{"id":247,"date":"2025-05-06T02:59:16","date_gmt":"2025-05-06T02:59:16","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=247"},"modified":"2026-05-14T08:15:29","modified_gmt":"2026-05-14T08:15:29","slug":"needle-tubing-stiffness-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/id\/needle-tubing-stiffness-test","title":{"rendered":"Uji Kekakuan Tabung Jarum"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"247\" class=\"elementor elementor-247\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1e601d7 e-flex e-con-boxed e-con e-parent\" data-id=\"1e601d7\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0e5a4e8 elementor-widget elementor-widget-heading\" data-id=\"0e5a4e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Uji Kekakuan Tabung Jarum<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-307f5d3 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"307f5d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong>uji kekakuan tabung jarum<\/strong> memainkan peran penting dalam memastikan kinerja dan keamanan perangkat medis, khususnya jarum hipodermik. Pengujian ini menentukan ketahanan tabung baja tahan karat terhadap pembengkokan ketika gaya standar diterapkan. Bagi para profesional di industri perangkat medis-terutama mereka yang terlibat dalam jaminan kualitas jarum suntik-memahami pengujian ini sangat penting untuk memenuhi standar peraturan dan memastikan keselamatan pasien.<\/p><p>Syringetest.com menawarkan solusi presisi tinggi untuk melakukan uji kekakuan tabung jarum, memastikan produk Anda memenuhi standar global seperti <strong>ISO 9626<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5684a6e e-flex e-con-boxed e-con e-parent\" data-id=\"5684a6e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-02d54a2 elementor-widget elementor-widget-heading\" data-id=\"02d54a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 9626 dan ISO 9626 Lampiran B<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b9bcb4 e-con-full e-flex e-con e-child\" data-id=\"1b9bcb4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c55fa1a elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"c55fa1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.syringetest.com\/id\/standards\/iso-9626\/\"><strong>ISO 9626<\/strong><\/a>, berjudul <em>Tabung jarum baja tahan karat untuk pembuatan perangkat medis - Persyaratan dan metode pengujian<\/em>menetapkan kriteria fisik dan mekanis untuk pipa baja tahan karat yang digunakan dalam perangkat medis. Di antara komponen utamanya, <strong>ISO 9626 Lampiran B<\/strong> menyediakan metode terperinci untuk melakukan <strong>uji kekakuan tabung jarum<\/strong>yang menawarkan persyaratan prosedural dan spesifikasi peralatan yang ketat.<\/p><p>Lampiran B menguraikan cara menilai kekakuan dengan menerapkan <strong>kekuatan yang ditentukan<\/strong> ke tengah tabung yang didukung di kedua ujungnya dan mengukur <strong>defleksi yang dihasilkan<\/strong>. Proses ini membantu mengevaluasi apakah pipa memenuhi kekuatan mekanis yang diperlukan untuk menahan penggunaan di dunia nyata tanpa bengkok atau gagal.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25a7788 elementor-widget elementor-widget-image\" data-id=\"25a7788\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"590\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard.webp\" class=\"attachment-large size-large wp-image-99\" alt=\"standar pengujian gaya lepas dan gaya luncur\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard-300x295.webp 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd39b91 e-con-full e-flex e-con e-child\" data-id=\"fd39b91\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-315872e elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"315872e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Prinsip dan Signifikansi Uji<\/h3><p>Prinsip inti dari <strong>uji kekakuan tabung jarum<\/strong> sangat mudah: gaya ke bawah yang tetap diterapkan ke bagian tengah tabung jarum, yang disangga secara horizontal di kedua ujungnya. The <strong>jumlah defleksi<\/strong> pada titik penerapan gaya menunjukkan kekakuan tabung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0b91159 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"0b91159\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Mengapa ini penting?<\/h3><ul><li><strong>Keamanan produk:<\/strong> Hindari pembengkokan atau kerusakan selama injeksi.<\/li><li><strong>Konsistensi produksi:<\/strong> Pastikan setiap batch memenuhi standar mekanis yang sama.<\/li><li><strong>Kepatuhan terhadap peraturan:<\/strong> Bertemu <strong>ISO 9626<\/strong> sertifikasi untuk memasuki pasar global.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2176b2b e-flex e-con-boxed e-con e-parent\" data-id=\"2176b2b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0601f88 elementor-widget elementor-widget-heading\" data-id=\"0601f88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Peralatan yang Diperlukan untuk Uji Kekakuan Tabung Jarum<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91dcc43 elementor-widget elementor-widget-text-editor\" data-id=\"91dcc43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Untuk melakukan pengujian sesuai dengan <strong>ISO 9626 Lampiran B<\/strong>diperlukan peralatan berikut ini:<\/p><h3>Alat Uji Kekakuan<\/h3><p class=\"\" data-start=\"2125\" data-end=\"2247\">Mampu menerapkan hingga <strong>60 N<\/strong> kekuatan dengan akurasi <strong>\u00b10.1 N<\/strong>, menampilkan <strong>pendorong berbentuk baji tumpul<\/strong>. Irisan harus terdiri dari dua permukaan datar yang dimiringkan pada <strong>60\u00b0<\/strong>berpotongan dengan permukaan silinder dengan a <strong>Radius 1 mm<\/strong>.