{"id":743,"date":"2026-01-21T01:54:08","date_gmt":"2026-01-21T01:54:08","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=743"},"modified":"2026-05-19T07:28:56","modified_gmt":"2026-05-19T07:28:56","slug":"iso-9626","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/nb\/standards\/iso-9626","title":{"rendered":"ISO 9626"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"743\" class=\"elementor elementor-743\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f874d59 e-flex e-con-boxed e-con e-parent\" data-id=\"f874d59\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bd174fc elementor-widget elementor-widget-heading\" data-id=\"bd174fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 9626<br><small>Stivhetstest og motstandstesting av n\u00e5leslanger for medisinsk utstyr<\/small><\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e540d6b elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"e540d6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong data-start=\"525\" data-end=\"537\">ISO 9626<\/strong> gir viktige retningslinjer for testing av n\u00e5leslanger i rustfritt st\u00e5l som brukes i medisinsk utstyr, for eksempel injeksjonsn\u00e5ler. Disse testene, inkludert <a href=\"https:\/\/www.syringetest.com\/nb\/needle-tubing-stiffness-test\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"689\" data-end=\"721\">stivhetstest for n\u00e5leslanger<\/strong><\/a> og bruddstyrke, s\u00f8rger for at slangene opprettholder mekanisk integritet under ulike forhold, noe som bidrar til sikkerheten og effektiviteten til medisinsk utstyr. Denne artikkelen forklarer de viktigste aspektene ved <strong data-start=\"933\" data-end=\"945\">ISO 9626<\/strong>, den <strong data-start=\"951\" data-end=\"983\">stivhetstest for n\u00e5leslanger<\/strong>, og relaterte tester som f.eks. <strong data-start=\"1011\" data-end=\"1035\">korrosjonsbestandighet<\/strong> og <strong data-start=\"1040\" data-end=\"1077\">motstand mot brudd p\u00e5 n\u00e5leslanger<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b53c62 e-flex e-con-boxed e-con e-parent\" data-id=\"7b53c62\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a6b3275 elementor-widget elementor-widget-heading\" data-id=\"a6b3275\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Betydningen av ISO 9626 ved testing av n\u00e5leslanger<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9be5caa elementor-widget elementor-widget-text-editor\" data-id=\"9be5caa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1141\" data-end=\"1609\"><strong data-start=\"1141\" data-end=\"1158\">ISO 9626:2016<\/strong> spesifiserer kravene til <strong data-start=\"1190\" data-end=\"1229\">stive n\u00e5leslanger i rustfritt st\u00e5l<\/strong> som brukes i produksjonen av medisinsk utstyr, prim\u00e6rt til bruk p\u00e5 mennesker. Standarden gjelder for slanger i ulike metriske st\u00f8rrelser, fra <strong data-start=\"1367\" data-end=\"1388\">3,4 mm (10 Gauge)<\/strong> til <strong data-start=\"1392\" data-end=\"1414\">0,18 mm (34 Gauge)<\/strong>. Den dekker mekaniske egenskaper som <strong data-start=\"1456\" data-end=\"1483\">stivhet i n\u00e5leslanger<\/strong>, brudd- og korrosjonsbestandighet, noe som er avgj\u00f8rende for \u00e5 garantere sikkerheten og p\u00e5liteligheten til medisinsk utstyr.<\/p><p data-start=\"1611\" data-end=\"1904\">ISO 9626 beskriver testmetodene for \u00e5 bestemme de fysiske egenskapene til n\u00e5leslanger, inkludert <strong data-start=\"1717\" data-end=\"1737\">strekkfasthet<\/strong>, <strong data-start=\"1739\" data-end=\"1752\">stivhet<\/strong>, og <strong data-start=\"1758\" data-end=\"1781\">bruddmotstand<\/strong>. Disse testene er avgj\u00f8rende for at produsentene skal kunne overholde bransjestandardene og levere holdbare produkter av h\u00f8y kvalitet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-358c421 e-flex e-con-boxed e-con e-parent\" data-id=\"358c421\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ebed27b elementor-widget elementor-widget-heading\" data-id=\"ebed27b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Stivhetstest for n\u00e5leslanger i henhold til ISO 9626<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a74594e e-con-full e-flex e-con e-child\" data-id=\"a74594e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-370bb8f elementor-widget elementor-widget-text-editor\" data-id=\"370bb8f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1844\" data-end=\"2038\">Den <strong data-start=\"1970\" data-end=\"2002\">stivhetstest for n\u00e5leslanger<\/strong> er en integrert del av ISO 9626. Denne testen evaluerer slangenes evne til \u00e5 motst\u00e5 b\u00f8yning under p\u00e5virkning av kraft. For \u00e5 utf\u00f8re testen p\u00e5f\u00f8res en spesifisert kraft p\u00e5 midten av en gitt r\u00f8rlengde, som st\u00f8ttes i begge ender. Deretter m\u00e5les hvor mye slangen b\u00f8yes.