{"id":288,"date":"2025-05-06T06:58:13","date_gmt":"2025-05-06T06:58:13","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=288"},"modified":"2026-05-09T06:47:27","modified_gmt":"2026-05-09T06:47:27","slug":"luer-lock-rigid-tip-cap-unscrewing-torque","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/pl\/luer-lock-rigid-tip-cap-unscrewing-torque","title":{"rendered":"Moment odkr\u0119cania sztywnej nasadki Luer Lock"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"288\" class=\"elementor elementor-288\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ff288b4 e-flex e-con-boxed e-con e-parent\" data-id=\"ff288b4\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-49f41f0 elementor-widget elementor-widget-heading\" data-id=\"49f41f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Moment odkr\u0119cania sztywnej nasadki Luer Lock<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b1aaa54 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"b1aaa54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>W dziedzinie produkcji urz\u0105dze\u0144 medycznych <strong>Moment odkr\u0119cania sztywnej nasadki luer lock<\/strong> odgrywa istotn\u0105 rol\u0119 w weryfikacji u\u017cyteczno\u015bci i bezpiecze\u0144stwa wst\u0119pnie nape\u0142nionych strzykawek. Ten krytyczny test zapewnia, \u017ce sztywna nasadka ko\u0144c\u00f3wki mo\u017ce by\u0107 usuni\u0119ta z odpowiednim momentem obrotowym, chroni\u0105c zar\u00f3wno funkcjonalno\u015b\u0107, jak i bezpiecze\u0144stwo pacjenta. Dok\u0142adne testowanie ma zasadnicze znaczenie dla zgodno\u015bci z mi\u0119dzynarodowymi normami i utrzymania wysokiej jako\u015bci standard\u00f3w produkcji oczekiwanych w bran\u017cy medycznej.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-58bdb3e e-flex e-con-boxed e-con e-parent\" data-id=\"58bdb3e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-659fb04 elementor-widget elementor-widget-heading\" data-id=\"659fb04\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Znaczenie testowania sztywnych nasadek Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f56c4d elementor-widget elementor-widget-text-editor\" data-id=\"8f56c4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Prawid\u0142owe wykonanie tego testu zapewnia:<\/p><ul><li><strong>Bezpiecze\u0144stwo pacjent\u00f3w<\/strong>: Zapewnienie, \u017ce nasadki nie s\u0105 ani zbyt ciasne, ani zbyt lu\u017ane, chroni pacjent\u00f3w przed zanieczyszczeniem lub problemami z u\u017cytkowaniem.<\/li><li><strong>Zgodno\u015b\u0107 z przepisami<\/strong>: Spe\u0142nienie norm ISO 11040-4 ma kluczowe znaczenie dla dost\u0119pu do rynku i akceptacji produktu.<\/li><li><strong>Sp\u00f3jno\u015b\u0107 produktu<\/strong>: Testowanie wspiera sp\u00f3jne procesy produkcyjne, zmniejszaj\u0105c liczb\u0119 defekt\u00f3w i zapewniaj\u0105c niezawodno\u015b\u0107 partii.<\/li><\/ul><p>Do\u015bwiadczenie Syringetest.com w zakresie testowania materia\u0142\u00f3w i niestandardowych rozwi\u0105za\u0144 zapewnia, \u017ce producenci strzykawek mog\u0105 skutecznie spe\u0142nia\u0107 te rygorystyczne wymagania testowe, poprawiaj\u0105c jako\u015b\u0107 produktu i konkurencyjno\u015b\u0107 na rynku.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-de73fea e-flex e-con-boxed e-con e-parent\" data-id=\"de73fea\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e6ff1ae elementor-widget elementor-widget-heading\" data-id=\"e6ff1ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 i ISO 11040-4 Za\u0142\u0105cznik G5 Wymagania<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-308b5c9 e-con-full e-flex e-con e-child\" data-id=\"308b5c9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5d88b36 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"5d88b36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.syringetest.com\/pl\/standards\/iso-11040-4\/\">ISO 11040-4<\/a> i jego za\u0142\u0105cznik G5 okre\u015blaj\u0105 szczeg\u00f3\u0142owe procedury i wymagania dotycz\u0105ce aparatury do oceny <strong>Moment odkr\u0119cania sztywnej nasadki luer lock<\/strong>. Wytyczne te zapewniaj\u0105 sp\u00f3jne i wiarygodne testy w ca\u0142ej bran\u017cy.