{"id":878,"date":"2026-05-08T04:11:57","date_gmt":"2026-05-08T04:11:57","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=878"},"modified":"2026-05-19T07:20:57","modified_gmt":"2026-05-19T07:20:57","slug":"iso-8537","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/it\/standards\/iso-8537","title":{"rendered":"ISO 8537"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"878\" class=\"elementor elementor-878\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-48d9594 e-flex e-con-boxed e-con e-parent\" data-id=\"48d9594\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-85f9391 elementor-widget elementor-widget-heading\" data-id=\"85f9391\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 8537<br><small>Siringhe sterili monouso, con o senza ago, per l'insulina<\/small><\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aac7d95 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"aac7d95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"356\" data-end=\"891\">Le siringhe sterili per insulina richiedono prestazioni funzionali precise per garantire la sicurezza del paziente, l'accuratezza del dosaggio e la somministrazione affidabile del farmaco. <strong data-start=\"491\" data-end=\"503\">ISO 8537<\/strong> specifica i requisiti e i corrispondenti metodi di prova per le siringhe sterili monouso, con o senza ago, destinate all'iniezione di insulina. Lo standard si concentra su caratteristiche critiche quali la resistenza alle perdite, la forza di azionamento del pistone, lo spazio morto e l'integrit\u00e0 delle connessioni tra i componenti della siringa, tra cui la <strong data-start=\"831\" data-end=\"890\">ugello, mozzo, ago, canna, pistone e tappo in gomma<\/strong>.<\/p><p data-start=\"893\" data-end=\"1221\">Per i produttori di siringhe e i laboratori di controllo qualit\u00e0, la conformit\u00e0 a <strong data-start=\"969\" data-end=\"981\">ISO 8537<\/strong> aiuta a verificare la consistenza del prodotto, a ridurre i rischi di perdita e a migliorare le prestazioni di iniettabilit\u00e0 durante l'uso clinico. I moderni sistemi di analisi supportano anche l'acquisizione automatica dei dati, l'analisi della ripetibilit\u00e0 e la documentazione della qualit\u00e0 tracciabile.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-34af957 e-flex e-con-boxed e-con e-parent\" data-id=\"34af957\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dc7d0ed elementor-widget elementor-widget-heading\" data-id=\"dc7d0ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 8537 Requisiti per il test delle prestazioni delle siringhe<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-413ec4f elementor-widget elementor-widget-text-editor\" data-id=\"413ec4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1286\" data-end=\"1440\">La norma ISO 8537 stabilisce diverse procedure di verifica per valutare le prestazioni meccaniche e di tenuta delle siringhe sterili da insulina. Lo standard copre:<\/p><ul data-start=\"1442\" data-end=\"1681\"><li data-section-id=\"1lghe2x\" data-start=\"1442\" data-end=\"1478\">Prestazioni di tenuta del pistone della siringa<\/li><li data-section-id=\"km50lt\" data-start=\"1479\" data-end=\"1503\">Resistenza alle perdite d'aria<\/li><li data-section-id=\"413t8n\" data-start=\"1504\" data-end=\"1531\">Resistenza alla perdita di liquidi<\/li><li data-section-id=\"vzeopp\" data-start=\"1532\" data-end=\"1558\">Determinazione dello spazio morto<\/li><li data-section-id=\"87u2zy\" data-start=\"1559\" data-end=\"1596\">Test di rottura e forza di scorrimento<\/li><li data-section-id=\"1r4pkcu\" data-start=\"1597\" data-end=\"1634\">Integrit\u00e0 del collegamento tra ago e mozzo<\/li><li data-section-id=\"1cxbo49\" data-start=\"1635\" data-end=\"1681\">Prestazioni di siringabilit\u00e0 e iniettabilit\u00e0<\/li><\/ul><p data-start=\"1683\" data-end=\"1855\">Queste valutazioni assicurano che la siringa mantenga la capacit\u00e0 di tenuta durante l'aspirazione e l'iniezione, garantendo al contempo un movimento fluido dello stantuffo e un'erogazione accurata del dosaggio.