{"id":608,"date":"2025-07-02T05:36:28","date_gmt":"2025-07-02T05:36:28","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=608"},"modified":"2025-07-02T07:28:27","modified_gmt":"2025-07-02T07:28:27","slug":"iso-7886-1","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/id\/standards\/iso-7886-1","title":{"rendered":"ISO 7886-1"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"608\" class=\"elementor elementor-608\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-292be0b e-flex e-con-boxed e-con e-parent\" data-id=\"292be0b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0f48abd elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"0f48abd\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standar Pengujian Fungsionalitas Jarum Suntik ISO 7886-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6817f29 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"6817f29\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"389\" data-end=\"862\"><strong data-start=\"408\" data-end=\"422\">ISO 7886-1<\/strong> adalah standar yang diakui secara internasional yang mendefinisikan persyaratan kinerja dan pengujian untuk <em data-start=\"524\" data-end=\"599\">jarum suntik hipodermik steril untuk sekali pakai, dimaksudkan untuk pengoperasian manual<\/em>. Standar ini memainkan peran penting dalam kontrol kualitas jarum suntik, memastikan keamanan fungsional dan perlindungan pasien. Insinyur kontrol kualitas dan spesialis regulasi mengandalkan dokumen ini sebagai panduan <em data-start=\"797\" data-end=\"828\">pengujian fungsionalitas jarum suntik<\/em> dan memvalidasi kinerja produk. Dari <strong data-start=\"869\" data-end=\"908\">pengujian gaya lepas dan meluncur<\/strong> untuk <strong data-start=\"912\" data-end=\"936\">pengujian kebocoran jarum suntik<\/strong>ISO 7886-1 menguraikan metode pengujian yang tepat untuk mengevaluasi integritas jarum suntik.\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad68bc6 e-flex e-con-boxed e-con e-parent\" data-id=\"ad68bc6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ecf369e elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ecf369e\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Persyaratan Kinerja Utama Menurut ISO 7886-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-343a570 e-n-tabs-mobile elementor-invisible elementor-widget elementor-widget-n-tabs\" data-id=\"343a570\" data-element_type=\"widget\" data-settings=\"{&quot;tabs_justify_horizontal&quot;:&quot;center&quot;,&quot;_animation&quot;:&quot;fadeInUp&quot;,&quot;horizontal_scroll&quot;:&quot;disable&quot;}\" data-widget_type=\"nested-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-tabs\" data-widget-number=\"54764912\" aria-label=\"Tab. Buka item dengan Enter atau Spasi, tutup dengan Escape dan navigasikan menggunakan tombol Panah.\" data-no-translation-aria-label=\"\">\n\t\t\t<div class=\"e-n-tabs-heading\" role=\"tablist\">\n\t\t\t\t\t<button id=\"e-n-tab-title-547649121\" class=\"e-n-tab-title\" aria-selected=\"true\" data-tab-index=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"e-n-tab-content-547649121\" style=\"--n-tabs-title-order: 1;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tDead Space\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-547649122\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-547649122\" style=\"--n-tabs-title-order: 2;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tKebocoran Udara dan Cairan\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-547649123\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-547649123\" style=\"--n-tabs-title-order: 3;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tKekuatan Operasi Piston\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-547649124\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-547649124\" style=\"--n-tabs-title-order: 4;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tKesesuaian dan Retensi Plunger\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t\t<\/div>\n\t\t\t<div class=\"e-n-tabs-content\">\n\t\t\t\t<div id=\"e-n-tab-content-547649121\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-547649121\" data-tab-index=\"1\" style=\"--n-tabs-title-order: 1;\" class=\"e-active elementor-element elementor-element-9d08f18 e-flex e-con-boxed e-con e-child\" data-id=\"9d08f18\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a7b7101 elementor-widget elementor-widget-text-editor\" data-id=\"a7b7101\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"347\" data-end=\"741\">Untuk mengurangi limbah obat dan meminimalkan risiko kontaminasi silang, ISO 7886-1 mensyaratkan bahwa ruang mati jarum suntik-volume cairan residu yang tersisa setelah penyisipan plunger penuh-harus dijaga agar tetap minimum.