{"id":154,"date":"2025-04-30T01:31:34","date_gmt":"2025-04-30T01:31:34","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=154"},"modified":"2026-05-09T06:36:31","modified_gmt":"2026-05-09T06:36:31","slug":"finger-flange-breakage-force-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/pl\/finger-flange-breakage-force-test","title":{"rendered":"Test si\u0142y zerwania ko\u0142nierza palca"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"154\" class=\"elementor elementor-154\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-247db7c e-flex e-con-boxed e-con e-parent\" data-id=\"247db7c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab06118 elementor-widget elementor-widget-heading\" data-id=\"ab06118\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Test si\u0142y zerwania ko\u0142nierza palca<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62cf733 elementor-widget elementor-widget-text-editor\" data-id=\"62cf733\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>W bran\u017cy opakowa\u0144 farmaceutycznych i medycznych, <strong>Si\u0142a zrywaj\u0105ca ko\u0142nierz palca<\/strong> jest krytycznym wska\u017anikiem wydajno\u015bci zapewniaj\u0105cym niezawodno\u015b\u0107 strukturaln\u0105 beczek strzykawek. Parametr ten, zdefiniowany i znormalizowany w <strong><em><a href=\"https:\/\/www.syringetest.com\/pl\/standards\/iso-11040-4\/\">ISO 11040-4<\/a> Za\u0142\u0105cznik C1<\/em><\/strong>pomaga producentom i specjalistom ds. zapewnienia jako\u015bci oceni\u0107, czy ko\u0142nierz strzykawki mo\u017ce wytrzyma\u0107 napr\u0119\u017cenia mechaniczne podczas obs\u0142ugi i wstrzykiwania.<\/p><p>Zrozumienie tego pomiaru i jego standardowej metody testowania jest kluczowe dla profesjonalist\u00f3w zaanga\u017cowanych w <strong>testowanie strzykawek<\/strong>, zw\u0142aszcza w przypadku sterylnych strzykawek przeznaczonych do roztwor\u00f3w do wstrzykiwania.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f136d2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f136d2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b673494 elementor-widget elementor-widget-heading\" data-id=\"b673494\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Znaczenie si\u0142y z\u0142amania ko\u0142nierza palca dla integralno\u015bci strzykawki<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa819a0 elementor-widget elementor-widget-text-editor\" data-id=\"aa819a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong>Si\u0142a zrywaj\u0105ca ko\u0142nierz palca<\/strong> odnosi si\u0119 do maksymalnej si\u0142y mechanicznej, jak\u0105 ko\u0142nierz strzykawki mo\u017ce wytrzyma\u0107 przed uszkodzeniem. Warto\u015b\u0107 ta wskazuje na wytrzyma\u0142o\u015b\u0107 strzykawki, zw\u0142aszcza gdy u\u017cytkownicy wywieraj\u0105 nacisk podczas wstrzykiwania lub gdy zautomatyzowane systemy nape\u0142niania chwytaj\u0105 strzykawk\u0119.<\/p><p>Niewystarczaj\u0105ca si\u0142a zrywaj\u0105ca mo\u017ce skutkowa\u0107 p\u0119kni\u0119ciami ko\u0142nierza lub ca\u0142kowit\u0105 awari\u0105, stwarzaj\u0105c zagro\u017cenie dla bezpiecze\u0144stwa. Dlatego te\u017c utrzymanie sta\u0142ej jako\u015bci we wszystkich partiach nie podlega negocjacjom w produkcji urz\u0105dze\u0144 medycznych.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-37feff9 e-flex e-con-boxed e-con e-parent\" data-id=\"37feff9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3146496 elementor-widget elementor-widget-heading\" data-id=\"3146496\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test si\u0142y zrywaj\u0105cej ko\u0142nierz palca - ISO 11040-4 Za\u0142\u0105cznik C1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08fc359 elementor-widget elementor-widget-text-editor\" data-id=\"08fc359\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong><a href=\"https:\/\/www.syringetest.com\/pl\/standards\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">ISO 11040-4<\/a> Za\u0142\u0105cznik C1<\/strong> przedstawia metod\u0119 testowania odporno\u015bci ko\u0142nierza na z\u0142amanie. Procedura zapewnia dok\u0142adne, powtarzalne wyniki, co czyni j\u0105 z\u0142otym standardem w testowaniu wydajno\u015bci strzykawek.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd10895 e-grid e-con-full e-con e-child\" data-id=\"fd10895\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d98b842 elementor-widget elementor-widget-text-editor\" data-id=\"d98b842\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Cel testu<\/h3><p>Okre\u015blenie odporno\u015bci ko\u0142nierza na z\u0142amanie poprzez przy\u0142o\u017cenie si\u0142y skierowanej w d\u00f3\u0142 do cylindra strzykawki przy u\u017cyciu specjalistycznego sprz\u0119tu. Ten test ocenia zar\u00f3wno <strong>wytrzyma\u0142o\u015b\u0107 szklanej beczki<\/strong> i jego kompatybilno\u015b\u0107 z reszt\u0105 konstrukcji strzykawki.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db58dbc elementor-widget elementor-widget-text-editor\" data-id=\"db58dbc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Wymagany sprz\u0119t<\/h3><ul><li><strong>Uniwersalna maszyna do pr\u00f3b rozci\u0105gania i \u015bciskania<\/strong>: Musi zawiera\u0107 odpowiedni czujnik wagowy i konfigurowaln\u0105 pr\u0119dko\u015b\u0107 testow\u0105 wynosz\u0105c\u0105 <strong>100 mm\/min<\/strong>.