{"id":173,"date":"2025-04-30T03:56:30","date_gmt":"2025-04-30T03:56:30","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=173"},"modified":"2026-05-19T08:03:46","modified_gmt":"2026-05-19T08:03:46","slug":"front-end-breakage-resistance-iso-11040-4-annex-c2","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/lt\/front-end-breakage-resistance-iso-11040-4-annex-c2","title":{"rendered":"\u0160virk\u0161to priekin\u0117s dalies atsparumo l\u016b\u017eiui bandymas"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"173\" class=\"elementor elementor-173\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0877670 e-flex e-con-boxed e-con e-parent\" data-id=\"0877670\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b2fa34d elementor-widget elementor-widget-heading\" data-id=\"b2fa34d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">\u0160virk\u0161to priekin\u0117s dalies atsparumo l\u016b\u017eiui bandymas<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9e27540 elementor-widget elementor-widget-text-editor\" data-id=\"9e27540\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Svetain\u0117 <strong>priekin\u0117s dalies atsparumas l\u016b\u017eiams<\/strong> \u0161virk\u0161to kokyb\u0117 yra labai svarbus farmacijos pakuo\u010di\u0173 kokyb\u0117s parametras. \u0160is po\u017eymis u\u017etikrina, kad \u0161virk\u0161tas atlaikyt\u0173 \u0161onines apkrovas j\u012f tvarkant, gabenant ar vartojant ir nesugest\u0173. Gamintojams ir kokyb\u0117s kontrol\u0117s specialistams \u0161io atsparumo supratimas ir tinkamas testavimas yra labai svarbus siekiant u\u017etikrinti pacient\u0173 saug\u0105 ir produkto atitikt\u012f reikalavimams.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f441832 e-flex e-con-boxed e-con e-parent\" data-id=\"f441832\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5c84ac0 elementor-widget elementor-widget-heading\" data-id=\"5c84ac0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Atsipalaidavimo ir slydimo j\u0117gos bandym\u0173 svarba<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-88abe9f elementor-widget elementor-widget-text-editor\" data-id=\"88abe9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Atsparumas priekinio galo l\u016b\u017eimui yra ne tik teis\u0117s akt\u0173 reikalavimas - tai pacient\u0173 sveikatos ir \u0161virk\u0161to veikimo apsauga. Silpni stikliniai antgaliai gali sudu\u017eti klinikinio naudojimo metu, tod\u0117l kyla pavojus susi\u017eeisti, u\u017eter\u0161ti ar padaryti dozavimo klaid\u0173. Vis\u0173 pirma, <a href=\"https:\/\/www.syringetest.com\/lt\/standartai\/iso-11040-4\/\"><strong>ISO 11040-4<\/strong><\/a> ir jos normatyvin\u0117 <strong>C2 priedas<\/strong> apibr\u0117\u017eti standartinius metodus ir reikalavimus, taikomus atliekant \u0161\u012f svarb\u0173 bandym\u0105 su <strong>stiklin\u0117s statin\u0117s injekciniams preparatams<\/strong>. \u012egyvendinant <strong>ISO 11040-4 bandymai<\/strong>, gamintojai gali:<\/p><ul><li>anksti aptikti konstrukcijos ar med\u017eiag\u0173 tr\u016bkumus.<\/li><li>Stiprinti strukt\u016brin\u012f vientisum\u0105<\/li><li>U\u017etikrinkite atitikt\u012f ir klient\u0173 pasitik\u0117jim\u0105<\/li><\/ul><p><strong>Syringetest.com testavimo sistemos<\/strong> \u012fgalina laboratorijas laikytis pasaulini\u0173 standart\u0173 ir tuo pa\u010diu metu gauti veiksmingus, pakartojamus rezultatus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-316973d e-flex e-con-boxed e-con e-parent\" data-id=\"316973d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3e8b6ba elementor-widget elementor-widget-heading\" data-id=\"3e8b6ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Bandymai ir C2 priedas<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b275e4 elementor-widget elementor-widget-text-editor\" data-id=\"8b275e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>ISO 11040-4 apra\u0161o specifikacijas, susijusias su <strong>i\u0161 anksto sterilizuoti stikliniai \u0161virk\u0161tai<\/strong> ir <strong>\u0161virk\u0161t\u0173 statin\u0117s<\/strong>u\u017etikrinant, kad kiekvienas komponentas atitikt\u0173 farmacijos saugos reikalavimus. <strong>C2 priedas<\/strong> daugiausia d\u0117mesio skiria <strong>priekin\u0117s dalies atsparumo l\u016b\u017eiui bandymas<\/strong>, mechaninis bandymas, imituojantis reali\u0105 apkrov\u0105 pa\u017eeid\u017eiamiausiai \u0161virk\u0161to daliai - priekinei daliai.