<\/p><p data-start=\"743\" data-end=\"1267\">\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-547649122\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-547649122\" data-tab-index=\"2\" style=\"--n-tabs-title-order: 2;\" class=\"elementor-element elementor-element-56c370d e-flex e-con-boxed e-con e-child\" data-id=\"56c370d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8f5102f elementor-widget elementor-widget-text-editor\" data-id=\"8f5102f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"743\" data-end=\"1267\">Alat suntik harus menunjukkan kinerja penyegelan yang kuat. Menurut <em data-start=\"850\" data-end=\"859\">Lampiran D<\/em>, seharusnya ada <strong data-start=\"877\" data-end=\"908\">tidak ada kebocoran air yang terlihat<\/strong> melewati sumbat pendorong atau segel di bawah kompresi. Meskipun tetesan kecil di antara segel internal diperbolehkan, kebocoran eksternal merupakan kegagalan. Selain itu, <em data-start=\"1076\" data-end=\"1085\">Lampiran B<\/em> mengamanatkan bahwa <strong data-start=\"1100\" data-end=\"1118\">tidak ada kebocoran udara<\/strong> atau penurunan tekanan vakum dapat terjadi selama pengujian aspirasi. Kriteria ini memastikan integritas penghalang jarum suntik dan aplikasi klinis yang aman.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-547649123\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-547649123\" data-tab-index=\"3\" style=\"--n-tabs-title-order: 3;\" class=\"elementor-element elementor-element-0debdba e-flex e-con-boxed e-con e-child\" data-id=\"0debdba\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-94d47e2 elementor-widget elementor-widget-text-editor\" data-id=\"94d47e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1269\" data-end=\"1702\">ISO 7886-1 merekomendasikan untuk memverifikasi gaya yang diperlukan untuk memulai dan mempertahankan gerakan plunger, karena kegunaan jarum suntik dan kontrol dosis bergantung padanya. <em data-start=\"1457\" data-end=\"1466\">Lampiran E<\/em> menyajikan sebuah metode untuk mengukur <strong data-start=\"1500\" data-end=\"1532\">melepaskan diri dan meluncur dengan gaya<\/strong> menggunakan sistem pengujian mekanis. Meskipun pengujian ini bersifat informatif dan bukannya wajib, namun memainkan peran penting dalam memastikan performa yang konsisten dan ramah pengguna.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-547649124\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-547649124\" data-tab-index=\"4\" style=\"--n-tabs-title-order: 4;\" class=\"elementor-element elementor-element-99198a0 e-flex e-con-boxed e-con e-child\" data-id=\"99198a0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d2653db elementor-widget elementor-widget-text-editor\" data-id=\"d2653db\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Sumbat penyumbat harus terpasang dengan kencang di dalam laras. Untuk memastikan hal ini, jarum suntik diisi hingga kapasitas nominalnya dan dipegang secara vertikal-baik secara tegak maupun terbalik. Dalam kedua orientasi tersebut, plunger harus <strong data-start=\"1945\" data-end=\"1979\">tidak bergerak karena beratnya sendiri<\/strong> atau berat air saja. Persyaratan ini melindungi dari gerakan yang tidak diinginkan yang dapat mengakibatkan kesalahan dosis atau kebocoran.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4835ce e-flex e-con-boxed e-con e-parent\" data-id=\"d4835ce\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea29382 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ea29382\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pengujian Fungsionalitas Jarum Suntik: Parameter Utama dan Metode Pengujian<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-55047da e-con-full e-flex e-con e-child\" data-id=\"55047da\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-ae8face e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"ae8face\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7c7cd83 elementor-widget elementor-widget-heading\" data-id=\"7c7cd83\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.syringetest.com\/id\/break-loose-and-glide-force-testing\/\">Pengujian Kekuatan Lepas dan Luncur<\/a><\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-42248e5 elementor-widget elementor-widget-text-editor\" data-id=\"42248e5\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1844\" data-end=\"2038\"><strong data-start=\"1844\" data-end=\"1855\">Lampiran E<\/strong> dari ISO 7886-1 menentukan metode untuk menentukan <em data-start=\"1911\" data-end=\"1924\">melepaskan diri<\/em> dan <em data-start=\"1929\" data-end=\"1942\">gaya luncur<\/em> diperlukan untuk mengoperasikan plunger. Gaya-gaya ini memengaruhi pengalaman pengguna dan kontrol dosis.