{"id":878,"date":"2026-05-08T04:11:57","date_gmt":"2026-05-08T04:11:57","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=878"},"modified":"2026-05-19T07:20:57","modified_gmt":"2026-05-19T07:20:57","slug":"iso-8537","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/pl\/standards\/iso-8537","title":{"rendered":"ISO 8537"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"878\" class=\"elementor elementor-878\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-48d9594 e-flex e-con-boxed e-con e-parent\" data-id=\"48d9594\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-85f9391 elementor-widget elementor-widget-heading\" data-id=\"85f9391\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 8537<br><small>Sterylne strzykawki jednorazowego u\u017cytku, z ig\u0142\u0105 lub bez, do insuliny<\/small><\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aac7d95 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"aac7d95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"356\" data-end=\"891\">Sterylne strzykawki insulinowe wymagaj\u0105 precyzyjnego dzia\u0142ania, aby zapewni\u0107 bezpiecze\u0144stwo pacjenta, dok\u0142adno\u015b\u0107 dawkowania i niezawodne dostarczanie leku. <strong data-start=\"491\" data-end=\"503\">ISO 8537<\/strong> okre\u015bla wymagania i odpowiadaj\u0105ce im metody testowania sterylnych strzykawek jednorazowego u\u017cytku, z ig\u0142ami lub bez, przeznaczonych do wstrzykiwania insuliny. Norma koncentruje si\u0119 na krytycznych cechach, takich jak odporno\u015b\u0107 na wycieki, si\u0142a dzia\u0142ania t\u0142oka, przestrze\u0144 martwa i integralno\u015b\u0107 po\u0142\u0105czenia mi\u0119dzy elementami strzykawki, w tym <strong data-start=\"831\" data-end=\"890\">dysza, piasta, iglica, cylinder, t\u0142ok i gumowy korek<\/strong>.<\/p><p data-start=\"893\" data-end=\"1221\">Dla producent\u00f3w strzykawek i laboratori\u00f3w kontroli jako\u015bci, zgodno\u015b\u0107 z <strong data-start=\"969\" data-end=\"981\">ISO 8537<\/strong> pomaga zweryfikowa\u0107 sp\u00f3jno\u015b\u0107 produktu, zmniejszy\u0107 ryzyko wycieku i poprawi\u0107 wydajno\u015b\u0107 wstrzykiwania podczas zastosowa\u0144 klinicznych. Nowoczesne systemy testowe obs\u0142uguj\u0105 r\u00f3wnie\u017c zautomatyzowane pozyskiwanie danych, analiz\u0119 powtarzalno\u015bci i identyfikowaln\u0105 dokumentacj\u0119 jako\u015bci.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-34af957 e-flex e-con-boxed e-con e-parent\" data-id=\"34af957\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dc7d0ed elementor-widget elementor-widget-heading\" data-id=\"dc7d0ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wymagania normy ISO 8537 dotycz\u0105ce testowania wydajno\u015bci strzykawek<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-413ec4f elementor-widget elementor-widget-text-editor\" data-id=\"413ec4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1286\" data-end=\"1440\">Norma ISO 8537 ustanawia wiele procedur weryfikacji w celu oceny w\u0142a\u015bciwo\u015bci mechanicznych i uszczelniaj\u0105cych sterylnych strzykawek insulinowych. Norma obejmuje:<\/p><ul data-start=\"1442\" data-end=\"1681\"><li data-section-id=\"1lghe2x\" data-start=\"1442\" data-end=\"1478\">Wydajno\u015b\u0107 uszczelnienia t\u0142oka strzykawki<\/li><li data-section-id=\"km50lt\" data-start=\"1479\" data-end=\"1503\">Odporno\u015b\u0107 na przecieki powietrza<\/li><li data-section-id=\"413t8n\" data-start=\"1504\" data-end=\"1531\">Odporno\u015b\u0107 na wycieki cieczy<\/li><li data-section-id=\"vzeopp\" data-start=\"1532\" data-end=\"1558\">Okre\u015blanie martwej przestrzeni<\/li><li data-section-id=\"87u2zy\" data-start=\"1559\" data-end=\"1596\">Testowanie luzu i si\u0142y po\u015blizgu<\/li><li data-section-id=\"1r4pkcu\" data-start=\"1597\" data-end=\"1634\">Integralno\u015b\u0107 po\u0142\u0105czenia ig\u0142y i piasty<\/li><li data-section-id=\"1cxbo49\" data-start=\"1635\" data-end=\"1681\">Zdolno\u015b\u0107 strzykawkowania i wstrzykiwania<\/li><\/ul><p data-start=\"1683\" data-end=\"1855\">Oceny te zapewniaj\u0105, \u017ce strzykawka zachowuje szczelno\u015b\u0107 podczas zasysania i wstrzykiwania, zapewniaj\u0105c jednocze\u015bnie p\u0142ynny ruch t\u0142oka i dok\u0142adne dozowanie.