{"id":824,"date":"2026-03-30T06:33:39","date_gmt":"2026-03-30T06:33:39","guid":{"rendered":"https:\/\/www.syringetest.com\/?p=824"},"modified":"2026-03-30T06:33:40","modified_gmt":"2026-03-30T06:33:40","slug":"iso9626-annex-b","status":"publish","type":"post","link":"https:\/\/www.syringetest.com\/lv\/iso9626-annex-b","title":{"rendered":"Izpratne par ISO9626 B pielikumu: adatu cauru\u013cu stinguma testa metode"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Ievads ISO9626 B pielikum\u0101<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Port\u0101ls <strong>ISO9626 B pielikums<\/strong> Standarts nodro\u0161ina visaptvero\u0161u test\u0113\u0161anas metodi medic\u012bnas ier\u012bc\u0113s izmantoto adatu caurul\u012b\u0161u stingr\u012bbas nov\u0113rt\u0113\u0161anai. \u0160is tests ir b\u016btisks, lai nodro\u0161in\u0101tu, ka <strong>adatu caurul\u012btes<\/strong> nodro\u0161ina nepiecie\u0161amo stingr\u012bbu dro\u0161ai un efekt\u012bvai izmanto\u0161anai medic\u012bn\u0101, piem\u0113ram, \u0161\u013circ\u0113m un injekcij\u0101m. Iev\u0113rojot \u0161o standartu, ra\u017eot\u0101ji var garant\u0113t, ka vi\u0146u izstr\u0101d\u0101jumi atbilst nepiecie\u0161amajiem dro\u0161\u012bbas un veiktsp\u0113jas krit\u0113rijiem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Port\u0101ls <strong>adatu cauru\u013cu stinguma tests<\/strong> ISO9626 B pielikum\u0101 aprakst\u012bt\u0101 proced\u016bra ir kritiski svar\u012bga proced\u016bra medic\u012bnas ier\u012b\u010du ra\u017eot\u0101jiem, jo \u012bpa\u0161i tiem, kas str\u0101d\u0101 ar \u0161\u013circ\u0113m un citiem injic\u0113jamiem produktiem. \u0160is tests pal\u012bdz noteikt, vai adatas caurul\u012btei ir atbilsto\u0161as meh\u0101nisk\u0101s \u012bpa\u0161\u012bbas, lai t\u0101 efekt\u012bvi darbotos bez boj\u0101jumu riska lieto\u0161anas laik\u0101.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/www.syringetest.com\/lv\/standards\/iso-9626\/\" target=\"_blank\" rel=\" noreferrer noopener\"><img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/03\/ISO9626-Annex-B-Tubing-Stiffness-Test.webp\" alt=\"ISO9626 B pielikums Cauru\u013cu stinguma tests\" class=\"wp-image-826\" style=\"width:793px;height:auto\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/03\/ISO9626-Annex-B-Tubing-Stiffness-Test.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/03\/ISO9626-Annex-B-Tubing-Stiffness-Test-300x300.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/03\/ISO9626-Annex-B-Tubing-Stiffness-Test-150x150.webp 150w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/03\/ISO9626-Annex-B-Tubing-Stiffness-Test-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Kas ir ISO9626 B pielikums?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ISO9626 ir standarts, kas reglament\u0113 <strong>medic\u012bnisko adatu caurul\u012b\u0161u ra\u017eo\u0161ana un test\u0113\u0161ana<\/strong> ko izmanto \u0161\u013cir\u010du un citu medic\u012bnas ier\u012b\u010du ra\u017eo\u0161an\u0101. B pielikum\u0101 \u012bpa\u0161a uzman\u012bba piev\u0113rsta cauru\u013cu stingr\u012bbai, kas ir b\u016btiska \u0161\u013cir\u010du darb\u012bbai un to sp\u0113jai dro\u0161i un dro\u0161i ievad\u012bt saturu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">B pielikum\u0101 test\u0113\u0161anas proced\u016bra ietver sp\u0113ka pielik\u0161anu caurules centram, kas ir balst\u012bts abos galos, un radu\u0161\u0101s deform\u0101cijas m\u0113r\u012b\u0161anu. Tas \u013cauj ra\u017eot\u0101jiem nov\u0113rt\u0113t, vai caurul\u012btes stingr\u012bba atbilst nepiecie\u0161amaj\u0101m specifik\u0101cij\u0101m izmanto\u0161anai \u0161\u013circ\u0113s, adat\u0101s un l\u012bdz\u012bg\u0101s medic\u012bnas ier\u012bc\u0113s.