<\/p><ul><li data-start=\"2042\" data-end=\"2112\"><a href=\"https:\/\/www.syringetest.com\/id\/break-loose-and-glide-force-testing\/\"><strong data-start=\"2042\" data-end=\"2063\">Mematahkan kekuatan lepas<\/strong><\/a> adalah gaya awal yang diperlukan untuk menggerakkan plunger.<\/li><li data-start=\"2115\" data-end=\"2188\"><a href=\"https:\/\/www.syringetest.com\/id\/break-loose-and-glide-force-testing\/\"><strong data-start=\"2115\" data-end=\"2130\">Gaya luncur<\/strong><\/a> adalah gaya rata-rata yang diperlukan untuk melanjutkan gerakan plunger.<\/li><\/ul><p data-start=\"2190\" data-end=\"2217\"><strong data-start=\"2190\" data-end=\"2217\">Sorotan Metode Pengujian:<\/strong><\/p><ul><li data-start=\"2220\" data-end=\"2329\">Gunakan sistem pengujian mekanis (misalnya, Cell Instruments' <strong data-start=\"2277\" data-end=\"2309\">MST-01 Penguji Jarum Suntik Medis<\/strong>) pada 100 \u00b1 5 mm\/menit.<\/li><li data-start=\"2332\" data-end=\"2369\">Isi jarum suntik dengan air pada suhu 23 \u00b1 5 \u00b0C.<\/li><li data-start=\"2372\" data-end=\"2457\">Hubungkan jarum suntik ke tabung dan keluarkan air sampai plunger mencapai tanda nominal.<\/li><li data-start=\"2460\" data-end=\"2467\">Catat:<ul><li data-start=\"2472\" data-end=\"2499\">Gaya gerakan awal (f\u209b)<\/li><li data-start=\"2504\" data-end=\"2525\">Gaya perjalanan rata-rata (F)<\/li><li data-start=\"2530\" data-end=\"2558\">Kekuatan resistensi puncak (Fmax)<\/li><\/ul><\/li><\/ul><p data-start=\"2560\" data-end=\"2677\"><em data-start=\"2560\" data-end=\"2677\">Performa luncuran yang konsisten memastikan kelancaran injeksi dan kenyamanan pengguna, menjadikannya tolok ukur kualitas yang sangat penting.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fda7334 e-con-full e-flex e-con e-child\" data-id=\"fda7334\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a601c24 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-image\" data-id=\"a601c24\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInRight&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"546\" height=\"719\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\" class=\"attachment-large size-large wp-image-613\" alt=\"ISO 7886-1 Lampiran E\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp 546w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E-228x300.webp 228w\" sizes=\"(max-width: 546px) 100vw, 546px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7ada073 e-con-full e-flex e-con e-child\" data-id=\"7ada073\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-61bbbd2 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"61bbbd2\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.syringetest.com\/id\/syringe-liquid-leakage-test-for-closure-system\/\">Deteksi Kebocoran Cairan pada Jarum Suntik (Di Bawah Kompresi)<\/a><\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e3eedc elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"0e3eedc\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2741\" data-end=\"2896\"><strong data-start=\"2741\" data-end=\"2752\">Lampiran D<\/strong> menguraikan metode untuk mendeteksi <a href=\"https:\/\/www.syringetest.com\/id\/syringe-liquid-leakage-test-for-closure-system\/\"><strong data-start=\"2781\" data-end=\"2799\">kebocoran cairan<\/strong><\/a> melewati <strong data-start=\"2809\" data-end=\"2833\">segel penghenti plunger<\/strong> selama kompresi-sebuah indikator penting keandalan jarum suntik.<\/p><p data-start=\"2898\" data-end=\"2915\"><strong data-start=\"2898\" data-end=\"2915\">Proses Pengujian:<\/strong><\/p><ul><li data-start=\"2918\" data-end=\"2985\">Isi jarum suntik hingga volume nominal dengan air suling (18-28 \u00b0C).<\/li><li data-start=\"2988\" data-end=\"3049\">Tutup nosel jarum suntik menggunakan alat kelengkapan yang sesuai dengan ISO 80369-7.