{"id":608,"date":"2025-07-02T05:36:28","date_gmt":"2025-07-02T05:36:28","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=608"},"modified":"2026-05-19T07:09:42","modified_gmt":"2026-05-19T07:09:42","slug":"iso-7886-1","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/pl\/standards\/iso-7886-1","title":{"rendered":"ISO 7886-1"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"608\" class=\"elementor elementor-608\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f03c7a9 e-flex e-con-boxed e-con e-parent\" data-id=\"f03c7a9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1212df8 elementor-widget elementor-widget-heading\" data-id=\"1212df8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Standard testowania funkcjonalno\u015bci strzykawek ISO 7886-1<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1cd79c0 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"1cd79c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"389\" data-end=\"862\"><strong data-start=\"408\" data-end=\"422\">ISO 7886-1<\/strong> to uznawany na ca\u0142ym \u015bwiecie standard, kt\u00f3ry definiuje wymagania dotycz\u0105ce wydajno\u015bci i testowania dla <em data-start=\"524\" data-end=\"599\">sterylne strzykawki podsk\u00f3rne do jednorazowego u\u017cytku, przeznaczone do u\u017cytku r\u0119cznego<\/em>. Norma ta odgrywa istotn\u0105 rol\u0119 w kontroli jako\u015bci strzykawek, zapewniaj\u0105c bezpiecze\u0144stwo funkcjonalne i ochron\u0119 pacjent\u00f3w. In\u017cynierowie kontroli jako\u015bci i specjali\u015bci ds. regulacji polegaj\u0105 na tym dokumencie, aby kierowa\u0107 <em data-start=\"797\" data-end=\"828\">Testowanie funkcjonalno\u015bci strzykawki<\/em> i zweryfikowa\u0107 wydajno\u015b\u0107 produktu. Od <strong data-start=\"869\" data-end=\"908\">Testowanie luzu i si\u0142y po\u015blizgu<\/strong> do <strong data-start=\"912\" data-end=\"936\">Testowanie szczelno\u015bci strzykawki<\/strong>Norma ISO 7886-1 okre\u015bla precyzyjne metody testowe do oceny integralno\u015bci strzykawki.\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1cadcda e-flex e-con-boxed e-con e-parent\" data-id=\"1cadcda\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5506c95 elementor-widget elementor-widget-heading\" data-id=\"5506c95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kluczowe wymagania dotycz\u0105ce wydajno\u015bci zgodnie z norm\u0105 ISO 7886-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd9cbb4 elementor-widget elementor-widget-text-editor\" data-id=\"dd9cbb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Dead Space<\/h3><p data-start=\"347\" data-end=\"741\">Aby ograniczy\u0107 marnotrawstwo lek\u00f3w i zminimalizowa\u0107 ryzyko zaka\u017cenia krzy\u017cowego, norma ISO 7886-1 wymaga, aby martwa przestrze\u0144 strzykawki - pozosta\u0142a obj\u0119to\u015b\u0107 p\u0142ynu po pe\u0142nym w\u0142o\u017ceniu t\u0142oka - by\u0142a ograniczona do minimum.<\/p><h3>Wyciek powietrza i cieczy<\/h3><p data-start=\"743\" data-end=\"1267\">Strzykawki musz\u0105 wykazywa\u0107 solidne w\u0142a\u015bciwo\u015bci uszczelniaj\u0105ce. Zgodnie z <em data-start=\"850\" data-end=\"859\">Za\u0142\u0105cznik D<\/em>powinno by\u0107 <strong data-start=\"877\" data-end=\"908\">brak widocznych wyciek\u00f3w wody<\/strong> za ogranicznik t\u0142oka lub uszczelk\u0119 pod wp\u0142ywem \u015bciskania. Podczas gdy ma\u0142e kropelki pomi\u0119dzy wewn\u0119trznymi uszczelkami s\u0105 dopuszczalne, wyciek zewn\u0119trzny stanowi awari\u0119. Dodatkowo, <em data-start=\"1076\" data-end=\"1085\">Za\u0142\u0105cznik B<\/em> nakazuje, aby <strong data-start=\"1100\" data-end=\"1118\">brak wyciek\u00f3w powietrza<\/strong> lub spadek podci\u015bnienia mo\u017ce wyst\u0105pi\u0107 podczas testu zasysania. Kryteria te zapewniaj\u0105 integralno\u015b\u0107 bariery strzykawki i bezpieczne zastosowanie kliniczne.