{"id":492,"date":"2025-06-04T05:44:42","date_gmt":"2025-06-04T05:44:42","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=492"},"modified":"2026-05-19T08:11:59","modified_gmt":"2026-05-19T08:11:59","slug":"syringe-liquid-leakage-test-for-closure-system","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/pt\/syringe-liquid-leakage-test-for-closure-system","title":{"rendered":"Ensaio de fuga de l\u00edquido da seringa para o sistema de fecho"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"492\" class=\"elementor elementor-492\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-14a7ec1 e-flex e-con-boxed e-con e-parent\" data-id=\"14a7ec1\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8ba13c0 elementor-widget elementor-widget-heading\" data-id=\"8ba13c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Teste de fuga de l\u00edquido do sistema de fecho de seringa<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bbb28e6 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"bbb28e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"401\" data-end=\"1099\">Nas ind\u00fastrias farmac\u00eautica e de dispositivos m\u00e9dicos, garantir a integridade das seringas \u00e9 crucial para a seguran\u00e7a dos produtos e a sa\u00fade dos doentes. Um dos procedimentos mais essenciais \u00e9 o <strong data-start=\"602\" data-end=\"633\">ensaio de fuga de l\u00edquido na seringa<\/strong>que avalia a capacidade do \u00eambolo e do sistema de fecho de uma seringa para evitar fugas de l\u00edquido sob press\u00e3o. Este artigo fornecer\u00e1 um guia completo sobre como efetuar o teste de fugas de l\u00edquido da seringa em conformidade com <strong data-start=\"862\" data-end=\"884\"><a href=\"https:\/\/www.syringetest.com\/pt\/standards\/iso-7886-1\/\">ISO 7886-1<\/a> Anexo D<\/strong> e <strong data-start=\"889\" data-end=\"913\"><a href=\"https:\/\/www.syringetest.com\/pt\/standards\/iso-11040-4\/\">ISO 11040-4<\/a> Anexo G2<\/strong> normas. Como fabricante l\u00edder de instrumentos de teste de precis\u00e3o, <strong data-start=\"985\" data-end=\"1005\">Instrumentos celulares<\/strong> oferece solu\u00e7\u00f5es fi\u00e1veis para profissionais e pessoal de controlo de qualidade em testes de seringas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb57b12 e-flex e-con-boxed e-con e-parent\" data-id=\"cb57b12\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c5f7942 elementor-widget elementor-widget-heading\" data-id=\"c5f7942\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Compreender o teste de fuga de l\u00edquido da seringa<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24b1f4a elementor-widget elementor-widget-text-editor\" data-id=\"24b1f4a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1106\" data-end=\"1433\">O <strong data-start=\"1162\" data-end=\"1193\">ensaio de fuga de l\u00edquido na seringa<\/strong> assegura que as seringas permanecem estanques mesmo quando sujeitas a press\u00e3o. Avalia a estanquicidade da rolha do \u00eambolo e do sistema de fecho (tampas das pontas ou protec\u00e7\u00f5es das agulhas), protegendo contra a contamina\u00e7\u00e3o e imprecis\u00f5es de dosagem.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0f9719a e-flex e-con-boxed e-con e-parent\" data-id=\"0f9719a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9a70f61 elementor-widget elementor-widget-heading\" data-id=\"9a70f61\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ensaio de fuga de l\u00edquido da seringa de acordo com a norma ISO 7886-1 Anexo D<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6461ae4 elementor-widget elementor-widget-text-editor\" data-id=\"6461ae4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1440\" data-end=\"1622\"><strong data-start=\"1506\" data-end=\"1528\">ISO 7886-1 Anexo D<\/strong> descreve um m\u00e9todo preciso para avaliar o desempenho de veda\u00e7\u00e3o da rolha do \u00eambolo da seringa.<\/p><h3 data-start=\"1440\" data-end=\"1622\">Princ\u00edpio de teste<\/h3><p data-start=\"1624\" data-end=\"1847\">A seringa \u00e9 enchida com \u00e1gua destilada, selada no bocal e sujeita a for\u00e7as axiais e radiais. O objetivo \u00e9 simular tens\u00f5es que possam causar fugas de l\u00edquido atrav\u00e9s da rolha do \u00eambolo.<\/p><h3 data-start=\"1624\" data-end=\"1847\">Aparelhos e reagentes<\/h3><ul><li><strong data-start=\"1880\" data-end=\"1898\">Dispositivo de veda\u00e7\u00e3o<\/strong>: Para selar ou ocluir completamente o bocal da seringa.<\/li><li><strong data-start=\"1949\" data-end=\"1977\">Dispositivo de aplica\u00e7\u00e3o de for\u00e7a<\/strong>: Para aplicar uma for\u00e7a lateral de 0,25 N a 3 N no \u00eambolo.