{"id":608,"date":"2025-07-02T05:36:28","date_gmt":"2025-07-02T05:36:28","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=608"},"modified":"2026-05-19T07:09:42","modified_gmt":"2026-05-19T07:09:42","slug":"iso-7886-1","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/it\/standards\/iso-7886-1","title":{"rendered":"ISO 7886-1"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"608\" class=\"elementor elementor-608\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f03c7a9 e-flex e-con-boxed e-con e-parent\" data-id=\"f03c7a9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1212df8 elementor-widget elementor-widget-heading\" data-id=\"1212df8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 7886-1 Standard per il test di funzionalit\u00e0 delle siringhe<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1cd79c0 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"1cd79c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"389\" data-end=\"862\"><strong data-start=\"408\" data-end=\"422\">ISO 7886-1<\/strong> \u00e8 lo standard riconosciuto a livello internazionale che definisce i requisiti di prestazione e di prova per <em data-start=\"524\" data-end=\"599\">siringhe ipodermiche sterili monouso, destinate all'uso manuale<\/em>. Questo standard svolge un ruolo fondamentale nel controllo di qualit\u00e0 delle siringhe, garantendo la sicurezza funzionale e la protezione del paziente. Gli ingegneri addetti al controllo della qualit\u00e0 e gli specialisti delle normative si affidano a questo documento per guidare <em data-start=\"797\" data-end=\"828\">test di funzionalit\u00e0 della siringa<\/em> e convalidare le prestazioni del prodotto. Da <strong data-start=\"869\" data-end=\"908\">test di rottura e forza di scorrimento<\/strong> a <strong data-start=\"912\" data-end=\"936\">test di tenuta delle siringhe<\/strong>La norma ISO 7886-1 definisce metodi di prova precisi per valutare l'integrit\u00e0 delle siringhe.\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1cadcda e-flex e-con-boxed e-con e-parent\" data-id=\"1cadcda\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5506c95 elementor-widget elementor-widget-heading\" data-id=\"5506c95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Requisiti prestazionali chiave secondo ISO 7886-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd9cbb4 elementor-widget elementor-widget-text-editor\" data-id=\"dd9cbb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Spazio morto<\/h3><p data-start=\"347\" data-end=\"741\">Per ridurre lo spreco di farmaci e minimizzare il rischio di contaminazione incrociata, la norma ISO 7886-1 richiede che lo spazio morto della siringa, ovvero il volume di liquido residuo dopo l'inserimento completo dello stantuffo, sia ridotto al minimo.<\/p><h3>Perdite di aria e liquidi<\/h3><p data-start=\"743\" data-end=\"1267\">Le siringhe devono dimostrare una solida capacit\u00e0 di tenuta. Secondo <em data-start=\"850\" data-end=\"859\">Allegato D<\/em>, ci dovrebbe essere <strong data-start=\"877\" data-end=\"908\">nessuna perdita d'acqua visibile<\/strong> oltre il tappo dello stantuffo o la guarnizione sottoposta a compressione. Mentre sono ammesse piccole gocce tra le guarnizioni interne, le perdite esterne costituiscono un guasto. Inoltre, <em data-start=\"1076\" data-end=\"1085\">Allegato B<\/em> prevede che <strong data-start=\"1100\" data-end=\"1118\">nessuna perdita d'aria<\/strong> o calo della pressione del vuoto possono verificarsi durante il test di aspirazione. Questi criteri garantiscono l'integrit\u00e0 della barriera della siringa e un'applicazione clinica sicura.<\/p><h3>Forza di funzionamento del pistone<\/h3><p data-start=\"1269\" data-end=\"1702\">La norma ISO 7886-1 raccomanda di verificare le forze necessarie per avviare e mantenere il movimento dello stantuffo, poich\u00e9 da ci\u00f2 dipendono l'utilizzabilit\u00e0 della siringa e il controllo della dose. <em data-start=\"1457\" data-end=\"1466\">Allegato E<\/em> presenta un metodo per misurare la <strong data-start=\"1500\" data-end=\"1532\">si staccano e scivolano le forze<\/strong> utilizzando un sistema di test meccanico. Sebbene questo test sia informativo e non obbligatorio, svolge un ruolo cruciale nel garantire prestazioni coerenti e di facile utilizzo.