<\/p><h3 data-start=\"2125\" data-end=\"2247\">Perangkat Pengukuran Defleksi<\/h3><p class=\"\" data-start=\"2755\" data-end=\"3082\">Akurat untuk <strong>0,01 mm<\/strong>digunakan untuk mencatat seberapa besar tekukan pipa di bawah gaya yang diberikan.<\/p><p>Syringetest.com menyediakan instrumen pengujian yang dapat disesuaikan yang sepenuhnya memenuhi persyaratan teknis ini, membantu laboratorium dan produsen menerapkan proses pengujian yang terstandardisasi dan dapat diulang.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-512b05c e-flex e-con-boxed e-con e-parent\" data-id=\"512b05c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-820f2d6 elementor-widget elementor-widget-heading\" data-id=\"820f2d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prosedur Uji Kekakuan Tabung Jarum<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9839f71 elementor-widget elementor-widget-text-editor\" data-id=\"9839f71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>1. Penempatan Sampel<\/h3><p>Tempatkan tabung pada alat pengujian. Pastikan:<\/p><ul><li>The <strong>rentang<\/strong> sesuai dengan nilai yang tercantum dalam ISO 9626 Tabel 2 untuk ukuran tabung yang diberikan.<\/li><li>The <strong>pendorong<\/strong> berada di tengah.<\/li><li>Tabung berorientasi <strong>tegak lurus<\/strong> ke titik pendorong dan titik penyangga.<\/li><\/ul><h3>2. Aplikasi Paksa<\/h3><p>Terapkan gaya ke bawah seperti yang ditentukan untuk ukuran tabung, dengan kecepatan yang terkendali <strong>1 mm\/menit hingga 10 mm\/menit<\/strong>.<\/p><h3>3. Pengukuran Lendutan<\/h3><p>Mengukur dan mencatat <strong>defleksi<\/strong> dari tabung di bagian tengah dengan akurasi <strong>\u00b1 0,01 mm<\/strong>.<\/p><h3>4. Hasil Pelaporan<\/h3><p>Laporan pengujian yang lengkap harus menyertakan:<\/p><ul><li>Ukuran dan identifikasi tabung<\/li><li>Jenis tabung (RW, TW, ETW, UTW)<\/li><li>Lendutan terukur<\/li><li>Tanggal pengujian<\/li><li>Paduan baja tahan karat yang digunakan<\/li><\/ul><p>Penguji kekakuan otomatis Syringetest.com menyederhanakan proses ini dengan mengintegrasikan <strong>sensor presisi<\/strong> dan <strong>antarmuka yang ramah pengguna<\/strong> untuk memastikan pengulangan dan ketertelusuran hasil pengujian.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b7a8cd e-grid e-con-full e-con e-parent\" data-id=\"7b7a8cd\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ce47441 elementor-widget elementor-widget-image\" data-id=\"ce47441\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-413684e e-con-full e-flex e-con e-child\" data-id=\"413684e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5ae9222 elementor-widget elementor-widget-heading\" data-id=\"5ae9222\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mengapa Memilih <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ee84ad elementor-widget elementor-widget-text-editor\" data-id=\"8ee84ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Sebagai penyedia solusi pengujian material yang tepercaya, <strong>Syringetest.com<\/strong> memberikan instrumen yang memenuhi dan melampaui standar ISO. Penguji kekakuan kami dirancang untuk:<\/p><ul><li><strong>Presisi dan keandalan yang tinggi<\/strong><\/li><li><strong>Kustomisasi pengguna<\/strong> untuk ukuran tabung khusus atau jenis paduan<\/li><li><strong>Opsi otomatisasi<\/strong> untuk meningkatkan efisiensi pengujian<\/li><li><strong>Pencatatan dan penelusuran data<\/strong> untuk kesiapan audit<\/li><\/ul><p>Kami melayani industri mulai dari <strong>alat kesehatan dan farmasi hingga laboratorium kendali mutu<\/strong>. Dengan fokus yang kuat pada inovasi, kami juga mendukung <strong>peningkatan otomatisasi<\/strong> dan <strong>pengembangan tes khusus<\/strong>.<\/p><p>The <strong>uji kekakuan tabung jarum<\/strong>bila dilakukan dengan benar di bawah <strong>ISO 9626 Lampiran B<\/strong>memastikan bahwa tabung medis mempertahankan integritas mekanis selama penggunaan. Ini bukan hanya tentang kepatuhan-ini tentang <strong>melindungi pasien dan menjaga kepercayaan<\/strong> dalam produk medis.<\/p><p>Dengan instrumen pengujian kelas profesional dari <strong>Syringetest.com<\/strong>produsen dapat dengan yakin memastikan kualitas produk, memenuhi standar internasional, dan merampingkan proses kontrol kualitas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-383dde0 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"383dde0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/id\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Hubungi Kami<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Needle Tubing Stiffness Test The needle tubing stiffness test plays a critical role in ensuring the performance and safety of medical devices, particularly hypodermic needles. This test determines the resistance of stainless steel tubing to bending when a standardized force is applied. For professionals in the medical device industry\u2014especially those involved in quality assurance of [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-247","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages\/247","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/comments?post=247"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/pages\/247\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/id\/wp-json\/wp\/v2\/media?parent=247"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}