<\/p><p data-start=\"1857\" data-end=\"1907\">Per i produttori, questi test influenzano direttamente:<\/p><ul data-start=\"1909\" data-end=\"2019\"><li data-section-id=\"1kgf4fz\" data-start=\"1909\" data-end=\"1925\">Sicurezza del prodotto<\/li><li data-section-id=\"fw7gsx\" data-start=\"1926\" data-end=\"1945\">Comfort di iniezione<\/li><li data-section-id=\"4fq85f\" data-start=\"1946\" data-end=\"1962\">Precisione della dose<\/li><li data-section-id=\"1yh82kt\" data-start=\"1963\" data-end=\"1986\">Conformit\u00e0 normativa<\/li><li data-section-id=\"1lk2gtk\" data-start=\"1987\" data-end=\"2019\">Coerenza della qualit\u00e0 di produzione<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-38a36c9 e-flex e-con-boxed e-con e-parent\" data-id=\"38a36c9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ba9a815 elementor-widget elementor-widget-heading\" data-id=\"ba9a815\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test di siringabilit\u00e0 e iniettabilit\u00e0 secondo ISO 8537<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-89fad34 e-con-full e-flex e-con e-child\" data-id=\"89fad34\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a2a949 elementor-widget elementor-widget-text-editor\" data-id=\"3a2a949\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2090\" data-end=\"2310\">Il <strong data-start=\"2094\" data-end=\"2135\">test di siringabilit\u00e0 e iniettabilit\u00e0<\/strong> valuta le caratteristiche operative del pistone della siringa durante l'erogazione del fluido. L'allegato C della norma ISO 8537 definisce la determinazione delle forze necessarie per azionare il pistone.<\/p><p data-start=\"2312\" data-end=\"2333\">Durante la procedura:<\/p><ol data-start=\"2335\" data-end=\"2663\"><li data-section-id=\"200s8h\" data-start=\"2335\" data-end=\"2408\">La siringa viene riempita fino a 50% della capacit\u00e0 nominale con acqua distillata.<\/li><li data-section-id=\"mdao9q\" data-start=\"2409\" data-end=\"2478\">La siringa \u00e8 fissata verticalmente con l'ago rivolto verso il basso.<\/li><li data-section-id=\"l6yed3\" data-start=\"2479\" data-end=\"2533\">Al pistone viene applicata una forza assiale controllata.<\/li><li data-section-id=\"16cx4j2\" data-start=\"2534\" data-end=\"2596\">Viene registrata la forza necessaria per avviare il movimento del pistone.<\/li><li data-section-id=\"7rurb5\" data-start=\"2597\" data-end=\"2663\">Si misura anche la forza continua necessaria per sostenere il movimento.<\/li><\/ol><p data-start=\"2665\" data-end=\"2714\">Questo processo determina due parametri importanti:<\/p><ul data-start=\"2716\" data-end=\"2866\"><li data-section-id=\"fbhnrm\" data-start=\"2716\" data-end=\"2791\"><strong data-start=\"2718\" data-end=\"2739\">Forza di rottura<\/strong> - la forza iniziale necessaria per avviare il movimento del pistone<\/li><li data-section-id=\"1wcea99\" data-start=\"2792\" data-end=\"2866\"><strong data-start=\"2794\" data-end=\"2809\">Forza di scorrimento<\/strong> - la forza continua necessaria per mantenere la corsa del pistone<\/li><\/ul><p data-start=\"2868\" data-end=\"3028\">Un'eccessiva forza di distacco pu\u00f2 causare una scomoda operazione di iniezione, mentre una forza di scorrimento instabile pu\u00f2 influire negativamente sul controllo dell'iniezione e sull'accuratezza del dosaggio.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9edb986 elementor-widget elementor-widget-image\" data-id=\"9edb986\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"982\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-834x1024.webp\" class=\"attachment-large size-large wp-image-891\" alt=\"ISO 8537 Allegato C\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-834x1024.webp 834w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-244x300.webp 244w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-768x943.