{"id":205,"date":"2025-04-30T07:52:58","date_gmt":"2025-04-30T07:52:58","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=205"},"modified":"2026-05-09T07:32:11","modified_gmt":"2026-05-09T07:32:11","slug":"needle-bonding-strength-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/ro\/needle-bonding-strength-test","title":{"rendered":"Testarea rezisten\u021bei lipirii acului"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"205\" class=\"elementor elementor-205\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11915ec e-flex e-con-boxed e-con e-parent\" data-id=\"11915ec\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1b7a35f elementor-widget elementor-widget-heading\" data-id=\"1b7a35f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Testarea rezisten\u021bei lipirii acului<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-295ce65 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"295ce65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong>puterea de lipire a acului<\/strong> este o m\u0103sur\u0103 esen\u021bial\u0103 de asigurare a calit\u0103\u021bii \u00een industria produc\u0103toare de seringi. Acest test determin\u0103 dac\u0103 leg\u0103tura dintre ac \u0219i sering\u0103 - sau dintre ac \u0219i butuc - poate rezista for\u021belor de trac\u021biune preconizate \u00een timpul utiliz\u0103rii. O leg\u0103tur\u0103 slab\u0103 ar putea duce la riscuri grave pentru siguran\u021b\u0103, cum ar fi scurgerea, deta\u0219area acului sau r\u0103nirea pacientului.<\/p><p>Av\u00e2nd \u00een vedere aplica\u021biile critice ale seringilor \u00een domeniile medical, farmaceutic \u0219i biotehnologic, este necesar\u0103 o <strong>testarea seringii<\/strong> \u00een conformitate cu standarde recunoscute la nivel interna\u021bional, cum ar fi <strong>ISO 11040-4 Anexa G1<\/strong>, <strong>ISO 7864<\/strong>, \u0219i <strong>ISO 11608-2<\/strong> este imperativ.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0078138 e-flex e-con-boxed e-con e-parent\" data-id=\"0078138\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99fd12a elementor-widget elementor-widget-heading\" data-id=\"99fd12a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Importan\u021ba test\u0103rii rezisten\u021bei lipirii cu ac<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-489ffe8 elementor-widget elementor-widget-text-editor\" data-id=\"489ffe8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Rezisten\u021ba aderen\u021bei acului este un parametru critic de performan\u021b\u0103 \u00een sistemele de seringi \u0219i ace, \u00een special \u00een seringile preumplute \u0219i dispozitivele de injectare pe baz\u0103 de ace. Aceasta determin\u0103 dac\u0103 un ac r\u0103m\u00e2ne bine ata\u0219at la sering\u0103 sau la hub \u00een timpul utiliz\u0103rii, asigur\u00e2nd administrarea sigur\u0103 \u0219i eficient\u0103 a medicamentului. Lipsa rezisten\u021bei la lipire poate duce la desprinderea acului, r\u0103nirea pacientului sau dozarea incomplet\u0103, ceea ce prezint\u0103 riscuri semnificative pentru siguran\u021b\u0103.<\/p><p>\u00cen centrul asigur\u0103rii calit\u0103\u021bii seringilor, <strong>test de rezisten\u021b\u0103 la lipirea acului<\/strong> ofer\u0103 o validare esen\u021bial\u0103 pentru fiabilitatea produsului, siguran\u021ba pacientului \u0219i conformitatea cu reglement\u0103rile. Aceste teste sunt aliniate la standarde interna\u021bionale precum <strong>ISO 11040-4 Anexa G1<\/strong>, <strong>ISO 7864<\/strong>, \u0219i <strong>ISO 11608-2<\/strong>, care definesc proceduri specifice \u0219i praguri de performan\u021b\u0103 pentru rezisten\u021ba de lipire \u00een diferite tipuri de seringi asamblate.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0ceb936 e-flex e-con-boxed e-con e-parent\" data-id=\"0ceb936\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7056e55 elementor-widget elementor-widget-heading\" data-id=\"7056e55\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standarde conexe pentru testarea rezisten\u021bei de lipire a acelor<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54d2ea3 elementor-widget elementor-widget-text-editor\" data-id=\"54d2ea3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Orient\u0103rile ISO ofer\u0103 un cadru solid pentru evaluarea <strong>puterea de lipire a acului<\/strong> pe diferite tipuri de seringi \u0219i ace.