<\/p><p data-start=\"1857\" data-end=\"1907\">Dla producent\u00f3w testy te maj\u0105 bezpo\u015bredni wp\u0142yw:<\/p><ul data-start=\"1909\" data-end=\"2019\"><li data-section-id=\"1kgf4fz\" data-start=\"1909\" data-end=\"1925\">Bezpiecze\u0144stwo produktu<\/li><li data-section-id=\"fw7gsx\" data-start=\"1926\" data-end=\"1945\">Komfort wtrysku<\/li><li data-section-id=\"4fq85f\" data-start=\"1946\" data-end=\"1962\">Precyzja dawki<\/li><li data-section-id=\"1yh82kt\" data-start=\"1963\" data-end=\"1986\">Zgodno\u015b\u0107 z przepisami<\/li><li data-section-id=\"1lk2gtk\" data-start=\"1987\" data-end=\"2019\">Sp\u00f3jno\u015b\u0107 jako\u015bci produkcji<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-38a36c9 e-flex e-con-boxed e-con e-parent\" data-id=\"38a36c9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ba9a815 elementor-widget elementor-widget-heading\" data-id=\"ba9a815\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test strzykawkowalno\u015bci i wstrzykiwalno\u015bci zgodnie z norm\u0105 ISO 8537<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-89fad34 e-con-full e-flex e-con e-child\" data-id=\"89fad34\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a2a949 elementor-widget elementor-widget-text-editor\" data-id=\"3a2a949\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2090\" data-end=\"2310\">The <strong data-start=\"2094\" data-end=\"2135\">Test strzykawkowalno\u015bci i wstrzykiwalno\u015bci<\/strong> ocenia charakterystyk\u0119 operacyjn\u0105 t\u0142oka strzykawki podczas podawania p\u0142ynu. Za\u0142\u0105cznik C do normy ISO 8537 definiuje okre\u015blenie si\u0142 wymaganych do obs\u0142ugi t\u0142oka.<\/p><p data-start=\"2312\" data-end=\"2333\">Podczas procedury:<\/p><ol data-start=\"2335\" data-end=\"2663\"><li data-section-id=\"200s8h\" data-start=\"2335\" data-end=\"2408\">Strzykawka jest nape\u0142niona wod\u0105 destylowan\u0105 do 50% pojemno\u015bci nominalnej.<\/li><li data-section-id=\"mdao9q\" data-start=\"2409\" data-end=\"2478\">Strzykawka jest zamocowana pionowo z ig\u0142\u0105 skierowan\u0105 w d\u00f3\u0142.<\/li><li data-section-id=\"l6yed3\" data-start=\"2479\" data-end=\"2533\">Do t\u0142oka przyk\u0142adana jest kontrolowana si\u0142a osiowa.<\/li><li data-section-id=\"16cx4j2\" data-start=\"2534\" data-end=\"2596\">Rejestrowana jest si\u0142a wymagana do zainicjowania ruchu t\u0142oka.<\/li><li data-section-id=\"7rurb5\" data-start=\"2597\" data-end=\"2663\">Mierzona jest r\u00f3wnie\u017c ci\u0105g\u0142a si\u0142a wymagana do utrzymania ruchu.<\/li><\/ol><p data-start=\"2665\" data-end=\"2714\">Proces ten okre\u015bla dwa wa\u017cne parametry:<\/p><ul data-start=\"2716\" data-end=\"2866\"><li data-section-id=\"fbhnrm\" data-start=\"2716\" data-end=\"2791\"><strong data-start=\"2718\" data-end=\"2739\">Si\u0142a zrywaj\u0105ca<\/strong> - pocz\u0105tkowa si\u0142a potrzebna do rozpocz\u0119cia ruchu t\u0142oka<\/li><li data-section-id=\"1wcea99\" data-start=\"2792\" data-end=\"2866\"><strong data-start=\"2794\" data-end=\"2809\">Si\u0142a po\u015blizgu<\/strong> - ci\u0105g\u0142a si\u0142a potrzebna do utrzymania ruchu t\u0142oka<\/li><\/ul><p data-start=\"2868\" data-end=\"3028\">Nadmierna si\u0142a zrywaj\u0105ca mo\u017ce powodowa\u0107 niewygodn\u0105 prac\u0119 wtrysku, podczas gdy niestabilna si\u0142a po\u015blizgu mo\u017ce negatywnie wp\u0142ywa\u0107 na kontrol\u0119 wtrysku i dok\u0142adno\u015b\u0107 dozowania.