<\/p><h3>Utstyr for stivhetstesten<\/h3><p data-start=\"2321\" data-end=\"2655\">Stivhetstesten krever en <strong data-start=\"2351\" data-end=\"2382\">apparat for stivhetstesting<\/strong> som kan p\u00e5f\u00f8re en nedadrettet kraft p\u00e5 opptil <strong data-start=\"2429\" data-end=\"2437\">60 N<\/strong>. Dette apparatet skal ha et stempel med en stump kile i bunnen, og kraften som p\u00e5f\u00f8res skal m\u00e5les med en n\u00f8yaktighet p\u00e5 <strong data-start=\"2568\" data-end=\"2578\">\u00b10.1 N<\/strong>. Nedb\u00f8yningen av slangen skal m\u00e5les med en n\u00f8yaktighet p\u00e5 <strong data-start=\"2643\" data-end=\"2654\">0,01 mm<\/strong>.<\/p><p data-start=\"2657\" data-end=\"2958\">Testen gir viktige data for \u00e5 forst\u00e5 hvordan slangen til en n\u00e5l vil fungere under bruk, inkludert dens <strong data-start=\"2769\" data-end=\"2784\">fleksibilitet<\/strong> og evne til \u00e5 motst\u00e5 ytre krefter uten \u00e5 svikte. Produsenter er avhengige av <strong data-start=\"2869\" data-end=\"2887\">stivhetstest<\/strong> for \u00e5 sikre at produktene deres oppfyller de n\u00f8dvendige mekaniske standardene.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9f5ae8e elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"9f5ae8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance.webp\" class=\"attachment-large size-large wp-image-749\" alt=\"ISO 9626 Test av stivhet og bruddmotstand for n\u00e5leslanger\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-300x300.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-150x150.webp 150w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Stivhetstest og bruddmotstand for n\u00e5leslanger<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f25e92e elementor-widget elementor-widget-text-editor\" data-id=\"f25e92e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Motstand mot brudd p\u00e5 n\u00e5leslanger: Sikrer holdbarhet<\/h3><p data-start=\"3024\" data-end=\"3310\">En annen viktig test spesifisert i <strong data-start=\"3054\" data-end=\"3066\">ISO 9626<\/strong> er <a href=\"https:\/\/www.syringetest.com\/nb\/needle-tubing-breakage-resistance-test\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"3074\" data-end=\"3116\">Test av motstand mot brudd p\u00e5 n\u00e5leslanger<\/strong>.<\/a> Denne testen evaluerer n\u00e5leslangens evne til \u00e5 motst\u00e5 gjentatt b\u00f8ying uten \u00e5 brekke, noe som er kritisk i bruksomr\u00e5der der n\u00e5len kan bli utsatt for p\u00e5kjenninger under innsetting.<\/p><p data-start=\"3312\" data-end=\"3664\">Testen inneb\u00e6rer at slangen p\u00e5f\u00f8res en kraft, b\u00f8yes i en spesifisert vinkel og at b\u00f8yesyklusene gjentas. Slangen m\u00e5 t\u00e5le <strong data-start=\"3459\" data-end=\"3472\">20 sykluser<\/strong> b\u00f8yes i begge retninger uten \u00e5 brekke. Denne testen simulerer kreftene slangen kan bli utsatt for under rutinemessig bruk, og sikrer at n\u00e5len ikke svikter under normale forhold.<\/p><h3 data-start=\"3719\" data-end=\"4048\">Test av korrosjonsmotstand for n\u00e5leslanger<\/h3><p data-start=\"3719\" data-end=\"4048\">Den <strong data-start=\"3723\" data-end=\"3747\">korrosjonsbestandighet<\/strong> er en annen viktig egenskap, s\u00e6rlig for medisinsk utstyr som utsettes for ulike kjemikalier og steriliseringsprosesser. ISO 9626 beskriver en metode for \u00e5 teste korrosjonsbestandighet ved \u00e5 senke slangen ned i en <strong data-start=\"3974\" data-end=\"4002\">natriumkloridoppl\u00f8sning<\/strong> og observere effekten etter en bestemt periode.<\/p><p data-start=\"4050\" data-end=\"4434\">Testen inneb\u00e6rer at slangen senkes ned i en <strong data-start=\"4094\" data-end=\"4132\">0,5 mol\/l natriumkloridoppl\u00f8sning<\/strong> p\u00e5 <strong data-start=\"4136\" data-end=\"4148\">23 \u00b1 2\u00b0C<\/strong> for <strong data-start=\"4153\" data-end=\"4164\">7 timer<\/strong>. Etter nedsenkingsperioden inspiseres slangen for tegn p\u00e5 korrosjon. Korrosjonsbestandighet er avgj\u00f8rende for \u00e5 sikre lang levetid og integritet for kanyleslangene, spesielt i milj\u00f8er der de utsettes for saltvannsl\u00f8sninger eller steriliseringsmidler.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-196f14b e-flex e-con-boxed e-con e-parent\" data-id=\"196f14b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-aeb9a58 elementor-widget elementor-widget-heading\" data-id=\"aeb9a58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Velge riktig utstyr for spr\u00f8ytetesting<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b66d85 e-grid e-con-full e-con e-child\" data-id=\"1b66d85\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8e5c175 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"8e5c175\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-1.webp\" class=\"attachment-full size-full wp-image-750\" alt=\"ISO 9626 Stivhetstest og bruddmotstand for n\u00e5leslanger 1\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-1.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-1-300x300.