{"id":154,"date":"2025-04-30T01:31:34","date_gmt":"2025-04-30T01:31:34","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=154"},"modified":"2026-05-09T06:36:31","modified_gmt":"2026-05-09T06:36:31","slug":"finger-flange-breakage-force-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/pt\/finger-flange-breakage-force-test","title":{"rendered":"Ensaio de for\u00e7a de rutura da flange do dedo"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"154\" class=\"elementor elementor-154\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-247db7c e-flex e-con-boxed e-con e-parent\" data-id=\"247db7c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab06118 elementor-widget elementor-widget-heading\" data-id=\"ab06118\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Ensaio de for\u00e7a de rutura da flange do dedo<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62cf733 elementor-widget elementor-widget-text-editor\" data-id=\"62cf733\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>No sector das embalagens farmac\u00eauticas e m\u00e9dicas, <strong>for\u00e7a de rutura da flange de dedo<\/strong> \u00e9 um indicador de desempenho cr\u00edtico para garantir a fiabilidade estrutural dos corpos de seringa. Este par\u00e2metro, definido e normalizado em <strong><em><a href=\"https:\/\/www.syringetest.com\/pt\/standards\/iso-11040-4\/\">ISO 11040-4<\/a> Anexo C1<\/em><\/strong>ajuda os fabricantes e os profissionais de garantia de qualidade a avaliar se o flange da seringa pode suportar o esfor\u00e7o mec\u00e2nico durante o manuseamento e a inje\u00e7\u00e3o.<\/p><p>A compreens\u00e3o desta medida e do seu m\u00e9todo de teste padr\u00e3o \u00e9 vital para os profissionais envolvidos em <strong>teste da seringa<\/strong>especialmente para seringas submontadas est\u00e9reis destinadas a solu\u00e7\u00f5es inject\u00e1veis.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f136d2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f136d2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b673494 elementor-widget elementor-widget-heading\" data-id=\"b673494\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">A import\u00e2ncia da for\u00e7a de rutura da flange do dedo na integridade da seringa<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa819a0 elementor-widget elementor-widget-text-editor\" data-id=\"aa819a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>O <strong>for\u00e7a de rutura da flange de dedo<\/strong> refere-se \u00e0 for\u00e7a mec\u00e2nica m\u00e1xima que a flange de uma seringa pode suportar antes de falhar. Este valor indica a robustez da seringa, especialmente quando os utilizadores aplicam press\u00e3o durante a inje\u00e7\u00e3o ou quando os sistemas de enchimento autom\u00e1tico agarram a seringa.<\/p><p>Uma for\u00e7a de fratura insuficiente pode resultar em fissuras na flange ou numa falha completa, constituindo um risco para a seguran\u00e7a. Por conseguinte, a manuten\u00e7\u00e3o de uma qualidade consistente em todos os lotes n\u00e3o \u00e9 negoci\u00e1vel no fabrico de dispositivos m\u00e9dicos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-37feff9 e-flex e-con-boxed e-con e-parent\" data-id=\"37feff9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3146496 elementor-widget elementor-widget-heading\" data-id=\"3146496\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ensaio de for\u00e7a de rutura da flange do dedo - ISO 11040-4 Anexo C1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08fc359 elementor-widget elementor-widget-text-editor\" data-id=\"08fc359\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>O <strong><a href=\"https:\/\/www.syringetest.com\/pt\/standards\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">ISO 11040-4<\/a> Anexo C1<\/strong> descreve o m\u00e9todo de ensaio para avaliar a resist\u00eancia \u00e0 rutura da flange. O procedimento assegura resultados exactos e repet\u00edveis, tornando-o o padr\u00e3o de ouro nos testes de desempenho de seringas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd10895 e-grid e-con-full e-con e-child\" data-id=\"fd10895\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d98b842 elementor-widget elementor-widget-text-editor\" data-id=\"d98b842\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Objetivo do teste<\/h3><p>Determinar a resist\u00eancia \u00e0 rutura da flange atrav\u00e9s da aplica\u00e7\u00e3o de uma for\u00e7a descendente no corpo da seringa, utilizando equipamento especializado. Este teste avalia tanto a <strong>resist\u00eancia do cilindro de vidro<\/strong> e a sua compatibilidade com o resto do desenho da seringa.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db58dbc elementor-widget elementor-widget-text-editor\" data-id=\"db58dbc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Equipamento necess\u00e1rio<\/h3><ul><li><strong>M\u00e1quina universal de ensaio de tra\u00e7\u00e3o e compress\u00e3o<\/strong>: Deve incluir uma c\u00e9lula de carga adequada e uma velocidade de ensaio configur\u00e1vel de <strong>100 mm\/min<\/strong>.<\/li><li><strong>Suporte de seringa<\/strong>: Normalmente fabricado em PEEK, adaptado \u00e0s dimens\u00f5es da seringa.