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9edb986 elementor-widget elementor-widget-image\" data-id=\"9edb986\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"982\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-834x1024.webp\" class=\"attachment-large size-large wp-image-891\" alt=\"ISO 8537 Za\u0142\u0105cznik C\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-834x1024.webp 834w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-244x300.webp 244w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-768x943.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-1251x1536.webp 1251w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-1668x2048.webp 1668w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-10x12.webp 10w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C.webp 1848w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">ISO 8537 Za\u0142\u0105cznik C<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4f5b350 e-con-full e-flex e-con e-child\" data-id=\"4f5b350\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b02950d elementor-widget elementor-widget-image\" data-id=\"b02950d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/elementor\/thumbs\/SSR-01-Syringe-Sliding-Resistance-Tester-scaled-rn4ztcwa0vu2nv5accvgu3o8gcq1q0c2tqpka41udw.webp\" title=\"SSR-01 Tester oporu przesuwu strzykawki\" alt=\"SSR-01 Tester oporu przesuwu strzykawki\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">SSR-01 Tester oporu przesuwu strzykawki<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9da22d5 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"9da22d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 data-section-id=\"1qgfchs\" data-start=\"3030\" data-end=\"3069\">Testowanie si\u0142y zrywania i po\u015blizgu<\/h3><p data-start=\"3071\" data-end=\"3207\"><strong data-start=\"3071\" data-end=\"3110\">Testowanie luzu i si\u0142y po\u015blizgu<\/strong> odgrywa kluczow\u0105 rol\u0119 w ocenie u\u017cyteczno\u015bci strzykawki. Wysokiej jako\u015bci strzykawki powinny wykazywa\u0107<\/p><ul data-start=\"3209\" data-end=\"3319\"><li data-section-id=\"13vpip9\" data-start=\"3209\" data-end=\"3231\">P\u0142ynny ruch t\u0142oka<\/li><li data-section-id=\"6p5d4b\" data-start=\"3232\" data-end=\"3258\">Stabilne zachowanie podczas tarcia<\/li><li data-section-id=\"7wl59y\" data-start=\"3259\" data-end=\"3286\">Minimalne wahania si\u0142y<\/li><li data-section-id=\"xdgzww\" data-start=\"3287\" data-end=\"3319\">Niezawodne dzia\u0142anie smaru<\/li><\/ul><p data-start=\"3321\" data-end=\"3459\">Uniwersalna maszyna do testowania materia\u0142\u00f3w wyposa\u017cona w czujniki si\u0142y i niestandardowe uchwyty strzykawkowe mo\u017ce dok\u0142adnie zmierzy\u0107 te parametry.<\/p><p data-start=\"3461\" data-end=\"3550\">Cell Instruments poleca precyzyjne systemy do pr\u00f3b \u015bciskania i rozci\u0105gania zdolne do:<\/p><ul data-start=\"3552\" data-end=\"3716\"><li data-section-id=\"t8upzl\" data-start=\"3552\" data-end=\"3587\">Pozyskiwanie si\u0142y w wysokiej rozdzielczo\u015bci<\/li><li data-section-id=\"2nuhzd\" data-start=\"3588\" data-end=\"3625\">Krzywe si\u0142a-przemieszczenie w czasie rzeczywistym<\/li><li data-section-id=\"1ajf2el\" data-start=\"3626\" data-end=\"3662\">Programowalna kontrola pr\u0119dko\u015bci testowania<\/li><li data-section-id=\"wk2t5e\" data-start=\"3663\" data-end=\"3716\">Analiza statystyczna na potrzeby weryfikacji jako\u015bci partii<\/li><\/ul><p data-start=\"3718\" data-end=\"3843\">Systemy te pomagaj\u0105 producentom strzykawek zoptymalizowa\u0107 wyko\u0144czenie powierzchni cylindra, geometri\u0119 t\u0142oka i procesy smarowania silikonem.