{"id":277,"date":"2025-05-06T05:39:02","date_gmt":"2025-05-06T05:39:02","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=277"},"modified":"2026-05-09T06:43:14","modified_gmt":"2026-05-09T06:43:14","slug":"luer-lock-adaptor-collar-torque-resistance","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/ro\/luer-lock-adaptor-collar-torque-resistance","title":{"rendered":"Rezisten\u021ba la torsiune a colierului adaptor Luer Lock"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"277\" class=\"elementor elementor-277\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ba8e23f e-flex e-con-boxed e-con e-parent\" data-id=\"ba8e23f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5a6414a elementor-widget elementor-widget-heading\" data-id=\"5a6414a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Rezisten\u021ba la torsiune a colierului adaptor Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-43ca76c elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"43ca76c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00cen\u021belegerea <strong>guler adaptor luer lock rezisten\u021b\u0103 la cuplu<\/strong> este esen\u021bial pentru asigurarea calit\u0103\u021bii \u0219i fiabilit\u0103\u021bii ansamblurilor de seringi preumplute. Acest test verific\u0103 capacitatea gulerului adaptorului Luer Lock (LLA) de a rezista for\u021belor de rota\u021bie atunci c\u00e2nd este ata\u0219at un accesoriu Luer, cum ar fi un ac. Asigurarea faptului c\u0103 seringile dvs. \u00eendeplinesc standardele de performan\u021b\u0103 nu \u00eenseamn\u0103 doar conformitate - \u00eenseamn\u0103 protejarea utilizatorilor finali \u0219i men\u021binerea reputa\u021biei m\u0103rcii dvs.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc76c2b e-flex e-con-boxed e-con e-parent\" data-id=\"dc76c2b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8a65884 elementor-widget elementor-widget-heading\" data-id=\"8a65884\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Importan\u021ba test\u0103rii rezisten\u021bei la torsiune a colierului adaptorului Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c41e388 elementor-widget elementor-widget-text-editor\" data-id=\"c41e388\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong>guler adaptor luer lock rezisten\u021b\u0103 la cuplu<\/strong> evalueaz\u0103 stabilitatea mecanic\u0103 a gulerului LLA al seringii \u00een condi\u021bii de torsiune. Dac\u0103 gulerul cedeaz\u0103 \u00een timpul sau dup\u0103 fixarea acului, pot ap\u0103rea consecin\u021be grave, cum ar fi scurgeri, erori de dozare sau chiar r\u0103niri.<\/p><p>Prin efectuarea acestui test, produc\u0103torii se pot asigura c\u0103:<\/p><ul><li>Durabilitatea mecanic\u0103 a seringii \u00een timpul utiliz\u0103rii clinice.<\/li><li>Conformitatea cu standardele interna\u021bionale de calitate, cum ar fi <a href=\"https:\/\/www.syringetest.com\/ro\/iso-11040-4\/\"><strong>ISO 11040-4<\/strong><\/a>.<\/li><li>Satisfac\u021bie mai mare a clien\u021bilor \u0219i mai pu\u021bine rechem\u0103ri ale produselor.<\/li><li>Administrarea mai sigur\u0103 a medicamentelor pentru cadrele medicale \u0219i pacien\u021bi.<\/li><\/ul><p>Testarea acestei propriet\u0103\u021bi este vital\u0103 \u00een special pentru seringile subansamblate sterilizate preg\u0103tite pentru umplere, asigur\u00e2ndu-se c\u0103 produsul \u00ee\u0219i p\u0103streaz\u0103 integritatea de la fabrica\u021bie p\u00e2n\u0103 la administrare.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-32d8f5e e-flex e-con-boxed e-con e-parent\" data-id=\"32d8f5e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-243d149 elementor-widget elementor-widget-heading\" data-id=\"243d149\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Anexa G4 Cerin\u021be pentru testarea rezisten\u021bei la cuplu<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-42454a3 elementor-widget elementor-widget-text-editor\" data-id=\"42454a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong>ISO 11040-4 Anexa G4<\/strong> sec\u021biunea prezint\u0103 \u00een mod specific modul de desf\u0103\u0219urare a <strong>guler adaptor luer lock rezisten\u021b\u0103 la cuplu<\/strong> \u00eentr-un mod coerent \u0219i standardizat. Iat\u0103 o prezentare general\u0103 a elementelor esen\u021biale:<\/p><h3>Principiul<\/h3><p>Metoda evalueaz\u0103 dac\u0103 gulerul LLA poate rezista la o for\u021b\u0103 de rota\u021bie aplicat\u0103 \u00een timpul conect\u0103rii unui fiting Luer. Gulerul trebuie s\u0103 r\u0103m\u00e2n\u0103 fixat f\u0103r\u0103 a se mi\u0219ca excesiv sau a se desprinde.