<\/li><li><strong data-start=\"2042\" data-end=\"2061\">Dispositivo de press\u00e3o<\/strong>: Capaz de gerar press\u00f5es de <strong data-start=\"2098\" data-end=\"2109\">200 kPa<\/strong> e <strong data-start=\"2114\" data-end=\"2125\">300 kPa<\/strong>.<\/li><li><strong data-start=\"2131\" data-end=\"2150\">\u00c1gua destilada<\/strong>: Mantido entre <strong data-start=\"2171\" data-end=\"2189\">18 \u00b0C a 28 \u00b0C<\/strong>.<\/li><\/ul><h3 data-start=\"1624\" data-end=\"1847\">Procedimento de ensaio<\/h3><ol><li data-start=\"2216\" data-end=\"2283\">Encher a seringa com \u00e1gua destilada acima da sua capacidade nominal.<\/li><li data-start=\"2287\" data-end=\"2343\">Expulsar o ar e ajustar o volume de \u00e1gua \u00e0 capacidade nominal.<\/li><li data-start=\"2347\" data-end=\"2373\">Selar o bocal da seringa.<\/li><li data-start=\"2377\" data-end=\"2454\">Aplicar uma for\u00e7a lateral ao \u00eambolo para obter a deflex\u00e3o radial m\u00e1xima.<\/li><li data-start=\"2458\" data-end=\"2522\">Gerar a press\u00e3o necess\u00e1ria e manter durante 30-35 segundos.<\/li><li data-start=\"2526\" data-end=\"2596\">Inspecionar a seringa para verificar se existe alguma fuga de l\u00edquido para al\u00e9m da tampa do \u00eambolo.<\/li><\/ol><h3 data-start=\"1624\" data-end=\"1847\">Significado<\/h3><p data-start=\"2598\" data-end=\"2733\">Este teste simula tens\u00f5es de manuseamento para verificar se o <strong data-start=\"2674\" data-end=\"2693\">\u00eambolo da seringa<\/strong> mant\u00e9m uma veda\u00e7\u00e3o segura sob press\u00e3o.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0e39f22 e-flex e-con-boxed e-con e-parent\" data-id=\"0e39f22\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9e4bce6 elementor-widget elementor-widget-heading\" data-id=\"9e4bce6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ensaio de estanquidade do fecho da seringa: ISO 11040-4 Anexo G2<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f35e53 elementor-widget elementor-widget-text-editor\" data-id=\"2f35e53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2740\" data-end=\"2956\">O <strong data-start=\"2798\" data-end=\"2848\">ISO 11040-4 Anexo G2 ensaio de estanquidade do fecho da seringa<\/strong> centra-se na avalia\u00e7\u00e3o do desempenho de <strong data-start=\"2889\" data-end=\"2916\">sistemas de fecho de seringas<\/strong>incluindo tampas de pontas e protec\u00e7\u00f5es de agulhas.<\/p><h3 data-start=\"2740\" data-end=\"2956\">Princ\u00edpio de teste<\/h3><p data-start=\"2958\" data-end=\"3123\">O objetivo \u00e9 verificar se o sistema de fecho da seringa pode suportar uma potencial sobrepress\u00e3o durante o enchimento ou o transporte, evitando fugas.<\/p><h3 data-start=\"2740\" data-end=\"2956\">Procedimento de ensaio<\/h3><ol><li data-start=\"3149\" data-end=\"3208\">Encher a seringa at\u00e9 <strong data-start=\"3169\" data-end=\"3183\">1\/3 a 2\/3<\/strong> do volume nominal.<\/li><li data-start=\"3212\" data-end=\"3268\">Introduzir a seringa no suporte de teste e fix\u00e1-la.<\/li><li data-start=\"3272\" data-end=\"3322\">Aplicar <strong data-start=\"3278\" data-end=\"3289\">110 kPa<\/strong> de press\u00e3o para <strong data-start=\"3306\" data-end=\"3319\">5 segundos<\/strong>.<\/li><li data-start=\"3326\" data-end=\"3398\">Monitorizar a seringa para detetar qualquer fuga vis\u00edvel durante e ap\u00f3s o teste.<\/li><li data-start=\"3402\" data-end=\"3544\">Libertar a press\u00e3o e avaliar o sistema: o teste \u00e9 aprovado se as tampas das pontas ou as protec\u00e7\u00f5es das agulhas permanecerem no lugar e n\u00e3o se formarem got\u00edculas no exterior.<\/li><\/ol><h3 data-start=\"2740\" data-end=\"2956\">C\u00e1lculo da for\u00e7a<\/h3><p data-start=\"3546\" data-end=\"3669\">A for\u00e7a de press\u00e3o interna (<strong data-start=\"3602\" data-end=\"3607\">F<\/strong>) pode ser calculado com:<br data-start=\"3632\" data-end=\"3635\" \/>F = p \u00d7 \u03c0\/4 \u00d7 d\u00b2 \u00d7 10-\u00b3<br data-start=\"3658\" data-end=\"3661\" \/>onde:<\/p><ul><li data-start=\"3672\" data-end=\"3685\">p = 110 kPa<\/li><li data-start=\"3688\" data-end=\"3743\">d = di\u00e2metro nominal interior do corpo da seringa (mm)<\/li><\/ul><p data-start=\"3745\" data-end=\"3840\">Isto assegura uma aplica\u00e7\u00e3o exacta e consistente da press\u00e3o na seringa durante o teste.