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Adatu cauru\u013cu stinguma tests: Galven\u0101 proced\u016bra<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Port\u0101ls <strong>adatu cauru\u013cu stinguma tests<\/strong> tiek veikta, izmantojot specializ\u0113tu apar\u0101tu, ar kuru uz caurul\u0113m iedarbojas ar noteiktu sp\u0113ku un m\u0113ra to deform\u0101ciju. Testu veic saska\u0146\u0101 ar ISO9626 B pielikum\u0101 sniegtaj\u0101m vadl\u012bnij\u0101m, kur\u0101s nor\u0101d\u012bti nepiecie\u0161amie parametri un apr\u012bkojums.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3 punktu saliekuma tests cauru\u013cu stingruma noteik\u0161anai<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Port\u0101ls <strong>3 punktu lieces tests<\/strong> ir b\u016btiska da\u013ca no <strong>adatu cauru\u013cu stinguma tests<\/strong>. \u0160aj\u0101 proced\u016br\u0101 caurul\u012bti novieto uz test\u0113\u0161anas apar\u0101ta, kas uz caurules centru iedarbojas ar lejupv\u0113rstu sp\u0113ku. . <strong>span<\/strong> starp abiem balsta galiem tiek piel\u0101gots atbilsto\u0161i konkr\u0113t\u0101 caurules izm\u0113ra standartam.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tiek izm\u0113r\u012bts deform\u0101cijas lielums caurules centr\u0101, un \u0161o deform\u0101cijas v\u0113rt\u012bbu izmanto, lai nov\u0113rt\u0113tu caurules stingr\u012bbu. \u0160is tests nodro\u0161ina, ka <strong>adatu caurul\u012btes<\/strong> ir pareizais stingr\u012bbas un elast\u012bbas l\u012bdzsvars, kas ir \u013coti svar\u012bgs \u0161\u013cir\u010du un citu medic\u012bnas ier\u012b\u010du dro\u0161\u012bbai un funkcionalit\u0101tei.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Adatu cauru\u013cu stinguma testa apar\u0101ts<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Lai veiktu <strong>adatu cauru\u013cu stinguma tests<\/strong>, apar\u0101tam j\u0101atbilst \u012bpa\u0161\u0101m pras\u012bb\u0101m, kas izkl\u0101st\u012btas ISO9626 B pielikum\u0101:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Virzu\u013ci<\/strong>: Lai pielietotu sp\u0113ku uz caurul\u0113m, izmanto bl\u012bvu \u0137\u012b\u013ca formas virzuli ar cilindrisku 1 mm r\u0101diusu. Virzulim j\u0101sp\u0113j pielikt sp\u0113ku l\u012bdz 60 N ar precizit\u0101ti \u00b1 0,1 N.<\/li>\n\n\n\n<li><strong>Deform\u0101cijas m\u0113r\u012b\u0161anas iek\u0101rtas<\/strong>: Deform\u0101cijas m\u0113r\u012b\u0161anai izmantotajam apr\u012bkojumam j\u0101b\u016bt \u013coti prec\u012bzam, lai var\u0113tu izm\u0113r\u012bt deform\u0101ciju ar precizit\u0101ti l\u012bdz 0,01 mm.<\/li>\n\n\n\n<li><strong>Atbalsts un Span<\/strong>: Caurul\u0113m j\u0101b\u016bt balst\u012bt\u0101m abos galos, un att\u0101lums starp balstiem j\u0101piel\u0101go atbilsto\u0161i nor\u0101d\u012btajiem cauru\u013cu izm\u0113riem.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Injic\u0113jam\u012bbas tests un t\u0101 noz\u012bme<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Papildus <strong>adatu cauru\u013cu stinguma tests<\/strong>, un <strong>Injic\u0113jam\u012bbas tests<\/strong> ir v\u0113l viens svar\u012bgs medic\u012bnisko adatu un \u0161\u013cir\u010du nov\u0113rt\u0113jums. Ar \u0161o testu nov\u0113rt\u0113, cik viegli var injic\u0113t saturu caur adatu, nodro\u0161inot, ka adata nerada p\u0101rm\u0113r\u012bgu pretest\u012bbu vai probl\u0113mas injekcijas proces\u0101.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Port\u0101ls <strong>Injic\u0113jam\u012bbas tests<\/strong> bie\u017ei vien imit\u0113 re\u0101los apst\u0101k\u013cus, piem\u0113rojot spiedienu uz \u0161\u013circi un izm\u0113rot sp\u0113ku, kas nepiecie\u0161ams, lai ievad\u012btu saturu. P\u0101r\u0101k stingra adata var rad\u012bt gr\u016bt\u012bbas injekcijas veik\u0161an\u0101, savuk\u0101rt p\u0101r\u0101k elast\u012bga adata var izrais\u012bt nestabilit\u0101ti vai iesp\u0113jamu k\u013c\u016bmi.