<\/p><h3>Materiale \u0219i aparate<\/h3><ul><li><strong>E\u0219antioane de testare<\/strong>: Seringi subansamblate sterilizate preg\u0103tite pentru umplere cu LLA.<\/li><li><strong>Tester de cuplu<\/strong>: Echipat cu un dispozitiv de rota\u021bie capabil s\u0103 efectueze 20 de rota\u021bii pe minut.<\/li><li><strong>Senzor de cuplu<\/strong>: Capacitate de 35 Ncm cu rezolu\u021bie de 0,05 Ncm.<\/li><li><strong>Rata de e\u0219antionare<\/strong>: 500 Hz recomandat pentru m\u0103sur\u0103tori de v\u00e2rf.<\/li><\/ul><p>Este important s\u0103 utiliza\u021bi echipamente calibrate pentru a asigura acurate\u021bea m\u0103sur\u0103torilor. Solu\u021biile de testare a cuplului de la Syringetest.com ofer\u0103 rate ridicate de e\u0219antionare \u0219i o achizi\u021bie fiabil\u0103 a datelor pentru a satisface aceste nevoi.<\/p><h3>Preg\u0103tirea e\u0219antioanelor de testare<\/h3><p>E\u0219antioanele de testare trebuie s\u0103 fie manipulate \u00een acelea\u0219i condi\u021bii ca \u0219i produsul final livrat. Consecven\u021ba asigur\u0103 c\u0103 rezultatele testelor reflect\u0103 cu exactitate performan\u021bele din lumea real\u0103.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fe46b5f e-flex e-con-boxed e-con e-parent\" data-id=\"fe46b5f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1c58ff4 elementor-widget elementor-widget-heading\" data-id=\"1c58ff4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procedura de testare pas cu pas<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf42e77 elementor-widget elementor-widget-text-editor\" data-id=\"bf42e77\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Efectuarea unei <strong>guler adaptor luer lock rezisten\u021b\u0103 la cuplu<\/strong> test \u00een conformitate cu <strong>ISO 11040-4 Anexa G4<\/strong> implic\u0103 urm\u0103torii pa\u0219i:<\/p><ol><li><strong>Configurarea e\u0219antionului<\/strong>: Introduce\u021bi seringa sterilizat\u0103 vertical \u00een suportul seringii.<\/li><li><strong>\u00cendep\u0103rtarea capacului v\u00e2rfului<\/strong>: \u00cendep\u0103rta\u021bi manual cu aten\u021bie capacul v\u00e2rfului pentru a evita aplicarea unui pretensionare.<\/li><li><strong>Montarea dispozitivului de prindere<\/strong>: Ata\u0219a\u021bi bine clema de prindere a gulerului LLA pe guler.<\/li><li><strong>Setare zero<\/strong>: Seta\u021bi senzorul de cuplu la zero f\u0103r\u0103 a aplica niciun cuplu ini\u021bial.<\/li><li><strong>Viteza de rota\u021bie<\/strong>: Regla\u021bi rota\u021bia la 20 de rota\u021bii pe minut (sau dup\u0103 cum s-a convenit cu clientul).<\/li><li><strong>\u00cenceperea testului<\/strong>: Roti\u021bi placa turnant\u0103 cu 90 \u00b0 \u00een sensul acelor de ceasornic sau \u00een sens invers acelor de ceasornic sau roti\u021bi \u00eenchiderea \u00een sine.<\/li><li><strong>\u00cenregistrarea cuplului de v\u00e2rf<\/strong>: \u00cenregistra\u021bi cuplul maxim \u00een momentul \u00een care gulerul \u00eencepe s\u0103 se roteasc\u0103.<\/li><\/ol><p>Cuplul maxim \u00eenregistrat reprezint\u0103 rezisten\u021ba colierului la for\u021ba de rota\u021bie \u0219i trebuie s\u0103 respecte specifica\u021biile definite \u00een standardele produsului.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bec81ba e-con-full e-flex e-con e-child\" data-id=\"bec81ba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf895da elementor-widget elementor-widget-text-editor\" data-id=\"bf895da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Exprimarea \u0219i raportarea rezultatelor testelor<\/h3><p>Dup\u0103 finalizarea testului, este esen\u021bial s\u0103 v\u0103 documenta\u021bi:<\/p><ul><li>Valoarea cuplului maxim m\u0103surat (\u00een Ncm).<\/li><li>Viteza de rota\u021bie utilizat\u0103.<\/li><li>Num\u0103rul de e\u0219antioane testate \u0219i aprobate.<\/li><li>Orice abateri sau anomalii observate.<\/li><\/ul><p>Trasabilitatea este esen\u021bial\u0103. Chiar dac\u0103 unii parametri de configurare nu sunt tip\u0103ri\u021bi automat, ace\u0219tia trebuie \u00eenregistra\u021bi manual pentru a men\u021bine o trasabilitate complet\u0103.