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-1251x1536.webp 1251w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-1668x2048.webp 1668w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-10x12.webp 10w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C.webp 1848w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">ISO 8537 Allegato C<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4f5b350 e-con-full e-flex e-con e-child\" data-id=\"4f5b350\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b02950d elementor-widget elementor-widget-image\" data-id=\"b02950d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/elementor\/thumbs\/SSR-01-Syringe-Sliding-Resistance-Tester-scaled-rn4ztcwa0vu2nv5accvgu3o8gcq1q0c2tqpka41udw.webp\" title=\"SSR-01 Tester di resistenza allo scorrimento delle siringhe\" alt=\"SSR-01 Tester di resistenza allo scorrimento delle siringhe\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">SSR-01 Tester di resistenza allo scorrimento delle siringhe<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9da22d5 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"9da22d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 data-section-id=\"1qgfchs\" data-start=\"3030\" data-end=\"3069\">Test di rottura e forza di scorrimento<\/h3><p data-start=\"3071\" data-end=\"3207\"><strong data-start=\"3071\" data-end=\"3110\">Test di rottura e forza di scorrimento<\/strong> svolge un ruolo fondamentale nella valutazione dell'usabilit\u00e0 delle siringhe. Le siringhe di alta qualit\u00e0 devono dimostrare:<\/p><ul data-start=\"3209\" data-end=\"3319\"><li data-section-id=\"13vpip9\" data-start=\"3209\" data-end=\"3231\">Corsa fluida del pistone<\/li><li data-section-id=\"6p5d4b\" data-start=\"3232\" data-end=\"3258\">Comportamento stabile all'attrito<\/li><li data-section-id=\"7wl59y\" data-start=\"3259\" data-end=\"3286\">Fluttuazione minima della forza<\/li><li data-section-id=\"xdgzww\" data-start=\"3287\" data-end=\"3319\">Prestazioni affidabili del lubrificante<\/li><\/ul><p data-start=\"3321\" data-end=\"3459\">Una macchina universale per prove sui materiali, dotata di sensori di forza e di dispositivi a siringa personalizzati, pu\u00f2 misurare con precisione questi parametri.<\/p><p data-start=\"3461\" data-end=\"3550\">Cell Instruments raccomanda sistemi di prova di precisione a compressione e a trazione in grado di:<\/p><ul data-start=\"3552\" data-end=\"3716\"><li data-section-id=\"t8upzl\" data-start=\"3552\" data-end=\"3587\">Acquisizione della forza ad alta risoluzione<\/li><li data-section-id=\"2nuhzd\" data-start=\"3588\" data-end=\"3625\">Curve forza-spostamento in tempo reale<\/li><li data-section-id=\"1ajf2el\" data-start=\"3626\" data-end=\"3662\">Controllo della velocit\u00e0 di prova programmabile<\/li><li data-section-id=\"wk2t5e\" data-start=\"3663\" data-end=\"3716\">Analisi statistica per la verifica della qualit\u00e0 dei lotti<\/li><\/ul><p data-start=\"3718\" data-end=\"3843\">Questi sistemi aiutano i produttori di siringhe a ottimizzare la finitura superficiale del cilindro, la geometria del pistone e i processi di lubrificazione del silicone.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7d5e890 e-flex e-con-boxed e-con e-parent\" data-id=\"7d5e890\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a7e615 elementor-widget elementor-widget-heading\" data-id=\"3a7e615\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test di tenuta per siringhe sterili monouso<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2a1077b e-con-full e-flex e-con e-child\" data-id=\"2a1077b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bdb9680 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"bdb9680\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3898\" data-end=\"4086\"><strong data-start=\"3898\" data-end=\"3945\">Test di tenuta per siringa sterile monouso<\/strong> \u00e8 una delle sezioni pi\u00f9 importanti della norma ISO 8537, perch\u00e9 le perdite possono compromettere la sterilit\u00e0, l'accuratezza dell'iniezione e la sicurezza del paziente.<\/p><p data-start=\"4088\" data-end=\"4116\">Lo standard valuta entrambi:<\/p><ul data-start=\"4118\" data-end=\"4185\"><li data-section-id=\"1oxsryt\" data-start=\"4118\" data-end=\"4149\">Perdita d'aria durante l'aspirazione<\/li><li data-section-id=\"1hssqyx\" data-start=\"4150\" data-end=\"4185\">Perdita di liquido durante la compressione<\/li><\/ul><p data-start=\"4187\" data-end=\"4253\">Il test di tenuta coinvolge diversi componenti della siringa, tra cui la siringa:<\/p><ul data-start=\"4255\" data-end=\"4325\"><li data-section-id=\"1vo9gki\" data-start=\"4255\" data-end=\"4263\">Barile<\/li><li data-section-id=\"30utxz\" data-start=\"4264\" data-end=\"4272\">Pistone<\/li><li data-section-id=\"152o3t3\" data-start=\"4273\" data-end=\"4289\">Tappo in gomma<\/li><li data-section-id=\"1t04wdn\" data-start=\"4290\" data-end=\"4298\">Ago<\/li><li data-section-id=\"1o447r\" data-start=\"4299\" data-end=\"4304\">Mozzo<\/li><li data-section-id=\"ergued\" data-start=\"4305\" data-end=\"4325\">Connessioni degli ugelli<\/li><\/ul><p data-start=\"4327\" data-end=\"4446\">L'affidabilit\u00e0 delle prestazioni di tenuta garantisce che nessun fluido o aria possa bypassare le interfacce di tenuta durante le normali condizioni d'uso.