{"id":277,"date":"2025-05-06T05:39:02","date_gmt":"2025-05-06T05:39:02","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=277"},"modified":"2026-05-09T06:43:14","modified_gmt":"2026-05-09T06:43:14","slug":"luer-lock-adaptor-collar-torque-resistance","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/nb\/luer-lock-adaptor-collar-torque-resistance","title":{"rendered":"Luer Lock-adapterkrage med dreiemomentmotstand"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"277\" class=\"elementor elementor-277\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ba8e23f e-flex e-con-boxed e-con e-parent\" data-id=\"ba8e23f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5a6414a elementor-widget elementor-widget-heading\" data-id=\"5a6414a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer Lock-adapterkrage med dreiemomentmotstand<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-43ca76c elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"43ca76c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Forst\u00e5else <strong>luer lock-adapterens krage motstand mot dreiemoment<\/strong> er avgj\u00f8rende for \u00e5 sikre kvaliteten og p\u00e5liteligheten til ferdigfylte spr\u00f8yter. Denne testen verifiserer Luer Lock Adaptor (LLA)-kragenes evne til \u00e5 motst\u00e5 rotasjonskrefter n\u00e5r en Luer-fitting, for eksempel en kanylehub, er festet. \u00c5 sikre at spr\u00f8ytene dine oppfyller ytelsesstandardene handler ikke bare om samsvar - det handler ogs\u00e5 om \u00e5 beskytte sluttbrukerne og opprettholde varemerkets omd\u00f8mme.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc76c2b e-flex e-con-boxed e-con e-parent\" data-id=\"dc76c2b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8a65884 elementor-widget elementor-widget-heading\" data-id=\"8a65884\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Betydningen av \u00e5 teste dreiemomentmotstanden til Luer Lock-adapterkragen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c41e388 elementor-widget elementor-widget-text-editor\" data-id=\"c41e388\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Den <strong>luer lock-adapterens krage motstand mot dreiemoment<\/strong> testen evaluerer den mekaniske stabiliteten til spr\u00f8ytens LLA-krage under vridningsbelastning. Hvis kragen svikter under eller etter p\u00e5setting av n\u00e5len, kan det f\u00f8re til alvorlige konsekvenser som lekkasje, feildosering eller til og med personskader.<\/p><p>Ved \u00e5 utf\u00f8re denne testen kan produsentene sikre:<\/p><ul><li>Spr\u00f8ytens mekaniske holdbarhet under klinisk bruk.<\/li><li>Overholdelse av internasjonale kvalitetsstandarder som <a href=\"https:\/\/www.syringetest.com\/nb\/iso-11040-4\/\"><strong>ISO 11040-4<\/strong><\/a>.<\/li><li>H\u00f8yere kundetilfredshet og f\u00e6rre tilbakekallinger av produkter.<\/li><li>Tryggere legemiddeladministrasjon for helsepersonell og pasienter.<\/li><\/ul><p>Testing av denne egenskapen er spesielt viktig for steriliserte, sammensatte spr\u00f8yter som er klare til fylling, for \u00e5 sikre at produktet opprettholder sin integritet fra produksjon til administrering.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-32d8f5e e-flex e-con-boxed e-con e-parent\" data-id=\"32d8f5e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-243d149 elementor-widget elementor-widget-heading\" data-id=\"243d149\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Annex G4 Krav til testing av dreiemomentmotstand<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-42454a3 elementor-widget elementor-widget-text-editor\" data-id=\"42454a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Den <strong>ISO 11040-4 Vedlegg G4<\/strong> avsnittet beskriver spesifikt hvordan du skal gjennomf\u00f8re <strong>luer lock-adapterens krage motstand mot dreiemoment<\/strong> tester p\u00e5 en konsekvent og standardisert m\u00e5te. Her er en oversikt over det viktigste:<\/p><h3>Prinsipp<\/h3><p>Metoden vurderer om LLA-kragen kan motst\u00e5 en rotasjonskraft som p\u00e5f\u00f8res under tilkobling av en Luer-kobling. Kragen m\u00e5 sitte godt fast uten at den beveger seg for mye eller l\u00f8sner.