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-054461f elementor-widget elementor-widget-image\" data-id=\"054461f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"330\" height=\"320\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp\" class=\"attachment-large size-large wp-image-280\" alt=\"Rezisten\u021ba la torsiune a colierului adaptor Luer Lock - ISO 11040-4 Anexa G4\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp 330w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4-300x291.webp 300w\" sizes=\"(max-width: 330px) 100vw, 330px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3b32991 e-grid e-con-full e-con e-parent\" data-id=\"3b32991\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11c9fc9 elementor-widget elementor-widget-image\" data-id=\"11c9fc9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-50e8f10 e-con-full e-flex e-con e-child\" data-id=\"50e8f10\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0b4cdfa elementor-widget elementor-widget-heading\" data-id=\"0b4cdfa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">De ce s\u0103 alege\u021bi <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7339cce elementor-widget elementor-widget-text-editor\" data-id=\"7339cce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"203\" data-end=\"463\">La <strong>Syringetest.com<\/strong>, aducem \u00eempreun\u0103 expertiz\u0103, inova\u021bie, de la inginerie precis\u0103 la servicii personalizate pentru a ne sprijini clien\u021bii din \u00eentreaga lume.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ce9df1f elementor-widget elementor-widget-text-editor\" data-id=\"ce9df1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La Syringetest.com, \u00een\u021belegem c\u0103 fiabilitatea <strong>guler adaptor luer lock rezisten\u021b\u0103 la cuplu<\/strong> este esen\u021bial\u0103 pentru succesul produselor dvs. de sering\u0103. Oferim testere de cuplu de \u00eenalt\u0103 precizie care \u00eendeplinesc sau dep\u0103\u0219esc cerin\u021bele <strong>ISO 11040-4<\/strong> \u0219i <strong>ISO 11040-4 Anexa G4<\/strong>. Instrumentele noastre dispun de:<\/p><ul><li><strong>Rate ridicate de e\u0219antionare<\/strong> pentru o mai bun\u0103 precizie a v\u00e2rfurilor.<\/li><li><strong>Software u\u0219or de utilizat<\/strong> cu documenta\u021bie de testare complet\u0103.<\/li><li><strong>Corpuri personalizabile<\/strong> pentru a se potrivi diferitelor modele de seringi.<\/li><\/ul><p>\u00cen plus, ne sprijinim clien\u021bii cu expertiz\u0103 tehnic\u0103 \u0219i personalizare a automatiz\u0103rii, asigur\u00e2ndu-ne c\u0103 fluxurile dvs. de testare sunt eficiente, precise \u0219i conforme.<\/p><p>Testare <strong>guler adaptor luer lock rezisten\u021b\u0103 la cuplu<\/strong> \u00een conformitate cu <strong>ISO 11040-4 Anexa G4<\/strong> nu este doar o formalitate de reglementare - este o etap\u0103 critic\u0103 de control al calit\u0103\u021bii care asigur\u0103 siguran\u021ba, fiabilitatea \u0219i satisfac\u021bia utilizatorului produsului. Cu echipamentul \u0219i metodologia de testare potrivite, pute\u021bi aduce cu \u00eencredere pe pia\u021b\u0103 produse seringi sigure \u0219i conforme.<\/p><p>Dac\u0103 ave\u021bi nevoie de asisten\u021b\u0103 pentru configurarea testelor de rezisten\u021b\u0103 la cuplu sau pentru selectarea instrumentelor de testare potrivite, <strong>Syringetest.com<\/strong> este aici pentru a v\u0103 ajuta. Contacta\u021bi-ne ast\u0103zi pentru a afla mai multe despre solu\u021biile noastre adaptate nevoilor dumneavoastr\u0103 de testare a seringilor.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb0e531 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"eb0e531\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/ro\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contacta\u021bi-ne<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Adaptor Collar Torque Resistance Understanding luer lock adaptor collar torque resistance is critical for ensuring the quality and reliability of prefilled syringe assemblies. This test verifies the ability of the Luer Lock Adaptor (LLA) collar to resist rotational forces when a Luer fitting, such as a needle hub, is attached. Ensuring that your [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-277","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/pages\/277","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/comments?post=277"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/pages\/277\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/media?parent=277"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}