{"id":608,"date":"2025-07-02T05:36:28","date_gmt":"2025-07-02T05:36:28","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=608"},"modified":"2025-07-02T07:28:27","modified_gmt":"2025-07-02T07:28:27","slug":"iso-7886-1","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/it\/standards\/iso-7886-1","title":{"rendered":"ISO 7886-1"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"608\" class=\"elementor elementor-608\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-292be0b e-flex e-con-boxed e-con e-parent\" data-id=\"292be0b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0f48abd elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"0f48abd\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 7886-1 Standard per il test di funzionalit\u00e0 delle siringhe<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6817f29 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"6817f29\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"389\" data-end=\"862\"><strong data-start=\"408\" data-end=\"422\">ISO 7886-1<\/strong> \u00e8 lo standard riconosciuto a livello internazionale che definisce i requisiti di prestazione e di prova per <em data-start=\"524\" data-end=\"599\">siringhe ipodermiche sterili monouso, destinate all'uso manuale<\/em>. Questo standard svolge un ruolo fondamentale nel controllo di qualit\u00e0 delle siringhe, garantendo la sicurezza funzionale e la protezione del paziente. Gli ingegneri addetti al controllo della qualit\u00e0 e gli specialisti delle normative si affidano a questo documento per guidare <em data-start=\"797\" data-end=\"828\">test di funzionalit\u00e0 della siringa<\/em> e convalidare le prestazioni del prodotto. Da <strong data-start=\"869\" data-end=\"908\">test di rottura e forza di scorrimento<\/strong> a <strong data-start=\"912\" data-end=\"936\">test di tenuta delle siringhe<\/strong>La norma ISO 7886-1 definisce metodi di prova precisi per valutare l'integrit\u00e0 delle siringhe.\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad68bc6 e-flex e-con-boxed e-con e-parent\" data-id=\"ad68bc6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ecf369e elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ecf369e\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Requisiti prestazionali chiave secondo ISO 7886-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-343a570 e-n-tabs-mobile elementor-invisible elementor-widget elementor-widget-n-tabs\" data-id=\"343a570\" data-element_type=\"widget\" data-settings=\"{&quot;tabs_justify_horizontal&quot;:&quot;center&quot;,&quot;_animation&quot;:&quot;fadeInUp&quot;,&quot;horizontal_scroll&quot;:&quot;disable&quot;}\" data-widget_type=\"nested-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-tabs\" data-widget-number=\"54764912\" aria-label=\"Tab. Buka item dengan Enter atau Spasi, tutup dengan Escape dan navigasikan menggunakan tombol Panah.\" data-no-translation-aria-label=\"\">\n\t\t\t<div class=\"e-n-tabs-heading\" role=\"tablist\">\n\t\t\t\t\t<button id=\"e-n-tab-title-547649121\" class=\"e-n-tab-title\" aria-selected=\"true\" data-tab-index=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"e-n-tab-content-547649121\" style=\"--n-tabs-title-order: 1;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tSpazio morto\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-547649122\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-547649122\" style=\"--n-tabs-title-order: 2;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tPerdite di aria e liquidi\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-547649123\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-547649123\" style=\"--n-tabs-title-order: 3;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tForza di funzionamento del pistone\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-547649124\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-547649124\" style=\"--n-tabs-title-order: 4;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tInserimento e ritenzione del pistone\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t\t<\/div>\n\t\t\t<div class=\"e-n-tabs-content\">\n\t\t\t\t<div id=\"e-n-tab-content-547649121\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-547649121\" data-tab-index=\"1\" style=\"--n-tabs-title-order: 1;\" class=\"e-active elementor-element elementor-element-9d08f18 e-flex e-con-boxed e-con e-child\" data-id=\"9d08f18\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a7b7101 elementor-widget elementor-widget-text-editor\" data-id=\"a7b7101\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"347\" data-end=\"741\">Per ridurre lo spreco di farmaci e minimizzare il rischio di contaminazione incrociata, la norma ISO 7886-1 richiede che lo spazio morto della siringa, ovvero il volume di liquido residuo dopo l'inserimento completo dello stantuffo, sia ridotto al minimo.