<\/li><li data-start=\"3052\" data-end=\"3098\">Terapkan gaya lateral (0,25-3 N) ke plunger.<\/li><li data-start=\"3101\" data-end=\"3163\">Terapkan gaya aksial untuk menghasilkan tekanan internal (200-300 kPa).<\/li><li data-start=\"3166\" data-end=\"3193\">Pertahankan selama 30-35 detik.<\/li><li data-start=\"3196\" data-end=\"3238\">Periksa apakah ada cairan yang keluar dari laras.<\/li><\/ul><p data-start=\"3240\" data-end=\"3361\">Instrumen Sel menawarkan <strong data-start=\"3268\" data-end=\"3298\">Penguji Kebocoran Jarum Suntik SLT-02<\/strong>yang ideal untuk kontrol tekanan yang tepat dan pengamatan waktu nyata.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb1aef4 e-con-full e-flex e-con e-child\" data-id=\"cb1aef4\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-64a5239 e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"64a5239\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c50402d elementor-widget elementor-widget-heading\" data-id=\"c50402d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Deteksi Kebocoran Udara pada Jarum Suntik (Selama Aspirasi)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b9b9803 elementor-widget elementor-widget-text-editor\" data-id=\"b9b9803\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3422\" data-end=\"3549\"><strong data-start=\"3422\" data-end=\"3433\">Lampiran B<\/strong> mendefinisikan prosedur untuk <strong data-start=\"3457\" data-end=\"3490\">deteksi kebocoran udara pada jarum suntik<\/strong> dan memverifikasi retensi sumbat plunger selama aspirasi.<\/p><p data-start=\"3551\" data-end=\"3565\"><strong data-start=\"3551\" data-end=\"3565\">Prosedur:<\/strong><\/p><ul><li data-start=\"3568\" data-end=\"3635\">Isi sebagian jarum suntik dengan air dan tarik plunger ke tanda nominal.<\/li><li data-start=\"3638\" data-end=\"3690\">Kencangkan plunger dan sambungkan jarum suntik ke sistem vakum.<\/li><li data-start=\"3693\" data-end=\"3736\">Menghasilkan 88 kPa di bawah tekanan atmosfer.<\/li><li data-start=\"3739\" data-end=\"3762\">Amati selama 60 detik:<ul><li data-start=\"3767\" data-end=\"3810\">Penurunan tekanan manometer (mengindikasikan kebocoran)<\/li><li data-start=\"3815\" data-end=\"3848\">Pelepasan atau ketidakstabilan plunger<\/li><\/ul><\/li><\/ul><p data-start=\"3850\" data-end=\"3955\">Kekedapan udara memastikan akurasi dosis dan mencegah kontaminasi-membuat tes ini penting untuk penggunaan yang aman.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a4bf01b e-con-full e-flex e-con e-child\" data-id=\"a4bf01b\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-812ae93 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-image\" data-id=\"812ae93\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInRight&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"694\" height=\"570\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B.webp\" class=\"attachment-large size-large wp-image-614\" alt=\"ISO 7886-1 Lampiran B\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B.webp 694w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B-300x246.webp 300w\" sizes=\"(max-width: 694px) 100vw, 694px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-41ab1d6 e-con-full e-flex e-con e-parent\" data-id=\"41ab1d6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-48c60fb elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"48c60fb\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Memilih Peralatan Pengujian Jarum Suntik yang Tepat<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-57384eb e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"57384eb\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInUp&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ffb5df1 eael-infobox-content-align--center eael-infobox-shape-square eael-infobox-hover-img-shape-square elementor-widget elementor-widget-eael-info-box\" data-id=\"ffb5df1\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"eael-info-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-infobox icon-on-top\">\n\t            <div class=\"infobox-icon\">\n\n                            <img decoding=\"async\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-B-air-leakage-test-for-syringe.webp\" alt=\"ISO 7886-1 Lampiran B uji kebocoran udara untuk jarum suntik\">\n            \n            \n            \n        <\/div>\n            <div class=\"infobox-content\">\n                    <div class=\"infobox-title-section\">\n                <h3 class=\"title\">Penguji Kebocoran Jarum Suntik SLT-02<\/h3>            <\/div>\n            <div><p data-start=\"0\" data-end=\"483\">Instrumen ini secara tepat menerapkan vakum terkendali pada jarum suntik, memungkinkan pemantauan perubahan tekanan dan integritas plunger secara akurat. Didesain dengan koneksi yang kompatibel dengan ISO 80369-7 dan mekanisme penjepitan yang aman, SLT-01 memastikan evaluasi menyeluruh terhadap kekedapan udara dan retensi sumbat plunger.