{"id":288,"date":"2025-05-06T06:58:13","date_gmt":"2025-05-06T06:58:13","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=288"},"modified":"2026-05-09T06:47:27","modified_gmt":"2026-05-09T06:47:27","slug":"luer-lock-rigid-tip-cap-unscrewing-torque","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/sk\/luer-lock-rigid-tip-cap-unscrewing-torque","title":{"rendered":"Moment odskrutkovania pevn\u00e9ho uz\u00e1veru Luer Lock"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"288\" class=\"elementor elementor-288\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ff288b4 e-flex e-con-boxed e-con e-parent\" data-id=\"ff288b4\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-49f41f0 elementor-widget elementor-widget-heading\" data-id=\"49f41f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Moment odskrutkovania pevn\u00e9ho uz\u00e1veru Luer Lock<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b1aaa54 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"b1aaa54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>V oblasti v\u00fdroby zdravotn\u00edckych pom\u00f4cok <strong>Moment odskrutkovania pevn\u00e9ho uz\u00e1veru luer lock<\/strong> test zohr\u00e1va d\u00f4le\u017eit\u00fa \u00falohu pri overovan\u00ed pou\u017eite\u013enosti a bezpe\u010dnosti predplnen\u00fdch injek\u010dn\u00fdch strieka\u010diek. Tento kritick\u00fd test zabezpe\u010duje, \u017ee pevn\u00fd uz\u00e1ver hrotu sa d\u00e1 odstr\u00e1ni\u0165 vhodn\u00fdm kr\u00fatiacim momentom, \u010d\u00edm sa zabezpe\u010d\u00ed funk\u010dnos\u0165 aj bezpe\u010dnos\u0165 pacienta. Presn\u00e9 testovanie je nevyhnutn\u00e9 na dosiahnutie s\u00faladu s medzin\u00e1rodn\u00fdmi normami a na udr\u017eanie vysokej kvality v\u00fdroby, ktor\u00e1 sa o\u010dak\u00e1va v zdravotn\u00edckom priemysle.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-58bdb3e e-flex e-con-boxed e-con e-parent\" data-id=\"58bdb3e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-659fb04 elementor-widget elementor-widget-heading\" data-id=\"659fb04\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00fdznam testovania pevn\u00e9ho uz\u00e1veru Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f56c4d elementor-widget elementor-widget-text-editor\" data-id=\"8f56c4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Spr\u00e1vne vykonanie tohto testu zabezpe\u010duje:<\/p><ul><li><strong>Bezpe\u010dnos\u0165 pacientov<\/strong>: Zabezpe\u010denie toho, aby uz\u00e1very neboli ani pr\u00edli\u0161 tesn\u00e9, ani pr\u00edli\u0161 vo\u013en\u00e9, chr\u00e1ni pacientov pred kontamin\u00e1ciou alebo probl\u00e9mami s pou\u017eite\u013enos\u0165ou.<\/li><li><strong>Dodr\u017eiavanie pr\u00e1vnych predpisov<\/strong>: Splnenie noriem ISO 11040-4 je rozhoduj\u00face pre pr\u00edstup na trh a prijatie v\u00fdrobku.<\/li><li><strong>Konzistentnos\u0165 produktu<\/strong>: Testovanie podporuje konzistentn\u00e9 v\u00fdrobn\u00e9 procesy, zni\u017euje po\u010det ch\u00fdb a zabezpe\u010duje spo\u013eahlivos\u0165 \u0161ar\u017e\u00ed.<\/li><\/ul><p>Odborn\u00e9 znalosti spolo\u010dnosti Syringetest.com v oblasti testovania materi\u00e1lov a prisp\u00f4soben\u00fdch rie\u0161en\u00ed zabezpe\u010duj\u00fa, \u017ee v\u00fdrobcovia injek\u010dn\u00fdch strieka\u010diek m\u00f4\u017eu \u00fa\u010dinne splni\u0165 tieto pr\u00edsne po\u017eiadavky na testovanie, \u010d\u00edm sa zvy\u0161uje kvalita v\u00fdrobkov a ich konkurencieschopnos\u0165 na trhu.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-de73fea e-flex e-con-boxed e-con e-parent\" data-id=\"de73fea\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e6ff1ae elementor-widget elementor-widget-heading\" data-id=\"e6ff1ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 a ISO 11040-4 pr\u00edloha G5 Po\u017eiadavky<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-308b5c9 e-con-full e-flex e-con e-child\" data-id=\"308b5c9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5d88b36 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"5d88b36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.syringetest.com\/sk\/standards\/iso-11040-4\/\">ISO 11040-4<\/a> a jej pr\u00edloha G5 uv\u00e1dzaj\u00fa podrobn\u00e9 postupy a po\u017eiadavky na pr\u00edstroje na hodnotenie <strong>Moment odskrutkovania pevn\u00e9ho uz\u00e1veru luer lock<\/strong>. Tieto usmernenia zabezpe\u010duj\u00fa konzistentn\u00e9 a spo\u013eahliv\u00e9 testovanie v celom odvetv\u00ed.