<\/p><p data-start=\"743\" data-end=\"1267\">\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-547649122\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-547649122\" data-tab-index=\"2\" style=\"--n-tabs-title-order: 2;\" class=\"elementor-element elementor-element-56c370d e-flex e-con-boxed e-con e-child\" data-id=\"56c370d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8f5102f elementor-widget elementor-widget-text-editor\" data-id=\"8f5102f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"743\" data-end=\"1267\">Le siringhe devono dimostrare una solida capacit\u00e0 di tenuta. Secondo <em data-start=\"850\" data-end=\"859\">Allegato D<\/em>, ci dovrebbe essere <strong data-start=\"877\" data-end=\"908\">nessuna perdita d'acqua visibile<\/strong> oltre il tappo dello stantuffo o la guarnizione sottoposta a compressione. Mentre sono ammesse piccole gocce tra le guarnizioni interne, le perdite esterne costituiscono un guasto. Inoltre, <em data-start=\"1076\" data-end=\"1085\">Allegato B<\/em> prevede che <strong data-start=\"1100\" data-end=\"1118\">nessuna perdita d'aria<\/strong> o calo della pressione del vuoto possono verificarsi durante il test di aspirazione. Questi criteri garantiscono l'integrit\u00e0 della barriera della siringa e un'applicazione clinica sicura.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-547649123\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-547649123\" data-tab-index=\"3\" style=\"--n-tabs-title-order: 3;\" class=\"elementor-element elementor-element-0debdba e-flex e-con-boxed e-con e-child\" data-id=\"0debdba\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-94d47e2 elementor-widget elementor-widget-text-editor\" data-id=\"94d47e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1269\" data-end=\"1702\">La norma ISO 7886-1 raccomanda di verificare le forze necessarie per avviare e mantenere il movimento dello stantuffo, poich\u00e9 da ci\u00f2 dipendono l'utilizzabilit\u00e0 della siringa e il controllo della dose. <em data-start=\"1457\" data-end=\"1466\">Allegato E<\/em> presenta un metodo per misurare la <strong data-start=\"1500\" data-end=\"1532\">si staccano e scivolano le forze<\/strong> utilizzando un sistema di test meccanico. Sebbene questo test sia informativo e non obbligatorio, svolge un ruolo cruciale nel garantire prestazioni coerenti e di facile utilizzo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-547649124\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-547649124\" data-tab-index=\"4\" style=\"--n-tabs-title-order: 4;\" class=\"elementor-element elementor-element-99198a0 e-flex e-con-boxed e-con e-child\" data-id=\"99198a0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d2653db elementor-widget elementor-widget-text-editor\" data-id=\"d2653db\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Il tappo dello stantuffo deve essere inserito saldamente nel cilindro. Per confermarlo, la siringa viene riempita fino alla sua capacit\u00e0 nominale e tenuta in verticale, sia in posizione verticale che capovolta. In entrambi gli orientamenti, lo stantuffo deve <strong data-start=\"1945\" data-end=\"1979\">non si muove a causa del proprio peso<\/strong> o il solo peso dell'acqua. Questo requisito garantisce che non si verifichino movimenti involontari che potrebbero causare errori di dosaggio o perdite.