{"id":734,"date":"2026-01-15T00:43:19","date_gmt":"2026-01-15T00:43:19","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=734"},"modified":"2026-05-19T06:56:55","modified_gmt":"2026-05-19T06:56:55","slug":"iso-7864","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/fr\/standards\/iso-7864","title":{"rendered":"ISO 7864"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"734\" class=\"elementor elementor-734\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d73e1f9 e-flex e-con-boxed e-con e-parent\" data-id=\"d73e1f9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9edf82d elementor-widget elementor-widget-heading\" data-id=\"9edf82d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Essai de rigidit\u00e9 des tubes \u00e0 aiguilles<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a4efb8b elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"a4efb8b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le <strong>essai de rigidit\u00e9 d'un tube d'aiguille<\/strong> joue un r\u00f4le essentiel pour garantir la performance et la s\u00e9curit\u00e9 des dispositifs m\u00e9dicaux, en particulier des aiguilles hypodermiques. Ce test d\u00e9termine la r\u00e9sistance des tubes en acier inoxydable \u00e0 la flexion lorsqu'une force normalis\u00e9e est appliqu\u00e9e. Pour les professionnels de l'industrie des dispositifs m\u00e9dicaux, en particulier ceux qui participent \u00e0 l'assurance qualit\u00e9 des seringues, la compr\u00e9hension de ce test est essentielle pour r\u00e9pondre aux normes r\u00e9glementaires et garantir la s\u00e9curit\u00e9 des patients.<\/p><p>Syringetest.com propose des solutions de haute pr\u00e9cision pour r\u00e9aliser des tests de rigidit\u00e9 des tubes d'aiguilles, garantissant ainsi la conformit\u00e9 de vos produits aux normes internationales telles que <strong>ISO 9626<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b81623f e-flex e-con-boxed e-con e-parent\" data-id=\"b81623f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-563f650 elementor-widget elementor-widget-heading\" data-id=\"563f650\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 7864 et le contr\u00f4le de la qualit\u00e9 des aiguilles hypodermiques<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-410aa6c elementor-widget elementor-widget-text-editor\" data-id=\"410aa6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"463\" data-end=\"847\"><strong data-start=\"463\" data-end=\"475\">ISO 7864<\/strong> est la principale norme internationale r\u00e9gissant les aiguilles hypodermiques st\u00e9riles \u00e0 usage unique. Elle d\u00e9finit \u00e0 la fois des exigences de performance et des m\u00e9thodes d'essai v\u00e9rifi\u00e9es pour garantir la s\u00e9curit\u00e9, la coh\u00e9rence et la fonctionnalit\u00e9 de l'utilisation clinique. Du point de vue de la qualit\u00e9 et de la r\u00e9glementation, la norme ISO 7864 \u00e9tablit un lien entre la conception du produit, la s\u00e9lection des mat\u00e9riaux et les performances m\u00e9caniques par le biais d'essais objectifs.<\/p><p data-start=\"849\" data-end=\"1181\">Pour les fabricants, les laboratoires de dispositifs m\u00e9dicaux et les agences d'inspection, l'ISO 7864 fournit un cadre structur\u00e9 pour \u00e9valuer la r\u00e9sistance de l'aiguille, le comportement de p\u00e9n\u00e9tration, la fiabilit\u00e9 du collage et la performance de l'administration des fluides. Ces param\u00e8tres affectent directement la s\u00e9curit\u00e9 de l'utilisateur, le confort du patient et la conformit\u00e9 aux attentes r\u00e9glementaires mondiales.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ab1bcd9 e-flex e-con-boxed e-con e-parent\" data-id=\"ab1bcd9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6501021 elementor-widget elementor-widget-heading\" data-id=\"6501021\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test des aiguilles hypodermiques selon la norme ISO 7864<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bdb7ead elementor-widget elementor-widget-text-editor\" data-id=\"bdb7ead\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Tests sur les aiguilles hypodermiques Champ d'application et importance<\/h3><p data-start=\"1287\" data-end=\"1679\">A l'int\u00e9rieur <strong data-start=\"1294\" data-end=\"1323\">test des aiguilles hypodermiques<\/strong>, La norme ISO 7864 met l'accent sur l'int\u00e9grit\u00e9 m\u00e9canique et les performances fonctionnelles. La norme traite de la mani\u00e8re dont une aiguille p\u00e9n\u00e8tre les substrats de type tissulaire, de la solidit\u00e9 de sa liaison \u00e0 l'embase et de l'efficacit\u00e9 avec laquelle elle d\u00e9livre des fluides. Chaque test cible un risque sp\u00e9cifique li\u00e9 \u00e0 l'utilisation de l'aiguille, comme la douleur excessive \u00e0 l'insertion, le d\u00e9tachement de l'embase ou la restriction du d\u00e9bit.