{"id":247,"date":"2025-05-06T02:59:16","date_gmt":"2025-05-06T02:59:16","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=247"},"modified":"2026-05-14T08:15:29","modified_gmt":"2026-05-14T08:15:29","slug":"needle-tubing-stiffness-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/ro\/needle-tubing-stiffness-test","title":{"rendered":"Test de rigiditate a tubului cu ac"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"247\" class=\"elementor elementor-247\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1e601d7 e-flex e-con-boxed e-con e-parent\" data-id=\"1e601d7\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0e5a4e8 elementor-widget elementor-widget-heading\" data-id=\"0e5a4e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Test de rigiditate a tubului cu ac<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-307f5d3 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"307f5d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong>test de rigiditate a tubului acului<\/strong> joac\u0103 un rol esen\u021bial \u00een asigurarea performan\u021bei \u0219i siguran\u021bei dispozitivelor medicale, \u00een special a acelor hipodermice. Acest test determin\u0103 rezisten\u021ba tuburilor din o\u021bel inoxidabil la \u00eendoire atunci c\u00e2nd este aplicat\u0103 o for\u021b\u0103 standardizat\u0103. Pentru profesioni\u0219tii din industria dispozitivelor medicale - \u00een special cei implica\u021bi \u00een asigurarea calit\u0103\u021bii seringilor - \u00een\u021belegerea acestui test este esen\u021bial\u0103 pentru respectarea standardelor de reglementare \u0219i asigurarea siguran\u021bei pacien\u021bilor.<\/p><p>Syringetest.com ofer\u0103 solu\u021bii de \u00eenalt\u0103 precizie pentru efectuarea testelor de rigiditate a tuburilor acului, asigur\u00e2nd conformitatea produselor dvs. cu standardele globale, cum ar fi <strong>ISO 9626<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5684a6e e-flex e-con-boxed e-con e-parent\" data-id=\"5684a6e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-02d54a2 elementor-widget elementor-widget-heading\" data-id=\"02d54a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 9626 \u0219i ISO 9626 anexa B<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b9bcb4 e-con-full e-flex e-con e-child\" data-id=\"1b9bcb4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c55fa1a elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"c55fa1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.syringetest.com\/ro\/standards\/iso-9626\/\"><strong>ISO 9626<\/strong><\/a>, intitulat <em>Tuburi ac din o\u021bel inoxidabil pentru fabricarea dispozitivelor medicale - Cerin\u021be \u0219i metode de testare<\/em>stabile\u0219te criteriile fizice \u0219i mecanice pentru tuburile din o\u021bel inoxidabil utilizate \u00een dispozitivele medicale. Printre componentele sale cheie, <strong>ISO 9626 Anexa B<\/strong> ofer\u0103 o metod\u0103 detaliat\u0103 de efectuare a <strong>test de rigiditate a tubului acului<\/strong>, oferind cerin\u021be procedurale stricte \u0219i specifica\u021bii privind echipamentele.<\/p><p>Anexa B prezint\u0103 modul de evaluare a rigidit\u0103\u021bii prin aplicarea unui <strong>for\u021b\u0103 specificat\u0103<\/strong> la centrul tubului sus\u021binut la ambele capete \u0219i m\u0103surarea <strong>deformarea rezultat\u0103<\/strong>. Acest proces ajut\u0103 la evaluarea dac\u0103 tubulatura \u00eendepline\u0219te rezisten\u021ba mecanic\u0103 necesar\u0103 pentru a rezista utiliz\u0103rii reale f\u0103r\u0103 a se \u00eendoi sau a ceda.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25a7788 elementor-widget elementor-widget-image\" data-id=\"25a7788\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"590\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard.webp\" class=\"attachment-large size-large wp-image-99\" alt=\"standard de testare a for\u021bei de desprindere \u0219i de alunecare\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard-300x295.webp 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd39b91 e-con-full e-flex e-con e-child\" data-id=\"fd39b91\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-315872e elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"315872e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Principiul \u0219i semnifica\u021bia testului<\/h3><p>Principiul de baz\u0103 al <strong>test de rigiditate a tubului acului<\/strong> este simpl\u0103: o for\u021b\u0103 fix\u0103 descendent\u0103 este aplicat\u0103 \u00een centrul tubului acului, care este sus\u021binut orizontal la ambele capete. For\u021ba <strong>cantitatea de deformare<\/strong> la punctul de aplicare a for\u021bei indic\u0103 rigiditatea tubului.