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4835ce e-flex e-con-boxed e-con e-parent\" data-id=\"d4835ce\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea29382 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ea29382\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test di funzionalit\u00e0 delle siringhe: Parametri chiave e metodi di prova<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-55047da e-con-full e-flex e-con e-child\" data-id=\"55047da\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-ae8face e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"ae8face\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7c7cd83 elementor-widget elementor-widget-heading\" data-id=\"7c7cd83\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.syringetest.com\/it\/break-loose-and-glide-force-testing\/\">Test di rottura e forza di scorrimento<\/a><\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-42248e5 elementor-widget elementor-widget-text-editor\" data-id=\"42248e5\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1844\" data-end=\"2038\"><strong data-start=\"1844\" data-end=\"1855\">Allegato E<\/strong> della norma ISO 7886-1 specifica il metodo per la determinazione della <em data-start=\"1911\" data-end=\"1924\">sciogliersi<\/em> e <em data-start=\"1929\" data-end=\"1942\">forza di scorrimento<\/em> necessarie per azionare lo stantuffo. Queste forze influenzano l'esperienza dell'utente e il controllo del dosaggio.<\/p><ul><li data-start=\"2042\" data-end=\"2112\"><a href=\"https:\/\/www.syringetest.com\/it\/break-loose-and-glide-force-testing\/\"><strong data-start=\"2042\" data-end=\"2063\">Forza di rottura<\/strong><\/a> \u00e8 la forza iniziale necessaria per spostare il pistone.<\/li><li data-start=\"2115\" data-end=\"2188\"><a href=\"https:\/\/www.syringetest.com\/it\/break-loose-and-glide-force-testing\/\"><strong data-start=\"2115\" data-end=\"2130\">Forza di scorrimento<\/strong><\/a> \u00e8 la forza media necessaria per continuare il movimento dello stantuffo.<\/li><\/ul><p data-start=\"2190\" data-end=\"2217\"><strong data-start=\"2190\" data-end=\"2217\">Punti salienti del metodo di prova:<\/strong><\/p><ul><li data-start=\"2220\" data-end=\"2329\">Utilizzare un sistema di test meccanico (ad esempio, Cell Instruments'). <strong data-start=\"2277\" data-end=\"2309\">MST-01 Tester per siringhe medicali<\/strong>) a 100 \u00b1 5 mm\/min.<\/li><li data-start=\"2332\" data-end=\"2369\">Riempire la siringa con acqua a 23 \u00b1 5 \u00b0C.<\/li><li data-start=\"2372\" data-end=\"2457\">Collegare la siringa al tubo ed espellere l'acqua finch\u00e9 lo stantuffo non raggiunge il segno nominale.<\/li><li data-start=\"2460\" data-end=\"2467\">Record:<ul><li data-start=\"2472\" data-end=\"2499\">Forza di movimento iniziale (f\u209b)<\/li><li data-start=\"2504\" data-end=\"2525\">Forza media di traslazione (F)<\/li><li data-start=\"2530\" data-end=\"2558\">Forza di resistenza di picco (Fmax)<\/li><\/ul><\/li><\/ul><p data-start=\"2560\" data-end=\"2677\"><em data-start=\"2560\" data-end=\"2677\">Le prestazioni di scorrimento costanti garantiscono la scorrevolezza dell'iniezione e il comfort dell'utente, rendendolo un punto di riferimento fondamentale per la qualit\u00e0.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fda7334 e-con-full e-flex e-con e-child\" data-id=\"fda7334\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a601c24 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-image\" data-id=\"a601c24\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInRight&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"546\" height=\"719\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\" class=\"attachment-large size-large wp-image-613\" alt=\"ISO 7886-1 Allegato E\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp 546w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E-228x300.webp 228w\" sizes=\"(max-width: 546px) 100vw, 546px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7ada073 e-con-full e-flex e-con e-child\" data-id=\"7ada073\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-61bbbd2 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"61bbbd2\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.syringetest.com\/it\/syringe-liquid-leakage-test-for-closure-system\/\">Rilevamento di perdite di liquido dalla siringa (sotto compressione)<\/a><\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e3eedc elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"0e3eedc\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2741\" data-end=\"2896\"><strong data-start=\"2741\" data-end=\"2752\">Allegato D<\/strong> delinea un metodo per rilevare <a href=\"https:\/\/www.syringetest.com\/it\/syringe-liquid-leakage-test-for-closure-system\/\"><strong data-start=\"2781\" data-end=\"2799\">perdita di liquido<\/strong><\/a> oltre il <strong data-start=\"2809\" data-end=\"2833\">guarnizione del tappo del pistone<\/strong> durante la compressione, un indicatore cruciale dell'affidabilit\u00e0 della siringa.