{"id":608,"date":"2025-07-02T05:36:28","date_gmt":"2025-07-02T05:36:28","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=608"},"modified":"2026-05-19T07:09:42","modified_gmt":"2026-05-19T07:09:42","slug":"iso-7886-1","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/lt\/standartai\/iso-7886-1","title":{"rendered":"ISO 7886-1"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"608\" class=\"elementor elementor-608\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f03c7a9 e-flex e-con-boxed e-con e-parent\" data-id=\"f03c7a9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1212df8 elementor-widget elementor-widget-heading\" data-id=\"1212df8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 7886-1 \u0161virk\u0161t\u0173 funkcionalumo bandymo standartas<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1cd79c0 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"1cd79c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"389\" data-end=\"862\"><strong data-start=\"408\" data-end=\"422\">ISO 7886-1<\/strong> yra tarptautiniu mastu pripa\u017eintas standartas, apibr\u0117\u017eiantis eksploatacinius ir bandymo reikalavimus, taikomus <em data-start=\"524\" data-end=\"599\">steril\u016bs vienkartiniai poodiniai \u0161virk\u0161tai, skirti naudoti rankomis<\/em>. \u0160is standartas atlieka svarb\u0173 vaidmen\u012f \u0161virk\u0161t\u0173 kokyb\u0117s kontrol\u0117je, u\u017etikrinant funkcin\u0119 saug\u0105 ir pacient\u0173 apsaug\u0105. Kokyb\u0117s kontrol\u0117s in\u017einieriai ir reguliavimo specialistai remiasi \u0161iuo dokumentu, kad gal\u0117t\u0173 vadovautis <em data-start=\"797\" data-end=\"828\">\u0161virk\u0161to funkcionalumo testavimas<\/em> ir patvirtinti gaminio veikim\u0105. I\u0161 <strong data-start=\"869\" data-end=\"908\">atsipalaidavimo ir slydimo j\u0117gos bandymai<\/strong> \u012f <strong data-start=\"912\" data-end=\"936\">\u0161virk\u0161t\u0173 sandarumo testavimas<\/strong>, ISO 7886-1 apra\u0161yti tiksl\u016bs \u0161virk\u0161t\u0173 vientisumo vertinimo bandymo metodai.\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1cadcda e-flex e-con-boxed e-con e-parent\" data-id=\"1cadcda\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5506c95 elementor-widget elementor-widget-heading\" data-id=\"5506c95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pagrindiniai veiklos reikalavimai pagal ISO 7886-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd9cbb4 elementor-widget elementor-widget-text-editor\" data-id=\"dd9cbb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Negyva erdv\u0117<\/h3><p data-start=\"347\" data-end=\"741\">Siekiant suma\u017einti vaist\u0173 \u0161vaistym\u0105 ir kry\u017emin\u0117s tar\u0161os rizik\u0105, ISO 7886-1 reikalaujama, kad \u0161virk\u0161to negyvoji erdv\u0117 - likutinis skys\u010dio t\u016bris, lik\u0119s po pilno st\u016bmoklio \u012fki\u0161imo, - b\u016bt\u0173 kuo ma\u017eesn\u0117.<\/p><h3>Oro ir skys\u010di\u0173 nuot\u0117kis<\/h3><p data-start=\"743\" data-end=\"1267\">\u0160virk\u0161tai turi pasi\u017eym\u0117ti patikimu sandarumu. Pagal <em data-start=\"850\" data-end=\"859\">D priedas<\/em>, tur\u0117t\u0173 b\u016bti <strong data-start=\"877\" data-end=\"908\">n\u0117ra matomo vandens nutek\u0117jimo<\/strong> u\u017e st\u016bmoklio kam\u0161\u010dio arba sandariklio suspaudimo. Nors tarp vidini\u0173 sandarikli\u0173 gali patekti nedideli la\u0161eliai, i\u0161orinis nuot\u0117kis rei\u0161kia gedim\u0105. Be to, <em data-start=\"1076\" data-end=\"1085\">B priedas<\/em> nurodo, kad <strong data-start=\"1100\" data-end=\"1118\">n\u0117ra oro nuot\u0117kio<\/strong> atliekant aspiracin\u012f bandym\u0105 gali atsirasti arba suma\u017e\u0117ti vakuumo sl\u0117gis. \u0160ie kriterijai u\u017etikrina \u0161virk\u0161to barjero vientisum\u0105 ir saug\u0173 klinikin\u012f naudojim\u0105.