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0b91159 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"0b91159\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>De ce este important acest lucru?<\/h3><ul><li><strong>Siguran\u021ba produsului:<\/strong> Evita\u021bi \u00eendoirea sau ruperea \u00een timpul injec\u021biei.<\/li><li><strong>Consisten\u021ba fabrica\u021biei:<\/strong> Asigura\u021bi-v\u0103 c\u0103 fiecare lot \u00eendepline\u0219te acelea\u0219i standarde mecanice.<\/li><li><strong>Conformitatea cu reglement\u0103rile:<\/strong> Face\u021bi cuno\u0219tin\u021b\u0103 <strong>ISO 9626<\/strong> certificare pentru intrarea pe pia\u021ba global\u0103.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2176b2b e-flex e-con-boxed e-con e-parent\" data-id=\"2176b2b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0601f88 elementor-widget elementor-widget-heading\" data-id=\"0601f88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Echipament necesar pentru testul de rigiditate a tuburilor cu ace<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91dcc43 elementor-widget elementor-widget-text-editor\" data-id=\"91dcc43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pentru a efectua testul \u00een conformitate cu <strong>ISO 9626 Anexa B<\/strong>, este necesar urm\u0103torul aparat:<\/p><h3>Aparat de testare a rigidit\u0103\u021bii<\/h3><p class=\"\" data-start=\"2125\" data-end=\"2247\">Capabil s\u0103 aplice p\u00e2n\u0103 la <strong>60 N<\/strong> de for\u021b\u0103 cu o precizie de <strong>\u00b10.1 N<\/strong>, cu o <strong>piston \u00een form\u0103 de pan\u0103 tocit\u0103<\/strong>. Pies\u0103 trebuie s\u0103 fie format\u0103 din dou\u0103 suprafe\u021be plane \u00eenclinate la <strong>60\u00b0<\/strong>, intersectat\u0103 de o suprafa\u021b\u0103 cilindric\u0103 cu o <strong>Raza de 1 mm<\/strong>.<\/p><h3 data-start=\"2125\" data-end=\"2247\">Dispozitiv de m\u0103surare a devia\u021biei<\/h3><p class=\"\" data-start=\"2755\" data-end=\"3082\">Exact p\u00e2n\u0103 la <strong>0,01 mm<\/strong>, utilizat pentru a \u00eenregistra c\u00e2t de mult se \u00eendoaie tubulatura sub for\u021ba aplicat\u0103.<\/p><p>Syringetest.com ofer\u0103 instrumente de testare personalizabile care \u00eendeplinesc pe deplin aceste cerin\u021be tehnice, ajut\u00e2nd laboratoarele \u0219i produc\u0103torii s\u0103 implementeze procese de testare standardizate \u0219i repetabile.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-512b05c e-flex e-con-boxed e-con e-parent\" data-id=\"512b05c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-820f2d6 elementor-widget elementor-widget-heading\" data-id=\"820f2d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procedura de testare a rigidit\u0103\u021bii tuburilor cu ace<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9839f71 elementor-widget elementor-widget-text-editor\" data-id=\"9839f71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>1. Plasarea e\u0219antionului<\/h3><p>A\u0219eza\u021bi tubulatura pe aparatul de testare. Asigura\u021bi-v\u0103 c\u0103:<\/p><ul><li>The <strong>span<\/strong> corespunde valorilor enumerate \u00een tabelul 2 din ISO 9626 pentru dimensiunea tubului dat.<\/li><li>The <strong>piston<\/strong> este centrat\u0103.<\/li><li>Tubulatura este orientat\u0103 <strong>perpendicular<\/strong> at\u00e2t la piston, c\u00e2t \u0219i la punctele de sprijin.<\/li><\/ul><h3>2. Aplicarea for\u021bei<\/h3><p>Aplica\u021bi for\u021ba descendent\u0103 specificat\u0103 pentru dimensiunea tubului, la o rat\u0103 controlat\u0103 de <strong>1 mm\/min p\u00e2n\u0103 la 10 mm\/min<\/strong>.<\/p><h3>3. M\u0103surarea devia\u021biei<\/h3><p>M\u0103sura\u021bi \u0219i \u00eenregistra\u021bi <strong>deviere<\/strong> a tubului la centru cu o precizie de <strong>\u00b10,01 mm<\/strong>.