{"id":265,"date":"2025-05-06T03:29:29","date_gmt":"2025-05-06T03:29:29","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=265"},"modified":"2026-05-09T06:39:48","modified_gmt":"2026-05-09T06:39:48","slug":"luer-lock-adaptor-collar-pull-off-force","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/id\/luer-lock-adaptor-collar-pull-off-force","title":{"rendered":"Gaya Tarik Kerah Adaptor Kunci Luer"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"265\" class=\"elementor elementor-265\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0ebe6b e-flex e-con-boxed e-con e-parent\" data-id=\"c0ebe6b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d6d91c9 elementor-widget elementor-widget-heading\" data-id=\"d6d91c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Gaya Tarik Kerah Adaptor Kunci Luer<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0a5f59 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"f0a5f59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dalam industri farmasi dan alat kesehatan, memastikan integritas komponen jarum suntik sangat penting. Salah satu pemeriksaan kualitas yang penting adalah tes ini. Evaluasi ini mengukur kekuatan sambungan antara kerah adaptor kunci Luer (LLA) dan laras jarum suntik, mencegah pemisahan komponen selama penggunaan.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7e51b6e e-flex e-con-boxed e-con e-parent\" data-id=\"7e51b6e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a359504 elementor-widget elementor-widget-heading\" data-id=\"a359504\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pentingnya Pengujian Gaya Tarik Kerah Adaptor Kunci Luer<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de744c7 elementor-widget elementor-widget-text-editor\" data-id=\"de744c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Jika gaya tarik kerah adaptor kunci Luer terlalu rendah, kerah dapat terlepas dari jarum suntik selama penanganan atau penyuntikan, yang menyebabkan kebocoran obat, dosis yang tidak lengkap, atau bahkan cedera pasien yang serius. Di sisi lain, jika gaya terlalu tinggi, proses perakitan dapat menjadi sulit, sehingga meningkatkan risiko kerusakan selama pembuatan.<\/p><p>Oleh karena itu, melakukan pengujian standar ini sangat penting untuk memastikan pemasangan kerah yang aman, menjaga keandalan fungsional jarum suntik, dan melindungi keselamatan pasien.<\/p><p><strong>Syringetest.com<\/strong> menawarkan peralatan pengujian yang tepat dan andal untuk <em>Gaya tarik kerah adaptor kunci Luer<\/em> membantu memastikan jarum suntik Anda memenuhi standar kualitas global dengan penuh percaya diri.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f3ad5f2 e-flex e-con-boxed e-con e-parent\" data-id=\"f3ad5f2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d69bf22 elementor-widget elementor-widget-heading\" data-id=\"d69bf22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 dan ISO 11040-4 Lampiran G3<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c32614c e-con-full e-flex e-con e-child\" data-id=\"c32614c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fcd1b36 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"fcd1b36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/www.syringetest.com\/id\/standards\/iso-11040-4\/\"><em>ISO 11040-4<\/em><\/a> standar, khususnya <em>ISO 11040-4 Lampiran G3<\/em>menguraikan prosedur untuk <em>Gaya tarik kerah adaptor kunci Luer<\/em> uji. Menurut standar ini, uji gaya tarik memverifikasi kemampuan sistem kerah untuk menahan gaya aksial, memastikan bahwa jarum suntik tetap utuh selama operasi penting seperti pemberian obat. Metode ini menekankan kecepatan pengujian yang konsisten, pemilihan sel beban yang tepat, dan pengambilan sampel frekuensi tinggi untuk memastikan data yang akurat dan andal.<\/p><p>Mengikuti <em>ISO 11040-4 Lampiran G3<\/em> meningkatkan konsistensi pengujian di seluruh laboratorium dan produsen, sehingga menumbuhkan kepercayaan terhadap kualitas produk dan kepatuhan terhadap peraturan.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0502b44 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"0502b44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"515\" height=\"350\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" class=\"attachment-medium_large size-medium_large wp-image-272\" alt=\"Gaya Tarik Kerah Adaptor Kunci Luer - ISO 11040-4 Lampiran G3\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp 515w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing-300x204.webp 300w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c33ea3f e-flex e-con-boxed e-con e-parent\" data-id=\"c33ea3f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b8731e5 elementor-widget elementor-widget-heading\" data-id=\"b8731e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prinsip Uji Gaya Tarik-Lepas Kerah Adaptor Kunci Luer<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-931bcc4 elementor-widget elementor-widget-text-editor\" data-id=\"931bcc4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ide inti di balik tes ini sederhana: tes ini mengukur gaya aksial maksimum yang diperlukan untuk melepaskan kerah LLA dari laras jarum suntik. Gaya tarik yang kuat berarti kerah LLA terpasang dengan aman, sehingga meminimalkan risiko terlepasnya kerah saat digunakan.<\/p><p>Prinsip utama berfokus pada:<\/p><ul><li>Mensimulasikan tekanan mekanis yang realistis.