{"id":265,"date":"2025-05-06T03:29:29","date_gmt":"2025-05-06T03:29:29","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=265"},"modified":"2025-05-06T03:56:17","modified_gmt":"2025-05-06T03:56:17","slug":"luer-lock-adaptor-collar-pull-off-force","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/id\/luer-lock-adaptor-collar-pull-off-force","title":{"rendered":"Gaya Tarik Kerah Adaptor Kunci Luer"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"265\" class=\"elementor elementor-265\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-292be0b e-flex e-con-boxed e-con e-parent\" data-id=\"292be0b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0f48abd elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"0f48abd\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Gaya Tarik Kerah Adaptor Kunci Luer<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6817f29 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"6817f29\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dalam industri farmasi dan alat kesehatan, memastikan integritas komponen jarum suntik sangat penting. Salah satu pemeriksaan kualitas yang penting adalah tes ini. Evaluasi ini mengukur kekuatan sambungan antara kerah adaptor kunci Luer (LLA) dan laras jarum suntik, mencegah pemisahan komponen selama penggunaan.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad68bc6 e-flex e-con-boxed e-con e-parent\" data-id=\"ad68bc6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ecf369e elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ecf369e\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pentingnya Pengujian Gaya Tarik Kerah Adaptor Kunci Luer<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f390758 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"f390758\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Jika gaya tarik kerah adaptor kunci Luer terlalu rendah, kerah dapat terlepas dari jarum suntik selama penanganan atau penyuntikan, yang menyebabkan kebocoran obat, dosis yang tidak lengkap, atau bahkan cedera pasien yang serius. Di sisi lain, jika gaya terlalu tinggi, proses perakitan dapat menjadi sulit, sehingga meningkatkan risiko kerusakan selama pembuatan.<\/p><p>Oleh karena itu, melakukan pengujian standar ini sangat penting untuk memastikan pemasangan kerah yang aman, menjaga keandalan fungsional jarum suntik, dan melindungi keselamatan pasien.<\/p><p><strong>Syringetest.com<\/strong> menawarkan peralatan pengujian yang tepat dan andal untuk <em>Gaya tarik kerah adaptor kunci Luer<\/em> membantu memastikan jarum suntik Anda memenuhi standar kualitas global dengan penuh percaya diri.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4835ce e-flex e-con-boxed e-con e-parent\" data-id=\"d4835ce\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea29382 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ea29382\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 dan ISO 11040-4 Lampiran G3<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-55047da e-con-full e-flex e-con e-child\" data-id=\"55047da\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-ae8face e-con-full e-flex e-con e-child\" data-id=\"ae8face\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-42248e5 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"42248e5\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInLeft&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/www.syringetest.com\/id\/standards\/iso-11040-4\/\"><em>ISO 11040-4<\/em><\/a> standar, khususnya <em>ISO 11040-4 Lampiran G3<\/em>menguraikan prosedur untuk <em>Gaya tarik kerah adaptor kunci Luer<\/em> uji. Menurut standar ini, uji gaya tarik memverifikasi kemampuan sistem kerah untuk menahan gaya aksial, memastikan bahwa jarum suntik tetap utuh selama operasi penting seperti pemberian obat. Metode ini menekankan kecepatan pengujian yang konsisten, pemilihan sel beban yang tepat, dan pengambilan sampel frekuensi tinggi untuk memastikan data yang akurat dan andal.<\/p><p>Mengikuti <em>ISO 11040-4 Lampiran G3<\/em> meningkatkan konsistensi pengujian di seluruh laboratorium dan produsen, sehingga menumbuhkan kepercayaan terhadap kualitas produk dan kepatuhan terhadap peraturan.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fda7334 e-con-full e-flex e-con e-child\" data-id=\"fda7334\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a601c24 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-image\" data-id=\"a601c24\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInRight&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"515\" height=\"350\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" class=\"attachment-large size-large wp-image-272\" alt=\"Gaya Tarik Kerah Adaptor Kunci Luer - ISO 11040-4 Lampiran G3\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp 515w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing-300x204.webp 300w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-41ab1d6 e-flex e-con-boxed e-con e-parent\" data-id=\"41ab1d6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-48c60fb elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"48c60fb\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prinsip Uji Gaya Tarik-Lepas Kerah Adaptor Kunci Luer<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c5b3e59 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"c5b3e59\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ide inti di balik tes ini sederhana: tes ini mengukur gaya aksial maksimum yang diperlukan untuk melepaskan kerah LLA dari laras jarum suntik. Gaya tarik yang kuat berarti kerah LLA terpasang dengan aman, sehingga meminimalkan risiko terlepasnya kerah saat digunakan.