<\/p><h3>St\u016bmoklio veikimo j\u0117ga<\/h3><p data-start=\"1269\" data-end=\"1702\">ISO 7886-1 rekomenduoja patikrinti j\u0117gas, reikalingas st\u016bmoklio jud\u0117jimui inicijuoti ir i\u0161laikyti, nes nuo to priklauso \u0161virk\u0161to tinkamumas naudoti ir doz\u0117s kontrol\u0117. <em data-start=\"1457\" data-end=\"1466\">E priedas<\/em> pateikia metod\u0105, skirt\u0105 \u012fvertinti <strong data-start=\"1500\" data-end=\"1532\">atsipalaiduoti ir slysti j\u0117gomis.<\/strong> naudojant mechanin\u0119 bandym\u0173 sistem\u0105. Nors \u0161is bandymas yra informatyvus, o ne privalomas, jis atlieka labai svarb\u0173 vaidmen\u012f u\u017etikrinant nuosekl\u0173 ir naudotojui patog\u0173 veikim\u0105.<\/p><h3>St\u016bmoklio montavimas ir laikymas<\/h3><p>St\u016bmoklio kam\u0161tis turi gerai priglusti prie cilindro. Kad tai patvirtintum\u0117te, \u0161virk\u0161tas pripildomas iki vardin\u0117s talpos ir laikomas vertikaliai - tiek vertikaliai, tiek apverstas. Bet kurioje pad\u0117tyje st\u016bmoklis turi <strong data-start=\"1945\" data-end=\"1979\">nejuda d\u0117l savo svorio.<\/strong> arba tik vandens svoris. \u0160is reikalavimas apsaugo nuo nety\u010dinio jud\u0117jimo, d\u0117l kurio gali atsirasti dozavimo klaid\u0173 arba nuot\u0117kio.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f56e8f6 e-flex e-con-boxed e-con e-parent\" data-id=\"f56e8f6\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2f8a27b elementor-widget elementor-widget-heading\" data-id=\"2f8a27b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0160virk\u0161to funkcionalumo testavimas: Pagrindiniai parametrai ir bandymo metodai<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5563edc e-con-full e-flex e-con e-child\" data-id=\"5563edc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-3c81440 e-con-full e-flex e-con e-child\" data-id=\"3c81440\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dcd03b3 elementor-widget elementor-widget-text-editor\" data-id=\"dcd03b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Atsipalaidavimo ir slydimo j\u0117gos bandymas<\/h3><p data-start=\"1844\" data-end=\"2038\"><strong data-start=\"1844\" data-end=\"1855\">E priedas<\/strong> ISO 7886-1 nurodo metod\u0105, kaip nustatyti <em data-start=\"1911\" data-end=\"1924\">i\u0161silaisvinti<\/em> ir <em data-start=\"1929\" data-end=\"1942\">slydimo j\u0117ga<\/em> reikalingas st\u016bmokliui valdyti. \u0160ios j\u0117gos daro \u012ftak\u0105 naudotojo patir\u010diai ir dozavimo kontrolei.<\/p><ul><li data-start=\"2042\" data-end=\"2112\"><a href=\"https:\/\/www.syringetest.com\/lt\/break-loose-and-glide-force-testing\/\"><strong data-start=\"2042\" data-end=\"2063\">Atsilaisvinimo j\u0117ga<\/strong><\/a> yra pradin\u0117 j\u0117ga, reikalinga st\u016bmokliui pajudinti.<\/li><li data-start=\"2115\" data-end=\"2188\"><a href=\"https:\/\/www.syringetest.com\/lt\/break-loose-and-glide-force-testing\/\"><strong data-start=\"2115\" data-end=\"2130\">Slydimo j\u0117ga<\/strong><\/a> yra vidutin\u0117 j\u0117ga, reikalinga st\u016bmoklio jud\u0117jimui t\u0119sti.<\/li><\/ul><p data-start=\"2190\" data-end=\"2217\"><strong data-start=\"2190\" data-end=\"2217\">Svarbiausi bandym\u0173 metodo aspektai:<\/strong><\/p><ul><li data-start=\"2220\" data-end=\"2329\">Naudokite mechanin\u0119 testavimo sistem\u0105 (pvz., \u2019Cell Instruments\u2019 <strong data-start=\"2277\" data-end=\"2309\">MST-01 Medicinini\u0173 \u0161virk\u0161t\u0173 testeris<\/strong>) 100 \u00b1 5 mm\/min.