<\/p><p>Wed\u0142ug <strong>ISO 11040-4 Za\u0142\u0105cznik G5<\/strong>Celem tego testu jest ocena momentu obrotowego potrzebnego do odkr\u0119cenia sztywnej nasadki ze sterylizowanych, gotowych do nape\u0142nienia podzespo\u0142\u00f3w strzykawek. Celem jest sprawdzenie, czy moment odkr\u0119cania nasadki mie\u015bci si\u0119 w dopuszczalnych granicach, ani zbyt wysokich (co mog\u0142oby utrudni\u0107 u\u017cytkowanie), ani zbyt niskich (co mog\u0142oby zagrozi\u0107 sterylno\u015bci).<\/p><p>Za\u0142\u0105cznik okre\u015bla potrzeb\u0119:<\/p><ul><li>A <strong>tester momentu obrotowego<\/strong> wyposa\u017cony w urz\u0105dzenie obrotowe.<\/li><li>A <strong>ogniwo dynamometryczne<\/strong> o wydajno\u015bci 35 Ncm i rozdzielczo\u015bci 0,05 Ncm lub lepszej.<\/li><li>A <strong>pr\u0119dko\u015b\u0107 obrotowa<\/strong> 20 obrot\u00f3w na minut\u0119 (rpm), regulowana na podstawie porozumienia mi\u0119dzy producentem a klientem.<\/li><li>Specjalistyczne urz\u0105dzenia, takie jak <strong>chwytak nasadki ko\u0144c\u00f3wki<\/strong> oraz <strong>uchwyt strzykawki<\/strong>.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a858e71 elementor-widget elementor-widget-image\" data-id=\"a858e71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"320\" height=\"410\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp\" class=\"attachment-large size-large wp-image-290\" alt=\"Si\u0142a odrywania nasadki ko\u0144c\u00f3wki lub os\u0142ony ig\u0142y - ISO 11040-4, za\u0142\u0105cznik G5\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp 320w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5-234x300.webp 234w\" sizes=\"(max-width: 320px) 100vw, 320px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b28ec18 e-flex e-con-boxed e-con e-parent\" data-id=\"b28ec18\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-197dd31 elementor-widget elementor-widget-heading\" data-id=\"197dd31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procedura testowa momentu odkr\u0119cania sztywnej nasadki Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b15e179 elementor-widget elementor-widget-text-editor\" data-id=\"b15e179\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wykonywanie <strong>Moment odkr\u0119cania sztywnej nasadki luer lock<\/strong> Test obejmuje kilka precyzyjnych krok\u00f3w:<\/p><h3>Przygotowanie pr\u00f3bki<\/h3><p>Wybierz wysterylizowane strzykawki, kt\u00f3re pasuj\u0105 do procesu produkcyjnego. Prawid\u0142owa obs\u0142uga pr\u00f3bek zapewnia, \u017ce wyniki dok\u0142adnie odzwierciedlaj\u0105 jako\u015b\u0107 produkcji.<\/p><h3>Konfiguracja urz\u0105dzenia<\/h3><ul><li>Zamocuj strzykawk\u0119 pionowo w uchwycie <strong>uchwyt strzykawki<\/strong> urz\u0105dzenia testuj\u0105cego.<\/li><li>Do\u0142\u0105cz <strong>adapter<\/strong> (chwytak nasadki ko\u0144c\u00f3wki) na nasadce ko\u0144c\u00f3wki bez stosowania wst\u0119pnego momentu dokr\u0119cania.<\/li><li>Ustaw kom\u00f3rk\u0119 momentu obrotowego na \"zero\", aby zapewni\u0107 podstawow\u0105 dok\u0142adno\u015b\u0107.<\/li><li>Ustawi\u0107 urz\u0105dzenie obrotowe na 20 obr.<\/li><\/ul><h3>Procedura testowania<\/h3><ul><li>Zainicjuj obr\u00f3t zgodnie lub przeciwnie do ruchu wskaz\u00f3wek zegara, w zale\u017cno\u015bci od wymaga\u0144 systemu.<\/li><li>Utrzymuj sta\u0142y obr\u00f3t, a\u017c nasadka ko\u0144c\u00f3wki zacznie si\u0119 odkr\u0119ca\u0107.