{"id":154,"date":"2025-04-30T01:31:34","date_gmt":"2025-04-30T01:31:34","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=154"},"modified":"2026-05-09T06:36:31","modified_gmt":"2026-05-09T06:36:31","slug":"finger-flange-breakage-force-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/ro\/finger-flange-breakage-force-test","title":{"rendered":"Testul for\u021bei de rupere a flan\u0219ei degetului"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"154\" class=\"elementor elementor-154\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-247db7c e-flex e-con-boxed e-con e-parent\" data-id=\"247db7c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab06118 elementor-widget elementor-widget-heading\" data-id=\"ab06118\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Testarea for\u021bei de rupere a flan\u0219ei degetelor<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62cf733 elementor-widget elementor-widget-text-editor\" data-id=\"62cf733\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00cen industria ambalajelor farmaceutice \u0219i medicale, <strong>for\u021ba de rupere a flan\u0219ei degetului<\/strong> este un indicator de performan\u021b\u0103 esen\u021bial pentru asigurarea fiabilit\u0103\u021bii structurale a tuburilor de sering\u0103. Acest parametru, definit \u0219i standardizat \u00een <strong><em><a href=\"https:\/\/www.syringetest.com\/ro\/standards\/iso-11040-4\/\">ISO 11040-4<\/a> Anexa C1<\/em><\/strong>ajut\u0103 produc\u0103torii \u0219i profesioni\u0219tii din domeniul asigur\u0103rii calit\u0103\u021bii s\u0103 evalueze dac\u0103 flan\u0219a seringii poate rezista la solicit\u0103ri mecanice \u00een timpul manipul\u0103rii \u0219i injec\u021biei.<\/p><p>\u00cen\u021belegerea acestei m\u0103suri \u0219i a metodei sale standard de testare este vital\u0103 pentru profesioni\u0219tii implica\u021bi \u00een <strong>testarea seringii<\/strong>, \u00een special pentru seringile sterile subansamblate destinate solu\u021biilor injectabile.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f136d2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f136d2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b673494 elementor-widget elementor-widget-heading\" data-id=\"b673494\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Importan\u021ba for\u021bei de rupere a flan\u0219ei degetelor \u00een integritatea seringii<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa819a0 elementor-widget elementor-widget-text-editor\" data-id=\"aa819a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong>for\u021ba de rupere a flan\u0219ei degetului<\/strong> se refer\u0103 la for\u021ba mecanic\u0103 maxim\u0103 la care flan\u0219a unei seringi poate rezista \u00eenainte de a ceda. Aceast\u0103 valoare indic\u0103 robuste\u021bea seringii, \u00een special atunci c\u00e2nd utilizatorii aplic\u0103 presiune \u00een timpul injec\u021biei sau c\u00e2nd sistemele automate de umplere prind seringa.<\/p><p>O for\u021b\u0103 de rupere insuficient\u0103 poate duce la fisuri ale flan\u0219ei sau la defectarea complet\u0103, reprezent\u00e2nd un pericol pentru siguran\u021b\u0103. Prin urmare, men\u021binerea unei calit\u0103\u021bi constante \u00eentre loturi nu este negociabil\u0103 \u00een fabricarea dispozitivelor medicale.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-37feff9 e-flex e-con-boxed e-con e-parent\" data-id=\"37feff9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3146496 elementor-widget elementor-widget-heading\" data-id=\"3146496\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testul for\u021bei de rupere a flan\u0219ei degetelor - ISO 11040-4 Anexa C1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08fc359 elementor-widget elementor-widget-text-editor\" data-id=\"08fc359\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong><a href=\"https:\/\/www.syringetest.com\/ro\/standards\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">ISO 11040-4<\/a> Anexa C1<\/strong> prezint\u0103 metoda de testare pentru evaluarea rezisten\u021bei la ruperea flan\u0219ei. Procedura asigur\u0103 rezultate precise \u0219i repetabile, ceea ce o face standardul de aur \u00een testarea performan\u021bei seringilor.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd10895 e-grid e-con-full e-con e-child\" data-id=\"fd10895\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d98b842 elementor-widget elementor-widget-text-editor\" data-id=\"d98b842\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Obiectivul testului<\/h3><p>Pentru a determina rezisten\u021ba la rupere a flan\u0219ei prin aplicarea unei for\u021be descendente pe corpul seringii cu ajutorul unui echipament specializat. Acest test evalueaz\u0103 at\u00e2t <strong>rezisten\u021ba butoiului de sticl\u0103<\/strong> \u0219i compatibilitatea sa cu restul designului seringii.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db58dbc elementor-widget elementor-widget-text-editor\" data-id=\"db58dbc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Echipament necesar<\/h3><ul><li><strong>Ma\u0219in\u0103 universal\u0103 de testare la trac\u021biune \u0219i compresie<\/strong>: Trebuie s\u0103 includ\u0103 o celul\u0103 de sarcin\u0103 adecvat\u0103 \u0219i o vitez\u0103 de testare configurabil\u0103 de <strong>100 mm\/min<\/strong>.