<\/li><li data-start=\"2332\" data-end=\"2369\">Pripildykite \u0161virk\u0161t\u0105 23 \u00b1 5 \u00b0C temperat\u016bros vandeniu.<\/li><li data-start=\"2372\" data-end=\"2457\">Prijunkite \u0161virk\u0161t\u0105 prie vamzdelio ir i\u0161stumkite vanden\u012f, kol st\u016bmoklis pasieks vardin\u0119 \u017eym\u0119.<\/li><li data-start=\"2460\" data-end=\"2467\">\u012era\u0161as:<ul><li data-start=\"2472\" data-end=\"2499\">Pradin\u0117 jud\u0117jimo j\u0117ga (f\u209b)<\/li><li data-start=\"2504\" data-end=\"2525\">Vidutin\u0117 va\u017eiavimo j\u0117ga (F)<\/li><li data-start=\"2530\" data-end=\"2558\">Did\u017eiausia pasiprie\u0161inimo j\u0117ga (Fmax)<\/li><\/ul><\/li><\/ul><p data-start=\"2560\" data-end=\"2677\"><em data-start=\"2560\" data-end=\"2677\">Nuoseklus slydimas u\u017etikrina injekcijos sklandum\u0105 ir naudotojo komfort\u0105, tod\u0117l tai yra labai svarbus kokyb\u0117s kriterijus.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e0368a elementor-widget elementor-widget-image\" data-id=\"8e0368a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"546\" height=\"719\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\" class=\"attachment-large size-large wp-image-613\" alt=\"ISO 7886-1 E priedas\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp 546w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E-228x300.webp 228w\" sizes=\"(max-width: 546px) 100vw, 546px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e0724ff elementor-widget elementor-widget-text-editor\" data-id=\"e0724ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>\u0160virk\u0161to skys\u010dio nuot\u0117kio aptikimas (suspaudus)<\/h3><p data-start=\"2741\" data-end=\"2896\"><strong data-start=\"2741\" data-end=\"2752\">D priedas<\/strong> pateikiamas metodas, skirtas aptikti <a href=\"https:\/\/www.syringetest.com\/lt\/syringe-liquid-leakage-test-for-closure-system\/\"><strong data-start=\"2781\" data-end=\"2799\">skys\u010dio nutek\u0117jimas<\/strong><\/a> po to, kai <strong data-start=\"2809\" data-end=\"2833\">st\u016bmoklio kam\u0161\u010dio sandariklis<\/strong> suspaudimo metu - labai svarbus \u0161virk\u0161to patikimumo rodiklis.<\/p><p data-start=\"2898\" data-end=\"2915\"><strong data-start=\"2898\" data-end=\"2915\">Bandymo procesas:<\/strong><\/p><ul><li data-start=\"2918\" data-end=\"2985\">Pripildykite \u0161virk\u0161t\u0105 distiliuotu vandeniu (18-28 \u00b0C) iki vardinio t\u016brio.<\/li><li data-start=\"2988\" data-end=\"3049\">U\u017edarykite \u0161virk\u0161to antgal\u012f naudodami ISO 80369-7 standart\u0105 atitinkan\u010dias jungtis.<\/li><li data-start=\"3052\" data-end=\"3098\">St\u016bmokl\u012f veikite \u0161onine j\u0117ga (0,25-3 N).<\/li><li data-start=\"3101\" data-end=\"3163\">Naudokite a\u0161in\u0119 j\u0117g\u0105, kad susidaryt\u0173 vidinis sl\u0117gis (200-300 kPa).<\/li><li data-start=\"3166\" data-end=\"3193\">I\u0161laikykite 30-35 sekundes.<\/li><li data-start=\"3196\" data-end=\"3238\">Ap\u017ei\u016br\u0117kite, ar i\u0161 cilindro nei\u0161b\u0117ga skystis.<\/li><\/ul><p data-start=\"3240\" data-end=\"3361\">\"Cell Instruments\" si\u016blo <strong data-start=\"3268\" data-end=\"3298\">SLT-02 \u0161virk\u0161t\u0173 nuot\u0117kio testeris<\/strong>, idealiai tinka tiksliai sl\u0117gio kontrolei ir steb\u0117jimui realiuoju laiku.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2bd0256 e-con-full e-flex e-con e-child\" data-id=\"2bd0256\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bc3f908 elementor-widget elementor-widget-text-editor\" data-id=\"bc3f908\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>\u0160virk\u0161to oro nuot\u0117kio aptikimas (aspiracijos metu)<\/h3><p data-start=\"3422\" data-end=\"3549\"><strong data-start=\"3422\" data-end=\"3433\">B priedas<\/strong> apibr\u0117\u017eia proced\u016bras, susijusias su <strong data-start=\"3457\" data-end=\"3490\">\u0161virk\u0161to oro nuot\u0117kio aptikimas<\/strong> ir patikrinti, ar st\u016bmoklio kam\u0161tis i\u0161laikomas aspiracijos metu.