<\/p><p>Pagal standart\u0105:<\/p><ul><li>Atliekant test\u0105 \u012fvertinama <em>did\u017eiausia j\u0117ga<\/em> \u0161virk\u0161to priekin\u0117 dalis gali atlaikyti prie\u0161 l\u016b\u017edama.<\/li><li>\u0160virk\u0161t\u0173 statin\u0117s (su mazgu arba be jo) bandomos naudojant <strong>universali tempimo ir gniu\u017edymo bandymo ma\u0161ina<\/strong>.<\/li><li>A <strong>ner\u016bdijan\u010dio plieno me\u0161ker\u0117 ir laikiklis<\/strong> nustatymas imituoja \u0161onin\u0119 apkrov\u0105, spaud\u017eiant 2 mm atstumu nuo \u0161virk\u0161to antgalio.<\/li><\/ul><p>\u0160is bandymas privalomas ISO 11040-4 standarto 2, 3 ir 5 paveiksluose pavaizduotoms stiklini\u0173 \u0161virk\u0161t\u0173 konstrukcijoms, kurios atitinka \u012fprastus statin\u0117s formatus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a250905 elementor-widget elementor-widget-image\" data-id=\"a250905\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1190\" height=\"300\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2.webp\" class=\"attachment-full size-full wp-image-192\" alt=\"\u0160virk\u0161to priekin\u0117s dalies atsparumas l\u016b\u017eiui - ISO 11040-4 priedas C2\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2.webp 1190w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2-300x76.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2-1024x258.webp 1024w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2-768x194.webp 768w\" sizes=\"(max-width: 1190px) 100vw, 1190px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c56e688 e-flex e-con-boxed e-con e-parent\" data-id=\"c56e688\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-37e25ec elementor-widget elementor-widget-heading\" data-id=\"37e25ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0160virk\u0161t\u0173 bandymo \u012franga ir s\u0105rankos reikalavimai<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dee37ee elementor-widget elementor-widget-text-editor\" data-id=\"dee37ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nor\u0117dami atlikti <strong>priekin\u0117s dalies atsparumo l\u016b\u017eiui bandymas<\/strong>, reikalavimus atitinkan\u010dioje laboratorijoje turi b\u016bti \u012frengta \u0161i \u012franga:<\/p><ul><li><strong>Universali tempimo ir gniu\u017edymo bandymo ma\u0161ina<\/strong>, galintis i\u0161laikyti <strong>25 mm\/min<\/strong> krovimo greitis.<\/li><li>Apkrovos elementas, pritaikytas matuoti l\u016b\u017eio j\u0117gas, paprastai <strong>niutonai (N)<\/strong>.<\/li><li><strong>Didel\u0117s spartos m\u0117gini\u0173 \u0117mimo galimyb\u0117<\/strong> (pageidautina 500 Hz, kai matuojama did\u017eiausia j\u0117ga).<\/li><li><strong>Adapteri\u0173 rinkinys ir tvirtinimo \u012ftaisai<\/strong> atitinka \u0161virk\u0161to geometrij\u0105.<\/li><li><strong>Saugus nuo stiklo laikiklis ir apsauginis gaubtas<\/strong> kad nesusi\u017eeistum\u0117te d\u0117l sutrup\u0117jusi\u0173 dali\u0173.<\/li><\/ul><p>Ma\u0161inos s\u0105ranka, bandymo greitis ir apkrovos ta\u0161ko tikslumas (2 mm nuo antgalio) turi didel\u0119 \u012ftak\u0105 rezultat\u0173 patikimumui.<\/p><p><strong>Syringetest.com \u0161virk\u0161t\u0173 testavimo sprendimai<\/strong> integruotos i\u0161maniosios programin\u0117s \u012frangos s\u0105sajos, reguliuojami laikikliai ir tiksl\u016bs jutikliai, visi\u0161kai atitinkantys ISO 11040-4 reikalavimus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f793b7c e-flex e-con-boxed e-con e-parent\" data-id=\"f793b7c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e082694 elementor-widget elementor-widget-heading\" data-id=\"e082694\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kaip atlikti priekin\u0117s dalies atsparumo l\u016b\u017eiui bandym\u0105<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d2248d3 elementor-widget elementor-widget-text-editor\" data-id=\"d2248d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Atlikite \u0161iuos veiksmus, kad tiksliai <strong>ISO 11040-4 priedo C2 \u0161virk\u0161t\u0173 bandymai<\/strong>:<\/p><h3>1. Paruo\u0161kite aparat\u0105:<\/h3><ul><li>Patikrinkite adapterio suderinamum\u0105 ir vientisum\u0105.