{"id":265,"date":"2025-05-06T03:29:29","date_gmt":"2025-05-06T03:29:29","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=265"},"modified":"2026-05-09T06:39:48","modified_gmt":"2026-05-09T06:39:48","slug":"luer-lock-adaptor-collar-pull-off-force","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/pt\/luer-lock-adaptor-collar-pull-off-force","title":{"rendered":"Adaptador Luer Lock For\u00e7a de extra\u00e7\u00e3o do colarinho"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"265\" class=\"elementor elementor-265\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0ebe6b e-flex e-con-boxed e-con e-parent\" data-id=\"c0ebe6b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d6d91c9 elementor-widget elementor-widget-heading\" data-id=\"d6d91c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Adaptador Luer Lock For\u00e7a de extra\u00e7\u00e3o do colarinho<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0a5f59 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"f0a5f59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nas ind\u00fastrias farmac\u00eautica e de dispositivos m\u00e9dicos, \u00e9 fundamental garantir a integridade dos componentes das seringas. Um controlo de qualidade essencial \u00e9 este teste. Esta avalia\u00e7\u00e3o mede a resist\u00eancia da liga\u00e7\u00e3o entre o colar do adaptador Luer lock (LLA) e o corpo da seringa, evitando a separa\u00e7\u00e3o dos componentes durante a utiliza\u00e7\u00e3o.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7e51b6e e-flex e-con-boxed e-con e-parent\" data-id=\"7e51b6e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a359504 elementor-widget elementor-widget-heading\" data-id=\"a359504\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">A import\u00e2ncia do teste de for\u00e7a de arrancamento do colar do adaptador Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de744c7 elementor-widget elementor-widget-text-editor\" data-id=\"de744c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Se a for\u00e7a de tra\u00e7\u00e3o do colar do adaptador Luer lock for demasiado baixa, o colar pode soltar-se da seringa durante o manuseamento ou a inje\u00e7\u00e3o, provocando fugas de medica\u00e7\u00e3o, dosagem incompleta ou mesmo les\u00f5es graves no doente. Por outro lado, se a for\u00e7a for demasiado elevada, os processos de montagem podem tornar-se dif\u00edceis, aumentando o risco de danos durante o fabrico.<\/p><p>Por conseguinte, a realiza\u00e7\u00e3o deste teste normalizado \u00e9 fundamental para garantir a fixa\u00e7\u00e3o segura do colarinho, manter a fiabilidade funcional da seringa e proteger a seguran\u00e7a do doente.<\/p><p><strong>Syringetest.com<\/strong> oferece equipamento de ensaio preciso e fi\u00e1vel para <em>For\u00e7a de extra\u00e7\u00e3o do colar do adaptador Luer lock<\/em> ajudando a garantir que as suas seringas cumprem as normas de qualidade globais com confian\u00e7a.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f3ad5f2 e-flex e-con-boxed e-con e-parent\" data-id=\"f3ad5f2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d69bf22 elementor-widget elementor-widget-heading\" data-id=\"d69bf22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 e ISO 11040-4 Anexo G3<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c32614c e-con-full e-flex e-con e-child\" data-id=\"c32614c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fcd1b36 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"fcd1b36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>O <a href=\"https:\/\/www.syringetest.com\/pt\/standards\/iso-11040-4\/\"><em>ISO 11040-4<\/em><\/a> norma, nomeadamente <em>ISO 11040-4 Anexo G3<\/em>O regulamento relativo ao procedimento de <em>For\u00e7a de extra\u00e7\u00e3o do colar do adaptador Luer lock<\/em> teste. De acordo com estas normas, o teste de for\u00e7a de arrancamento verifica a capacidade do sistema de colarinho para suportar for\u00e7as axiais, garantindo que as seringas permanecem intactas durante opera\u00e7\u00f5es cr\u00edticas, como a administra\u00e7\u00e3o de medicamentos. O m\u00e9todo enfatiza velocidades de teste consistentes, sele\u00e7\u00e3o adequada da c\u00e9lula de carga e amostragem de alta frequ\u00eancia para garantir dados precisos e fi\u00e1veis.<\/p><p>A seguir <em>ISO 11040-4 Anexo G3<\/em> melhora a consist\u00eancia dos testes entre laborat\u00f3rios e fabricantes, promovendo a confian\u00e7a na qualidade dos produtos e na conformidade regulamentar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0502b44 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"0502b44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"515\" height=\"350\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" class=\"attachment-medium_large size-medium_large wp-image-272\" alt=\"For\u00e7a de extra\u00e7\u00e3o do colar do adaptador Luer Lock - ISO 11040-4 Anexo G3\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp 515w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing-300x204.webp 300w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c33ea3f e-flex e-con-boxed e-con e-parent\" data-id=\"c33ea3f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b8731e5 elementor-widget elementor-widget-heading\" data-id=\"b8731e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Princ\u00edpio do teste de for\u00e7a de arrancamento do colar do adaptador Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-931bcc4 elementor-widget elementor-widget-text-editor\" data-id=\"931bcc4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A ideia central por detr\u00e1s deste teste \u00e9 simples: mede a for\u00e7a axial m\u00e1xima necess\u00e1ria para separar o colar LLA do corpo da seringa. Uma for\u00e7a de extra\u00e7\u00e3o forte significa que o colar LLA est\u00e1 bem fixo, minimizando o risco de desconex\u00e3o durante a utiliza\u00e7\u00e3o.<\/p><p>O princ\u00edpio fundamental centra-se em:<\/p><ul><li>Simula\u00e7\u00e3o de tens\u00f5es mec\u00e2nicas realistas.