<\/p><p data-start=\"3551\" data-end=\"3565\"><strong data-start=\"3551\" data-end=\"3565\">Proced\u016bra:<\/strong><\/p><ul><li data-start=\"3568\" data-end=\"3635\">I\u0161 dalies u\u017epildykite \u0161virk\u0161t\u0105 vandeniu ir patraukite st\u016bmokl\u012f iki vardin\u0117s \u017eym\u0117s.<\/li><li data-start=\"3638\" data-end=\"3690\">U\u017efiksuokite st\u016bmokl\u012f ir prijunkite \u0161virk\u0161t\u0105 prie vakuumin\u0117s sistemos.<\/li><li data-start=\"3693\" data-end=\"3736\">Sukurkite 88 kPa ma\u017eesn\u012f u\u017e atmosferos sl\u0117g\u012f.<\/li><li data-start=\"3739\" data-end=\"3762\">Steb\u0117kite 60 sekund\u017ei\u0173:<ul><li data-start=\"3767\" data-end=\"3810\">Manometro sl\u0117gio kritimas (rodo nuot\u0117k\u012f)<\/li><li data-start=\"3815\" data-end=\"3848\">St\u016bmoklio atsiskyrimas arba nestabilumas<\/li><\/ul><\/li><\/ul><p data-start=\"3850\" data-end=\"3955\">Sandarumas u\u017etikrina dozavimo tikslum\u0105 ir apsaugo nuo u\u017eter\u0161imo, tod\u0117l \u0161is bandymas yra labai svarbus saugiam naudojimui.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a0b40de elementor-widget elementor-widget-image\" data-id=\"a0b40de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"694\" height=\"570\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B.webp\" class=\"attachment-large size-large wp-image-614\" alt=\"ISO 7886-1 B priedas\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B.webp 694w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B-300x246.webp 300w\" sizes=\"(max-width: 694px) 100vw, 694px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a4c9f2a e-flex e-con-boxed e-con e-parent\" data-id=\"a4c9f2a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-032dedc elementor-widget elementor-widget-heading\" data-id=\"032dedc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Tinkamos \u0161virk\u0161t\u0173 bandymo \u012frangos pasirinkimas<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-02a9ca0 e-grid e-con-full e-con e-child\" data-id=\"02a9ca0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8858447 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"8858447\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img decoding=\"async\" width=\"1698\" height=\"2560\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp\" class=\"attachment-full size-full wp-image-884\" alt=\"SLT-02 \u0160virk\u0161t\u0173 nuot\u0117kio testas\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp 1698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-199x300.webp 199w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-679x1024.webp 679w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-768x1158.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1019x1536.webp 1019w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1358x2048.webp 1358w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-8x12.webp 8w\" sizes=\"(max-width: 1698px) 100vw, 1698px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">SLT-02 \u0161virk\u0161t\u0173 nuot\u0117kio testeris<\/h3><p class=\"elementor-image-box-description\">\u0160is prietaisas tiksliai kontroliuoja \u0161virk\u0161to vakuum\u0105, tod\u0117l galima tiksliai steb\u0117ti sl\u0117gio poky\u010dius ir st\u016bmoklio vientisum\u0105. Sukonstruotas su ISO 80369-7 standartu suderinamomis jungtimis ir saugiais u\u017espaudimo mechanizmais, SLT-01 u\u017etikrina i\u0161sam\u0173 oro sandarumo ir st\u016bmoklio kam\u0161\u010dio i\u0161laikymo \u012fvertinim\u0105.