{"id":247,"date":"2025-05-06T02:59:16","date_gmt":"2025-05-06T02:59:16","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=247"},"modified":"2026-05-14T08:15:29","modified_gmt":"2026-05-14T08:15:29","slug":"needle-tubing-stiffness-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/nb\/needle-tubing-stiffness-test","title":{"rendered":"Stivhetstest for n\u00e5leslanger"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"247\" class=\"elementor elementor-247\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1e601d7 e-flex e-con-boxed e-con e-parent\" data-id=\"1e601d7\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0e5a4e8 elementor-widget elementor-widget-heading\" data-id=\"0e5a4e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Stivhetstest for n\u00e5leslanger<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-307f5d3 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"307f5d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Den <strong>stivhetstest for n\u00e5leslanger<\/strong> spiller en avgj\u00f8rende rolle n\u00e5r det gjelder \u00e5 sikre ytelsen og sikkerheten til medisinsk utstyr, spesielt injeksjonsn\u00e5ler. Denne testen fastsl\u00e5r hvor motstandsdyktig slangen av rustfritt st\u00e5l er mot b\u00f8ying n\u00e5r den utsettes for en standardisert kraft. For fagfolk i bransjen for medisinsk utstyr - spesielt de som er involvert i kvalitetssikring av spr\u00f8yter - er det avgj\u00f8rende \u00e5 forst\u00e5 denne testen for \u00e5 kunne oppfylle lovp\u00e5lagte standarder og sikre pasientsikkerheten.<\/p><p>Syringetest.com tilbyr l\u00f8sninger med h\u00f8y presisjon for stivhetstester av kanyleslanger, noe som sikrer at produktene dine er i samsvar med globale standarder som <strong>ISO 9626<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5684a6e e-flex e-con-boxed e-con e-parent\" data-id=\"5684a6e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-02d54a2 elementor-widget elementor-widget-heading\" data-id=\"02d54a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 9626 og ISO 9626 vedlegg B<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b9bcb4 e-con-full e-flex e-con e-child\" data-id=\"1b9bcb4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c55fa1a elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"c55fa1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.syringetest.com\/nb\/standards\/iso-9626\/\"><strong>ISO 9626<\/strong><\/a>, med tittelen <em>N\u00e5leslanger av rustfritt st\u00e5l for produksjon av medisinsk utstyr - Krav og pr\u00f8vingsmetoder<\/em>, fastsetter de fysiske og mekaniske kriteriene for slanger av rustfritt st\u00e5l som brukes i medisinsk utstyr. Blant de viktigste komponentene, <strong>ISO 9626 Vedlegg B<\/strong> gir en detaljert metode for \u00e5 utf\u00f8re <strong>stivhetstest for n\u00e5leslanger<\/strong>med strenge krav til prosedyrer og utstyrsspesifikasjoner.<\/p><p>Vedlegg B beskriver hvordan man kan vurdere stivheten ved \u00e5 bruke en <strong>spesifisert kraft<\/strong> til midten av slangen som st\u00f8ttes i begge ender, og m\u00e5le <strong>resulterende avb\u00f8yning<\/strong>. Denne prosessen bidrar til \u00e5 evaluere om slangen har den mekaniske styrken som kreves for \u00e5 t\u00e5le praktisk bruk uten \u00e5 b\u00f8ye seg eller g\u00e5 i stykker.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25a7788 elementor-widget elementor-widget-image\" data-id=\"25a7788\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"590\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard.webp\" class=\"attachment-large size-large wp-image-99\" alt=\"standard for testing av brudd- og glidekraft\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard-300x295.webp 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd39b91 e-con-full e-flex e-con e-child\" data-id=\"fd39b91\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-315872e elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"315872e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Testprinsipp og signifikans<\/h3><p>Kjerneprinsippet for <strong>stivhetstest for n\u00e5leslanger<\/strong> er enkel: En fast, nedadrettet kraft p\u00e5f\u00f8res midten av n\u00e5leslangen, som er horisontalt st\u00f8ttet i begge ender. Den <strong>mengde avb\u00f8yning<\/strong> ved kraftp\u00e5f\u00f8ringspunktet indikerer slangens stivhet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0b91159 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"0b91159\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Hvorfor er dette viktig?<\/h3><ul><li><strong>Produktsikkerhet:<\/strong> Unng\u00e5 b\u00f8ying eller brudd under injeksjon.<\/li><li><strong>Konsistens i produksjonen:<\/strong> S\u00f8rg for at hvert parti oppfyller de samme mekaniske standardene.<\/li><li><strong>Overholdelse av lover og regler:<\/strong> M\u00f8t <strong>ISO 9626<\/strong> sertifisering for global markedsadgang.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2176b2b e-flex e-con-boxed e-con e-parent\" data-id=\"2176b2b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0601f88 elementor-widget elementor-widget-heading\" data-id=\"0601f88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">N\u00f8dvendig utstyr for stivhetstest av n\u00e5leslanger<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91dcc43 elementor-widget elementor-widget-text-editor\" data-id=\"91dcc43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>For \u00e5 utf\u00f8re testen i henhold til <strong>ISO 9626 Vedlegg B<\/strong>er f\u00f8lgende apparatur n\u00f8dvendig:<\/p><h3>Apparat for stivhetstesting<\/h3><p class=\"\" data-start=\"2125\" data-end=\"2247\">I stand til \u00e5 p\u00e5f\u00f8re opptil <strong>60 N<\/strong> av kraft med en n\u00f8yaktighet p\u00e5 <strong>\u00b10.1 N<\/strong>, med en <strong>stump kileformet stempel<\/strong>. Kilen m\u00e5 best\u00e5 av to flate overflater som er skr\u00e5stilt p\u00e5 <strong>60\u00b0<\/strong>, gjennomsk\u00e5ret av en sylindrisk flate med en <strong>1 mm radius<\/strong>.