<\/li><li>Assegurar que as for\u00e7as de inser\u00e7\u00e3o dos acess\u00f3rios Luer normais n\u00e3o causam o desprendimento do colarinho.<\/li><li>Recolha de dados de for\u00e7a de pico atrav\u00e9s da an\u00e1lise de for\u00e7a versus deslocamento.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cbb1f00 e-flex e-con-boxed e-con e-parent\" data-id=\"cbb1f00\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9e34cbf elementor-widget elementor-widget-heading\" data-id=\"9e34cbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Aparelhos e materiais necess\u00e1rios<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29c5058 elementor-widget elementor-widget-text-editor\" data-id=\"29c5058\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Testes exactos de <em>For\u00e7a de extra\u00e7\u00e3o do colar do adaptador Luer lock<\/em> exige equipamento de precis\u00e3o:<\/p><ul><li><strong>M\u00e1quina universal de ensaio de tra\u00e7\u00e3o e compress\u00e3o <\/strong>com:<ul><li>Velocidade de ensaio fixada em 20 mm\/min (de acordo com a norma ISO 80369-7, se adequado).<\/li><li>C\u00e9lula de carga adequada para uma gama de for\u00e7as de 10 N a 100 N.<\/li><\/ul><\/li><li><strong>Suporte de seringa e dispositivo de preens\u00e3o<\/strong> que fixa o corpo da seringa e o colar LLA sem aplicar uma press\u00e3o indesejada.<\/li><\/ul><p><strong>Materiais:<\/strong><\/p><ul><li>Seringas submontadas esterilizadas e prontas para enchimento, incluindo o sistema LLA.<\/li><\/ul><p><strong>Importante:<\/strong><br \/>A taxa de amostragem n\u00e3o deve ser inferior a 100 Hz para os ensaios gerais e a 500 Hz para as medi\u00e7\u00f5es de pico, assegurando uma resolu\u00e7\u00e3o e exatid\u00e3o finas dos dados.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-61d3079 e-flex e-con-boxed e-con e-parent\" data-id=\"61d3079\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bd94a54 elementor-widget elementor-widget-heading\" data-id=\"bd94a54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procedimento de teste da for\u00e7a de extra\u00e7\u00e3o do colar do adaptador Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc41e63 elementor-widget elementor-widget-text-editor\" data-id=\"fc41e63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A realiza\u00e7\u00e3o correta deste teste garante resultados precisos e repet\u00edveis:<\/p><h3>1. Prepara\u00e7\u00e3o da amostra<\/h3><p>Utilizar seringas que tenham sido submetidas a um processo completo de esteriliza\u00e7\u00e3o e prepara\u00e7\u00e3o.<\/p><h3>2. Configura\u00e7\u00e3o<\/h3><ul><li>Retirar cuidadosamente a tampa da ponta.<\/li><li>Fixar a seringa verticalmente entre o suporte (flange de dedo) e a pin\u00e7a (colar LLA) sem for\u00e7ar o colar.<\/li><\/ul><h3>3. Execu\u00e7\u00e3o do teste<\/h3><ul><li>Colocar a c\u00e9lula de carga em zero, assegurando a aus\u00eancia de pr\u00e9-carga.<\/li><li>Aplicar uma for\u00e7a de tra\u00e7\u00e3o de 20 mm\/min.<\/li><li>Registar continuamente a curva for\u00e7a versus deslocamento.<\/li><\/ul><h3>4. Terminar o teste<\/h3><p>Parar o teste quando o colar LLA se separar claramente da seringa.<\/p><h3>5. Registo de resultados<\/h3><p>O pico de for\u00e7a m\u00e1xima na curva representa a <em>for\u00e7a de tra\u00e7\u00e3o<\/em>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc4abbc e-grid e-con-full e-con e-parent\" data-id=\"dc4abbc\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99d351b elementor-widget elementor-widget-image\" data-id=\"99d351b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ccc877e e-con-full e-flex e-con e-child\" data-id=\"ccc877e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef33af7 elementor-widget elementor-widget-heading\" data-id=\"ef33af7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Porqu\u00ea escolher <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b43d751 elementor-widget elementor-widget-text-editor\" data-id=\"b43d751\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"203\" data-end=\"463\">Em <strong>Syringetest.com<\/strong>Na nossa empresa, reunimos experi\u00eancia e inova\u00e7\u00e3o, desde a engenharia de precis\u00e3o ao servi\u00e7o personalizado para apoiar os nossos clientes em todo o mundo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28e0c7c elementor-widget elementor-widget-text-editor\" data-id=\"28e0c7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Realiza\u00e7\u00e3o do <em>For\u00e7a de extra\u00e7\u00e3o do colar do adaptador Luer lock<\/em> teste de acordo com <em>ISO 11040-4 Anexo G3<\/em> \u00e9 vital para garantir a seguran\u00e7a mec\u00e2nica das seringas Luer lock. A execu\u00e7\u00e3o e documenta\u00e7\u00e3o corretas garantem que as seringas podem suportar as tens\u00f5es da utiliza\u00e7\u00e3o cl\u00ednica sem falhas.<br \/>Confiar em <strong>Syringetest.com<\/strong> para solu\u00e7\u00f5es de teste de ponta que elevam a qualidade e a seguran\u00e7a dos seus produtos de seringas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5463cac elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"5463cac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/pt\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactar-nos<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Adaptor Collar Pull-Off Force In the pharmaceutical and medical device industries, ensuring the integrity of syringe components is critical. One essential quality check is the this test. This evaluation measures the strength of the connection between the Luer lock adaptor (LLA) collar and the syringe barrel, preventing component separation during use. The Importance [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-265","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/pages\/265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/comments?post=265"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/pages\/265\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/media?parent=265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}