<\/p><p data-start=\"1681\" data-end=\"1877\">Les essais conformes \u00e0 la norme ISO 7864 garantissent que les aiguilles hypodermiques fonctionnent de mani\u00e8re coh\u00e9rente d'un lot \u00e0 l'autre et d'un site de fabrication \u00e0 l'autre, ce qui est particuli\u00e8rement important pour les dispositifs m\u00e9dicaux jetables en grande quantit\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-49e84ed e-flex e-con-boxed e-con e-parent\" data-id=\"49e84ed\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fadb478 elementor-widget elementor-widget-heading\" data-id=\"fadb478\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test de p\u00e9n\u00e9tration de l'aiguille et \u00e9valuation de la force de p\u00e9n\u00e9tration<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a4d18ab e-con-full e-flex e-con e-child\" data-id=\"a4d18ab\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c3ef343 elementor-widget elementor-widget-text-editor\" data-id=\"c3ef343\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1945\" data-end=\"2214\">L'une des proc\u00e9dures les plus critiques d\u00e9crites dans la norme ISO 7864 est la suivante <strong data-start=\"2010\" data-end=\"2037\">test de p\u00e9n\u00e9tration \u00e0 l'aiguille<\/strong>. Cette m\u00e9thode mesure la force n\u00e9cessaire pour qu'une aiguille p\u00e9n\u00e8tre dans un substrat normalis\u00e9 \u00e0 une vitesse constante. La courbe force-d\u00e9placement qui en r\u00e9sulte fournit deux indicateurs cl\u00e9s :<\/p><ul data-start=\"2216\" data-end=\"2390\"><li data-start=\"2216\" data-end=\"2304\"><p data-start=\"2218\" data-end=\"2304\"><strong data-start=\"2218\" data-end=\"2244\">Force de p\u00e9n\u00e9tration maximale<\/strong>, repr\u00e9sentant la r\u00e9sistance maximale lors de l'entr\u00e9e initiale<\/p><\/li><li data-start=\"2305\" data-end=\"2390\"><p data-start=\"2307\" data-end=\"2390\"><strong data-start=\"2307\" data-end=\"2321\">Force de tra\u00een\u00e9e<\/strong>, refl\u00e9tant le frottement lorsque l'aiguille traverse le substrat<\/p><\/li><\/ul><p data-start=\"2392\" data-end=\"2679\">Mesure contr\u00f4l\u00e9e des <strong data-start=\"2418\" data-end=\"2439\">force de p\u00e9n\u00e9tration<\/strong> aide les fabricants \u00e0 optimiser la g\u00e9om\u00e9trie de l'aiguille, le tranchant de la pointe et la finition de la surface. Une force de p\u00e9n\u00e9tration excessive peut accro\u00eetre l'inconfort du patient, tandis qu'une force insuffisamment constante peut indiquer une variabilit\u00e9 dans les processus de meulage ou de polissage.<\/p><p data-start=\"2681\" data-end=\"2949\">Un service d\u00e9di\u00e9 <strong data-start=\"2693\" data-end=\"2712\">Testeur de force<\/strong> \u00e9quip\u00e9 d'une cellule de charge \u00e0 haute r\u00e9solution garantit une mesure fiable de la force et des r\u00e9sultats reproductibles. Les syst\u00e8mes modernes permettent un contr\u00f4le pr\u00e9cis de la vitesse et un enregistrement continu de la force, ce qui favorise \u00e0 la fois le d\u00e9veloppement et le contr\u00f4le de qualit\u00e9 de routine.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b56513 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"7b56513\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"284\" height=\"457\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-7864-Annex-D.png\" class=\"attachment-large size-large wp-image-736\" alt=\"ISO 7864 Annexe D\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-7864-Annex-D.png 284w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-7864-Annex-D-186x300.png 186w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-7864-Annex-D-7x12.png 7w\" sizes=\"(max-width: 284px) 100vw, 284px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b74a0d4 elementor-widget elementor-widget-text-editor\" data-id=\"b74a0d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 data-start=\"2999\" data-end=\"3310\">Test de fragmentation des aiguilles m\u00e9dicales<\/h3><p data-start=\"2999\" data-end=\"3310\">Le <strong data-start=\"3003\" data-end=\"3045\">test de fragmentation des aiguilles m\u00e9dicales<\/strong> se concentre sur la s\u00e9curit\u00e9 structurelle. Lors de l'insertion et du retrait, une aiguille doit rester intacte sans perdre de fragments qui pourraient rester dans les tissus. La norme ISO 7864 comprend des exigences permettant de v\u00e9rifier que l'aiguille conserve son int\u00e9grit\u00e9 dans des conditions m\u00e9caniques d\u00e9finies.