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7d5e890 e-flex e-con-boxed e-con e-parent\" data-id=\"7d5e890\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a7e615 elementor-widget elementor-widget-heading\" data-id=\"3a7e615\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test szczelno\u015bci sterylnej strzykawki jednorazowego u\u017cytku<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2a1077b e-con-full e-flex e-con e-child\" data-id=\"2a1077b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bdb9680 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"bdb9680\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3898\" data-end=\"4086\"><strong data-start=\"3898\" data-end=\"3945\">Test szczelno\u015bci sterylnej strzykawki jednorazowego u\u017cytku<\/strong> produkty to jedna z najwa\u017cniejszych sekcji normy ISO 8537, poniewa\u017c wyciek mo\u017ce zagrozi\u0107 sterylno\u015bci, dok\u0142adno\u015bci iniekcji i bezpiecze\u0144stwu pacjenta.<\/p><p data-start=\"4088\" data-end=\"4116\">Standard ocenia oba te elementy:<\/p><ul data-start=\"4118\" data-end=\"4185\"><li data-section-id=\"1oxsryt\" data-start=\"4118\" data-end=\"4149\">Wyciek powietrza podczas zasysania<\/li><li data-section-id=\"1hssqyx\" data-start=\"4150\" data-end=\"4185\">Wyciek cieczy podczas kompresji<\/li><\/ul><p data-start=\"4187\" data-end=\"4253\">Testowanie szczelno\u015bci obejmuje kilka element\u00f3w strzykawki, w tym:<\/p><ul data-start=\"4255\" data-end=\"4325\"><li data-section-id=\"1vo9gki\" data-start=\"4255\" data-end=\"4263\">Beczka<\/li><li data-section-id=\"30utxz\" data-start=\"4264\" data-end=\"4272\">T\u0142ok<\/li><li data-section-id=\"152o3t3\" data-start=\"4273\" data-end=\"4289\">Gumowy korek<\/li><li data-section-id=\"1t04wdn\" data-start=\"4290\" data-end=\"4298\">Ig\u0142a<\/li><li data-section-id=\"1o447r\" data-start=\"4299\" data-end=\"4304\">Hub<\/li><li data-section-id=\"ergued\" data-start=\"4305\" data-end=\"4325\">Po\u0142\u0105czenia dysz<\/li><\/ul><p data-start=\"4327\" data-end=\"4446\">Niezawodna wydajno\u015b\u0107 uszczelnienia zapewnia, \u017ce \u017caden p\u0142yn ani powietrze nie omija interfejs\u00f3w uszczelniaj\u0105cych podczas normalnych warunk\u00f3w u\u017cytkowania.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0151446 elementor-widget elementor-widget-image\" data-id=\"0151446\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"464\" height=\"1024\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-464x1024.png\" class=\"attachment-large size-large wp-image-895\" alt=\"ISO 8537 Schematyczne przedstawienie strzykawki insulinowej do jednorazowego u\u017cytku\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-464x1024.png 464w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-136x300.png 136w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-768x1695.png 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-696x1536.png 696w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-5x12.png 5w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use.png 852w\" sizes=\"(max-width: 464px) 100vw, 464px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26e3b02 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"26e3b02\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table width=\"269\"><tbody><tr><td width=\"20\">1<\/td><td width=\"100\">nasadka ig\u0142y<\/td><td width=\"28\">10<\/td><td width=\"121\">nasadka t\u0142oka<\/td><\/tr><tr><td width=\"20\">2<\/td><td width=\"100\">za\u015blepka dyszy<\/td><td width=\"28\">11<\/td><td width=\"121\">uchwyty na palce<\/td><\/tr><tr><td width=\"20\">3<\/td><td width=\"100\">prze\u015bwit dyszy<\/td><td width=\"28\">12<\/td><td width=\"121\">linia odniesienia<\/td><\/tr><tr><td width=\"20\">4<\/td><td width=\"100\">dysza<\/td><td width=\"28\">13<\/td><td width=\"121\">pojemno\u015b\u0107 nominalna<\/td><\/tr><tr><td width=\"20\">5<\/td><td width=\"100\">beczka<\/td><td