<\/p><h3>Si\u0142a dzia\u0142ania t\u0142oka<\/h3><p data-start=\"1269\" data-end=\"1702\">Norma ISO 7886-1 zaleca weryfikacj\u0119 si\u0142 wymaganych do zainicjowania i podtrzymania ruchu t\u0142oka, poniewa\u017c od tego zale\u017cy u\u017cyteczno\u015b\u0107 strzykawki i kontrola dawki. <em data-start=\"1457\" data-end=\"1466\">Za\u0142\u0105cznik E<\/em> przedstawia metod\u0119 pomiaru <strong data-start=\"1500\" data-end=\"1532\">si\u0142y zrywaj\u0105ce i \u015blizgowe<\/strong> przy u\u017cyciu mechanicznego systemu testowania. Chocia\u017c test ten ma charakter informacyjny, a nie obowi\u0105zkowy, odgrywa kluczow\u0105 rol\u0119 w zapewnieniu sp\u00f3jnej i przyjaznej dla u\u017cytkownika wydajno\u015bci.<\/p><h3>Dopasowanie i retencja t\u0142oka<\/h3><p>Zatyczka t\u0142oka musi dobrze przylega\u0107 do cylindra. Aby to potwierdzi\u0107, strzykawka jest nape\u0142niana do nominalnej pojemno\u015bci i trzymana pionowo - zar\u00f3wno w pozycji pionowej, jak i odwr\u00f3conej. W ka\u017cdej z tych pozycji t\u0142ok powinien <strong data-start=\"1945\" data-end=\"1979\">nie porusza si\u0119 z powodu w\u0142asnej wagi<\/strong> lub ci\u0119\u017car samej wody. Wym\u00f3g ten zabezpiecza przed niezamierzonym ruchem, kt\u00f3ry m\u00f3g\u0142by spowodowa\u0107 b\u0142\u0119dy dozowania lub wyciek.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f56e8f6 e-flex e-con-boxed e-con e-parent\" data-id=\"f56e8f6\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2f8a27b elementor-widget elementor-widget-heading\" data-id=\"2f8a27b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testowanie funkcjonalno\u015bci strzykawek: Kluczowe parametry i metody testowania<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5563edc e-con-full e-flex e-con e-child\" data-id=\"5563edc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-3c81440 e-con-full e-flex e-con e-child\" data-id=\"3c81440\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dcd03b3 elementor-widget elementor-widget-text-editor\" data-id=\"dcd03b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Testowanie si\u0142y zrywania i po\u015blizgu<\/h3><p data-start=\"1844\" data-end=\"2038\"><strong data-start=\"1844\" data-end=\"1855\">Za\u0142\u0105cznik E<\/strong> normy ISO 7886-1 okre\u015bla metod\u0119 okre\u015blania <em data-start=\"1911\" data-end=\"1924\">wyrwa\u0107 si\u0119<\/em> oraz <em data-start=\"1929\" data-end=\"1942\">si\u0142a po\u015blizgu<\/em> wymagane do obs\u0142ugi t\u0142oka. Si\u0142y te wp\u0142ywaj\u0105 na wra\u017cenia u\u017cytkownika i kontrol\u0119 dawkowania.<\/p><ul><li data-start=\"2042\" data-end=\"2112\"><a href=\"https:\/\/www.syringetest.com\/pl\/break-loose-and-glide-force-testing\/\"><strong data-start=\"2042\" data-end=\"2063\">Si\u0142a zrywaj\u0105ca<\/strong><\/a> to pocz\u0105tkowa si\u0142a potrzebna do poruszenia t\u0142oka.<\/li><li data-start=\"2115\" data-end=\"2188\"><a href=\"https:\/\/www.syringetest.com\/pl\/break-loose-and-glide-force-testing\/\"><strong data-start=\"2115\" data-end=\"2130\">Si\u0142a po\u015blizgu<\/strong><\/a> to \u015brednia si\u0142a wymagana do kontynuowania ruchu t\u0142oka.<\/li><\/ul><p data-start=\"2190\" data-end=\"2217\"><strong data-start=\"2190\" data-end=\"2217\">Najwa\u017cniejsze cechy metody testowej:<\/strong><\/p><ul><li data-start=\"2220\" data-end=\"2329\">U\u017cyj mechanicznego systemu testowania (np. Cell Instruments' <strong data-start=\"2277\" data-end=\"2309\">Tester strzykawek medycznych MST-01<\/strong>) z pr\u0119dko\u015bci\u0105 100 \u00b1 5 mm\/min.