<\/li><li><strong>Cavilha de carga<\/strong>: Fabricado em poliacetal ou a\u00e7o inoxid\u00e1vel, concebido para aplicar uma for\u00e7a uniforme.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a8c15d0 elementor-widget elementor-widget-image\" data-id=\"a8c15d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"202\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-1024x258.webp\" class=\"attachment-large size-large wp-image-163\" alt=\"Ensaio de for\u00e7a de rutura da flange do dedo da seringa - ISO 11040-4 Anexo C1\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-1024x258.webp 1024w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-300x76.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-768x194.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1.webp 1190w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a78210 e-flex e-con-boxed e-con e-parent\" data-id=\"3a78210\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e89a55d elementor-widget elementor-widget-heading\" data-id=\"e89a55d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Configura\u00e7\u00e3o e execu\u00e7\u00e3o do teste da seringa<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e8f3f2 elementor-widget elementor-widget-text-editor\" data-id=\"2e8f3f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Para efetuar o teste tal como especificado em <strong>Ensaios ISO 11040-4<\/strong>siga estes passos:<\/p><h3>1. Prepara\u00e7\u00e3o da amostra<\/h3><p>Evitar choques ou manuseamento incorreto dos corpos de seringa antes do teste. Inspecionar o suporte e o pino quanto a desgaste.<\/p><h3>2. Configura\u00e7\u00e3o do equipamento<\/h3><ul><li>Colocar a seringa no suporte por baixo da flange.<\/li><li>Alinhar a cavilha de carga para aplicar for\u00e7a na profundidade da flange do cano.<\/li><\/ul><h3>3. Execu\u00e7\u00e3o do teste<\/h3><ul><li>Colocar a m\u00e1quina a funcionar a <strong>100 mm\/min<\/strong>.<\/li><li>Registar o gr\u00e1fico for\u00e7a-deslocamento.<\/li><li>Utilizar um <strong>taxa de amostragem de pelo menos 500 Hz<\/strong> para a dete\u00e7\u00e3o de picos de for\u00e7a.<\/li><\/ul><h3>4. An\u00e1lise dos resultados<\/h3><p>O pico de for\u00e7a observado antes da rotura da flange \u00e9 registado como <strong>for\u00e7a de rutura da flange de dedo<\/strong>. O anexo C1 da norma ISO 11040-4 especifica que este valor, juntamente com a velocidade de ensaio e a contagem de amostras, deve ser registado na documenta\u00e7\u00e3o final.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2d148ee e-grid e-con-full e-con e-parent\" data-id=\"2d148ee\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef5e9b3 elementor-widget elementor-widget-image\" data-id=\"ef5e9b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f83c119 e-con-full e-flex e-con e-child\" data-id=\"f83c119\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-af86f15 elementor-widget elementor-widget-heading\" data-id=\"af86f15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Porqu\u00ea escolher <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-321653d elementor-widget elementor-widget-text-editor\" data-id=\"321653d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>O teste exato da for\u00e7a de rutura de flanges requer instrumentos de elevado desempenho. Em <strong>Syringetest.com<\/strong>A nossa gama de aparelhos de ensaio de tra\u00e7\u00e3o e compress\u00e3o avan\u00e7ados foi concebida para <strong>teste da seringa<\/strong>, em total conformidade com <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><em>ISO 11040-4<\/em><\/a>. Os nossos sistemas est\u00e3o equipados com c\u00e9lulas de carga de precis\u00e3o, velocidades ajust\u00e1veis e software intuitivo para visualiza\u00e7\u00e3o e exporta\u00e7\u00e3o de dados em tempo real.<\/p><p>Tamb\u00e9m oferecemos <strong>suportes de seringas personalizados e integra\u00e7\u00e3o da automatiza\u00e7\u00e3o<\/strong>ajudando a simplificar os testes em ambientes de produ\u00e7\u00e3o de elevado d\u00e9bito.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-262c330 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"262c330\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/pt\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactar-nos<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Finger Flange Breakage Force Testing In the pharmaceutical and medical packaging industry, finger flange breakage force is a critical performance indicator for ensuring the structural reliability of syringe barrels. This parameter, defined and standardized in ISO 11040-4 Annex C1, helps manufacturers and quality assurance professionals assess whether the syringe flange can withstand mechanical stress during [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-154","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/pages\/154","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/comments?post=154"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/pages\/154\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/pt\/wp-json\/wp\/v2\/media?parent=154"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}