<\/p><h3 data-start=\"2125\" data-end=\"2247\">Enhet for m\u00e5ling av avb\u00f8yning<\/h3><p class=\"\" data-start=\"2755\" data-end=\"3082\">N\u00f8yaktig til <strong>0,01 mm<\/strong>brukes til \u00e5 registrere hvor mye slangen b\u00f8yes under den p\u00e5f\u00f8rte kraften.<\/p><p>Syringetest.com tilbyr tilpassbare testinstrumenter som oppfyller alle disse tekniske kravene, og hjelper laboratorier og produsenter med \u00e5 implementere standardiserte og repeterbare testprosesser.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-512b05c e-flex e-con-boxed e-con e-parent\" data-id=\"512b05c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-820f2d6 elementor-widget elementor-widget-heading\" data-id=\"820f2d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fremgangsm\u00e5te for stivhetstest av n\u00e5leslanger<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9839f71 elementor-widget elementor-widget-text-editor\" data-id=\"9839f71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>1. Plassering av pr\u00f8ver<\/h3><p>Plasser slangen p\u00e5 testapparatet. S\u00f8rg for at:<\/p><ul><li>Den <strong>spennvidde<\/strong> samsvarer med verdiene i ISO 9626 tabell 2 for den aktuelle r\u00f8rst\u00f8rrelsen.<\/li><li>Den <strong>stempel<\/strong> er sentrert.<\/li><li>Slangen er orientert <strong>vinkelrett<\/strong> til b\u00e5de stempelet og st\u00f8ttepunktene.<\/li><\/ul><h3>2. P\u00e5f\u00f8ring av kraft<\/h3><p>P\u00e5f\u00f8r den nedadg\u00e5ende kraften som er spesifisert for slangest\u00f8rrelsen, med en kontrollert hastighet p\u00e5 <strong>1 mm\/min til 10 mm\/min<\/strong>.<\/p><h3>3. M\u00e5ling av nedb\u00f8yning<\/h3><p>M\u00e5l og registrer <strong>avb\u00f8yning<\/strong> av slangen i midten med en n\u00f8yaktighet p\u00e5 <strong>\u00b10,01 mm<\/strong>.<\/p><h3>4. Rapportering av resultater<\/h3><p>En fullstendig testrapport m\u00e5 inneholde:<\/p><ul><li>Slangest\u00f8rrelse og identifikasjon<\/li><li>Slangetype (RW, TW, ETW, UTW)<\/li><li>M\u00e5lt avb\u00f8yning<\/li><li>Dato for testing<\/li><li>Legering av rustfritt st\u00e5l<\/li><\/ul><p>Syringetest.coms automatiserte stivhetstestere forenkler denne prosessen ved \u00e5 integrere <strong>presisjonssensorer<\/strong> og <strong>brukervennlige grensesnitt<\/strong> for \u00e5 sikre repeterbarhet og sporbarhet av testresultatene.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b7a8cd e-grid e-con-full e-con e-parent\" data-id=\"7b7a8cd\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ce47441 elementor-widget elementor-widget-image\" data-id=\"ce47441\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-413684e e-con-full e-flex e-con e-child\" data-id=\"413684e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5ae9222 elementor-widget elementor-widget-heading\" data-id=\"5ae9222\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvorfor velge <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ee84ad elementor-widget elementor-widget-text-editor\" data-id=\"8ee84ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Som en p\u00e5litelig leverand\u00f8r av l\u00f8sninger for materialtesting, <strong>Syringetest.com<\/strong> leverer instrumenter som oppfyller og overg\u00e5r ISO-standardene. V\u00e5re stivhetstestere er konstruert for:<\/p><ul><li><strong>H\u00f8y presisjon og p\u00e5litelighet<\/strong><\/li><li><strong>Brukertilpasning<\/strong> for spesielle r\u00f8rst\u00f8rrelser eller legeringstyper<\/li><li><strong>Alternativer for automatisering<\/strong> for \u00e5 \u00f8ke testeffektiviteten<\/li><li><strong>Datalogging og sporbarhet<\/strong> for revisjonsberedskap<\/li><\/ul><p>Vi betjener bransjer som spenner fra <strong>medisinsk utstyr og legemidler til laboratorier for kvalitetskontroll<\/strong>. Med et sterkt fokus p\u00e5 innovasjon st\u00f8tter vi ogs\u00e5 <strong>oppgraderinger av automatisering<\/strong> og <strong>utvikling av tilpassede tester<\/strong>.<\/p><p>Den <strong>stivhetstest for n\u00e5leslanger<\/strong>n\u00e5r det utf\u00f8res p\u00e5 riktig m\u00e5te under <strong>ISO 9626 Vedlegg B<\/strong>sikrer at medisinske slanger opprettholder mekanisk integritet under bruk. Det handler ikke bare om samsvar - det handler om <strong>beskytte pasientene og opprettholde tilliten<\/strong> i medisinske produkter.<\/p><p>Med profesjonelle testinstrumenter fra <strong>Syringetest.com<\/strong>kan produsentene trygt sikre produktkvaliteten, oppfylle internasjonale standarder og effektivisere kvalitetskontrollprosessene.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-383dde0 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"383dde0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/nb\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt oss<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Needle Tubing Stiffness Test The needle tubing stiffness test plays a critical role in ensuring the performance and safety of medical devices, particularly hypodermic needles. This test determines the resistance of stainless steel tubing to bending when a standardized force is applied. For professionals in the medical device industry\u2014especially those involved in quality assurance of [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-247","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/pages\/247","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/comments?post=247"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/pages\/247\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/nb\/wp-json\/wp\/v2\/media?parent=247"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}