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cafe546 e-con-full e-flex e-con e-child\" data-id=\"cafe546\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e0674d5 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"e0674d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>ISO 11040-4 Anexa G1<\/h3><p>Se concentreaz\u0103 pe seringile preumplute cu ace \u00een\u021bepenite. Acesta detaliaz\u0103 configurarea echipamentului \u0219i procedura de m\u0103surare <strong>for\u021ba de extragere a acului<\/strong>, asigur\u00e2nd integritatea procesului de fixare a acului.<\/p><h3>ISO 7864 Anexa E<\/h3><p>Descrie metodele de testare pentru <strong>ace hipodermice<\/strong>, examin\u00e2nd \u00een special leg\u0103tura dintre butucul acului \u0219i tubul acului.<\/p><h3>ISO 11608-2 Anexa B<\/h3><p>Relevant\u0103 pentru seringile de unic\u0103 folosin\u021b\u0103 pentru insulin\u0103, aceast\u0103 anex\u0103 define\u0219te cerin\u021bele privind for\u021ba de alunecare pentru administrarea precis\u0103 \u0219i constant\u0103 a insulinei.\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b91224d elementor-widget elementor-widget-image\" data-id=\"b91224d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"515\" height=\"350\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" class=\"attachment-large size-large wp-image-207\" alt=\"Test de rezisten\u021b\u0103 a lipirii acului - Testarea acului seringii\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp 515w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing-300x204.webp 300w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6567345 elementor-widget elementor-widget-text-editor\" data-id=\"6567345\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Fiecare standard specific\u0103 parametrii critici, cum ar fi:<\/p><ul><li>Utilizarea unui <strong>ma\u0219in\u0103 universal\u0103 de testare la trac\u021biune \u0219i compresie<\/strong>.<\/li><li>O vitez\u0103 de testare standard de <strong>50 mm\/min<\/strong>.<\/li><li>Rata de e\u0219antionare adecvat\u0103 (de obicei <strong>\u2265100 Hz<\/strong>, \u0219i <strong>500 Hz<\/strong> pentru precizia for\u021bei de v\u00e2rf).<\/li><li>Mecanisme adecvate de prindere a acului pentru a evita alunecarea \u0219i interferen\u021ba m\u0103sur\u0103torilor.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fc94bb4 e-flex e-con-boxed e-con e-parent\" data-id=\"fc94bb4\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5df17a7 elementor-widget elementor-widget-heading\" data-id=\"5df17a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procedura de testare a rezisten\u021bei lipirii cu ac<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc1819f elementor-widget elementor-widget-text-editor\" data-id=\"fc1819f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 data-start=\"2125\" data-end=\"2247\">1. Preg\u0103tirea probei<\/h3><p class=\"\" data-start=\"2125\" data-end=\"2247\">Utiliza\u021bi seringi sau ace sterilizate preg\u0103tite \u00een acela\u0219i mod ca \u0219i loturile de produc\u021bie reale.<\/p><h3>2. Configurarea echipamentului:<\/h3><ul><li>Fixa\u021bi seringa sau acul folosind un <strong>titular<\/strong> care sus\u021bine alinierea axial\u0103 corespunz\u0103toare.<\/li><li>Ata\u0219a\u021bi <strong>dispozitivul de prindere a acului<\/strong>-concepute pentru a prinde f\u0103r\u0103 deformare sau alunecare.<\/li><li>Configura\u021bi <strong>tester de trac\u021biune<\/strong> cu un <strong>celul\u0103 de sarcin\u0103<\/strong> (p\u00e2n\u0103 la 500 N \u00een func\u021bie de aplica\u021bie).<\/li><\/ul><h3>3. Executarea testelor:<\/h3><ul><li>Reseta\u021bi celula de sarcin\u0103 f\u0103r\u0103 nicio pre\u00eenc\u0103rcare.