<\/p><p data-start=\"3312\" data-end=\"3584\">Ce test permet de r\u00e9duire les risques lors de l'utilisation clinique et confirme que la qualit\u00e9 des mat\u00e9riaux, le traitement thermique et les processus de fabrication respectent le seuil de s\u00e9curit\u00e9 pr\u00e9vu. Les r\u00e9sultats de la fragmentation fournissent \u00e9galement des informations pr\u00e9cieuses lors de la qualification des fournisseurs et de la validation des processus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5fec398 e-con-full e-flex e-con e-child\" data-id=\"5fec398\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fe421e2 elementor-widget elementor-widget-text-editor\" data-id=\"fe421e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 data-start=\"3641\" data-end=\"3862\">V\u00e9rification de l'adh\u00e9rence de l'aiguille et de la force d'adh\u00e9rence<\/h3><p data-start=\"3641\" data-end=\"3862\"><strong data-start=\"3641\" data-end=\"3656\">Collage \u00e0 l'aiguille<\/strong> repr\u00e9sente la liaison m\u00e9canique entre le tube de l'aiguille et le moyeu. La norme ISO 7864 sp\u00e9cifie une m\u00e9thode d'essai de traction pour confirmer que cette liaison r\u00e9siste \u00e0 des charges d\u00e9finies sans s\u00e9paration ni d\u00e9faillance.<\/p><p data-start=\"3864\" data-end=\"4178\">\u00c0 l'aide d'un appareil de traction calibr\u00e9 <strong data-start=\"3891\" data-end=\"3910\">Testeur de force<\/strong>, L'aiguille est tir\u00e9e axialement \u00e0 une vitesse contr\u00f4l\u00e9e jusqu'\u00e0 ce qu'une s\u00e9paration se produise ou qu'une force maximale soit atteinte. La valeur enregistr\u00e9e refl\u00e8te la force de collage et indique si l'adh\u00e9sif ou le processus de collage s\u00e9lectionn\u00e9 est adapt\u00e9 \u00e0 la taille de l'aiguille et \u00e0 l'application.<\/p><p data-start=\"4180\" data-end=\"4324\">La fiabilit\u00e9 de la liaison de l'aiguille est essentielle pour \u00e9viter un d\u00e9tachement accidentel pendant l'injection, ce qui pourrait entra\u00eener de graves incidents de s\u00e9curit\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a4a6c9 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"5a4a6c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-7864-Standard-Guide-for-Hypodermic-Needle-Testing.webp\" class=\"attachment-large size-large wp-image-737\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-7864-Standard-Guide-for-Hypodermic-Needle-Testing.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-7864-Standard-Guide-for-Hypodermic-Needle-Testing-300x300.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-7864-Standard-Guide-for-Hypodermic-Needle-Testing-150x150.webp 150w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/01\/ISO-7864-Standard-Guide-for-Hypodermic-Needle-Testing-12x12.webp 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e5b9339 e-flex e-con-boxed e-con e-parent\" data-id=\"e5b9339\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5ab1bb9 elementor-widget elementor-widget-heading\" data-id=\"5ab1bb9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">S\u00e9lection de l'\u00e9quipement de test de seringues appropri\u00e9<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3881c58 e-grid e-con-full e-con e-child\" data-id=\"3881c58\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-10aa2f8 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"10aa2f8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img decoding=\"async\" width=\"1698\" height=\"2560\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp\" class=\"attachment-full size-full wp-image-884\" alt=\"SLT-02 Test d&#039;\u00e9tanch\u00e9it\u00e9 de seringue\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp 1698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-199x300.webp 199w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-679x1024.webp 679w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-768x1158.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1019x1536.webp 1019w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1358x2048.webp 1358w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-8x12.webp 8w\" sizes=\"(max-width: 1698px) 100vw, 1698px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">SLT-02 Testeur d'\u00e9tanch\u00e9it\u00e9 de seringue<\/h3><p class=\"elementor-image-box-description\">Cet instrument applique avec pr\u00e9cision un vide contr\u00f4l\u00e9 \u00e0 la seringue, ce qui permet un contr\u00f4le pr\u00e9cis des variations de pression et de l'int\u00e9grit\u00e9 du piston. Con\u00e7u avec des connexions compatibles avec la norme ISO 80369-7 et des m\u00e9canismes de serrage s\u00fbrs, le SLT-01 garantit une \u00e9valuation compl\u00e8te de l'\u00e9tanch\u00e9it\u00e9 \u00e0 l'air et de la r\u00e9tention du bouchon du piston.