<\/p><h3>Inserimento e ritenzione del pistone<\/h3><p>Il tappo dello stantuffo deve essere inserito saldamente nel cilindro. Per confermarlo, la siringa viene riempita fino alla sua capacit\u00e0 nominale e tenuta in verticale, sia in posizione verticale che capovolta. In entrambi gli orientamenti, lo stantuffo deve <strong data-start=\"1945\" data-end=\"1979\">non si muove a causa del proprio peso<\/strong> o il solo peso dell'acqua. Questo requisito garantisce che non si verifichino movimenti involontari che potrebbero causare errori di dosaggio o perdite.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f56e8f6 e-flex e-con-boxed e-con e-parent\" data-id=\"f56e8f6\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2f8a27b elementor-widget elementor-widget-heading\" data-id=\"2f8a27b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test di funzionalit\u00e0 delle siringhe: Parametri chiave e metodi di prova<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5563edc e-con-full e-flex e-con e-child\" data-id=\"5563edc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-3c81440 e-con-full e-flex e-con e-child\" data-id=\"3c81440\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dcd03b3 elementor-widget elementor-widget-text-editor\" data-id=\"dcd03b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Test di rottura e forza di scorrimento<\/h3><p data-start=\"1844\" data-end=\"2038\"><strong data-start=\"1844\" data-end=\"1855\">Allegato E<\/strong> della norma ISO 7886-1 specifica il metodo per la determinazione della <em data-start=\"1911\" data-end=\"1924\">sciogliersi<\/em> e <em data-start=\"1929\" data-end=\"1942\">forza di scorrimento<\/em> necessarie per azionare lo stantuffo. Queste forze influenzano l'esperienza dell'utente e il controllo del dosaggio.<\/p><ul><li data-start=\"2042\" data-end=\"2112\"><a href=\"https:\/\/www.syringetest.com\/it\/break-loose-and-glide-force-testing\/\"><strong data-start=\"2042\" data-end=\"2063\">Forza di rottura<\/strong><\/a> \u00e8 la forza iniziale necessaria per spostare il pistone.<\/li><li data-start=\"2115\" data-end=\"2188\"><a href=\"https:\/\/www.syringetest.com\/it\/break-loose-and-glide-force-testing\/\"><strong data-start=\"2115\" data-end=\"2130\">Forza di scorrimento<\/strong><\/a> \u00e8 la forza media necessaria per continuare il movimento dello stantuffo.<\/li><\/ul><p data-start=\"2190\" data-end=\"2217\"><strong data-start=\"2190\" data-end=\"2217\">Punti salienti del metodo di prova:<\/strong><\/p><ul><li data-start=\"2220\" data-end=\"2329\">Utilizzare un sistema di test meccanico (ad esempio, Cell Instruments'). <strong data-start=\"2277\" data-end=\"2309\">MST-01 Tester per siringhe medicali<\/strong>) a 100 \u00b1 5 mm\/min.<\/li><li data-start=\"2332\" data-end=\"2369\">Riempire la siringa con acqua a 23 \u00b1 5 \u00b0C.<\/li><li data-start=\"2372\" data-end=\"2457\">Collegare la siringa al tubo ed espellere l'acqua finch\u00e9 lo stantuffo non raggiunge il segno nominale.<\/li><li data-start=\"2460\" data-end=\"2467\">Record:<ul><li data-start=\"2472\" data-end=\"2499\">Forza di movimento iniziale (f\u209b)<\/li><li data-start=\"2504\" data-end=\"2525\">Forza media di traslazione (F)<\/li><li data-start=\"2530\" data-end=\"2558\">Forza di resistenza di picco (Fmax)<\/li><\/ul><\/li><\/ul><p data-start=\"2560\" data-end=\"2677\"><em data-start=\"2560\" data-end=\"2677\">Le prestazioni di scorrimento costanti garantiscono la scorrevolezza dell'iniezione e il comfort dell'utente, rendendolo un punto di riferimento fondamentale per la qualit\u00e0.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e0368a elementor-widget elementor-widget-image\" data-id=\"8e0368a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"546\" height=\"719\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\" class=\"attachment-large size-large wp-image-613\" alt=\"ISO 7886-1 Allegato E\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp 546w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E-228x300.webp 228w\" sizes=\"(max-width: 546px) 100vw, 546px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e0724ff elementor-widget elementor-widget-text-editor\" data-id=\"e0724ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Rilevamento di perdite di liquido dalla siringa (sotto compressione)<\/h3><p data-start=\"2741\" data-end=\"2896\"><strong data-start=\"2741\" data-end=\"2752\">Allegato D<\/strong> delinea un metodo per rilevare <a href=\"https:\/\/www.syringetest.com\/it\/syringe-liquid-leakage-test-for-closure-system\/\"><strong data-start=\"2781\" data-end=\"2799\">perdita di liquido<\/strong><\/a> oltre il <strong data-start=\"2809\" data-end=\"2833\">guarnizione del tappo del pistone<\/strong> durante la compressione, un indicatore cruciale dell'affidabilit\u00e0 della siringa.