<\/p><p>Prinsip utama berfokus pada:<\/p><ul><li>Mensimulasikan tekanan mekanis yang realistis.<\/li><li>Memastikan bahwa gaya penyisipan dari fitting Luer standar tidak menyebabkan kerah terlepas.<\/li><li>Mengumpulkan data gaya puncak melalui analisis gaya versus perpindahan.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad468be e-flex e-con-boxed e-con e-parent\" data-id=\"ad468be\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-edb7717 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"edb7717\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Peralatan dan Bahan yang Diperlukan<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5810d33 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"5810d33\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pengujian yang akurat dari <em>Gaya tarik kerah adaptor kunci Luer<\/em> menuntut peralatan yang presisi:<\/p><ul><li><strong>Mesin uji tarik dan kompresi universal <\/strong>dengan:<ul><li>Kecepatan uji ditetapkan pada 20 mm\/menit (sesuai ISO 80369-7, jika sesuai).<\/li><li>Load cell cocok untuk rentang gaya 10 N hingga 100 N.<\/li><\/ul><\/li><li><strong>Tempat jarum suntik dan perangkat pencengkeram<\/strong> yang mengamankan laras jarum suntik dan kerah LLA tanpa memberikan tekanan yang tidak diinginkan.<\/li><\/ul><p><strong>Bahan:<\/strong><\/p><ul><li>Jarum suntik rakitan yang telah disterilkan dan siap diisi, termasuk sistem LLA.<\/li><\/ul><p><strong>Penting:<\/strong><br \/>Laju sampling harus tidak kurang dari 100 Hz untuk pengujian umum, dan 500 Hz untuk pengukuran puncak, untuk memastikan resolusi dan akurasi data yang baik.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-285667c e-con-full e-flex e-con e-parent\" data-id=\"285667c\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f7c629 elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"3f7c629\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prosedur Uji Gaya Tarik Kerah Adaptor Kunci Luer<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f6e7fda elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"f6e7fda\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Melakukan tes ini dengan benar akan memastikan hasil yang akurat dan dapat diulang:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d737d1 e-n-tabs-mobile elementor-invisible elementor-widget elementor-widget-n-tabs\" data-id=\"9d737d1\" data-element_type=\"widget\" data-settings=\"{&quot;tabs_justify_horizontal&quot;:&quot;center&quot;,&quot;_animation&quot;:&quot;fadeInUp&quot;,&quot;horizontal_scroll&quot;:&quot;disable&quot;}\" data-widget_type=\"nested-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-tabs\" data-widget-number=\"165099473\" aria-label=\"Registerkarten. \u00d6ffnen Sie Elemente mit Enter oder Space, schlie\u00dfen Sie sie mit Escape und navigieren Sie mit den Pfeiltasten.\" data-no-translation-aria-label=\"\">\n\t\t\t<div class=\"e-n-tabs-heading\" role=\"tablist\">\n\t\t\t\t\t<button id=\"e-n-tab-title-1650994731\" class=\"e-n-tab-title\" aria-selected=\"true\" data-tab-index=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"e-n-tab-content-1650994731\" style=\"--n-tabs-title-order: 1;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t1. Persiapan Sampel\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1650994732\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1650994732\" style=\"--n-tabs-title-order: 2;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t2. Pengaturan\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1650994733\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1650994733\" style=\"--n-tabs-title-order: 3;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t3. Eksekusi Tes\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1650994734\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1650994734\" style=\"--n-tabs-title-order: 4;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t4. Mengakhiri Tes\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1650994735\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"5\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1650994735\" style=\"--n-tabs-title-order: 5;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t5. Pencatatan Hasil\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t\t<\/div>\n\t\t\t<div class=\"e-n-tabs-content\">\n\t\t\t\t<div id=\"e-n-tab-content-1650994731\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994731\" data-tab-index=\"1\" style=\"--n-tabs-title-order: 1;\" class=\"e-active elementor-element elementor-element-e75ed08 e-flex e-con-boxed e-con e-child\" data-id=\"e75ed08\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f3434b1 elementor-widget elementor-widget-text-editor\" data-id=\"f3434b1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Gunakan jarum suntik yang telah melalui proses sterilisasi dan persiapan penuh.