width=\"28\">14<\/td><td width=\"121\">linie stopniowania<\/td><\/tr><tr><td width=\"20\">6<\/td><td width=\"100\">zatyczka t\u0142oka<\/td><td width=\"28\">15<\/td><td width=\"121\">linia zerowa<\/td><\/tr><tr><td width=\"20\">7<\/td><td width=\"100\">uszczelki<\/td><td width=\"28\">16<\/td><td width=\"121\">rurka ig\u0142owa<\/td><\/tr><tr><td width=\"20\">8<\/td><td width=\"100\">t\u0142ok<\/td><td width=\"28\">17<\/td><td width=\"121\">piasta<\/td><\/tr><tr><td width=\"20\">9<\/td><td width=\"100\">przycisk<\/td><td>\u00a0<\/td><td>\u00a0<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5ca68da e-flex e-con-boxed e-con e-parent\" data-id=\"5ca68da\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c08b839 elementor-widget elementor-widget-heading\" data-id=\"c08b839\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test szczelno\u015bci strzykawki i metody wykrywania nieszczelno\u015bci pr\u00f3\u017cniowej<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1de7ad8 elementor-widget elementor-widget-text-editor\" data-id=\"1de7ad8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4516\" data-end=\"4635\">The <strong data-start=\"4520\" data-end=\"4548\">Test szczelno\u015bci strzykawki<\/strong> opisany w Za\u0142\u0105czniku B i Za\u0142\u0105czniku F ocenia wyciek w warunkach podci\u015bnienia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-662d174 e-con-full e-flex e-con e-child\" data-id=\"662d174\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-e09dc78 e-con-full e-flex e-con e-child\" data-id=\"e09dc78\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6604812 elementor-widget elementor-widget-text-editor\" data-id=\"6604812\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4637\" data-end=\"4847\">W za\u0142\u0105czniku B dysza strzykawki \u0142\u0105czy si\u0119 z \u0142\u0105cznikiem referencyjnym, a strzykawka jest cz\u0119\u015bciowo wype\u0142niona wod\u0105. Podci\u015bnienie <strong data-start=\"4760\" data-end=\"4797\">88 kPa poni\u017cej ci\u015bnienia atmosferycznego<\/strong> jest stopniowo stosowana. Nast\u0119pnie operator sprawdza:<\/p><ul data-start=\"4849\" data-end=\"4972\"><li data-section-id=\"nfom55\" data-start=\"4849\" data-end=\"4883\">Wyciek powietrza przez uszczelk\u0119 t\u0142oka<\/li><li data-section-id=\"cbijpf\" data-start=\"4884\" data-end=\"4920\">Stabilno\u015b\u0107 ci\u015bnienia przez 60 sekund<\/li><li data-section-id=\"y5dh1c\" data-start=\"4921\" data-end=\"4972\">Oddzielenie gumowego korka od t\u0142oka<\/li><\/ul><p data-start=\"4974\" data-end=\"5081\">Procedura ta jest jedn\u0105 z najskuteczniejszych <strong data-start=\"5026\" data-end=\"5059\">podci\u015bnieniowe metody wykrywania nieszczelno\u015bci<\/strong> do strzykawek insulinowych.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-367cbd1 elementor-widget elementor-widget-image\" data-id=\"367cbd1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"429\" height=\"343\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-B.webp\" class=\"attachment-large size-large wp-image-883\" alt=\"ISO 8537 Za\u0142\u0105cznik B Wyciek powietrza podczas aspiracji\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-B.webp 429w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-B-300x240.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-B-15x12.webp 15w\" sizes=\"(max-width: 429px) 100vw, 429px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">ISO 8537 Za\u0142\u0105cznik B Wyciek powietrza podczas aspiracji<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b2032f elementor-widget elementor-widget-image\" data-id=\"6b2032f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"679\" height=\"1024\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-679x1024.webp\" class=\"attachment-large size-large wp-image-884\" alt=\"SLT-02 Tester szczelno\u015bci strzykawki\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-679x1024.webp 679w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-199x300.webp 199w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-768x1158.