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0151446 elementor-widget elementor-widget-image\" data-id=\"0151446\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"464\" height=\"1024\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-464x1024.png\" class=\"attachment-large size-large wp-image-895\" alt=\"ISO 8537 Rappresentazione schematica della siringa da insulina monouso\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-464x1024.png 464w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-136x300.png 136w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-768x1695.png 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-696x1536.png 696w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-5x12.png 5w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use.png 852w\" sizes=\"(max-width: 464px) 100vw, 464px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26e3b02 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"26e3b02\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table width=\"269\"><tbody><tr><td width=\"20\">1<\/td><td width=\"100\">cappuccio dell'ago<\/td><td width=\"28\">10<\/td><td width=\"121\">tappo del pistone<\/td><\/tr><tr><td width=\"20\">2<\/td><td width=\"100\">tappo dell'ugello<\/td><td width=\"28\">11<\/td><td width=\"121\">impugnature per le dita<\/td><\/tr><tr><td width=\"20\">3<\/td><td width=\"100\">lume dell'ugello<\/td><td width=\"28\">12<\/td><td width=\"121\">linea fiduciale<\/td><\/tr><tr><td width=\"20\">4<\/td><td width=\"100\">ugello<\/td><td width=\"28\">13<\/td><td width=\"121\">capacit\u00e0 nominale<\/td><\/tr><tr><td width=\"20\">5<\/td><td width=\"100\">barile<\/td><td width=\"28\">14<\/td><td width=\"121\">linee di laurea<\/td><\/tr><tr><td width=\"20\">6<\/td><td width=\"100\">tappo a stantuffo<\/td><td width=\"28\">15<\/td><td width=\"121\">linea zero<\/td><\/tr><tr><td width=\"20\">7<\/td><td width=\"100\">sigilli<\/td><td width=\"28\">16<\/td><td width=\"121\">tubo ad ago<\/td><\/tr><tr><td width=\"20\">8<\/td><td width=\"100\">stantuffo<\/td><td width=\"28\">17<\/td><td width=\"121\">mozzo<\/td><\/tr><tr><td width=\"20\">9<\/td><td width=\"100\">pulsante<\/td><td>\u00a0<\/td><td>\u00a0<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5ca68da e-flex e-con-boxed e-con e-parent\" data-id=\"5ca68da\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c08b839 elementor-widget elementor-widget-heading\" data-id=\"c08b839\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test di perdita d'aria con siringa e metodi di rilevamento delle perdite di vuoto<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1de7ad8 elementor-widget elementor-widget-text-editor\" data-id=\"1de7ad8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4516\" data-end=\"4635\">Il <strong data-start=\"4520\" data-end=\"4548\">test di tenuta dell'aria della siringa<\/strong> descritto nell'Allegato B e nell'Allegato F valuta le perdite in condizioni di pressione negativa.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-662d174 e-con-full e-flex e-con e-child\" data-id=\"662d174\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-e09dc78 e-con-full e-flex e-con e-child\" data-id=\"e09dc78\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6604812 elementor-widget elementor-widget-text-editor\" data-id=\"6604812\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4637\" data-end=\"4847\">Nell'Allegato B, l'ugello della siringa si collega a un raccordo di riferimento e la siringa viene parzialmente riempita d'acqua. Un vuoto di <strong data-start=\"4760\" data-end=\"4797\">88 kPa sotto la pressione atmosferica<\/strong> viene applicato gradualmente. L'operatore esamina quindi:<\/p><ul data-start=\"4849\" data-end=\"4972\"><li data-section-id=\"nfom55\" data-start=\"4849\" data-end=\"4883\">Perdita d'aria oltre la guarnizione del pistone<\/li><li data-section-id=\"cbijpf\" data-start=\"4884\" data-end=\"4920\">Stabilit\u00e0 della pressione per 60 secondi<\/li><li data-section-id=\"y5dh1c\" data-start=\"4921\" data-end=\"4972\">Separazione tra il tappo di gomma e lo stantuffo<\/li><\/ul><p data-start=\"4974\" data-end=\"5081\">Questa procedura rappresenta una delle pi\u00f9 efficaci <strong data-start=\"5026\" data-end=\"5059\">metodi di rilevamento delle perdite di vuoto<\/strong> per le siringhe da insulina.