<\/p><p>Pod\u013ea <strong>ISO 11040-4 Pr\u00edloha G5<\/strong>, \u00fa\u010delom tohto testu je pos\u00fadi\u0165 kr\u00fatiaci moment potrebn\u00fd na odskrutkovanie pevn\u00e9ho uz\u00e1veru hrotu zo sterilizovan\u00fdch s\u00faprav injek\u010dn\u00fdch strieka\u010diek pripraven\u00fdch na plnenie. Cie\u013eom je overi\u0165, \u010di kr\u00fatiaci moment pri odstra\u0148ovan\u00ed uz\u00e1veru spad\u00e1 do prijate\u013en\u00fdch hran\u00edc, \u010di nie je pr\u00edli\u0161 vysok\u00fd (\u010do by mohlo br\u00e1ni\u0165 pou\u017eite\u013enosti), ani pr\u00edli\u0161 n\u00edzky (\u010do by mohlo ohrozi\u0165 sterilitu).<\/p><p>V pr\u00edlohe sa uv\u00e1dza potreba:<\/p><ul><li>A <strong>tester kr\u00fatiaceho momentu<\/strong> vybaven\u00e1 rota\u010dn\u00fdm zariaden\u00edm.<\/li><li>A <strong>kr\u00fatiaci momentov\u00fd \u010dl\u00e1nok<\/strong> s kapacitou 35 Ncm a rozl\u00ed\u0161en\u00edm 0,05 Ncm alebo lep\u0161\u00edm.<\/li><li>A <strong>r\u00fdchlos\u0165 ot\u00e1\u010dania<\/strong> 20 ot\u00e1\u010dok za min\u00fatu (ot\/min), nastavite\u013en\u00e9 na z\u00e1klade dohody medzi v\u00fdrobcom a z\u00e1kazn\u00edkom.<\/li><li>\u0160pecializovan\u00e9 pr\u00edslu\u0161enstvo, ako napr. <strong>uchopova\u010d vrchn\u00e1ka<\/strong> a <strong>dr\u017eiak injek\u010dnej strieka\u010dky<\/strong>.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a858e71 elementor-widget elementor-widget-image\" data-id=\"a858e71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"320\" height=\"410\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp\" class=\"attachment-large size-large wp-image-290\" alt=\"Sila od\u0165ahu krytu hrotu alebo \u0161t\u00edtu ihly - ISO 11040-4 pr\u00edloha G5\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp 320w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5-234x300.webp 234w\" sizes=\"(max-width: 320px) 100vw, 320px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b28ec18 e-flex e-con-boxed e-con e-parent\" data-id=\"b28ec18\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-197dd31 elementor-widget elementor-widget-heading\" data-id=\"197dd31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Postup testovania kr\u00fatiaceho momentu pri odskrutkovan\u00ed pevn\u00e9ho uz\u00e1veru Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b15e179 elementor-widget elementor-widget-text-editor\" data-id=\"b15e179\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Vykon\u00e1vanie <strong>Moment odskrutkovania pevn\u00e9ho uz\u00e1veru luer lock<\/strong> test zah\u0155\u0148a nieko\u013eko presn\u00fdch krokov:<\/p><h3>Pr\u00edprava vzorky<\/h3><p>Vyberte sterilizovan\u00e9 submontovan\u00e9 injek\u010dn\u00e9 strieka\u010dky, ktor\u00e9 zodpovedaj\u00fa v\u00fdrobn\u00e9mu procesu. Spr\u00e1vna manipul\u00e1cia so vzorkami zabezpe\u010d\u00ed, \u017ee v\u00fdsledky bud\u00fa presne zodpoveda\u0165 kvalite v\u00fdroby.<\/p><h3>Nastavenie zariadenia<\/h3><ul><li>Injek\u010dn\u00fa strieka\u010dku upevnite vertik\u00e1lne do <strong>dr\u017eiak injek\u010dnej strieka\u010dky<\/strong> testovacieho zariadenia.<\/li><li>Pripojte <strong>adapt\u00e9r<\/strong> (uchopova\u010d uz\u00e1veru hrotu) na uz\u00e1ver hrotu bezpe\u010dne bez pou\u017eitia predbe\u017en\u00e9ho kr\u00fatiaceho momentu.<\/li><li>Na zabezpe\u010denie z\u00e1kladnej presnosti nastavte bunku kr\u00fatiaceho momentu na \"nulu\".<\/li><li>Nastavte ot\u00e1\u010dacie zariadenie na 20 ot\u00e1\u010dok za min\u00fatu alebo na dohodnut\u00fa r\u00fdchlos\u0165.<\/li><\/ul><h3>Postup testovania<\/h3><ul><li>V z\u00e1vislosti od po\u017eiadaviek syst\u00e9mu spustite ot\u00e1\u010danie v smere alebo proti smeru hodinov\u00fdch ru\u010di\u010diek.