<\/li><li data-start=\"2332\" data-end=\"2369\">Nape\u0142ni\u0107 strzykawk\u0119 wod\u0105 o temperaturze 23 \u00b1 5 \u00b0C.<\/li><li data-start=\"2372\" data-end=\"2457\">Pod\u0142\u0105cz strzykawk\u0119 do rurki i wypu\u015b\u0107 wod\u0119, a\u017c t\u0142ok osi\u0105gnie znak nominalny.<\/li><li data-start=\"2460\" data-end=\"2467\">Rekord:<ul><li data-start=\"2472\" data-end=\"2499\">Pocz\u0105tkowa si\u0142a ruchu (f\u209b)<\/li><li data-start=\"2504\" data-end=\"2525\">\u015arednia si\u0142a przesuwu (F)<\/li><li data-start=\"2530\" data-end=\"2558\">Szczytowa si\u0142a oporu (Fmax)<\/li><\/ul><\/li><\/ul><p data-start=\"2560\" data-end=\"2677\"><em data-start=\"2560\" data-end=\"2677\">Sta\u0142y po\u015blizg zapewnia p\u0142ynno\u015b\u0107 wtrysku i komfort u\u017cytkownika, co czyni go kluczowym wyznacznikiem jako\u015bci.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e0368a elementor-widget elementor-widget-image\" data-id=\"8e0368a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"546\" height=\"719\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\" class=\"attachment-large size-large wp-image-613\" alt=\"ISO 7886-1 Za\u0142\u0105cznik E\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp 546w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E-228x300.webp 228w\" sizes=\"(max-width: 546px) 100vw, 546px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e0724ff elementor-widget elementor-widget-text-editor\" data-id=\"e0724ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Wykrywanie wycieku cieczy ze strzykawki (pod ci\u015bnieniem)<\/h3><p data-start=\"2741\" data-end=\"2896\"><strong data-start=\"2741\" data-end=\"2752\">Za\u0142\u0105cznik D<\/strong> przedstawia metod\u0119 wykrywania <a href=\"https:\/\/www.syringetest.com\/pl\/syringe-liquid-leakage-test-for-closure-system\/\"><strong data-start=\"2781\" data-end=\"2799\">wyciek cieczy<\/strong><\/a> przesz\u0142o\u015b\u0107 <strong data-start=\"2809\" data-end=\"2833\">uszczelka korka t\u0142oka<\/strong> podczas kompresji - kluczowy wska\u017anik niezawodno\u015bci strzykawki.<\/p><p data-start=\"2898\" data-end=\"2915\"><strong data-start=\"2898\" data-end=\"2915\">Proces testowy:<\/strong><\/p><ul><li data-start=\"2918\" data-end=\"2985\">Nape\u0142ni\u0107 strzykawk\u0119 do nominalnej obj\u0119to\u015bci wod\u0105 destylowan\u0105 (18-28 \u00b0C).<\/li><li data-start=\"2988\" data-end=\"3049\">Uszczelni\u0107 dysz\u0119 strzykawki za pomoc\u0105 z\u0142\u0105czek zgodnych z norm\u0105 ISO 80369-7.<\/li><li data-start=\"3052\" data-end=\"3098\">Przy\u0142o\u017cy\u0107 si\u0142\u0119 boczn\u0105 (0,25-3 N) do t\u0142oka.<\/li><li data-start=\"3101\" data-end=\"3163\">Zastosuj si\u0142\u0119 osiow\u0105, aby wytworzy\u0107 ci\u015bnienie wewn\u0119trzne (200-300 kPa).<\/li><li data-start=\"3166\" data-end=\"3193\">Utrzyma\u0107 przez 30-35 sekund.<\/li><li data-start=\"3196\" data-end=\"3238\">Sprawdzi\u0107, czy z cylindra nie wycieka p\u0142yn.<\/li><\/ul><p data-start=\"3240\" data-end=\"3361\">Cell Instruments oferuje <strong data-start=\"3268\" data-end=\"3298\">Tester szczelno\u015bci strzykawek SLT-02<\/strong>idealny do precyzyjnej kontroli ci\u015bnienia i obserwacji w czasie rzeczywistym.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2bd0256 e-con-full e-flex e-con e-child\" data-id=\"2bd0256\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bc3f908 elementor-widget elementor-widget-text-editor\" data-id=\"bc3f908\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Wykrywanie wycieku powietrza ze strzykawki (podczas aspiracji)<\/h3><p data-start=\"3422\" data-end=\"3549\"><strong data-start=\"3422\" data-end=\"3433\">Za\u0142\u0105cznik B<\/strong> okre\u015bla procedury dla <strong data-start=\"3457\" data-end=\"3490\">wykrywanie wycieku powietrza ze strzykawki<\/strong> i weryfikacja zatrzymania korka t\u0142oka podczas zasysania.