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1019x1536.webp 1019w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1358x2048.webp 1358w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-8x12.webp 8w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp 1698w\" sizes=\"(max-width: 679px) 100vw, 679px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Tester szczelno\u015bci strzykawek SLT-02<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2baf071 e-flex e-con-boxed e-con e-parent\" data-id=\"2baf071\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3458faa elementor-widget elementor-widget-heading\" data-id=\"3458faa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test wycieku cieczy ze strzykawki pod ci\u015bnieniem<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e6d789e e-con-full e-flex e-con e-child\" data-id=\"e6d789e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d45890 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"7d45890\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"5667\" data-end=\"5789\">The <strong data-start=\"5671\" data-end=\"5702\">Test szczelno\u015bci strzykawki<\/strong> okre\u015blony w za\u0142\u0105czniku E ocenia skuteczno\u015b\u0107 uszczelnienia w warunkach ci\u015bnienia wewn\u0119trznego.<\/p><p data-start=\"5791\" data-end=\"5806\">Strzykawka jest:<\/p><ol data-start=\"5808\" data-end=\"5928\"><li data-section-id=\"6wnabh\" data-start=\"5808\" data-end=\"5841\">Nape\u0142niony powy\u017cej pojemno\u015bci nominalnej<\/li><li data-section-id=\"1fqlmrf\" data-start=\"5842\" data-end=\"5858\">Oczyszczony z powietrza<\/li><li data-section-id=\"1qsq13s\" data-start=\"5859\" data-end=\"5884\">Ci\u015bnienie do 300 kPa<\/li><li data-section-id=\"96c87l\" data-start=\"5885\" data-end=\"5928\">Utrzymywany pod ci\u015bnieniem przez 30 sekund<\/li><\/ol><p data-start=\"5930\" data-end=\"5967\">Podczas testu inspektorzy oceniaj\u0105:<\/p><ul data-start=\"5969\" data-end=\"6054\"><li data-section-id=\"yefbo4\" data-start=\"5969\" data-end=\"5986\">Ruch t\u0142oka<\/li><li data-section-id=\"te6jnt\" data-start=\"5987\" data-end=\"6014\">Przeciek przez uszczelki t\u0142oka<\/li><li data-section-id=\"hl3ixi\" data-start=\"6015\" data-end=\"6054\">Wyciek na z\u0142\u0105czach dyszy lub iglicy<\/li><\/ul><p data-start=\"6056\" data-end=\"6141\">Metoda ta weryfikuje integralno\u015b\u0107 interfejs\u00f3w uszczelniaj\u0105cych podczas symulacji wtrysku.<\/p><p data-start=\"6143\" data-end=\"6227\">Prawid\u0142owo zaprojektowany system testowania szczelno\u015bci ci\u015bnieniowej mo\u017ce pom\u00f3c producentom w ocenie:<\/p><ul data-start=\"6229\" data-end=\"6353\"><li data-section-id=\"swbrf5\" data-start=\"6229\" data-end=\"6261\">Jako\u015b\u0107 uszczelnienia gumowego korka<\/li><li data-section-id=\"1ekpexs\" data-start=\"6262\" data-end=\"6291\">Niezawodno\u015b\u0107 po\u0142\u0105czenia Luer<\/li><li data-section-id=\"1dtrbjl\" data-start=\"6292\" data-end=\"6324\">Sp\u00f3jno\u015b\u0107 wymiarowa lufy<\/li><li data-section-id=\"1wg6zas\" data-start=\"6325\" data-end=\"6353\">Wydajno\u015b\u0107 klejenia ig\u0142\u0105<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e65e0c6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"e65e0c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"465\" height=\"1024\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-465x1024.webp\" class=\"attachment-large size-large wp-image-885\" alt=\"SPPT-01 Tester szczelno\u015bci nadci\u015bnieniowej strzykawki\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-465x1024.webp 465w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-136x300.webp 136w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-768x1690.