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-1-150x150.webp 150w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-1-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">TS-01 Stivhetstester for r\u00f8r<\/h3><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d0d80d4 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"d0d80d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-2.webp\" class=\"attachment-full size-full wp-image-751\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-2.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-2-300x300.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-2-150x150.webp 150w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-9626-Needle-Tubing-Stiffness-Test-and-Breakage-Resistance-2-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">MST-01 Medisinsk spr\u00f8ytetester<\/h3><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-546e5c0 e-flex e-con-boxed e-con e-parent\" data-id=\"546e5c0\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9bd6bef elementor-widget elementor-widget-heading\" data-id=\"9bd6bef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Rollen til spr\u00f8yteslangens stivhetstester<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b983f6 elementor-widget elementor-widget-text-editor\" data-id=\"7b983f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4491\" data-end=\"4950\">For \u00e5 gjennomf\u00f8re n\u00f8yaktige <strong data-start=\"4511\" data-end=\"4544\">stivhetstester av n\u00e5leslanger<\/strong>, er det viktig \u00e5 bruke riktig utstyr. Det <strong data-start=\"4596\" data-end=\"4629\">Stivhetstester for spr\u00f8yteslanger<\/strong> er utviklet for \u00e5 m\u00e5le <strong data-start=\"4657\" data-end=\"4679\">b\u00f8yemotstand<\/strong> av n\u00e5leslanger, noe som sikrer at produktet oppfyller de n\u00f8dvendige standardene for bruk i medisinske applikasjoner. Instrumentet kan m\u00e5le nedb\u00f8yningen av slangen under varierende belastning, slik at produsentene kan vurdere kvaliteten p\u00e5 slangen og sikre holdbarheten.<\/p><p data-start=\"4952\" data-end=\"5261\">Stivhetstesteren for spr\u00f8yteslanger er sv\u00e6rt n\u00f8yaktig og gir p\u00e5litelige data som gj\u00f8r det mulig for produsenter \u00e5 sikre samsvar med <strong data-start=\"5076\" data-end=\"5088\">ISO 9626<\/strong> standarder. Ved hjelp av dette utstyret kan vi garantere at n\u00e5leslangene er stive nok til \u00e5 beholde sin form og integritet under bruk, men samtidig fleksible nok til at de enkelt kan settes inn.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1e2088e e-grid e-con-full e-con e-parent\" data-id=\"1e2088e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c84e9d5 elementor-widget elementor-widget-image\" data-id=\"c84e9d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2db946f e-con-full e-flex e-con e-child\" data-id=\"2db946f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8a85f93 elementor-widget elementor-widget-heading\" data-id=\"8a85f93\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvorfor velge <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b4a49d elementor-widget elementor-widget-text-editor\" data-id=\"6b4a49d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4917\" data-end=\"5240\">Ved \u00e5 f\u00f8lge <strong data-start=\"6439\" data-end=\"6451\">ISO 9626<\/strong> og ved hjelp av egnet testutstyr kan produsentene produsere holdbare kanyleslanger av h\u00f8y kvalitet som sikrer pasientenes sikkerhet og effekten av det medisinske utstyret.<\/p><p data-start=\"5242\" data-end=\"5537\"><strong>Syringetest.com<\/strong> gir avansert <strong data-start=\"5281\" data-end=\"5310\">utstyr for spr\u00f8ytetesting<\/strong> utviklet for \u00e5 st\u00f8tte fullstendig samsvar og str\u00f8mlinjeformede QC-arbeidsflyter. Hvis du \u00f8nsker \u00e5 oppgradere spr\u00f8ytevalideringsprosessen eller forbedre testn\u00f8yaktigheten, kan du kontakte oss for \u00e5 finne ut hvordan instrumentene v\u00e5re kan bidra til \u00e5 oppfylle dine standarder.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68036d0 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"68036d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/nb\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt oss<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 9626Needle Tubing Stiffness Test and Resistance Testing for Medical Devices ISO 9626 provides critical guidelines for testing stainless steel needle tubing used in medical devices, such as hypodermic needles. These tests, including the needle tubing stiffness test and breakage resistance, ensure that the tubing maintains mechanical integrity under various conditions, contributing to the safety [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":603,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-743","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/pages\/743","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/comments?post=743"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/pages\/743\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/pages\/603"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/media?parent=743"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}