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1650994732\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994732\" data-tab-index=\"2\" style=\"--n-tabs-title-order: 2;\" class=\"elementor-element elementor-element-f886d7d e-flex e-con-boxed e-con e-child\" data-id=\"f886d7d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f5549bf elementor-widget elementor-widget-text-editor\" data-id=\"f5549bf\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Lepaskan tutup ujung dengan hati-hati.<\/li><li>Kencangkan jarum suntik secara vertikal di antara penahan (flensa jari) dan pencengkeram (kerah LLA) tanpa menekan kerah.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1650994733\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994733\" data-tab-index=\"3\" style=\"--n-tabs-title-order: 3;\" class=\"elementor-element elementor-element-8a12e10 e-flex e-con-boxed e-con e-child\" data-id=\"8a12e10\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3c766c8 elementor-widget elementor-widget-text-editor\" data-id=\"3c766c8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Atur sel beban ke nol, pastikan tidak ada beban awal.<\/li><li>Terapkan gaya tarikan pada 20 mm\/menit.<\/li><li>Catat kurva gaya versus perpindahan secara terus-menerus.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1650994734\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994734\" data-tab-index=\"4\" style=\"--n-tabs-title-order: 4;\" class=\"elementor-element elementor-element-b3f1f40 e-flex e-con-boxed e-con e-child\" data-id=\"b3f1f40\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-904eb23 elementor-widget elementor-widget-text-editor\" data-id=\"904eb23\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Hentikan tes ketika kerah LLA terpisah dengan jelas dari jarum suntik.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1650994735\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994735\" data-tab-index=\"5\" style=\"--n-tabs-title-order: 5;\" class=\"elementor-element elementor-element-af75195 e-flex e-con-boxed e-con e-child\" data-id=\"af75195\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f9a6a49 elementor-widget elementor-widget-text-editor\" data-id=\"f9a6a49\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Puncak gaya maksimum pada kurva mewakili <em>gaya tarik<\/em>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b581cc e-con-full e-flex e-con e-parent\" data-id=\"1b581cc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-61afd37 e-grid e-con-full e-con e-child\" data-id=\"61afd37\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-f8ace73 e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"f8ace73\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94cc5ad e-flex e-con-boxed elementor-invisible e-con e-child\" data-id=\"94cc5ad\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInRight&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-907b713 elementor-widget elementor-widget-heading\" data-id=\"907b713\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mengapa Memilih <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-718f32f elementor-widget elementor-widget-text-editor\" data-id=\"718f32f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Melakukan proses <em>Gaya tarik kerah adaptor kunci Luer<\/em> uji menurut <em>ISO 11040-4 Lampiran G3<\/em> sangat penting untuk memastikan keamanan mekanis jarum suntik kunci Luer. Pelaksanaan dan dokumentasi yang tepat memberikan jaminan bahwa jarum suntik dapat bertahan dalam tekanan penggunaan klinis tanpa kegagalan.<br \/>Mengandalkan <strong>Syringetest.com<\/strong> untuk solusi pengujian mutakhir yang meningkatkan kualitas dan keamanan produk jarum suntik Anda.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f735b94 elementor-widget elementor-widget-eael-creative-button\" data-id=\"f735b94\" data-element_type=\"widget\" data-widget_type=\"eael-creative-button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-creative-button-wrapper\">\n\n            <a class=\"eael-creative-button eael-creative-button--default\" href=\"#\" data-text=\"Contact Us\">\n\n\t    \n                <div class=\"creative-button-inner\">\n\n                    \n                    <span class=\"cretive-button-text\">Hubungi Kami<\/span>\n\n                                    <\/div>\n\t                        <\/a>\n        <\/div>\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Adaptor Collar Pull-Off Force In the pharmaceutical and medical device industries, ensuring the integrity of syringe components is critical. One