<\/p><p data-start=\"3551\" data-end=\"3565\"><strong data-start=\"3551\" data-end=\"3565\">Procedura:<\/strong><\/p><ul><li data-start=\"3568\" data-end=\"3635\">Cz\u0119\u015bciowo nape\u0142ni\u0107 strzykawk\u0119 wod\u0105 i poci\u0105gn\u0105\u0107 t\u0142ok do oznaczenia nominalnego.<\/li><li data-start=\"3638\" data-end=\"3690\">Zabezpieczy\u0107 t\u0142ok i pod\u0142\u0105czy\u0107 strzykawk\u0119 do systemu pr\u00f3\u017cniowego.<\/li><li data-start=\"3693\" data-end=\"3736\">Wytworzy\u0107 ci\u015bnienie 88 kPa poni\u017cej ci\u015bnienia atmosferycznego.<\/li><li data-start=\"3739\" data-end=\"3762\">Obserwowa\u0107 przez 60 sekund:<ul><li data-start=\"3767\" data-end=\"3810\">Spadek ci\u015bnienia manometru (wskazuje wyciek)<\/li><li data-start=\"3815\" data-end=\"3848\">Od\u0142\u0105czenie lub niestabilno\u015b\u0107 t\u0142oka<\/li><\/ul><\/li><\/ul><p data-start=\"3850\" data-end=\"3955\">Szczelno\u015b\u0107 zapewnia dok\u0142adno\u015b\u0107 dozowania i zapobiega zanieczyszczeniom, dzi\u0119ki czemu test ten jest niezb\u0119dny do bezpiecznego u\u017cytkowania.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a0b40de elementor-widget elementor-widget-image\" data-id=\"a0b40de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"694\" height=\"570\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B.webp\" class=\"attachment-large size-large wp-image-614\" alt=\"ISO 7886-1 Za\u0142\u0105cznik B\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B.webp 694w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B-300x246.webp 300w\" sizes=\"(max-width: 694px) 100vw, 694px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a4c9f2a e-flex e-con-boxed e-con e-parent\" data-id=\"a4c9f2a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-032dedc elementor-widget elementor-widget-heading\" data-id=\"032dedc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wyb\u00f3r odpowiedniego sprz\u0119tu do testowania strzykawek<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-02a9ca0 e-grid e-con-full e-con e-child\" data-id=\"02a9ca0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8858447 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"8858447\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img decoding=\"async\" width=\"1698\" height=\"2560\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp\" class=\"attachment-full size-full wp-image-884\" alt=\"SLT-02 Tester szczelno\u015bci strzykawki\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp 1698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-199x300.webp 199w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-679x1024.webp 679w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-768x1158.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1019x1536.webp 1019w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1358x2048.webp 1358w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-8x12.webp 8w\" sizes=\"(max-width: 1698px) 100vw, 1698px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">Tester szczelno\u015bci strzykawek SLT-02<\/h3><p class=\"elementor-image-box-description\">Przyrz\u0105d ten precyzyjnie przyk\u0142ada kontrolowan\u0105 pr\u00f3\u017cni\u0119 do strzykawki, umo\u017cliwiaj\u0105c dok\u0142adne monitorowanie zmian ci\u015bnienia i integralno\u015bci t\u0142oka. Zaprojektowany z po\u0142\u0105czeniami zgodnymi z ISO 80369-7 i bezpiecznymi mechanizmami zaciskowymi, SLT-01 zapewnia dok\u0142adn\u0105 ocen\u0119 zar\u00f3wno szczelno\u015bci, jak i zatrzymania t\u0142oka.