u00fa \u0165ahov\u00fa silu smerom nahor pri kontrolovanej r\u00fdchlosti (zvy\u010dajne 20 mm\/min, ale m\u00f4\u017ee sa l\u00ed\u0161i\u0165 pod\u013ea \u0161pecifik\u00e1cie strieka\u010dky).<\/li><li>Priebe\u017ene merajte a zaznamen\u00e1vajte silu, k\u00fdm sa uz\u00e1ver alebo \u0161t\u00edt neoddel\u00ed od strieka\u010dky.<\/li><\/ul><h3>Interpret\u00e1cia \u00fadajov<\/h3><ul><li>Maxim\u00e1lna sila zaznamenan\u00e1 po\u010das odde\u013eovacej udalosti predstavuje hodnotu odtrhovacej sily.<\/li><li>Porovnanie z\u00edskan\u00fdch v\u00fdsledkov s vopred definovan\u00fdmi krit\u00e9riami akceptovate\u013enosti na z\u00e1klade n\u00e1vrhu v\u00fdrobku a \u0161pecifik\u00e1ci\u00ed z\u00e1kazn\u00edka.<\/li><\/ul><h3>K\u013e\u00fa\u010dov\u00e9 \u00favahy a osved\u010den\u00e9 postupy<\/h3><ul><li><strong>Vzorkovacia frekvencia:<\/strong> Ak je to mo\u017en\u00e9, udr\u017eujte vzorkovaciu frekvenciu minim\u00e1lne 500 Hz, aby ste dosiahli presnos\u0165 maxim\u00e1lnej sily.<\/li><li><strong>Dizajn svietidiel:<\/strong> Uistite sa, \u017ee uchopovac\u00ed pr\u00edpravok po\u010das testovania nestla\u010d\u00ed ani nedeformuje injek\u010dn\u00fa strieka\u010dku.<\/li><li><strong>\u017divotn\u00e9 prostredie:<\/strong> Ak nie je uveden\u00e9 inak, vykonajte testovanie za \u0161tandardn\u00fdch laborat\u00f3rnych podmienok (teplota, vlhkos\u0165).<\/li><li><strong>Dokument\u00e1cia:<\/strong> V spr\u00e1ve o sk\u00fa\u0161ke uve\u010fte v\u0161etky parametre sk\u00fa\u0161ky, v\u00fdsledky, mno\u017estv\u00e1 vzoriek a v\u0161etky odch\u00fdlky.<\/li><\/ul><p>Dodr\u017eiavanie uveden\u00fdch postupov zaru\u010duje spo\u013eahliv\u00e9 v\u00fdsledky, je v s\u00falade s <strong>ISO 11040-4 Pr\u00edloha G5<\/strong>a posil\u0148uje z\u00e1ruky zhody v\u00fdrobkov a bezpe\u010dnosti pacientov.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-01682de e-flex e-con-boxed e-con e-parent\" data-id=\"01682de\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4faf7c0 elementor-widget elementor-widget-heading\" data-id=\"4faf7c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Aplik\u00e1cie a v\u00fdznam testovania sily od\u0165ahu<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0eae829 elementor-widget elementor-widget-text-editor\" data-id=\"0eae829\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Testovanie <strong>sila od\u0165ahu krytu hrotu alebo \u0161t\u00edtu ihly<\/strong> je ve\u013emi d\u00f4le\u017eit\u00fd pre:<\/p><ul><li>V\u00fdrobcovia predplnen\u00fdch injek\u010dn\u00fdch strieka\u010diek<\/li><li>Laborat\u00f3ri\u00e1 na kontrolu kvality zdravotn\u00edckych pom\u00f4cok<\/li><li>V\u00fdvoj\u00e1ri farmaceutick\u00fdch obalov<\/li><li>Procesy dodr\u017eiavania predpisov a certifik\u00e1cie<\/li><\/ul><p>Zaisten\u00edm spr\u00e1vnych s\u00edl pri od\u0165ahovan\u00ed v\u00fdrobcovia zvy\u0161uj\u00fa pou\u017eite\u013enos\u0165 v\u00fdrobku, spokojnos\u0165 pacientov a akcept\u00e1ciu zo strany regula\u010dn\u00fdch org\u00e1nov, \u010do priamo prispieva k spo\u013eahlivosti zna\u010dky a \u00faspechu na trhu.<\/p><p><strong>Syringetest.com<\/strong> poskytuje najmodernej\u0161ie, prisp\u00f4sobite\u013en\u00e9 testovacie rie\u0161enia na splnenie r\u00f4znych potrieb v oblasti testovania injek\u010dn\u00fdch strieka\u010diek a zdravotn\u00edckych pom\u00f4cok. Na\u0161e pr\u00edstroje s\u00fa navrhnut\u00e9 tak, aby podporovali pr\u00edsne po\u017eiadavky na kvalitu v oblasti balenia, farmaceutick\u00e9ho priemyslu a zdravotn\u00edctva.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-46145eb e-grid e-con-full e-con e-parent\" data-id=\"46145eb\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5f14311 elementor-widget elementor-widget-image\" data-id=\"5f14311\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fc27b7b e-con-full e-flex e-con e-child\" data-id=\"fc27b7b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-59f47a7 elementor-widget elementor-widget-heading\" data-id=\"59f47a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pre\u010do si vybra\u0165 <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d125c4 elementor-widget elementor-widget-text-editor\" data-id=\"7d125c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pochopenie a presn\u00e9 meranie <strong>sila od\u0165ahu krytu hrotu alebo \u0161t\u00edtu ihly<\/strong>, ktor\u00e9 sa riadia normami, ako napr. <strong>ISO 11040-4<\/strong> a <strong>ISO 11040-4 Pr\u00edloha G5<\/strong>, je ve\u013emi d\u00f4le\u017eit\u00fd na zaistenie bezpe\u010dnosti, pou\u017eite\u013enosti a s\u00faladu predplnen\u00fdch injek\u010dn\u00fdch strieka\u010diek s predpismi. Spoliehanie sa na presn\u00e9 n\u00e1stroje od <strong>Syringetest.com<\/strong>\u00a0zabezpe\u010d\u00ed, \u017ee va\u0161e testovanie bude efekt\u00edvne, presn\u00e9 a plne v s\u00falade s glob\u00e1lnymi normami.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eade606 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"eade606\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/sk\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontaktujte n\u00e1s<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Pull-Off Force of The Tip Cap or The Needle Shield In the pharmaceutical and medical industries, the pull-off force of the tip cap or the needle shield plays a vital role in ensuring the integrity, usability, and safety of prefilled syringes. Accurate measurement and control of this parameter directly affect product reliability and patient safety. [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-298","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/pages\/298","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/comments?post=298"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/pages\/298\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/media?parent=298"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}