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84ddc7f elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"84ddc7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img loading=\"lazy\" decoding=\"async\" width=\"1285\" height=\"2560\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-scaled.webp\" class=\"attachment-full size-full wp-image-889\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-scaled.webp 1285w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-151x300.webp 151w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-514x1024.webp 514w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-768x1530.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-771x1536.webp 771w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-1028x2048.webp 1028w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-6x12.webp 6w\" sizes=\"(max-width: 1285px) 100vw, 1285px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">MST-01 Medicinini\u0173 \u0161virk\u0161t\u0173 testeris<\/h3><p class=\"elementor-image-box-description\">Jame naudojama labai tiksli mechanin\u0117 sistema, skirta matuoti atsipalaidavimo ir slydimo j\u0117gas i\u0161stumiant skyst\u012f. MST-01 leid\u017eia gamintojams kiekybi\u0161kai \u012fvertinti inicijavimo ir jud\u0117jimo pasiprie\u0161inim\u0105, tod\u0117l pateikia svarbius duomenis, u\u017etikrinan\u010dius skland\u0173 ir nuosekl\u0173 st\u016bmoklio jud\u0117jim\u0105 - tai labai svarbu saugiam ir patogiam jud\u0117jimui.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bda0648 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"bda0648\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img loading=\"lazy\" decoding=\"async\" width=\"1164\" height=\"2560\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-scaled.webp\" class=\"attachment-full size-full wp-image-885\" alt=\"SPPT-01 \u0161virk\u0161to teigiamo sl\u0117gio sandarumo testeris\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-scaled.webp 1164w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-136x300.webp 136w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-465x1024.webp 465w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-768x1690.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-698x1536.webp 698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-931x2048.webp 931w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-5x12.webp 5w\" sizes=\"(max-width: 1164px) 100vw, 1164px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">SPPT-01 \u0160virk\u0161t\u0173 sandarumo testeris<\/h3><p class=\"elementor-image-box-description\">\u0160is prietaisas imituoja sl\u0117g\u012f \u0161virk\u0161to cilindre, o st\u016bmokliui tenka \u0161onin\u0117s ir a\u0161in\u0117s apkrovos, taip tiksliai atkartojant klinikinio naudojimo s\u0105lygas. SSPT-01 sukurtas taip, kad juo galima aptikti net ir ne\u017eymius sandarinimo gedimus, o tai padeda gamintojams patikrinti gaminio patikimum\u0105 ir atitikt\u012f grie\u017etiems saugos standartams.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8b0f6e0 e-flex e-con-boxed e-con e-parent\" data-id=\"8b0f6e0\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11b99fc elementor-widget elementor-widget-heading\" data-id=\"11b99fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kod\u0117l ISO 7886-1 atitiktis yra svarbi<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-263368c elementor-widget elementor-widget-text-editor\" data-id=\"263368c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4571\" data-end=\"4657\">ISO 7886-1 standarto laikymasis u\u017etikrina, kad \u0161virk\u0161tai:<\/p><ul><li data-start=\"4660\" data-end=\"4682\">Tikslios doz\u0117s<\/li><li data-start=\"4685\" data-end=\"4713\">yra saug\u016bs ir lengvai valdomi.