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84ddc7f elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"84ddc7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img loading=\"lazy\" decoding=\"async\" width=\"1285\" height=\"2560\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-scaled.webp\" class=\"attachment-full size-full wp-image-889\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-scaled.webp 1285w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-151x300.webp 151w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-514x1024.webp 514w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-768x1530.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-771x1536.webp 771w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-1028x2048.webp 1028w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-6x12.webp 6w\" sizes=\"(max-width: 1285px) 100vw, 1285px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">Tester strzykawek medycznych MST-01<\/h3><p class=\"elementor-image-box-description\">Wykorzystuje on wysoce precyzyjny system mechaniczny do pomiaru si\u0142 zrywaj\u0105cych i \u015blizgowych podczas wypychania p\u0142ynu. MST-01 umo\u017cliwia producentom ilo\u015bciowe okre\u015blenie oporu inicjacji i przesuwu, dostarczaj\u0105c istotnych danych w celu zapewnienia p\u0142ynnego i sp\u00f3jnego ruchu t\u0142oka - kluczowego dla bezpiecze\u0144stwa i komfortu.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bda0648 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"bda0648\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img loading=\"lazy\" decoding=\"async\" width=\"1164\" height=\"2560\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-scaled.webp\" class=\"attachment-full size-full wp-image-885\" alt=\"SPPT-01 Tester szczelno\u015bci nadci\u015bnieniowej strzykawki\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-scaled.webp 1164w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-136x300.webp 136w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-465x1024.webp 465w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-768x1690.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-698x1536.webp 698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-931x2048.webp 931w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-5x12.webp 5w\" sizes=\"(max-width: 1164px) 100vw, 1164px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">SPPT-01 Tester szczelno\u015bci strzykawek<\/h3><p class=\"elementor-image-box-description\">Urz\u0105dzenie to symuluje ci\u015bnienie wewn\u0105trz cylindra strzykawki, jednocze\u015bnie przyk\u0142adaj\u0105c obci\u0105\u017cenia boczne i osiowe do t\u0142oka, \u015bci\u015ble replikuj\u0105c warunki u\u017cytkowania klinicznego. SSPT-01 zosta\u0142 zaprojektowany do wykrywania nawet subtelnych uszkodze\u0144 uszczelnienia, pomagaj\u0105c producentom zweryfikowa\u0107 niezawodno\u015b\u0107 produktu i zgodno\u015b\u0107 z rygorystycznymi normami bezpiecze\u0144stwa.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8b0f6e0 e-flex e-con-boxed e-con e-parent\" data-id=\"8b0f6e0\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11b99fc elementor-widget elementor-widget-heading\" data-id=\"11b99fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Dlaczego zgodno\u015b\u0107 z norm\u0105 ISO 7886-1 ma znaczenie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-263368c elementor-widget elementor-widget-text-editor\" data-id=\"263368c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4571\" data-end=\"4657\">Zgodno\u015b\u0107 z norm\u0105 ISO 7886-1 gwarantuje, \u017ce strzykawki:<\/p><ul><li