<\/li><li>Efectua\u021bi testul la <strong>50 mm\/min<\/strong>, colectarea datelor cu o rat\u0103 de e\u0219antionare suficient\u0103.<\/li><li>M\u0103sura\u021bi \u0219i \u00eenregistra\u021bi <strong>for\u021b\u0103 maxim\u0103 de trac\u021biune<\/strong> aplicat \u00eenainte de deta\u0219are sau defec\u021biune.<\/li><\/ul><h3>4. Interpretarea datelor:<\/h3><ul><li>Analiza\u021bi <strong>curba for\u021b\u0103 vs. deplasare<\/strong> pentru a g\u0103si puterea maxim\u0103 de lipire.<\/li><li>Verificarea rezultatelor \u00een raport cu criteriile de acceptare predefinite din protocoalele ISO sau interne.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1103d96 elementor-widget elementor-widget-text-editor\" data-id=\"1103d96\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Documentarea adecvat\u0103 a rezultatelor testelor, inclusiv a oric\u0103ror abateri, este esen\u021bial\u0103 pentru trasabilitate \u0219i audituri de conformitate.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-99b8376 e-grid e-con-full e-con e-parent\" data-id=\"99b8376\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-42da099 elementor-widget elementor-widget-image\" data-id=\"42da099\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-80b6864 e-con-full e-flex e-con e-child\" data-id=\"80b6864\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7980158 elementor-widget elementor-widget-heading\" data-id=\"7980158\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">De ce s\u0103 alege\u021bi <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a37b10d elementor-widget elementor-widget-text-editor\" data-id=\"a37b10d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La <strong>Instrumente celulare<\/strong>, oferim sisteme specializate de testare la trac\u021biune concepute exact pentru aplica\u021biile de lipire a acelor. Instrumentele noastre sunt conforme cu:<\/p><ul><li>ISO 11040-4 Anexa G1<\/li><li>ISO 7864<\/li><li>ISO 11608-2<\/li><\/ul><p>Caracteristicile includ:<\/p><ul><li>De \u00eenalt\u0103 precizie <strong>celule de sarcin\u0103<\/strong> pentru m\u0103surarea precis\u0103 a for\u021bei.<\/li><li>Configurabil <strong>dispozitive de prindere a acelor<\/strong> \u0219i <strong>suporturi pentru seringi<\/strong>.<\/li><li>Software intuitiv pentru <strong>analiza for\u021b\u0103-deplasare \u00een timp real<\/strong> \u0219i generarea automat\u0103 de rapoarte.<\/li><\/ul><p>De asemenea, oferim <strong>corpuri personalizate<\/strong> \u0219i <strong>solu\u021bii de automatizare<\/strong> pentru nevoile de testare \u00een cercetare \u0219i dezvoltare \u0219i produc\u021bie.<\/p><p>Fie c\u0103 sunte\u021bi un <strong>tehnician control calitate<\/strong>, <strong>specialist \u00een reglementare<\/strong>, sau <strong>produc\u0103tor de seringi<\/strong>, Cell Instruments este partenerul dvs. pentru realizarea de teste fiabile, eficiente \u0219i conforme cu ISO pentru seringi.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-43c643d elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"43c643d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/ro\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contacta\u021bi-ne<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Needle Bonding Strength Testing The needle bonding strength test is an essential quality assurance measure in the syringe manufacturing industry. This test determines whether the connection between the needle and syringe\u2014or the needle and hub\u2014can withstand expected tensile forces during use. Weak bonding could result in serious safety risks such as leakage, needle detachment, or [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-205","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/pages\/205","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/comments?post=205"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/pages\/205\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/media?parent=205"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}