<\/li><li>Udr\u017eujte rovnomern\u00e9 ot\u00e1\u010danie, k\u00fdm sa neza\u010dne odskrutkova\u0165 uz\u00e1ver hrotu.<\/li><li>Zaznamenajte <strong>maxim\u00e1lny kr\u00fatiaci moment<\/strong> sa pou\u017eije v okamihu, ke\u010f sa uz\u00e1ver za\u010dne pohybova\u0165.<\/li><\/ul><p>Je nevyhnutn\u00e9 zabezpe\u010di\u0165 <strong>vysok\u00e1 vzorkovacia frekvencia<\/strong> po\u010das testovania. V pr\u00edlohe G5 sa odpor\u00fa\u010da vzorkovacia frekvencia 500 Hz pre testy, ktor\u00e9 vy\u017eaduj\u00fa meranie \u0161pi\u010dkov\u00e9ho kr\u00fatiaceho momentu, \u010d\u00edm sa zvy\u0161uje presnos\u0165 \u00fadajov.<\/p><h3>Vyjadrenie v\u00fdsledkov<\/h3><p>Po dokon\u010den\u00ed testu zdokumentujte nasleduj\u00face \u00fadaje:<\/p><ul><li>Maxim\u00e1lny dosiahnut\u00fd kr\u00fatiaci moment (v Ncm).<\/li><li>R\u00fdchlos\u0165 ot\u00e1\u010dania pou\u017eit\u00e1 po\u010das testovania.<\/li><li>Po\u010det testovan\u00fdch vzoriek a po\u010det vyhovuj\u00facich alebo nevyhovuj\u00facich vzoriek pod\u013ea \u0161pecifik\u00e1ci\u00ed.<\/li><li>V\u0161etky odch\u00fdlky, anom\u00e1lie alebo pozorovania zaznamenan\u00e9 po\u010das testovania.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9ee2543 e-grid e-con-full e-con e-parent\" data-id=\"9ee2543\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-896974c elementor-widget elementor-widget-image\" data-id=\"896974c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-49cfbb3 e-con-full e-flex e-con e-child\" data-id=\"49cfbb3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1acd247 elementor-widget elementor-widget-heading\" data-id=\"1acd247\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pre\u010do si vybra\u0165 <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2c455c elementor-widget elementor-widget-text-editor\" data-id=\"f2c455c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"203\" data-end=\"463\">Na str\u00e1nke <strong>Syringetest.com<\/strong>, sp\u00e1jame odborn\u00e9 znalosti, inov\u00e1cie, od prec\u00edzneho in\u017einierstva a\u017e po individu\u00e1lne slu\u017eby na podporu na\u0161ich z\u00e1kazn\u00edkov na celom svete.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5784c2f elementor-widget elementor-widget-text-editor\" data-id=\"5784c2f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Str\u00e1nka <strong>Moment odskrutkovania pevn\u00e9ho uz\u00e1veru luer lock<\/strong> test, ako je definovan\u00fd <strong>ISO 11040-4 Pr\u00edloha G5<\/strong>, je nevyhnutn\u00e9 na udr\u017eanie kvality injek\u010dn\u00fdch strieka\u010diek a zabezpe\u010denie s\u00faladu s glob\u00e1lnymi normami. V\u010faka spr\u00e1vnemu vybaveniu a spr\u00e1vnym testovac\u00edm postupom m\u00f4\u017eu v\u00fdrobcovia s istotou overova\u0165 pou\u017eite\u013enos\u0165 svojich v\u00fdrobkov z injek\u010dn\u00fdch strieka\u010diek. D\u00f4verujte spolo\u010dnosti Syringetest.com, ktor\u00e1 poskytuje presn\u00e9 testovacie rie\u0161enia prisp\u00f4soben\u00e9 va\u0161im potreb\u00e1m a pom\u00e1ha v\u00e1m dodr\u017eiava\u0165 najvy\u0161\u0161ie \u0161tandardy bezpe\u010dnosti a kvality.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ecae3d1 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"ecae3d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/sk\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontaktujte n\u00e1s<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Rigid Tip Cap Unscrewing Torque In the field of medical device manufacturing, the luer lock rigid tip cap unscrewing torque test plays a vital role in verifying the usability and safety of prefilled syringes. This critical test ensures that the rigid tip cap can be removed with appropriate torque, safeguarding both functionality and [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-288","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/pages\/288","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/comments?post=288"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/pages\/288\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/sk\/wp-json\/wp\/v2\/media?parent=288"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}