<\/p><p data-start=\"2898\" data-end=\"2915\"><strong data-start=\"2898\" data-end=\"2915\">Processo di test:<\/strong><\/p><ul><li data-start=\"2918\" data-end=\"2985\">Riempire la siringa al volume nominale con acqua distillata (18-28 \u00b0C).<\/li><li data-start=\"2988\" data-end=\"3049\">Sigillare l'ugello della siringa utilizzando raccordi conformi alla norma ISO 80369-7.<\/li><li data-start=\"3052\" data-end=\"3098\">Applicare una forza laterale (0,25-3 N) al pistone.<\/li><li data-start=\"3101\" data-end=\"3163\">Applicare una forza assiale per generare una pressione interna (200-300 kPa).<\/li><li data-start=\"3166\" data-end=\"3193\">Mantenere per 30-35 secondi.<\/li><li data-start=\"3196\" data-end=\"3238\">Controllare che non vi siano fuoriuscite di liquido dalla canna.<\/li><\/ul><p data-start=\"3240\" data-end=\"3361\">Cell Instruments offre il <strong data-start=\"3268\" data-end=\"3298\">SLT-02 Tester per siringhe<\/strong>ideale per un controllo preciso della pressione e per l'osservazione in tempo reale.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2bd0256 e-con-full e-flex e-con e-child\" data-id=\"2bd0256\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bc3f908 elementor-widget elementor-widget-text-editor\" data-id=\"bc3f908\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Rilevamento di perdite d'aria dalla siringa (durante l'aspirazione)<\/h3><p data-start=\"3422\" data-end=\"3549\"><strong data-start=\"3422\" data-end=\"3433\">Allegato B<\/strong> definisce le procedure per <strong data-start=\"3457\" data-end=\"3490\">rilevamento delle perdite d'aria della siringa<\/strong> e verificare la tenuta del tappo dello stantuffo durante l'aspirazione.<\/p><p data-start=\"3551\" data-end=\"3565\"><strong data-start=\"3551\" data-end=\"3565\">Procedura:<\/strong><\/p><ul><li data-start=\"3568\" data-end=\"3635\">Riempire parzialmente la siringa con acqua e tirare lo stantuffo fino al segno nominale.<\/li><li data-start=\"3638\" data-end=\"3690\">Fissare lo stantuffo e collegare la siringa al sistema di vuoto.<\/li><li data-start=\"3693\" data-end=\"3736\">Generare 88 kPa al di sotto della pressione atmosferica.<\/li><li data-start=\"3739\" data-end=\"3762\">Osservare per 60 secondi:<ul><li data-start=\"3767\" data-end=\"3810\">Caduta di pressione del manometro (indica una perdita)<\/li><li data-start=\"3815\" data-end=\"3848\">Distacco o instabilit\u00e0 del pistone<\/li><\/ul><\/li><\/ul><p data-start=\"3850\" data-end=\"3955\">L'ermeticit\u00e0 garantisce l'accuratezza del dosaggio e previene la contaminazione, rendendo questo test essenziale per un uso sicuro.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a0b40de elementor-widget elementor-widget-image\" data-id=\"a0b40de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"694\" height=\"570\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B.webp\" class=\"attachment-large size-large wp-image-614\" alt=\"ISO 7886-1 Allegato B\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B.webp 694w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B-300x246.webp 300w\" sizes=\"(max-width: 694px) 100vw, 694px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a4c9f2a e-flex e-con-boxed e-con e-parent\" data-id=\"a4c9f2a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-032dedc elementor-widget elementor-widget-heading\" data-id=\"032dedc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Selezione della giusta apparecchiatura di test a siringa<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-02a9ca0 e-grid e-con-full e-con e-child\" data-id=\"02a9ca0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8858447 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"8858447\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img decoding=\"async\" width=\"1698\" height=\"2560\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp\" class=\"attachment-full size-full wp-image-884\" alt=\"SLT-02 Tester di perdite da siringa\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp 1698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-199x300.webp 199w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-679x1024.webp 679w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-768x1158.