<\/p><p data-start=\"485\" data-end=\"945\">\u00a0<\/p><\/div>        <\/div>\n            <\/div>\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c042898 eael-infobox-content-align--center eael-infobox-shape-square eael-infobox-hover-img-shape-square elementor-widget elementor-widget-eael-info-box\" data-id=\"c042898\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"eael-info-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-infobox icon-on-top\">\n\t            <div class=\"infobox-icon\">\n\n                            <img decoding=\"async\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E-syringe-glide-force-tester.webp\" alt=\"ISO 7886-1 Lampiran E penguji gaya luncur jarum suntik\">\n            \n            \n            \n        <\/div>\n            <div class=\"infobox-content\">\n                    <div class=\"infobox-title-section\">\n                <h2 class=\"title\">MST-01 Penguji Jarum Suntik Medis<\/h2>            <\/div>\n            <div><p data-start=\"485\" data-end=\"945\">Alat ini menggunakan sistem mekanis presisi tinggi untuk mengukur gaya lepas dan gaya luncur selama pengeluaran cairan. MST-01 memungkinkan produsen untuk mengukur inisiasi dan resistensi perjalanan, memberikan data penting untuk memastikan gerakan plunger yang mulus dan konsisten - sangat penting untuk keamanan dan kenyamanan.<\/p><p data-start=\"947\" data-end=\"1407\" data-is-last-node=\"\" data-is-only-node=\"\">\u00a0<\/p><\/div>        <\/div>\n            <\/div>\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a5ad445 eael-infobox-content-align--center eael-infobox-shape-square eael-infobox-hover-img-shape-square elementor-widget elementor-widget-eael-info-box\" data-id=\"a5ad445\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"eael-info-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-infobox icon-on-top\">\n\t            <div class=\"infobox-icon\">\n\n                            <img decoding=\"async\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-D-liquid-leakage-at-syringe-plunger-stopper-under-compression.webp\" alt=\"ISO 7886-1 Lampiran D Kebocoran cairan pada sumbat penyumbat jarum suntik di bawah kompresi\">\n            \n            \n            \n        <\/div>\n            <div class=\"infobox-content\">\n                    <div class=\"infobox-title-section\">\n                <h2 class=\"title\">Penguji Kekencangan Jarum Suntik SPPT-01<\/h2>            <\/div>\n            <div><p>Perangkat ini mensimulasikan tekanan di dalam laras jarum suntik sambil memberikan beban lateral dan aksial pada plunger, yang secara dekat mereplikasi kondisi penggunaan klinis. SSPT-01 dirancang untuk mendeteksi kegagalan segel yang tidak kentara sekalipun, sehingga membantu produsen memverifikasi keandalan produk dan kepatuhan terhadap standar keamanan yang ketat.<\/p><\/div>        <\/div>\n            <\/div>\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad468be e-flex e-con-boxed e-con e-parent\" data-id=\"ad468be\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-edb7717 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"edb7717\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mengapa Kepatuhan ISO 7886-1 Penting<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5810d33 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"5810d33\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4571\" data-end=\"4657\">Mematuhi ISO 7886-1 memastikan bahwa jarum suntik:<\/p><ul><li data-start=\"4660\" data-end=\"4682\">Memberikan dosis yang akurat<\/li><li data-start=\"4685\" data-end=\"4713\">Aman dan mudah dioperasikan<\/li><li data-start=\"4716\" data-end=\"4740\">Tetap tersegel selama penggunaan<\/li><li data-start=\"4743\" data-end=\"4789\">Memenuhi persyaratan peraturan dan ekspor global<\/li><\/ul><p data-start=\"4791\" data-end=\"4910\">Mengabaikan yang benar <strong data-start=\"4809\" data-end=\"4842\">pengujian fungsionalitas jarum suntik<\/strong> dapat menyebabkan penarikan produk, penalti peraturan, atau bahaya bagi pasien.