<\/p><h3>Materialer og utstyr<\/h3><ul><li><strong>Testpr\u00f8ver<\/strong>: Steriliserte, sammensatte spr\u00f8yter klare til \u00e5 fylles med LLA.<\/li><li><strong>Momenttester<\/strong>: Utstyrt med en rotasjonsenhet som kan rotere 20 ganger i minuttet.<\/li><li><strong>Momentf\u00f8ler<\/strong>: 35 Ncm kapasitet med 0,05 Ncm oppl\u00f8sning.<\/li><li><strong>Pr\u00f8vetakingsfrekvens<\/strong>: 500 Hz anbefales for toppm\u00e5linger.<\/li><\/ul><p>Det er viktig \u00e5 bruke kalibrert utstyr for \u00e5 sikre at m\u00e5lingene er n\u00f8yaktige. Syringetest.coms l\u00f8sninger for momenttesting gir h\u00f8ye samplingshastigheter og p\u00e5litelig datainnsamling for \u00e5 oppfylle disse behovene.<\/p><h3>Forberedelse av testpr\u00f8ver<\/h3><p>Testpr\u00f8ver b\u00f8r h\u00e5ndteres under samme forhold som det endelige produktet som leveres. Konsistens sikrer at testresultatene gjenspeiler ytelsen i den virkelige verden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fe46b5f e-flex e-con-boxed e-con e-parent\" data-id=\"fe46b5f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1c58ff4 elementor-widget elementor-widget-heading\" data-id=\"1c58ff4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Trinn-for-trinn-testprosedyre<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf42e77 elementor-widget elementor-widget-text-editor\" data-id=\"bf42e77\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utf\u00f8re en <strong>luer lock-adapterens krage motstand mot dreiemoment<\/strong> test i henhold til <strong>ISO 11040-4 Vedlegg G4<\/strong> inneb\u00e6rer f\u00f8lgende trinn:<\/p><ol><li><strong>Eksempel p\u00e5 oppsett<\/strong>: Sett den steriliserte spr\u00f8yten loddrett inn i spr\u00f8yteholderen.<\/li><li><strong>Fjerning av spisshette<\/strong>: Fjern spisshetten forsiktig manuelt for \u00e5 unng\u00e5 \u00e5 p\u00e5f\u00f8re for h\u00f8yt dreiemoment.<\/li><li><strong>Montering av griper<\/strong>: Fest LLA-halsb\u00e5ndholderen godt p\u00e5 halsb\u00e5ndet.<\/li><li><strong>Nullstilling<\/strong>: Sett momentf\u00f8leren til null uten \u00e5 p\u00e5f\u00f8re noe startmoment.<\/li><li><strong>Rotasjonshastighet<\/strong>: Juster rotasjonen til 20 omdreininger per minutt (eller etter avtale med kunden).<\/li><li><strong>Test Start<\/strong>: Roter dreieskiven 90\u00b0 med eller mot klokken, eller roter selve lukkingen.<\/li><li><strong>Registrering av maksimalt dreiemoment<\/strong>: Registrer det maksimale dreiemomentet i det \u00f8yeblikket kragen begynner \u00e5 rotere.<\/li><\/ol><p>Det maksimalt registrerte dreiemomentet representerer kragens motstand mot rotasjonskraft og m\u00e5 oppfylle spesifikasjonene som er definert i produktstandardene.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bec81ba e-con-full e-flex e-con e-child\" data-id=\"bec81ba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf895da elementor-widget elementor-widget-text-editor\" data-id=\"bf895da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Uttrykk og rapportering av testresultater<\/h3><p>Etter at testen er fullf\u00f8rt, er det viktig \u00e5 dokumentere:<\/p><ul><li>Den m\u00e5lte maksimale dreiemomentverdien (i Ncm).<\/li><li>Rotasjonshastigheten som brukes.<\/li><li>Antall testede og godkjente pr\u00f8ver.<\/li><li>Eventuelle observerte avvik eller uregelmessigheter.