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1019x1536.webp 1019w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1358x2048.webp 1358w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-8x12.webp 8w\" sizes=\"(max-width: 1698px) 100vw, 1698px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">SLT-02 Tester per siringhe<\/h3><p class=\"elementor-image-box-description\">Questo strumento applica con precisione un vuoto controllato alla siringa, consentendo un monitoraggio accurato delle variazioni di pressione e dell'integrit\u00e0 dello stantuffo. Progettato con connessioni compatibili con la norma ISO 80369-7 e meccanismi di serraggio sicuri, l'SLT-01 assicura una valutazione approfondita della tenuta dell'aria e della ritenzione del tappo dello stantuffo.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84ddc7f elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"84ddc7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img loading=\"lazy\" decoding=\"async\" width=\"1285\" height=\"2560\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-scaled.webp\" class=\"attachment-full size-full wp-image-889\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-scaled.webp 1285w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-151x300.webp 151w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-514x1024.webp 514w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-768x1530.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-771x1536.webp 771w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-1028x2048.webp 1028w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/MST-01-Medical-Syringe-Tester-6x12.webp 6w\" sizes=\"(max-width: 1285px) 100vw, 1285px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">MST-01 Tester per siringhe medicali<\/h3><p class=\"elementor-image-box-description\">Utilizza un sistema meccanico ad alta precisione per misurare le forze di distacco e di scorrimento durante l'espulsione del fluido. L'MST-01 consente ai produttori di quantificare la resistenza all'avvio e alla corsa, fornendo dati essenziali per garantire un movimento fluido e costante dello stantuffo, fondamentale per garantire sicurezza e comfort.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bda0648 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"bda0648\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img loading=\"lazy\" decoding=\"async\" width=\"1164\" height=\"2560\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-scaled.webp\" class=\"attachment-full size-full wp-image-885\" alt=\"SPPT-01 Tester di tenuta a pressione positiva per siringhe\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-scaled.webp 1164w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-136x300.webp 136w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-465x1024.webp 465w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-768x1690.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-698x1536.webp 698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-931x2048.webp 931w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-5x12.webp 5w\" sizes=\"(max-width: 1164px) 100vw, 1164px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">SPPT-01 Tester di tenuta per siringhe<\/h3><p class=\"elementor-image-box-description\">Questo dispositivo simula la pressione all'interno del cilindro della siringa applicando carichi laterali e assiali allo stantuffo, replicando fedelmente le condizioni di utilizzo clinico. L'SSPT-01 \u00e8 progettato per rilevare anche i pi\u00f9 piccoli difetti di tenuta, aiutando i produttori a verificare l'affidabilit\u00e0 del prodotto e la conformit\u00e0 ai rigorosi standard di sicurezza.