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-367cbd1 elementor-widget elementor-widget-image\" data-id=\"367cbd1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"429\" height=\"343\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-B.webp\" class=\"attachment-large size-large wp-image-883\" alt=\"ISO 8537 Allegato B Perdita d&#039;aria durante l&#039;aspirazione\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-B.webp 429w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-B-300x240.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-B-15x12.webp 15w\" sizes=\"(max-width: 429px) 100vw, 429px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">ISO 8537 Allegato B Perdita d'aria durante l'aspirazione<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b2032f elementor-widget elementor-widget-image\" data-id=\"6b2032f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"679\" height=\"1024\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-679x1024.webp\" class=\"attachment-large size-large wp-image-884\" alt=\"SLT-02 Tester di perdite da siringa\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-679x1024.webp 679w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-199x300.webp 199w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-768x1158.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1019x1536.webp 1019w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1358x2048.webp 1358w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-8x12.webp 8w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp 1698w\" sizes=\"(max-width: 679px) 100vw, 679px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">SLT-02 Tester per siringhe<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2baf071 e-flex e-con-boxed e-con e-parent\" data-id=\"2baf071\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3458faa elementor-widget elementor-widget-heading\" data-id=\"3458faa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test di perdita di liquido dalla siringa sotto compressione<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e6d789e e-con-full e-flex e-con e-child\" data-id=\"e6d789e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d45890 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"7d45890\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"5667\" data-end=\"5789\">Il <strong data-start=\"5671\" data-end=\"5702\">test di tenuta del liquido della siringa<\/strong> specificato nell'Allegato E valuta le prestazioni della tenuta in condizioni di pressione interna.<\/p><p data-start=\"5791\" data-end=\"5806\">La siringa \u00e8:<\/p><ol data-start=\"5808\" data-end=\"5928\"><li data-section-id=\"6wnabh\" data-start=\"5808\" data-end=\"5841\">Riempito oltre la capacit\u00e0 nominale<\/li><li data-section-id=\"1fqlmrf\" data-start=\"5842\" data-end=\"5858\">Spurgato dall'aria<\/li><li data-section-id=\"1qsq13s\" data-start=\"5859\" data-end=\"5884\">Pressurizzato a 300 kPa<\/li><li data-section-id=\"96c87l\" data-start=\"5885\" data-end=\"5928\">Mantenuto in pressione per 30 secondi<\/li><\/ol><p data-start=\"5930\" data-end=\"5967\">Durante il test, gli ispettori valutano:<\/p><ul data-start=\"5969\" data-end=\"6054\"><li data-section-id=\"yefbo4\" data-start=\"5969\" data-end=\"5986\">Movimento del pistone<\/li><li data-section-id=\"te6jnt\" data-start=\"5987\" data-end=\"6014\">Perdite dalle guarnizioni del pistone<\/li><li data-section-id=\"hl3ixi\" data-start=\"6015\" data-end=\"6054\">Perdite alle giunzioni dell'ugello o dell'ago<\/li><\/ul><p data-start=\"6056\" data-end=\"6141\">Questo metodo verifica l'integrit\u00e0 delle interfacce di tenuta durante la simulazione dell'iniezione.