<\/li><li data-start=\"4716\" data-end=\"4740\">Naudojimo metu i\u0161lieka sandar\u016bs<\/li><li data-start=\"4743\" data-end=\"4789\">atitikti pasaulinius reguliavimo ir eksporto reikalavimus<\/li><\/ul><p data-start=\"4791\" data-end=\"4910\">Nepaisydami tinkamo <strong data-start=\"4809\" data-end=\"4842\">\u0161virk\u0161to funkcionalumo testavimas<\/strong> gali lemti produkt\u0173 at\u0161aukim\u0105, teis\u0117s akt\u0173 nustatytas nuobaudas arba \u017eal\u0105 pacientams.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-be52d1e e-grid e-con-full e-con e-parent\" data-id=\"be52d1e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c72d800 elementor-widget elementor-widget-image\" data-id=\"c72d800\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c83f8a8 e-con-full e-flex e-con e-child\" data-id=\"c83f8a8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09b28d1 elementor-widget elementor-widget-heading\" data-id=\"09b28d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kod\u0117l verta rinktis <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c87e7b1 elementor-widget elementor-widget-text-editor\" data-id=\"c87e7b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4917\" data-end=\"5240\">Supratimas ir taikymas <strong data-start=\"4961\" data-end=\"4975\">ISO 7886-1<\/strong> bandym\u0173 metodai yra b\u016btini bet kuriai \u012fmonei, u\u017esiiman\u010diai \u0161virk\u0161t\u0173 gamyba ar kokyb\u0117s kontrole. I\u0161 <strong data-start=\"5077\" data-end=\"5116\">atsipalaidavimo ir slydimo j\u0117gos bandymai<\/strong> \u012f <strong data-start=\"5120\" data-end=\"5153\">oro ir skys\u010di\u0173 nuot\u0117kio aptikimas<\/strong>, kiekvienas bandymas atlieka tam tikr\u0105 vaidmen\u012f u\u017etikrinant gaminio patikimum\u0105 ir naudotojo saug\u0105.<\/p><p data-start=\"5242\" data-end=\"5537\"><strong>Syringetest.com<\/strong> teikia pa\u017eangias <strong data-start=\"5281\" data-end=\"5310\">\u0161virk\u0161t\u0173 bandymo \u012franga<\/strong> sukurta siekiant u\u017etikrinti visi\u0161k\u0105 atitikt\u012f ir supaprastinti QC darbo eig\u0105. Jei norite atnaujinti savo \u0161virk\u0161t\u0173 patvirtinimo proces\u0105 arba pagerinti bandym\u0173 tikslum\u0105, susisiekite su mumis ir su\u017einokite, kaip m\u016bs\u0173 prietaisai gali pad\u0117ti atitikti j\u016bs\u0173 standartus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6924b06 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"6924b06\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/lt\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Susisiekite su mumis<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 7886-1 Syringe Functionality Testing Standard ISO 7886-1 is the internationally recognized standard that defines the performance and testing requirements for sterile hypodermic syringes for single use, intended for manual operation. This standard plays a vital role in syringe quality control, ensuring functional safety and patient protection. Quality control engineers and regulatory specialists rely on [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":603,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-608","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/pages\/608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/comments?post=608"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/pages\/608\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/pages\/603"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/media?parent=608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}