data-start=\"4660\" data-end=\"4682\">Dostarczanie dok\u0142adnych dawek<\/li><li data-start=\"4685\" data-end=\"4713\">S\u0105 bezpieczne i \u0142atwe w obs\u0142udze<\/li><li data-start=\"4716\" data-end=\"4740\">Pozostaj\u0105 szczelne podczas u\u017cytkowania<\/li><li data-start=\"4743\" data-end=\"4789\">Spe\u0142nianie globalnych wymog\u00f3w regulacyjnych i eksportowych<\/li><\/ul><p data-start=\"4791\" data-end=\"4910\">Zaniedbanie w\u0142a\u015bciwego <strong data-start=\"4809\" data-end=\"4842\">Testowanie funkcjonalno\u015bci strzykawki<\/strong> mo\u017ce prowadzi\u0107 do wycofania produktu z rynku, kar regulacyjnych lub szk\u00f3d dla pacjent\u00f3w.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-be52d1e e-grid e-con-full e-con e-parent\" data-id=\"be52d1e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c72d800 elementor-widget elementor-widget-image\" data-id=\"c72d800\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c83f8a8 e-con-full e-flex e-con e-child\" data-id=\"c83f8a8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09b28d1 elementor-widget elementor-widget-heading\" data-id=\"09b28d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Dlaczego warto wybra\u0107 <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c87e7b1 elementor-widget elementor-widget-text-editor\" data-id=\"c87e7b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4917\" data-end=\"5240\">Zrozumienie i zastosowanie <strong data-start=\"4961\" data-end=\"4975\">ISO 7886-1<\/strong> Metody testowania s\u0105 niezb\u0119dne dla ka\u017cdej firmy zajmuj\u0105cej si\u0119 produkcj\u0105 strzykawek lub kontrol\u0105 jako\u015bci. Od <strong data-start=\"5077\" data-end=\"5116\">Testowanie luzu i si\u0142y po\u015blizgu<\/strong> do <strong data-start=\"5120\" data-end=\"5153\">wykrywanie wyciek\u00f3w powietrza i cieczy<\/strong>Ka\u017cdy test pe\u0142ni okre\u015blon\u0105 rol\u0119 w zapewnieniu niezawodno\u015bci produktu i bezpiecze\u0144stwa u\u017cytkownika.<\/p><p data-start=\"5242\" data-end=\"5537\"><strong>Syringetest.com<\/strong> zapewnia zaawansowane <strong data-start=\"5281\" data-end=\"5310\">sprz\u0119t do testowania strzykawek<\/strong> zaprojektowane w celu zapewnienia pe\u0142nej zgodno\u015bci i usprawnienia proces\u00f3w kontroli jako\u015bci. Je\u015bli chcesz ulepszy\u0107 proces walidacji strzykawek lub poprawi\u0107 dok\u0142adno\u015b\u0107 test\u00f3w, skontaktuj si\u0119 z nami, aby dowiedzie\u0107 si\u0119, w jaki spos\u00f3b nasze urz\u0105dzenia mog\u0105 pom\u00f3c w spe\u0142nieniu Twoich standard\u00f3w.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6924b06 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"6924b06\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/pl\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 7886-1 Syringe Functionality Testing Standard ISO 7886-1 is the internationally recognized standard that defines the performance and testing requirements for sterile hypodermic syringes for single use, intended for manual operation. This standard plays a vital role in syringe quality control, ensuring functional safety and patient protection. Quality control engineers and regulatory specialists rely on [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":603,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-608","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages\/608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/comments?post=608"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages\/608\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages\/603"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/media?parent=608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}