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8b0f6e0 e-flex e-con-boxed e-con e-parent\" data-id=\"8b0f6e0\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11b99fc elementor-widget elementor-widget-heading\" data-id=\"11b99fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Perch\u00e9 \u00e8 importante la conformit\u00e0 ISO 7886-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-263368c elementor-widget elementor-widget-text-editor\" data-id=\"263368c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4571\" data-end=\"4657\">La conformit\u00e0 alla norma ISO 7886-1 garantisce che le siringhe:<\/p><ul><li data-start=\"4660\" data-end=\"4682\">Erogazione di dosi precise<\/li><li data-start=\"4685\" data-end=\"4713\">Sono sicuri e facili da usare<\/li><li data-start=\"4716\" data-end=\"4740\">Rimangono sigillati durante l'uso<\/li><li data-start=\"4743\" data-end=\"4789\">Soddisfare i requisiti normativi e di esportazione globali<\/li><\/ul><p data-start=\"4791\" data-end=\"4910\">Trascurare la corretta <strong data-start=\"4809\" data-end=\"4842\">test di funzionalit\u00e0 della siringa<\/strong> possono portare a richiami di prodotti, sanzioni normative o danni ai pazienti.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-be52d1e e-grid e-con-full e-con e-parent\" data-id=\"be52d1e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c72d800 elementor-widget elementor-widget-image\" data-id=\"c72d800\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c83f8a8 e-con-full e-flex e-con e-child\" data-id=\"c83f8a8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09b28d1 elementor-widget elementor-widget-heading\" data-id=\"09b28d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Perch\u00e9 scegliere <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c87e7b1 elementor-widget elementor-widget-text-editor\" data-id=\"c87e7b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4917\" data-end=\"5240\">Comprendere e applicare <strong data-start=\"4961\" data-end=\"4975\">ISO 7886-1<\/strong> I metodi di analisi sono essenziali per qualsiasi azienda che si occupi di produzione di siringhe o di controllo della qualit\u00e0. Da <strong data-start=\"5077\" data-end=\"5116\">test di rottura e forza di scorrimento<\/strong> a <strong data-start=\"5120\" data-end=\"5153\">rilevamento di perdite di aria e liquidi<\/strong>Ogni test ha un ruolo specifico nella salvaguardia dell'affidabilit\u00e0 del prodotto e della sicurezza dell'utente.<\/p><p data-start=\"5242\" data-end=\"5537\"><strong>Syringetest.com<\/strong> fornisce un servizio avanzato <strong data-start=\"5281\" data-end=\"5310\">apparecchiatura di prova per siringhe<\/strong> progettati per supportare la completa conformit\u00e0 e la semplificazione dei flussi di lavoro del CQ. Se state cercando di aggiornare il vostro processo di convalida delle siringhe o di migliorare l'accuratezza dei test, contattateci per sapere come i nostri strumenti possono aiutarvi a soddisfare i vostri standard.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6924b06 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"6924b06\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/it\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contatto<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 7886-1 Syringe Functionality Testing Standard ISO 7886-1 is the internationally recognized standard that defines the performance and testing requirements for sterile hypodermic syringes for single use, intended for manual operation. This standard plays a vital role in syringe quality control, ensuring functional safety and patient protection. Quality control engineers and regulatory specialists rely on [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":603,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-608","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages\/608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/comments?post=608"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages\/608\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages\/603"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/media?parent=608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}