<\/li><li>Patikrinkite programin\u0117s \u012frangos konfig\u016bracij\u0105 ir apsauginius gaubtus.<\/li><\/ul><h3>2. \u012ediekite pavyzd\u012f:<\/h3><ul><li>\u012ed\u0117kite \u0161virk\u0161to cilindr\u0105 \u012f laikikl\u012f.<\/li><li>\u012esitikinkite, kad priekin\u0117 dalis tiksliai sutampa su krovimo kai\u0161\u010diu.<\/li><\/ul><h3>3. Atlikite test\u0105:<\/h3><ul><li>Nustatykite 25 mm\/min greit\u012f.<\/li><li>Prad\u0117kite spausti, kol l\u016b\u0161 statin\u0117s priekin\u0117 dalis.<\/li><li>\u012era\u0161ykite <em>did\u017eiausia j\u0117ga l\u016b\u017eio metu<\/em>.<\/li><\/ul><h3>4. Veiksmai po testo:<\/h3><ul><li>Saugiai pa\u0161alinkite ir i\u0161meskite sudu\u017eus\u012f stikl\u0105.<\/li><li>Prie\u0161 kit\u0105 bandym\u0105 i\u0161valykite ir i\u0161 naujo nustatykite armat\u016br\u0105.<\/li><\/ul><h3>5. Rezultat\u0173 ai\u0161kinimas ir dokumentavimas<\/h3><p>Bandymas laikomas galiojan\u010diu, kai nurodytomis s\u0105lygomis priekin\u0117je dalyje \u012fvyksta l\u016b\u017eis. Bandymo ataskaitoje turi b\u016bti nurodyta:<\/p><ol><li>Taikomas bandymo greitis (mm\/min)<\/li><li>J\u0117gos veikimo atstumas (\u22482 mm nuo antgalio)<\/li><li>Did\u017eiausia tr\u016bkio j\u0117ga (N)<\/li><li>Tiriam\u0173j\u0173 m\u0117gini\u0173 skai\u010dius<\/li><li>Bet kokios anomalijos ar nukrypimai<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e3da57f e-grid e-con-full e-con e-parent\" data-id=\"e3da57f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-389299e elementor-widget elementor-widget-image\" data-id=\"389299e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-18dd657 e-con-full e-flex e-con e-child\" data-id=\"18dd657\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-555d851 elementor-widget elementor-widget-heading\" data-id=\"555d851\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kod\u0117l verta rinktis <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-88e1f19 elementor-widget elementor-widget-text-editor\" data-id=\"88e1f19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Supratimas ir taikymas <strong>priekin\u0117s dalies atsparumas l\u016b\u017eiams<\/strong> testavimas, kaip apibr\u0117\u017eta <strong><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> C2 priedas<\/strong> u\u017etikrina, kad \u0161virk\u0161t\u0173 gaminiai atitikt\u0173 grie\u017etus saugos l\u016bkes\u010dius. Nesvarbu, ar esate gamintojas, teis\u0117saugos pareig\u016bnas, ar kokyb\u0117s kontrol\u0117s in\u017einierius, tiksl\u016bs ir reikalavimus atitinkantys bandymai yra b\u016btini.<\/p><p><strong>Syringetest.com<\/strong> teikia <strong>patikimi, standartus atitinkantys \u0161virk\u0161t\u0173 testavimo sprendimai<\/strong> kurie supaprastina darbo eig\u0105 ir pagerina gaminio na\u0161um\u0105. Susipa\u017einkite su visu m\u016bs\u0173 medicinini\u0173 pakuo\u010di\u0173 bandymo prietais\u0173 asortimentu ir pagerinkite savo laboratorijos galimybes jau \u0161iandien.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a51db32 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"a51db32\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/lt\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Susisiekite su mumis<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Syringe Front End Breakage Resistance Testing The front end breakage resistance of a syringe is a critical quality parameter in pharmaceutical packaging. This attribute ensures that the syringe can withstand side loads during handling, transportation, or administration without failure. For manufacturers and quality control professionals, understanding and properly testing this resistance is essential to patient [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-173","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/pages\/173","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/comments?post=173"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/pages\/173\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/lt\/wp-json\/wp\/v2\/media?parent=173"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}