<\/p><p data-start=\"2898\" data-end=\"2915\"><strong data-start=\"2898\" data-end=\"2915\">Processo di test:<\/strong><\/p><ul><li data-start=\"2918\" data-end=\"2985\">Riempire la siringa al volume nominale con acqua distillata (18-28 \u00b0C).<\/li><li data-start=\"2988\" data-end=\"3049\">Sigillare l'ugello della siringa utilizzando raccordi conformi alla norma ISO 80369-7.<\/li><li data-start=\"3052\" data-end=\"3098\">Applicare una forza laterale (0,25-3 N) al pistone.<\/li><li data-start=\"3101\" data-end=\"3163\">Applicare una forza assiale per generare una pressione interna (200-300 kPa).<\/li><li data-start=\"3166\" data-end=\"3193\">Mantenere per 30-35 secondi.<\/li><li data-start=\"3196\" data-end=\"3238\">Controllare che non vi siano fuoriuscite di liquido dalla canna.<\/li><\/ul><p data-start=\"3240\" data-end=\"3361\">Cell Instruments offre il <strong data-start=\"3268\" data-end=\"3298\">SLT-02 Tester per siringhe<\/strong>ideale per un controllo preciso della pressione e per l'osservazione in tempo reale.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb1aef4 e-con-full e-flex e-con e-child\" data-id=\"cb1aef4\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-64a5239 e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"64a5239\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c50402d elementor-widget elementor-widget-heading\" data-id=\"c50402d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Rilevamento di perdite d'aria dalla siringa (durante l'aspirazione)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b9b9803 elementor-widget elementor-widget-text-editor\" data-id=\"b9b9803\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3422\" data-end=\"3549\"><strong data-start=\"3422\" data-end=\"3433\">Allegato B<\/strong> definisce le procedure per <strong data-start=\"3457\" data-end=\"3490\">rilevamento delle perdite d'aria della siringa<\/strong> e verificare la tenuta del tappo dello stantuffo durante l'aspirazione.<\/p><p data-start=\"3551\" data-end=\"3565\"><strong data-start=\"3551\" data-end=\"3565\">Procedura:<\/strong><\/p><ul><li data-start=\"3568\" data-end=\"3635\">Riempire parzialmente la siringa con acqua e tirare lo stantuffo fino al segno nominale.<\/li><li data-start=\"3638\" data-end=\"3690\">Fissare lo stantuffo e collegare la siringa al sistema di vuoto.<\/li><li data-start=\"3693\" data-end=\"3736\">Generare 88 kPa al di sotto della pressione atmosferica.<\/li><li data-start=\"3739\" data-end=\"3762\">Osservare per 60 secondi:<ul><li data-start=\"3767\" data-end=\"3810\">Caduta di pressione del manometro (indica una perdita)<\/li><li data-start=\"3815\" data-end=\"3848\">Distacco o instabilit\u00e0 del pistone<\/li><\/ul><\/li><\/ul><p data-start=\"3850\" data-end=\"3955\">L'ermeticit\u00e0 garantisce l'accuratezza del dosaggio e previene la contaminazione, rendendo questo test essenziale per un uso sicuro.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a4bf01b e-con-full e-flex e-con e-child\" data-id=\"a4bf01b\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-812ae93 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-image\" data-id=\"812ae93\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInRight&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"694\" height=\"570\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B.webp\" class=\"attachment-large size-large wp-image-614\" alt=\"ISO 7886-1 Allegato B\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B.webp 694w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B-300x246.webp 300w\" sizes=\"(max-width: 694px) 100vw, 694px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-41ab1d6 e-con-full e-flex e-con e-parent\" data-id=\"41ab1d6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-48c60fb elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"48c60fb\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Selezione della giusta apparecchiatura di test a siringa<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-57384eb e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"57384eb\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInUp&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ffb5df1 eael-infobox-content-align--center eael-infobox-shape-square eael-infobox-hover-img-shape-square elementor-widget elementor-widget-eael-info-box\" data-id=\"ffb5df1\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"eael-info-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-infobox