<\/p><p data-start=\"6143\" data-end=\"6227\">Un sistema di prova di tenuta in pressione adeguatamente progettato pu\u00f2 aiutare i produttori a valutare:<\/p><ul data-start=\"6229\" data-end=\"6353\"><li data-section-id=\"swbrf5\" data-start=\"6229\" data-end=\"6261\">Qualit\u00e0 di tenuta del tappo in gomma<\/li><li data-section-id=\"1ekpexs\" data-start=\"6262\" data-end=\"6291\">Affidabilit\u00e0 del collegamento Luer<\/li><li data-section-id=\"1dtrbjl\" data-start=\"6292\" data-end=\"6324\">Coerenza dimensionale della canna<\/li><li data-section-id=\"1wg6zas\" data-start=\"6325\" data-end=\"6353\">Prestazioni dell'incollaggio ad ago<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e65e0c6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"e65e0c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"465\" height=\"1024\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-465x1024.webp\" class=\"attachment-large size-large wp-image-885\" alt=\"SPPT-01 Tester di tenuta a pressione positiva per siringhe\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-465x1024.webp 465w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-136x300.webp 136w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-768x1690.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-698x1536.webp 698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-931x2048.webp 931w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-5x12.webp 5w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-scaled.webp 1164w\" sizes=\"(max-width: 465px) 100vw, 465px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">SPPT-01 Tester di tenuta a pressione positiva per siringhe<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4073de e-flex e-con-boxed e-con e-parent\" data-id=\"d4073de\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-758cd11 elementor-widget elementor-widget-heading\" data-id=\"758cd11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Misura dello spazio morto per la precisione della siringa<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6da682f elementor-widget elementor-widget-text-editor\" data-id=\"6da682f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"6408\" data-end=\"6526\"><strong data-start=\"6408\" data-end=\"6434\">Misura dello spazio morto<\/strong> \u00e8 essenziale per le siringhe da insulina, perch\u00e9 il liquido residuo influisce direttamente sulla precisione del dosaggio.<\/p><p data-start=\"6528\" data-end=\"6620\">La norma ISO 8537 definisce lo spazio morto come il volume d'acqua rimanente dopo la completa depressione dello stantuffo.<\/p><p data-start=\"6622\" data-end=\"6645\">La procedura comprende:<\/p><ul data-start=\"6647\" data-end=\"6775\"><li data-section-id=\"14dqth4\" data-start=\"6647\" data-end=\"6684\">Pesatura accurata delle siringhe vuote<\/li><li data-section-id=\"6xmjzm\" data-start=\"6685\" data-end=\"6715\">Riempimento con acqua distillata<\/li><li data-section-id=\"1y173or\" data-start=\"6716\" data-end=\"6746\">Espulsione completa del liquido<\/li><li data-section-id=\"fuewb\" data-start=\"6747\" data-end=\"6775\">Ripesatura dopo lo scarico<\/li><\/ul><p data-start=\"6777\" data-end=\"6827\">La massa rimanente corrisponde al volume residuo.<\/p><p data-start=\"6829\" data-end=\"6858\">Le siringhe a basso spazio morto aiutano:<\/p><ul data-start=\"6860\" data-end=\"6950\"><li data-section-id=\"xvtq2v\" data-start=\"6860\" data-end=\"6885\">Ridurre gli sprechi di farmaci<\/li><li data-section-id=\"juz4tb\" data-start=\"6886\" data-end=\"6912\">Migliorare la precisione del dosaggio<\/li><li data-section-id=\"10nqsv3\" data-start=\"6913\" data-end=\"6950\">Ridurre al minimo la ritenzione di insulina residua<\/li><\/ul><p data-start=\"6952\" data-end=\"7092\">Le apparecchiature di prova con bilance analitiche e dispositivi di manipolazione controllata migliorano la coerenza delle misure per i programmi di garanzia della qualit\u00e0.