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f6abf6 e-flex e-con-boxed e-con e-parent\" data-id=\"9f6abf6\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cabb0a8 elementor-widget elementor-widget-heading\" data-id=\"cabb0a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Benef\u00edcios da utiliza\u00e7\u00e3o das solu\u00e7\u00f5es de teste da Cell Instruments<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e08dd76 elementor-widget elementor-widget-text-editor\" data-id=\"e08dd76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3847\" data-end=\"4059\"><strong data-start=\"3907\" data-end=\"3927\">Instrumentos celulares<\/strong> oferece um servi\u00e7o avan\u00e7ado e personaliz\u00e1vel <strong data-start=\"3961\" data-end=\"3992\">ensaio de fuga de l\u00edquido na seringa<\/strong> equipamento concebido para cumprir as normas ISO. As nossas solu\u00e7\u00f5es de ensaio:<\/p><ul><li data-start=\"4062\" data-end=\"4106\">Fornecer resultados exactos e reproduz\u00edveis.<\/li><li data-start=\"4109\" data-end=\"4155\">Adapta-se a v\u00e1rios tamanhos e tipos de seringas.<\/li><li data-start=\"4158\" data-end=\"4221\">Integra\u00e7\u00e3o perfeita com os fluxos de trabalho de controlo de qualidade existentes.<\/li><\/ul><p data-start=\"4223\" data-end=\"4349\"><strong data-start=\"4223\" data-end=\"4251\">Solu\u00e7\u00f5es de teste personalizadas<\/strong> e <strong data-start=\"4256\" data-end=\"4294\">servi\u00e7os de transforma\u00e7\u00e3o da automa\u00e7\u00e3o<\/strong> assegurar a adaptabilidade a requisitos de ensaio espec\u00edficos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-95bd826 e-flex e-con-boxed e-con e-parent\" data-id=\"95bd826\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-dd9a294 e-con-full e-flex e-con e-child\" data-id=\"dd9a294\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-350f1cc elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"350f1cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"465\" height=\"1024\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-465x1024.webp\" class=\"attachment-large size-large wp-image-494\" alt=\"Ensaio de fuga de l\u00edquido da seringa para o sistema de fecho\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-465x1024.webp 465w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-136x300.webp 136w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-768x1690.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-698x1536.webp 698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-931x2048.webp 931w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-scaled.webp 1164w\" sizes=\"(max-width: 465px) 100vw, 465px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6a72395 e-con-full e-flex e-con e-child\" data-id=\"6a72395\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1a711e6 elementor-widget elementor-widget-heading\" data-id=\"1a711e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Porqu\u00ea escolher <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e791ed8 elementor-widget elementor-widget-text-editor\" data-id=\"e791ed8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>O <strong data-start=\"4377\" data-end=\"4408\">ensaio de fuga de l\u00edquido na seringa<\/strong> \u00e9 essencial para validar a integridade das seringas em aplica\u00e7\u00f5es farmac\u00eauticas. Seguindo as diretrizes definidas pela <strong data-start=\"4527\" data-end=\"4549\">ISO 7886-1 Anexo D<\/strong> e <strong data-start=\"4554\" data-end=\"4578\">ISO 11040-4 Anexo G2<\/strong> garante a conformidade, a fiabilidade do produto e a seguran\u00e7a dos doentes. Confian\u00e7a <strong data-start=\"4646\" data-end=\"4666\">Instrumentos celulares<\/strong> para solu\u00e7\u00f5es de teste especializadas e apoio personalizado para melhorar os seus processos de controlo de qualidade de seringas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c65166e elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"c65166e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/pt\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactar-nos<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Syringe Closure System Liquid Leakage Test In the pharmaceutical and medical device industries, ensuring the integrity of syringes is crucial for product safety and patient health. One of the most essential procedures is the syringe liquid leakage test, which evaluates the ability of a syringe\u2019s plunger and closure system to prevent liquid leaks under pressure. [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-492","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/pages\/492","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/comments?post=492"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/pages\/492\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/media?parent=492"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}