essential quality check is the this test. This evaluation measures the strength of the connection between the Luer lock adaptor (LLA) collar and the syringe barrel, preventing component separation during use. The Importance [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-265","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3<\/title>\n<meta name=\"description\" content=\"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.syringetest.com\/id\/luer-lock-adaptor-collar-pull-off-force\/\" \/>\n<meta property=\"og:locale\" content=\"id_ID\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3\" \/>\n<meta property=\"og:description\" content=\"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.syringetest.com\/id\/luer-lock-adaptor-collar-pull-off-force\/\" \/>\n<meta property=\"og:site_name\" content=\"Syringe and Needle Testing\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-06T03:56:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"515\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimasi waktu membaca\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 menit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force\",\"url\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force\",\"name\":\"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3\",\"isPartOf\":{\"@id\":\"https:\/\/www.syringetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\",\"datePublished\":\"2025-05-06T03:29:29+00:00\",\"dateModified\":\"2025-05-06T03:56:17+00:00\",\"description\":\"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#breadcrumb\"},\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.syringetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Luer Lock Adaptor Collar Pull-Off Force\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.syringetest.com\/#website\",\"url\":\"https:\/\/www.syringetest.com\/\",\"name\":\"Syringe and Needle Testing\",\"description\":\"Syringe and Needle Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.syringetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.syringetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.syringetest.com\/#organization\",\"name\":\"Syringe and Needle Testing\",\"url\":\"https:\/\/www.syringetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"width\":512,\"height\":512,\"caption\":\"Syringe and Needle Testing\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3","description":"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.syringetest.com\/id\/luer-lock-adaptor-collar-pull-off-force\/","og_locale":"id_ID","og_type":"article","og_title":"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3","og_description":"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.","og_url":"https:\/\/www.syringetest.com\/id\/luer-lock-adaptor-collar-pull-off-force\/","og_site_name":"Syringe and Needle Testing","article_modified_time":"2025-05-06T03:56:17+00:00","og_image":[{"width":515,"height":350,"url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimasi waktu membaca":"4 menit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force","url":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force","name":"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3","isPartOf":{"@id":"https:\/\/www.syringetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage"},"image":{"@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage"},"thumbnailUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp","datePublished":"2025-05-06T03:29:29+00:00","dateModified":"2025-05-06T03:56:17+00:00","description":"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.","breadcrumb":{"@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#breadcrumb"},"inLanguage":"id","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force"]}]},{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.syringetest.com\/"},{"@type":"ListItem","position":2,"name":"Luer Lock Adaptor Collar Pull-Off Force"}]},{"@type":"WebSite","@id":"https:\/\/www.syringetest.com\/#website","url":"https:\/\/www.syringetest.com\/","name":"Syringe and Needle Testing","description":"Syringe and Needle Test Solutions","publisher":{"@id":"https:\/\/www.syringetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.syringetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id"},{"@type":"Organization","@id":"https:\/\/www.syringetest.com\/#organization","name":"Syringe and Needle Testing","url":"https:\/\/www.syringetest.com\/","logo":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","width":512,"height":512,"caption":"Syringe and Needle Testing"},"image":{"@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages\/265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/comments?post=265"}],"version-history":[{"count":5,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages\/265\/revisions"}],"predecessor-version":[{"id":275,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages\/265\/revisions\/275"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/media?parent=265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}