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c7f4aa5 e-flex e-con-boxed e-con e-parent\" data-id=\"c7f4aa5\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9a263b1 elementor-widget elementor-widget-heading\" data-id=\"9a263b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Importanza di testare i componenti delle siringhe<br><small>---Ugello, mozzo, ago, canna, pistone e tappo in gomma<\/small><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-088c9f2 elementor-widget elementor-widget-text-editor\" data-id=\"088c9f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"7201\" data-end=\"7307\">I test ISO 8537 valutano l'interazione tra pi\u00f9 componenti della siringa piuttosto che parti isolate.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ee707f7 e-con-full e-flex e-con e-child\" data-id=\"ee707f7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-af54839 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"af54839\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"7201\" data-end=\"7307\">\u00a0Le interfacce critiche includono:<\/p><div class=\"TyagGW_tableContainer\"><div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"7339\" data-end=\"7613\"><thead data-start=\"7339\" data-end=\"7376\"><tr data-start=\"7339\" data-end=\"7376\"><th class=\"\" data-start=\"7339\" data-end=\"7351\" data-col-size=\"sm\">Componente<\/th><th class=\"\" data-start=\"7351\" data-end=\"7376\" data-col-size=\"sm\">Importanza funzionale<\/th><\/tr><\/thead><tbody data-start=\"7387\" data-end=\"7613\"><tr data-start=\"7387\" data-end=\"7424\"><td data-start=\"7387\" data-end=\"7396\" data-col-size=\"sm\">Ugello<\/td><td data-start=\"7396\" data-end=\"7424\" data-col-size=\"sm\">Integrit\u00e0 del trasferimento del fluido<\/td><\/tr><tr data-start=\"7425\" data-end=\"7462\"><td data-start=\"7425\" data-end=\"7431\" data-col-size=\"sm\">Mozzo<\/td><td data-start=\"7431\" data-end=\"7462\" data-col-size=\"sm\">Stabilit\u00e0 del collegamento dell'ago<\/td><\/tr><tr data-start=\"7463\" data-end=\"7497\"><td data-start=\"7463\" data-end=\"7472\" data-col-size=\"sm\">Ago<\/td><td data-start=\"7472\" data-end=\"7497\" data-col-size=\"sm\">Prestazioni di iniezione<\/td><\/tr><tr data-start=\"7498\" data-end=\"7531\"><td data-start=\"7498\" data-end=\"7507\" data-col-size=\"sm\">Barile<\/td><td data-start=\"7507\" data-end=\"7531\" data-col-size=\"sm\">Precisione dimensionale<\/td><\/tr><tr data-start=\"7532\" data-end=\"7573\"><td data-start=\"7532\" data-end=\"7541\" data-col-size=\"sm\">Pistone<\/td><td data-start=\"7541\" data-end=\"7573\" data-col-size=\"sm\">Funzionamento e tenuta uniformi<\/td><\/tr><tr data-start=\"7574\" data-end=\"7613\"><td data-start=\"7574\" data-end=\"7591\" data-col-size=\"sm\">Tappo in gomma<\/td><td data-start=\"7591\" data-end=\"7613\" data-col-size=\"sm\">Prevenzione delle perdite<\/td><\/tr><\/tbody><\/table><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2b1852b elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"2b1852b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"7615\" data-end=\"7668\">Qualsiasi incoerenza tra questi componenti pu\u00f2 portare a:<\/p><ul data-start=\"7670\" data-end=\"7749\"><li data-section-id=\"ujvyq0\" data-start=\"7670\" data-end=\"7679\">Perdite<\/li><li data-section-id=\"1g1kth9\" data-start=\"7680\" data-end=\"7703\">Instabilit\u00e0 dell'iniezione<\/li><li data-section-id=\"rmryg9\" data-start=\"7704\" data-end=\"7731\">Forza operativa eccessiva<\/li><li data-section-id=\"17chdkf\" data-start=\"7732\" data-end=\"7749\">Imprecisione della dose<\/li><\/ul><p data-start=\"7751\" data-end=\"7845\">Un test completo richiede quindi sistemi integrati di valutazione meccanica e delle perdite.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>La norma ISO 8537 definisce i metodi di prova critici per le siringhe sterili monouso per insulina, tra cui le prove di tenuta della siringa, le procedure di prova dell'integrit\u00e0 della tenuta della siringa, le prove di forza di scorrimento della siringa e la misurazione dello spazio morto.<\/p>","protected":false},"author":2,"featured_media":0,"parent":603,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-878","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages\/878","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/comments?post=878"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages\/878\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages\/603"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/media?parent=878"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}