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u0160\u013cir\u010du test\u0113\u0161anas iek\u0101rtu loma<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ra\u017eot\u0101jiem, kas iev\u0113ro <strong>ISO9626 B pielikums<\/strong>, izmantojot prec\u012bzu <strong>\u0161\u013cir\u010du test\u0113\u0161anas iek\u0101rtas<\/strong> ir b\u016btiska. \u0160is apr\u012bkojums nodro\u0161ina, ka <strong>adatu cauru\u013cu stinguma tests<\/strong> un <strong>Injic\u0113jam\u012bbas tests<\/strong> tiek veikti prec\u012bzi un konsekventi. Augstas kvalit\u0101tes test\u0113\u0161anas instrumenti \u013cauj ra\u017eot\u0101jiem izpild\u012bt normat\u012bv\u0101s pras\u012bbas un pieg\u0101d\u0101t dro\u0161us un uzticamus produktus.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Piem\u0113ram. <strong>Cauru\u013cu stinguma testeris<\/strong> no <strong>\u0160\u016bnu instrumenti<\/strong> ir izstr\u0101d\u0101ts, lai nodro\u0161in\u0101tu prec\u012bzus stinguma m\u0113r\u012bjumus adatu caurul\u0113m. \u0160is instruments ir ide\u0101li piem\u0113rots <strong>adatu caurul\u012b\u0161u st\u012bvums<\/strong> \u0161\u013circ\u0113s un cit\u0101s medic\u012bniskaj\u0101s ier\u012bc\u0113s, nodro\u0161inot atbilst\u012bbu <strong>ISO9626 B pielikums<\/strong> un citiem attiec\u012bgajiem standartiem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Port\u0101ls <strong>ISO9626 B pielikums<\/strong> standartam ir iz\u0161\u0137iro\u0161a noz\u012bme medic\u012bniskaj\u0101s ier\u012bc\u0113s izmantoto adatu caurul\u012b\u0161u dro\u0161uma un veiktsp\u0113jas nodro\u0161in\u0101\u0161an\u0101. . <strong>adatu cauru\u013cu stinguma tests<\/strong> ir \u013coti svar\u012bgi, lai p\u0101rbaud\u012btu, vai caurul\u012btes sp\u0113j iztur\u0113t lieto\u0161anas laik\u0101 radu\u0161os sp\u0113kus, vienlaikus saglab\u0101jot injekcijas proced\u016br\u0101m nepiecie\u0161amo elast\u012bbu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ra\u017eot\u0101ji var nodro\u0161in\u0101t, ka vi\u0146u ra\u017eojumi atbilst nepiecie\u0161amajiem veiktsp\u0113jas standartiem, ievie\u0161ot <strong>3 punktu lieces tests<\/strong> cauru\u013cu stingr\u012bbu un uzticamu <strong>\u0161\u013cir\u010du test\u0113\u0161anas iek\u0101rtas<\/strong> kvalit\u0101tes kontroles procesos. <strong>\u0160\u016bnu instrumenti<\/strong> pied\u0101v\u0101 uzlabotas <strong>Cauru\u013cu stinguma testeri<\/strong> lai pal\u012bdz\u0113tu ra\u017eot\u0101jiem izpild\u012bt \u0161\u012bs stingr\u0101s pras\u012bbas un nodro\u0161in\u0101t medic\u012bnas produktu kvalit\u0101ti.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction to ISO9626 Annex B The ISO9626 Annex B standard provides a comprehensive testing method for evaluating the stiffness of needle tubing used in medical devices. This test is essential for ensuring that the needle tubing maintains the necessary rigidity for safe and effective use in medical applications, such as syringes and injectables. By following [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-824","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/lv\/wp-json\/wp\/v2\/posts\/824","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/lv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.syringetest.com\/lv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/lv\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/lv\/wp-json\/wp\/v2\/comments?post=824"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/lv\/wp-json\/wp\/v2\/posts\/824\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/lv\/wp-json\/wp\/v2\/media?parent=824"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.syringetest.com\/lv\/wp-json\/wp\/v2\/categories?post=824"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.syringetest.com\/lv\/wp-json\/wp\/v2\/tags?post=824"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}