<\/li><\/ul><p>Sporbarhet er avgj\u00f8rende. Selv om enkelte oppsettparametere ikke skrives ut automatisk, b\u00f8r de logges manuelt for \u00e5 opprettholde full sporbarhet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-054461f elementor-widget elementor-widget-image\" data-id=\"054461f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"330\" height=\"320\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp\" class=\"attachment-large size-large wp-image-280\" alt=\"Luer Lock-adapterkrage med dreiemomentmotstand - ISO 11040-4 vedlegg G4\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp 330w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4-300x291.webp 300w\" sizes=\"(max-width: 330px) 100vw, 330px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3b32991 e-grid e-con-full e-con e-parent\" data-id=\"3b32991\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11c9fc9 elementor-widget elementor-widget-image\" data-id=\"11c9fc9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-50e8f10 e-con-full e-flex e-con e-child\" data-id=\"50e8f10\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0b4cdfa elementor-widget elementor-widget-heading\" data-id=\"0b4cdfa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvorfor velge <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7339cce elementor-widget elementor-widget-text-editor\" data-id=\"7339cce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"203\" data-end=\"463\">P\u00e5 <strong>Syringetest.com<\/strong>Vi samler ekspertise, innovasjon, fra presis prosjektering til personlig service for \u00e5 st\u00f8tte v\u00e5re kunder over hele verden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ce9df1f elementor-widget elementor-widget-text-editor\" data-id=\"ce9df1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Hos Syringetest.com forst\u00e5r vi at p\u00e5litelig <strong>luer lock-adapterens krage motstand mot dreiemoment<\/strong> testing er avgj\u00f8rende for at spr\u00f8yteproduktene dine skal bli en suksess. Vi tilbyr momenttestere med h\u00f8y presisjon som oppfyller eller overg\u00e5r kravene i <strong>ISO 11040-4<\/strong> og <strong>ISO 11040-4 Vedlegg G4<\/strong>. Instrumentene v\u00e5re er utstyrt med:<\/p><ul><li><strong>H\u00f8ye samplingsfrekvenser<\/strong> for bedre toppn\u00f8yaktighet.<\/li><li><strong>Brukervennlig programvare<\/strong> med fullstendig testdokumentasjon.<\/li><li><strong>Tilpassbare armaturer<\/strong> for \u00e5 passe til ulike spr\u00f8yteutf\u00f8relser.<\/li><\/ul><p>I tillegg bist\u00e5r vi kundene v\u00e5re med teknisk ekspertise og tilpasning av automatiseringsl\u00f8sninger, slik at testarbeidsflyten blir effektiv, n\u00f8yaktig og i samsvar med kravene.<\/p><p>Testing <strong>luer lock-adapterens krage motstand mot dreiemoment<\/strong> i henhold til <strong>ISO 11040-4 Vedlegg G4<\/strong> er ikke bare en forskriftsmessig formalitet - det er et kritisk kvalitetskontrolltrinn som sikrer produktsikkerhet, p\u00e5litelighet og brukertilfredshet. Med riktig utstyr og testmetodikk kan du trygt lansere sikre og forskriftsmessige spr\u00f8yteprodukter p\u00e5 markedet.<\/p><p>Hvis du trenger hjelp med \u00e5 sette opp momentmotstandstester eller velge de riktige testinstrumentene, <strong>Syringetest.com<\/strong> er her for \u00e5 hjelpe deg. Kontakt oss i dag for \u00e5 f\u00e5 mer informasjon om v\u00e5re l\u00f8sninger som er skreddersydd for dine behov for spr\u00f8ytetesting.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb0e531 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"eb0e531\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/nb\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt oss<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Adaptor Collar Torque Resistance Understanding luer lock adaptor collar torque resistance is critical for ensuring the quality and reliability of prefilled syringe assemblies. This test verifies the ability of the Luer Lock Adaptor (LLA) collar to resist rotational forces when a Luer fitting, such as a needle hub, is attached. Ensuring that your [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-277","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/pages\/277","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/comments?post=277"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/pages\/277\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/media?parent=277"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}