<\/li><li>Zapisz <strong>szczytowy moment obrotowy<\/strong> w momencie, gdy nasadka zaczyna si\u0119 porusza\u0107.<\/li><\/ul><p>Niezb\u0119dne jest zapewnienie <strong>Wysoka cz\u0119stotliwo\u015b\u0107 pr\u00f3bkowania<\/strong> podczas test\u00f3w. Za\u0142\u0105cznik G5 zaleca cz\u0119stotliwo\u015b\u0107 pr\u00f3bkowania 500 Hz dla test\u00f3w, kt\u00f3re wymagaj\u0105 pomiar\u00f3w szczytowego momentu obrotowego, zwi\u0119kszaj\u0105c dok\u0142adno\u015b\u0107 danych.<\/p><h3>Wyra\u017canie wynik\u00f3w<\/h3><p>Po zako\u0144czeniu testu nale\u017cy udokumentowa\u0107 nast\u0119puj\u0105ce informacje:<\/p><ul><li>Maksymalny osi\u0105gni\u0119ty moment obrotowy (w Ncm).<\/li><li>Pr\u0119dko\u015b\u0107 obrotowa u\u017cywana podczas test\u00f3w.<\/li><li>Liczba przetestowanych pr\u00f3bek oraz liczba pr\u00f3bek, kt\u00f3re przesz\u0142y lub nie przesz\u0142y testu zgodnie ze specyfikacj\u0105.<\/li><li>Wszelkie odchylenia, anomalie lub obserwacje odnotowane podczas test\u00f3w.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9ee2543 e-grid e-con-full e-con e-parent\" data-id=\"9ee2543\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-896974c elementor-widget elementor-widget-image\" data-id=\"896974c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-49cfbb3 e-con-full e-flex e-con e-child\" data-id=\"49cfbb3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1acd247 elementor-widget elementor-widget-heading\" data-id=\"1acd247\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Dlaczego warto wybra\u0107 <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2c455c elementor-widget elementor-widget-text-editor\" data-id=\"f2c455c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"203\" data-end=\"463\">Przy <strong>Syringetest.com<\/strong>\u0141\u0105czymy wiedz\u0119 specjalistyczn\u0105, innowacje, od precyzyjnej in\u017cynierii po spersonalizowan\u0105 obs\u0142ug\u0119, aby wspiera\u0107 naszych klient\u00f3w na ca\u0142ym \u015bwiecie.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5784c2f elementor-widget elementor-widget-text-editor\" data-id=\"5784c2f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong>Moment odkr\u0119cania sztywnej nasadki luer lock<\/strong> test, zgodnie z definicj\u0105 <strong>ISO 11040-4 Za\u0142\u0105cznik G5<\/strong>jest niezb\u0119dna do utrzymania jako\u015bci strzykawek i zapewnienia zgodno\u015bci z globalnymi standardami. Dzi\u0119ki odpowiedniemu sprz\u0119towi i prawid\u0142owym procedurom testowym producenci mog\u0105 z pewno\u015bci\u0105 zweryfikowa\u0107 u\u017cyteczno\u015b\u0107 swoich strzykawek. Zaufaj firmie Syringetest.com, kt\u00f3ra dostarcza precyzyjne rozwi\u0105zania testowe dostosowane do Twoich potrzeb, pomagaj\u0105c Ci utrzyma\u0107 najwy\u017csze standardy bezpiecze\u0144stwa i jako\u015bci.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ecae3d1 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"ecae3d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/pl\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Rigid Tip Cap Unscrewing Torque In the field of medical device manufacturing, the luer lock rigid tip cap unscrewing torque test plays a vital role in verifying the usability and safety of prefilled syringes. This critical test ensures that the rigid tip cap can be removed with appropriate torque, safeguarding both functionality and [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-288","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages\/288","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/comments?post=288"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages\/288\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/media?parent=288"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}