icon-on-top\">\n\t            <div class=\"infobox-icon\">\n\n                            <img decoding=\"async\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B-air-leakage-test-for-syringe.webp\" alt=\"ISO 7886-1 Allegato B prova di tenuta all&#039;aria per siringa\">\n            \n            \n            \n        <\/div>\n            <div class=\"infobox-content\">\n                    <div class=\"infobox-title-section\">\n                <h3 class=\"title\">SLT-02 Tester per siringhe<\/h3>            <\/div>\n            <div><p data-start=\"0\" data-end=\"483\">Questo strumento applica con precisione un vuoto controllato alla siringa, consentendo un monitoraggio accurato delle variazioni di pressione e dell'integrit\u00e0 dello stantuffo. Progettato con connessioni compatibili con la norma ISO 80369-7 e meccanismi di serraggio sicuri, l'SLT-01 assicura una valutazione approfondita della tenuta dell'aria e della ritenzione del tappo dello stantuffo.<\/p><p data-start=\"485\" data-end=\"945\">\u00a0<\/p><\/div>        <\/div>\n            <\/div>\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c042898 eael-infobox-content-align--center eael-infobox-shape-square eael-infobox-hover-img-shape-square elementor-widget elementor-widget-eael-info-box\" data-id=\"c042898\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"eael-info-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-infobox icon-on-top\">\n\t            <div class=\"infobox-icon\">\n\n                            <img decoding=\"async\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E-syringe-glide-force-tester.webp\" alt=\"Tester di forza di scorrimento per siringhe ISO 7886-1 Allegato E\">\n            \n            \n            \n        <\/div>\n            <div class=\"infobox-content\">\n                    <div class=\"infobox-title-section\">\n                <h2 class=\"title\">MST-01 Tester per siringhe medicali<\/h2>            <\/div>\n            <div><p data-start=\"485\" data-end=\"945\">Utilizza un sistema meccanico ad alta precisione per misurare le forze di distacco e di scorrimento durante l'espulsione del fluido. L'MST-01 consente ai produttori di quantificare la resistenza all'avvio e alla corsa, fornendo dati essenziali per garantire un movimento fluido e costante dello stantuffo, fondamentale per garantire sicurezza e comfort.<\/p><p data-start=\"947\" data-end=\"1407\" data-is-last-node=\"\" data-is-only-node=\"\">\u00a0<\/p><\/div>        <\/div>\n            <\/div>\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a5ad445 eael-infobox-content-align--center eael-infobox-shape-square eael-infobox-hover-img-shape-square elementor-widget elementor-widget-eael-info-box\" data-id=\"a5ad445\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"eael-info-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-infobox icon-on-top\">\n\t            <div class=\"infobox-icon\">\n\n                            <img decoding=\"async\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-D-liquid-leakage-at-syringe-plunger-stopper-under-compression.webp\" alt=\"ISO 7886-1 Allegato D perdita di liquido sul tappo dello stantuffo della siringa sotto compressione\">\n            \n            \n            \n        <\/div>\n            <div class=\"infobox-content\">\n                    <div class=\"infobox-title-section\">\n                <h2 class=\"title\">SPPT-01 Tester di tenuta per siringhe<\/h2>            <\/div>\n            <div><p>Questo dispositivo simula la pressione all'interno del cilindro della siringa applicando carichi laterali e assiali allo stantuffo, replicando fedelmente le condizioni di utilizzo clinico. L'SSPT-01 \u00e8 progettato per rilevare anche i pi\u00f9 piccoli difetti di tenuta, aiutando i produttori a verificare l'affidabilit\u00e0 del prodotto e la conformit\u00e0 ai rigorosi standard di sicurezza.