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-698x1536.webp 698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-931x2048.webp 931w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-5x12.webp 5w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-scaled.webp 1164w\" sizes=\"(max-width: 465px) 100vw, 465px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">SPPT-01 Tester szczelno\u015bci nadci\u015bnieniowej strzykawki<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4073de e-flex e-con-boxed e-con e-parent\" data-id=\"d4073de\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-758cd11 elementor-widget elementor-widget-heading\" data-id=\"758cd11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pomiar przestrzeni martwej dla dok\u0142adno\u015bci strzykawki<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6da682f elementor-widget elementor-widget-text-editor\" data-id=\"6da682f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"6408\" data-end=\"6526\"><strong data-start=\"6408\" data-end=\"6434\">Pomiar martwej przestrzeni<\/strong> ma zasadnicze znaczenie dla strzykawek insulinowych, poniewa\u017c pozosta\u0142o\u015bci p\u0142ynu bezpo\u015brednio wp\u0142ywaj\u0105 na precyzj\u0119 dawkowania.<\/p><p data-start=\"6528\" data-end=\"6620\">Norma ISO 8537 definiuje przestrze\u0144 martw\u0105 jako pozosta\u0142\u0105 obj\u0119to\u015b\u0107 wody po ca\u0142kowitym wci\u015bni\u0119ciu t\u0142oka.<\/p><p data-start=\"6622\" data-end=\"6645\">Procedura obejmuje:<\/p><ul data-start=\"6647\" data-end=\"6775\"><li data-section-id=\"14dqth4\" data-start=\"6647\" data-end=\"6684\">Dok\u0142adne wa\u017cenie pustych strzykawek<\/li><li data-section-id=\"6xmjzm\" data-start=\"6685\" data-end=\"6715\">Nape\u0142nianie wod\u0105 destylowan\u0105<\/li><li data-section-id=\"1y173or\" data-start=\"6716\" data-end=\"6746\">Ca\u0142kowite wydalenie p\u0142ynu<\/li><li data-section-id=\"fuewb\" data-start=\"6747\" data-end=\"6775\">Ponowne wa\u017cenie po roz\u0142adowaniu<\/li><\/ul><p data-start=\"6777\" data-end=\"6827\">Pozosta\u0142a masa odpowiada obj\u0119to\u015bci resztkowej.<\/p><p data-start=\"6829\" data-end=\"6858\">Pomagaj\u0105 w tym strzykawki o niskiej przestrzeni martwej:<\/p><ul data-start=\"6860\" data-end=\"6950\"><li data-section-id=\"xvtq2v\" data-start=\"6860\" data-end=\"6885\">Zmniejszenie ilo\u015bci odpad\u00f3w lek\u00f3w<\/li><li data-section-id=\"juz4tb\" data-start=\"6886\" data-end=\"6912\">Poprawa precyzji dawkowania<\/li><li data-section-id=\"10nqsv3\" data-start=\"6913\" data-end=\"6950\">Minimalizacja retencji resztkowej insuliny<\/li><\/ul><p data-start=\"6952\" data-end=\"7092\">Urz\u0105dzenia testuj\u0105ce z wagami analitycznymi i kontrolowanymi uchwytami poprawiaj\u0105 sp\u00f3jno\u015b\u0107 pomiar\u00f3w w programach zapewniania jako\u015bci.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c7f4aa5 e-flex e-con-boxed e-con e-parent\" data-id=\"c7f4aa5\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9a263b1 elementor-widget elementor-widget-heading\" data-id=\"9a263b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Znaczenie testowania komponent\u00f3w strzykawki<br><small>---Dysza, piasta, ig\u0142a, cylinder, t\u0142ok i gumowy korek<\/small><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-088c9f2 elementor-widget elementor-widget-text-editor\" data-id=\"088c9f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"7201\" data-end=\"7307\">Testy ISO 8537 oceniaj\u0105 interakcj\u0119 mi\u0119dzy wieloma komponentami strzykawki, a nie izolowanymi cz\u0119\u015bciami.