<\/li><li>Memastikan bahwa gaya penyisipan dari fitting Luer standar tidak menyebabkan kerah terlepas.<\/li><li>Mengumpulkan data gaya puncak melalui analisis gaya versus perpindahan.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cbb1f00 e-flex e-con-boxed e-con e-parent\" data-id=\"cbb1f00\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9e34cbf elementor-widget elementor-widget-heading\" data-id=\"9e34cbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Peralatan dan Bahan yang Diperlukan<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29c5058 elementor-widget elementor-widget-text-editor\" data-id=\"29c5058\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pengujian yang akurat dari <em>Gaya tarik kerah adaptor kunci Luer<\/em> menuntut peralatan yang presisi:<\/p><ul><li><strong>Mesin uji tarik dan kompresi universal <\/strong>dengan:<ul><li>Kecepatan uji ditetapkan pada 20 mm\/menit (sesuai ISO 80369-7, jika sesuai).<\/li><li>Load cell cocok untuk rentang gaya 10 N hingga 100 N.<\/li><\/ul><\/li><li><strong>Tempat jarum suntik dan perangkat pencengkeram<\/strong> yang mengamankan laras jarum suntik dan kerah LLA tanpa memberikan tekanan yang tidak diinginkan.<\/li><\/ul><p><strong>Bahan:<\/strong><\/p><ul><li>Jarum suntik rakitan yang telah disterilkan dan siap diisi, termasuk sistem LLA.<\/li><\/ul><p><strong>Penting:<\/strong><br \/>Laju sampling harus tidak kurang dari 100 Hz untuk pengujian umum, dan 500 Hz untuk pengukuran puncak, untuk memastikan resolusi dan akurasi data yang baik.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-61d3079 e-flex e-con-boxed e-con e-parent\" data-id=\"61d3079\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bd94a54 elementor-widget elementor-widget-heading\" data-id=\"bd94a54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prosedur Uji Gaya Tarik Kerah Adaptor Kunci Luer<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc41e63 elementor-widget elementor-widget-text-editor\" data-id=\"fc41e63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Melakukan tes ini dengan benar akan memastikan hasil yang akurat dan dapat diulang:<\/p><h3>1. Persiapan Sampel<\/h3><p>Gunakan jarum suntik yang telah melalui proses sterilisasi dan persiapan penuh.<\/p><h3>2. Pengaturan<\/h3><ul><li>Lepaskan tutup ujung dengan hati-hati.<\/li><li>Kencangkan jarum suntik secara vertikal di antara penahan (flensa jari) dan pencengkeram (kerah LLA) tanpa menekan kerah.<\/li><\/ul><h3>3. Eksekusi Tes<\/h3><ul><li>Atur sel beban ke nol, pastikan tidak ada beban awal.<\/li><li>Terapkan gaya tarikan pada 20 mm\/menit.<\/li><li>Catat kurva gaya versus perpindahan secara terus-menerus.<\/li><\/ul><h3>4. Mengakhiri Tes<\/h3><p>Hentikan tes ketika kerah LLA terpisah dengan jelas dari jarum suntik.<\/p><h3>5. Pencatatan Hasil<\/h3><p>Puncak gaya maksimum pada kurva mewakili <em>gaya tarik<\/em>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc4abbc e-grid e-con-full e-con e-parent\" data-id=\"dc4abbc\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99d351b elementor-widget elementor-widget-image\" data-id=\"99d351b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ccc877e e-con-full e-flex e-con e-child\" data-id=\"ccc877e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef33af7 elementor-widget elementor-widget-heading\" data-id=\"ef33af7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mengapa Memilih <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b43d751 elementor-widget elementor-widget-text-editor\" data-id=\"b43d751\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"203\" data-end=\"463\">Di <strong>Syringetest.com<\/strong>kami menyatukan keahlian dan inovasi, mulai dari teknik yang tepat hingga layanan yang dipersonalisasi untuk mendukung pelanggan kami di seluruh dunia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28e0c7c elementor-widget elementor-widget-text-editor\" data-id=\"28e0c7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Melakukan proses <em>Gaya tarik kerah adaptor kunci Luer<\/em> uji menurut <em>ISO 11040-4 Lampiran G3<\/em> sangat penting untuk memastikan keamanan mekanis jarum suntik kunci Luer. Pelaksanaan dan dokumentasi yang tepat memberikan jaminan bahwa jarum suntik dapat bertahan dalam tekanan penggunaan klinis tanpa kegagalan.<br \/>Mengandalkan <strong>Syringetest.com<\/strong> untuk solusi pengujian mutakhir yang meningkatkan kualitas dan keamanan produk jarum suntik Anda.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5463cac elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"5463cac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/id\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Hubungi Kami<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Adaptor Collar Pull-Off Force In the pharmaceutical and medical device industries, ensuring the integrity of syringe components is critical. One essential quality check is the this test. This evaluation measures the strength of the connection between the Luer lock adaptor (LLA) collar and the syringe barrel, preventing component separation during use. The Importance [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-265","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages\/265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/comments?post=265"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages\/265\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/media?parent=265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}