<\/p><\/div>        <\/div>\n            <\/div>\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad468be e-flex e-con-boxed e-con e-parent\" data-id=\"ad468be\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-edb7717 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"edb7717\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Perch\u00e9 \u00e8 importante la conformit\u00e0 ISO 7886-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5810d33 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"5810d33\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4571\" data-end=\"4657\">La conformit\u00e0 alla norma ISO 7886-1 garantisce che le siringhe:<\/p><ul><li data-start=\"4660\" data-end=\"4682\">Erogazione di dosi precise<\/li><li data-start=\"4685\" data-end=\"4713\">Sono sicuri e facili da usare<\/li><li data-start=\"4716\" data-end=\"4740\">Rimangono sigillati durante l'uso<\/li><li data-start=\"4743\" data-end=\"4789\">Soddisfare i requisiti normativi e di esportazione globali<\/li><\/ul><p data-start=\"4791\" data-end=\"4910\">Trascurare la corretta <strong data-start=\"4809\" data-end=\"4842\">test di funzionalit\u00e0 della siringa<\/strong> possono portare a richiami di prodotti, sanzioni normative o danni ai pazienti.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b581cc e-con-full e-flex e-con e-parent\" data-id=\"1b581cc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-61afd37 e-grid e-con-full e-con e-child\" data-id=\"61afd37\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-f8ace73 e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"f8ace73\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94cc5ad e-flex e-con-boxed elementor-invisible e-con e-child\" data-id=\"94cc5ad\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInRight&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-907b713 elementor-widget elementor-widget-heading\" data-id=\"907b713\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Perch\u00e9 scegliere <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-718f32f elementor-widget elementor-widget-text-editor\" data-id=\"718f32f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4917\" data-end=\"5240\">Comprendere e applicare <strong data-start=\"4961\" data-end=\"4975\">ISO 7886-1<\/strong> I metodi di analisi sono essenziali per qualsiasi azienda che si occupi di produzione di siringhe o di controllo della qualit\u00e0. Da <strong data-start=\"5077\" data-end=\"5116\">test di rottura e forza di scorrimento<\/strong> a <strong data-start=\"5120\" data-end=\"5153\">rilevamento di perdite di aria e liquidi<\/strong>Ogni test ha un ruolo specifico nella salvaguardia dell'affidabilit\u00e0 del prodotto e della sicurezza dell'utente.<\/p><p data-start=\"5242\" data-end=\"5537\"><strong>Syringetest.com<\/strong> fornisce un servizio avanzato <strong data-start=\"5281\" data-end=\"5310\">apparecchiatura di prova per siringhe<\/strong> progettati per supportare la completa conformit\u00e0 e la semplificazione dei flussi di lavoro del CQ. Se state cercando di aggiornare il vostro processo di convalida delle siringhe o di migliorare l'accuratezza dei test, contattateci per sapere come i nostri strumenti possono aiutarvi a soddisfare i vostri standard.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f735b94 elementor-widget elementor-widget-eael-creative-button\" data-id=\"f735b94\" data-element_type=\"widget\" data-widget_type=\"eael-creative-button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-creative-button-wrapper\">\n\n            <a class=\"eael-creative-button eael-creative-button--default\" href=\"#\" data-text=\"Contact Us\">\n\n\t    \n                <div class=\"creative-button-inner\">\n\n                    \n                    <span class=\"cretive-button-text\">Contatto<\/span>\n\n                                    <\/div>\n\t                        <\/a>\n        <\/div>\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 7886-1 Syringe Functionality Testing Standard ISO 7886-1 is the internationally recognized standard that defines the performance and testing requirements for sterile hypodermic syringes for single use, intended for manual operation. This standard plays a vital role in syringe quality control, ensuring functional safety and patient protection. Quality control engineers and regulatory specialists rely on [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"parent":603,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-608","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 7886-1 Syringe Functionality Testing and Testing Equipment<\/title>\n<meta name=\"description\" content=\"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.syringetest.com\/it\/standards\/iso-7886-1\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 7886-1 Syringe Functionality Testing and Testing Equipment\" \/>\n<meta