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b581cc e-con-full e-flex e-con e-parent\" data-id=\"1b581cc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-61afd37 e-grid e-con-full e-con e-child\" data-id=\"61afd37\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-f8ace73 e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"f8ace73\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94cc5ad e-flex e-con-boxed elementor-invisible e-con e-child\" data-id=\"94cc5ad\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInRight&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-907b713 elementor-widget elementor-widget-heading\" data-id=\"907b713\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mengapa Memilih <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-718f32f elementor-widget elementor-widget-text-editor\" data-id=\"718f32f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4917\" data-end=\"5240\">Memahami dan menerapkan <strong data-start=\"4961\" data-end=\"4975\">ISO 7886-1<\/strong> Metode pengujian sangat penting bagi perusahaan yang terlibat dalam produksi jarum suntik atau kontrol kualitas. Dari <strong data-start=\"5077\" data-end=\"5116\">pengujian gaya lepas dan meluncur<\/strong> untuk <strong data-start=\"5120\" data-end=\"5153\">deteksi kebocoran udara dan cairan<\/strong>setiap pengujian memiliki peran khusus dalam menjaga keandalan produk dan keselamatan pengguna.<\/p><p data-start=\"5242\" data-end=\"5537\"><strong>Syringetest.com<\/strong> menyediakan tingkat lanjut <strong data-start=\"5281\" data-end=\"5310\">peralatan pengujian jarum suntik<\/strong> dirancang untuk mendukung kepatuhan lengkap dan alur kerja QC yang efisien. Jika Anda ingin meningkatkan proses validasi jarum suntik atau meningkatkan akurasi pengujian, hubungi kami untuk mengetahui bagaimana instrumen kami dapat membantu memenuhi standar Anda.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f735b94 elementor-widget elementor-widget-eael-creative-button\" data-id=\"f735b94\" data-element_type=\"widget\" data-widget_type=\"eael-creative-button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-creative-button-wrapper\">\n\n            <a class=\"eael-creative-button eael-creative-button--default\" href=\"#\" data-text=\"Contact Us\">\n\n\t    \n                <div class=\"creative-button-inner\">\n\n                    \n                    <span class=\"cretive-button-text\">Hubungi Kami<\/span>\n\n                                    <\/div>\n\t                        <\/a>\n        <\/div>\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 7886-1 Syringe Functionality Testing Standard ISO 7886-1 is the internationally recognized standard that defines the performance and testing requirements for sterile hypodermic syringes for single use, intended for manual operation. This standard plays a vital role in syringe quality control, ensuring functional safety and patient protection. Quality control engineers and regulatory specialists rely on [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"parent":603,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-608","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 7886-1 Syringe Functionality Testing and Testing Equipment<\/title>\n<meta name=\"description\" content=\"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.syringetest.com\/id\/standards\/iso-7886-1\/\" \/>\n<meta property=\"og:locale\" content=\"id_ID\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 7886-1 Syringe Functionality Testing and Testing Equipment\" \/>\n<meta property=\"og:description\" content=\"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.syringetest.com\/id\/standards\/iso-7886-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Syringe and Needle Testing\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-02T07:28:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"546\" \/>\n\t<meta property=\"og:image:height\" content=\"719\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimasi waktu membaca\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 menit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1\",\"url\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1\",\"name\":\"ISO 7886-1 Syringe Functionality Testing and Testing