<\/li><li><strong>Uchwyt strzykawki<\/strong>: Zazwyczaj wykonane z PEEK, dostosowane do wymiar\u00f3w strzykawki.<\/li><li><strong>Sworze\u0144 \u0142aduj\u0105cy<\/strong>: Wykonane z poliacetalu lub stali nierdzewnej, zaprojektowane do r\u00f3wnomiernego przyk\u0142adania si\u0142y.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a8c15d0 elementor-widget elementor-widget-image\" data-id=\"a8c15d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"202\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-1024x258.webp\" class=\"attachment-large size-large wp-image-163\" alt=\"Test si\u0142y z\u0142amania ko\u0142nierza strzykawki - ISO 11040-4, za\u0142\u0105cznik C1\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-1024x258.webp 1024w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-300x76.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-768x194.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1.webp 1190w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a78210 e-flex e-con-boxed e-con e-parent\" data-id=\"3a78210\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e89a55d elementor-widget elementor-widget-heading\" data-id=\"e89a55d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Konfiguracja i wykonanie test\u00f3w strzykawkowych<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e8f3f2 elementor-widget elementor-widget-text-editor\" data-id=\"2e8f3f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Aby wykona\u0107 test zgodnie z opisem <strong>Testy ISO 11040-4<\/strong>, wykonaj nast\u0119puj\u0105ce kroki:<\/p><h3>1. Przygotowanie pr\u00f3bki<\/h3><p>Nale\u017cy unika\u0107 wstrz\u0105s\u00f3w lub niew\u0142a\u015bciwego obchodzenia si\u0119 ze strzykawkami przed testowaniem. Sprawdzi\u0107 uchwyt i sworze\u0144 pod k\u0105tem zu\u017cycia.<\/p><h3>2. Konfiguracja sprz\u0119tu<\/h3><ul><li>Umie\u015b\u0107 strzykawk\u0119 w uchwycie pod ko\u0142nierzem.<\/li><li>Ustaw trzpie\u0144 \u0142aduj\u0105cy tak, aby przy\u0142o\u017cy\u0107 si\u0142\u0119 na g\u0142\u0119boko\u015bci ko\u0142nierza lufy.<\/li><\/ul><h3>3. Wykonanie testu<\/h3><ul><li>Uruchom urz\u0105dzenie z pr\u0119dko\u015bci\u0105 <strong>100 mm\/min<\/strong>.<\/li><li>Zapisz wykres si\u0142a-przemieszczenie.<\/li><li>U\u017cyj <strong>cz\u0119stotliwo\u015b\u0107 pr\u00f3bkowania co najmniej 500 Hz<\/strong> do wykrywania si\u0142y szczytowej.<\/li><\/ul><h3>4. Analiza wynik\u00f3w<\/h3><p>Si\u0142a szczytowa zaobserwowana przed uszkodzeniem ko\u0142nierza jest rejestrowana jako <strong>Si\u0142a zrywaj\u0105ca ko\u0142nierz palca<\/strong>. ISO 11040-4 Za\u0142\u0105cznik C1 okre\u015bla, \u017ce warto\u015b\u0107 ta, wraz z pr\u0119dko\u015bci\u0105 testu i liczb\u0105 pr\u00f3bek, powinna by\u0107 podana w dokumentacji ko\u0144cowej.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2d148ee e-grid e-con-full e-con e-parent\" data-id=\"2d148ee\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef5e9b3 elementor-widget elementor-widget-image\" data-id=\"ef5e9b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f83c119 e-con-full e-flex e-con e-child\" data-id=\"f83c119\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-af86f15 elementor-widget elementor-widget-heading\" data-id=\"af86f15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Dlaczego warto wybra\u0107 <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-321653d elementor-widget elementor-widget-text-editor\" data-id=\"321653d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dok\u0142adne testowanie si\u0142y zrywaj\u0105cej ko\u0142nierz wymaga zastosowania wysokowydajnych przyrz\u0105d\u00f3w. Przy <strong>Syringetest.com<\/strong>Oferujemy zaawansowane testery rozci\u0105gania i \u015bciskania dostosowane do potrzeb <strong>testowanie strzykawek<\/strong>w pe\u0142ni zgodny z <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><em>ISO 11040-4<\/em><\/a>. Nasze systemy s\u0105 wyposa\u017cone w precyzyjne czujniki wagowe, regulowane pr\u0119dko\u015bci i intuicyjne oprogramowanie do wizualizacji i eksportu danych w czasie rzeczywistym.<\/p><p>Oferujemy r\u00f3wnie\u017c <strong>Niestandardowe uchwyty na strzykawki i integracja automatyzacji<\/strong>pomagaj\u0105c usprawni\u0107 testowanie w \u015brodowiskach produkcyjnych o wysokiej wydajno\u015bci.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-262c330 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"262c330\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/pl\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Finger Flange Breakage Force Testing In the pharmaceutical and medical packaging industry, finger flange breakage force is a critical performance indicator for ensuring the structural reliability of syringe barrels. This parameter, defined and standardized in ISO 11040-4 Annex C1, helps manufacturers and quality assurance professionals assess whether the syringe flange can withstand mechanical stress during [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-154","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages\/154","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/comments?post=154"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/pages\/154\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/pl\/wp-json\/wp\/v2\/media?parent=154"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}