property=\"og:description\" content=\"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.syringetest.com\/it\/standards\/iso-7886-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Syringe and Needle Testing\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-02T07:28:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"546\" \/>\n\t<meta property=\"og:image:height\" content=\"719\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1\",\"url\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1\",\"name\":\"ISO 7886-1 Syringe Functionality Testing and Testing Equipment\",\"isPartOf\":{\"@id\":\"https:\/\/www.syringetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\",\"datePublished\":\"2025-07-02T05:36:28+00:00\",\"dateModified\":\"2025-07-02T07:28:27+00:00\",\"description\":\"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.syringetest.com\/standards\/iso-7886-1\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.syringetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Standards\",\"item\":\"https:\/\/www.syringetest.com\/standards\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ISO 7886-1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.syringetest.com\/#website\",\"url\":\"https:\/\/www.syringetest.com\/\",\"name\":\"Syringe and Needle Testing\",\"description\":\"Syringe and Needle Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.syringetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.syringetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.syringetest.com\/#organization\",\"name\":\"Syringe and Needle Testing\",\"url\":\"https:\/\/www.syringetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"width\":512,\"height\":512,\"caption\":\"Syringe and Needle Testing\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 7886-1 Syringe Functionality Testing and Testing Equipment","description":"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.syringetest.com\/it\/standards\/iso-7886-1\/","og_locale":"it_IT","og_type":"article","og_title":"ISO 7886-1 Syringe Functionality Testing and Testing Equipment","og_description":"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.","og_url":"https:\/\/www.syringetest.com\/it\/standards\/iso-7886-1\/","og_site_name":"Syringe and Needle Testing","article_modified_time":"2025-07-02T07:28:27+00:00","og_image":[{"width":546,"height":719,"url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Tempo di lettura stimato":"6 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1","url":"https:\/\/www.syringetest.com\/standards\/iso-7886-1","name":"ISO 7886-1 Syringe Functionality Testing and Testing Equipment","isPartOf":{"@id":"https:\/\/www.syringetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage"},"image":{"@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage"},"thumbnailUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp","datePublished":"2025-07-02T05:36:28+00:00","dateModified":"2025-07-02T07:28:27+00:00","description":"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.","breadcrumb":{"@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.syringetest.com\/standards\/iso-7886-1"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.syringetest.com\/"},{"@type":"ListItem","position":2,"name":"Standards","item":"https:\/\/www.syringetest.com\/standards"},{"@type":"ListItem","position":3,"name":"ISO 7886-1"}]},{"@type":"WebSite","@id":"https:\/\/www.syringetest.com\/#website","url":"https:\/\/www.syringetest.com\/","name":"Syringe and Needle Testing","description":"Syringe and Needle Test Solutions","publisher":{"@id":"https:\/\/www.syringetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.syringetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/www.syringetest.com\/#organization","name":"Syringe and Needle Testing","url":"https:\/\/www.syringetest.com\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","width":512,"height":512,"caption":"Syringe and Needle Testing"},"image":{"@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages\/608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/comments?post=608"}],"version-history":[{"count":5,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages\/608\/revisions"}],"predecessor-version":[{"id":627,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages\/608\/revisions\/627"}],"up":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/pages\/603"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/it\/wp-json\/wp\/v2\/media?parent=608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}