<\/p><h3>4. Raportarea rezultatelor<\/h3><p>Un raport de testare complet trebuie s\u0103 includ\u0103:<\/p><ul><li>Dimensiunea \u0219i identificarea tubului<\/li><li>Tipul tubului (RW, TW, ETW, UTW)<\/li><li>Deflec\u021bie m\u0103surat\u0103<\/li><li>Data test\u0103rii<\/li><li>Aliaj de o\u021bel inoxidabil utilizat<\/li><\/ul><p>Testerele automate de rigiditate Syringetest.com simplific\u0103 acest proces prin integrarea <strong>senzori de precizie<\/strong> \u0219i <strong>interfe\u021be u\u0219or de utilizat<\/strong> pentru a asigura repetabilitatea \u0219i trasabilitatea rezultatelor testelor.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b7a8cd e-grid e-con-full e-con e-parent\" data-id=\"7b7a8cd\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ce47441 elementor-widget elementor-widget-image\" data-id=\"ce47441\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-413684e e-con-full e-flex e-con e-child\" data-id=\"413684e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5ae9222 elementor-widget elementor-widget-heading\" data-id=\"5ae9222\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">De ce s\u0103 alege\u021bi <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ee84ad elementor-widget elementor-widget-text-editor\" data-id=\"8ee84ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ca furnizor de \u00eencredere de solu\u021bii de testare a materialelor, <strong>Syringetest.com<\/strong> ofer\u0103 instrumente care \u00eendeplinesc \u0219i dep\u0103\u0219esc standardele ISO. Testerele noastre de rigiditate sunt proiectate pentru:<\/p><ul><li><strong>Precizie \u0219i fiabilitate ridicate<\/strong><\/li><li><strong>Personalizarea utilizatorului<\/strong> pentru dimensiuni speciale ale tuburilor sau tipuri de aliaje<\/li><li><strong>Op\u021biuni de automatizare<\/strong> pentru a spori eficien\u021ba test\u0103rii<\/li><li><strong>\u00cenregistrarea datelor \u0219i trasabilitatea<\/strong> pentru preg\u0103tirea pentru audit<\/li><\/ul><p>Deservim industrii variind de la <strong>dispozitive medicale \u0219i produse farmaceutice pentru laboratoarele de control al calit\u0103\u021bii<\/strong>. Cu un accent puternic pe inovare, sprijinim, de asemenea <strong>moderniz\u0103ri de automatizare<\/strong> \u0219i <strong>dezvoltarea de teste personalizate<\/strong>.<\/p><p>The <strong>test de rigiditate a tubului acului<\/strong>, atunci c\u00e2nd sunt efectuate \u00een mod corespunz\u0103tor \u00een conformitate cu <strong>ISO 9626 Anexa B<\/strong>asigur\u0103 c\u0103 tubulatura medical\u0103 \u00ee\u0219i men\u021bine integritatea mecanic\u0103 \u00een timpul utiliz\u0103rii. Nu este vorba doar despre conformitate - este vorba despre <strong>protejarea pacien\u021bilor \u0219i men\u021binerea \u00eencrederii<\/strong> \u00een produsele medicale.<\/p><p>Cu instrumente de testare de nivel profesional de la <strong>Syringetest.com<\/strong>, produc\u0103torii pot asigura cu \u00eencredere calitatea produselor, pot respecta standardele interna\u021bionale \u0219i pot simplifica procesele de control al calit\u0103\u021bii.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-383dde0 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"383dde0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/ro\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contacta\u021bi-ne<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Needle Tubing Stiffness Test The needle tubing stiffness test plays a critical role in ensuring the performance and safety of medical devices, particularly hypodermic needles. This test determines the resistance of stainless steel tubing to bending when a standardized force is applied. For professionals in the medical device industry\u2014especially those involved in quality assurance of [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-247","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/pages\/247","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/comments?post=247"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/pages\/247\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/media?parent=247"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}