<\/li><li><strong>Suport sering\u0103<\/strong>: Fabricat de obicei din PEEK, adaptat la dimensiunile seringii.<\/li><li><strong>Pin de \u00eenc\u0103rcare<\/strong>: Fabricat din poliacetale sau o\u021bel inoxidabil, conceput pentru a aplica uniform for\u021ba.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a8c15d0 elementor-widget elementor-widget-image\" data-id=\"a8c15d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"202\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-1024x258.webp\" class=\"attachment-large size-large wp-image-163\" alt=\"Testul for\u021bei de rupere a flan\u0219ei degetului seringii - ISO 11040-4 Anexa C1\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-1024x258.webp 1024w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-300x76.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-768x194.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1.webp 1190w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a78210 e-flex e-con-boxed e-con e-parent\" data-id=\"3a78210\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e89a55d elementor-widget elementor-widget-heading\" data-id=\"e89a55d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Configurarea \u0219i executarea test\u0103rii cu sering\u0103<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e8f3f2 elementor-widget elementor-widget-text-editor\" data-id=\"2e8f3f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pentru a efectua testul astfel cum se specific\u0103 \u00een <strong>Testarea ISO 11040-4<\/strong>, urma\u021bi ace\u0219ti pa\u0219i:<\/p><h3>1. Preg\u0103tirea probei<\/h3><p>Evita\u021bi \u0219ocarea sau manipularea necorespunz\u0103toare a seringilor \u00eenainte de testare. Inspecta\u021bi suportul \u0219i \u0219tiftul pentru uzur\u0103.<\/p><h3>2. Configurarea echipamentului<\/h3><ul><li>A\u0219eza\u021bi seringa \u00een suportul de sub flan\u0219\u0103.<\/li><li>Alinia\u021bi \u0219tiftul de \u00eenc\u0103rcare pentru a aplica for\u021ba la ad\u00e2ncimea flan\u0219ei \u021bevii.<\/li><\/ul><h3>3. Executarea testelor<\/h3><ul><li>Rula\u021bi ma\u0219ina la <strong>100 mm\/min<\/strong>.<\/li><li>\u00cenregistra\u021bi graficul for\u021b\u0103-deplasare.<\/li><li>Utiliza\u021bi un <strong>rat\u0103 de e\u0219antionare de cel pu\u021bin 500 Hz<\/strong> pentru detectarea for\u021bei maxime.<\/li><\/ul><h3>4. Analiza rezultatelor<\/h3><p>For\u021ba maxim\u0103 observat\u0103 \u00eenainte de ruperea flan\u0219ei este \u00eenregistrat\u0103 ca <strong>for\u021ba de rupere a flan\u0219ei degetului<\/strong>. ISO 11040-4 Anexa C1 specific\u0103 faptul c\u0103 aceast\u0103 valoare, \u00eempreun\u0103 cu viteza de testare \u0219i num\u0103rul de e\u0219antioane, trebuie raportate \u00een documenta\u021bia final\u0103.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2d148ee e-grid e-con-full e-con e-parent\" data-id=\"2d148ee\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef5e9b3 elementor-widget elementor-widget-image\" data-id=\"ef5e9b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f83c119 e-con-full e-flex e-con e-child\" data-id=\"f83c119\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-af86f15 elementor-widget elementor-widget-heading\" data-id=\"af86f15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">De ce s\u0103 alege\u021bi <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-321653d elementor-widget elementor-widget-text-editor\" data-id=\"321653d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Testarea precis\u0103 a for\u021bei de rupere a flan\u0219elor necesit\u0103 instrumente de \u00eenalt\u0103 performan\u021b\u0103. La <strong>Syringetest.com<\/strong>, oferim testere avansate de trac\u021biune \u0219i compresie adaptate pentru <strong>testarea seringii<\/strong>, \u00een deplin\u0103 conformitate cu <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><em>ISO 11040-4<\/em><\/a>. Sistemele noastre sunt echipate cu celule de sarcin\u0103 de precizie, viteze reglabile \u0219i software intuitiv pentru vizualizarea \u0219i exportul datelor \u00een timp real.<\/p><p>De asemenea, oferim <strong>suporturi de seringi personalizate \u0219i integrarea automatiz\u0103rii<\/strong>, contribuind la eficientizarea test\u0103rii \u00een medii de produc\u021bie cu randament ridicat.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-262c330 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"262c330\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/ro\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contacta\u021bi-ne<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Finger Flange Breakage Force Testing In the pharmaceutical and medical packaging industry, finger flange breakage force is a critical performance indicator for ensuring the structural reliability of syringe barrels. This parameter, defined and standardized in ISO 11040-4 Annex C1, helps manufacturers and quality assurance professionals assess whether the syringe flange can withstand mechanical stress during [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-154","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/pages\/154","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/comments?post=154"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/pages\/154\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/ro\/wp-json\/wp\/v2\/media?parent=154"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}