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ee707f7 e-con-full e-flex e-con e-child\" data-id=\"ee707f7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-af54839 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"af54839\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"7201\" data-end=\"7307\">\u00a0Krytyczne interfejsy obejmuj\u0105:<\/p><div class=\"TyagGW_tableContainer\"><div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"7339\" data-end=\"7613\"><thead data-start=\"7339\" data-end=\"7376\"><tr data-start=\"7339\" data-end=\"7376\"><th class=\"\" data-start=\"7339\" data-end=\"7351\" data-col-size=\"sm\">Komponent<\/th><th class=\"\" data-start=\"7351\" data-end=\"7376\" data-col-size=\"sm\">Znaczenie funkcjonalne<\/th><\/tr><\/thead><tbody data-start=\"7387\" data-end=\"7613\"><tr data-start=\"7387\" data-end=\"7424\"><td data-start=\"7387\" data-end=\"7396\" data-col-size=\"sm\">Dysza<\/td><td data-start=\"7396\" data-end=\"7424\" data-col-size=\"sm\">Integralno\u015b\u0107 transferu p\u0142yn\u00f3w<\/td><\/tr><tr data-start=\"7425\" data-end=\"7462\"><td data-start=\"7425\" data-end=\"7431\" data-col-size=\"sm\">Hub<\/td><td data-start=\"7431\" data-end=\"7462\" data-col-size=\"sm\">Stabilno\u015b\u0107 po\u0142\u0105czenia ig\u0142y<\/td><\/tr><tr data-start=\"7463\" data-end=\"7497\"><td data-start=\"7463\" data-end=\"7472\" data-col-size=\"sm\">Ig\u0142a<\/td><td data-start=\"7472\" data-end=\"7497\" data-col-size=\"sm\">Wydajno\u015b\u0107 wtrysku<\/td><\/tr><tr data-start=\"7498\" data-end=\"7531\"><td data-start=\"7498\" data-end=\"7507\" data-col-size=\"sm\">Beczka<\/td><td data-start=\"7507\" data-end=\"7531\" data-col-size=\"sm\">Dok\u0142adno\u015b\u0107 wymiarowa<\/td><\/tr><tr data-start=\"7532\" data-end=\"7573\"><td data-start=\"7532\" data-end=\"7541\" data-col-size=\"sm\">T\u0142ok<\/td><td data-start=\"7541\" data-end=\"7573\" data-col-size=\"sm\">P\u0142ynne dzia\u0142anie i uszczelnienie<\/td><\/tr><tr data-start=\"7574\" data-end=\"7613\"><td data-start=\"7574\" data-end=\"7591\" data-col-size=\"sm\">Gumowy korek<\/td><td data-start=\"7591\" data-end=\"7613\" data-col-size=\"sm\">Zapobieganie wyciekom<\/td><\/tr><\/tbody><\/table><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2b1852b elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"2b1852b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"7615\" data-end=\"7668\">Wszelkie niesp\u00f3jno\u015bci mi\u0119dzy tymi komponentami mog\u0105 prowadzi\u0107 do:<\/p><ul data-start=\"7670\" data-end=\"7749\"><li data-section-id=\"ujvyq0\" data-start=\"7670\" data-end=\"7679\">Wyciek<\/li><li data-section-id=\"1g1kth9\" data-start=\"7680\" data-end=\"7703\">Niestabilno\u015b\u0107 wtrysku<\/li><li data-section-id=\"rmryg9\" data-start=\"7704\" data-end=\"7731\">Nadmierna si\u0142a robocza<\/li><li data-section-id=\"17chdkf\" data-start=\"7732\" data-end=\"7749\">Niedok\u0142adno\u015b\u0107 dawki<\/li><\/ul><p data-start=\"7751\" data-end=\"7845\">Kompleksowe testy wymagaj\u0105 zatem zintegrowanych system\u00f3w oceny mechanicznej i szczelno\u015bci.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Norma ISO 8537 definiuje krytyczne metody testowania sterylnych jednorazowych strzykawek insulinowych, w tym testowanie szczelno\u015bci strzykawki, procedury testowania integralno\u015bci uszczelnienia strzykawki, testowanie si\u0142y po\u015blizgu strzykawki i pomiar przestrzeni martwej.<\/p>","protected":false},"author":2,"featured_media":0,"parent":603,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-878","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages\/878","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/comments?post=878"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages\/878\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages\/603"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/media?parent=878"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}