Equipment\",\"isPartOf\":{\"@id\":\"https:\/\/www.syringetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\",\"datePublished\":\"2025-07-02T05:36:28+00:00\",\"dateModified\":\"2025-07-02T07:28:27+00:00\",\"description\":\"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#breadcrumb\"},\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.syringetest.com\/standards\/iso-7886-1\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.syringetest.com\/standards\/iso-7886-1#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.syringetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Standards\",\"item\":\"https:\/\/www.syringetest.com\/standards\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ISO 7886-1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.syringetest.com\/#website\",\"url\":\"https:\/\/www.syringetest.com\/\",\"name\":\"Syringe and Needle Testing\",\"description\":\"Syringe and Needle Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.syringetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.syringetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.syringetest.com\/#organization\",\"name\":\"Syringe and Needle Testing\",\"url\":\"https:\/\/www.syringetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"width\":512,\"height\":512,\"caption\":\"Syringe and Needle Testing\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 7886-1 Syringe Functionality Testing and Testing Equipment","description":"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.syringetest.com\/id\/standards\/iso-7886-1\/","og_locale":"id_ID","og_type":"article","og_title":"ISO 7886-1 Syringe Functionality Testing and Testing Equipment","og_description":"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.","og_url":"https:\/\/www.syringetest.com\/id\/standards\/iso-7886-1\/","og_site_name":"Syringe and Needle Testing","article_modified_time":"2025-07-02T07:28:27+00:00","og_image":[{"width":546,"height":719,"url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimasi waktu membaca":"6 menit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1","url":"https:\/\/www.syringetest.com\/standards\/iso-7886-1","name":"ISO 7886-1 Syringe Functionality Testing and Testing Equipment","isPartOf":{"@id":"https:\/\/www.syringetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage"},"image":{"@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage"},"thumbnailUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp","datePublished":"2025-07-02T05:36:28+00:00","dateModified":"2025-07-02T07:28:27+00:00","description":"ISO 7886-1 including break loose and glide force testing, air and liquid leak detection. And related syringe testing equipment.","breadcrumb":{"@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#breadcrumb"},"inLanguage":"id","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.syringetest.com\/standards\/iso-7886-1"]}]},{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#primaryimage","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/07\/ISO-7886-1-Annex-E.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.syringetest.com\/standards\/iso-7886-1#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.syringetest.com\/"},{"@type":"ListItem","position":2,"name":"Standards","item":"https:\/\/www.syringetest.com\/standards"},{"@type":"ListItem","position":3,"name":"ISO 7886-1"}]},{"@type":"WebSite","@id":"https:\/\/www.syringetest.com\/#website","url":"https:\/\/www.syringetest.com\/","name":"Syringe and Needle Testing","description":"Syringe and Needle Test Solutions","publisher":{"@id":"https:\/\/www.syringetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.syringetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id"},{"@type":"Organization","@id":"https:\/\/www.syringetest.com\/#organization","name":"Syringe and Needle Testing","url":"https:\/\/www.syringetest.com\/","logo":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","width":512,"height":512,"caption":"Syringe and Needle Testing"},"image":{"@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages\/608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/comments?post=608"}],"version-history":[{"count":5,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages\/608\/revisions"}],"predecessor-version":[{"id":627,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages\/608\/revisions\/627"}],"up":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages\/603"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/media?parent=608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}