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-361ebe4 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"361ebe4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img decoding=\"async\" width=\"1698\" height=\"2560\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp\" class=\"attachment-full size-full wp-image-884\" alt=\"SLT-02 Test d&#039;\u00e9tanch\u00e9it\u00e9 de seringue\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp 1698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-199x300.webp 199w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-679x1024.webp 679w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-768x1158.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1019x1536.webp 1019w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1358x2048.webp 1358w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-8x12.webp 8w\" sizes=\"(max-width: 1698px) 100vw, 1698px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">MST-01 Testeur de seringues m\u00e9dicales<\/h3><p class=\"elementor-image-box-description\">Il utilise un syst\u00e8me m\u00e9canique de haute pr\u00e9cision pour mesurer les forces de d\u00e9collement et de glissement pendant l'expulsion du liquide. Le MST-01 permet aux fabricants de quantifier la r\u00e9sistance \u00e0 l'amor\u00e7age et au d\u00e9placement, fournissant ainsi des donn\u00e9es essentielles pour garantir un mouvement fluide et constant du piston, indispensable pour assurer la s\u00e9curit\u00e9 et le confort.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3941d7a elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"3941d7a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img decoding=\"async\" width=\"1698\" height=\"2560\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp\" class=\"attachment-full size-full wp-image-884\" alt=\"SLT-02 Test d&#039;\u00e9tanch\u00e9it\u00e9 de seringue\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp 1698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-199x300.webp 199w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-679x1024.webp 679w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-768x1158.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1019x1536.webp 1019w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1358x2048.webp 1358w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-8x12.webp 8w\" sizes=\"(max-width: 1698px) 100vw, 1698px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">SPPT-01 Testeur d'\u00e9tanch\u00e9it\u00e9 de seringue<\/h3><p class=\"elementor-image-box-description\">Ce dispositif simule la pression \u00e0 l'int\u00e9rieur du corps de la seringue tout en appliquant des charges lat\u00e9rales et axiales au piston, reproduisant fid\u00e8lement les conditions d'utilisation clinique. Le SSPT-01 est con\u00e7u pour d\u00e9tecter les d\u00e9faillances de joints les plus subtiles, aidant ainsi les fabricants \u00e0 v\u00e9rifier la fiabilit\u00e9 de leurs produits et leur conformit\u00e9 aux normes de s\u00e9curit\u00e9 les plus strictes.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c968107 e-flex e-con-boxed e-con e-parent\" data-id=\"c968107\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b8d92db elementor-widget elementor-widget-heading\" data-id=\"b8d92db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9bit \u00e0 travers le test de l'aiguille<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dbf4622 elementor-widget elementor-widget-text-editor\" data-id=\"dbf4622\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4369\" data-end=\"4614\">Outre la r\u00e9sistance m\u00e9canique, la norme ISO 7864 aborde la performance fonctionnelle par le biais des \u00e9l\u00e9ments suivants <strong data-start=\"4459\" data-end=\"4496\">d\u00e9bit \u00e0 travers le test de l'aiguille<\/strong>. Cette \u00e9valuation confirme que la lumi\u00e8re interne permet aux fluides de passer \u00e0 une vitesse attendue dans des conditions d\u00e9finies.<\/p><p data-start=\"4616\" data-end=\"4869\">Les r\u00e9sultats du d\u00e9bit sont \u00e9troitement li\u00e9s \u00e0 la consistance du diam\u00e8tre int\u00e9rieur, \u00e0 la finition de la surface et \u00e0 la propret\u00e9. Un d\u00e9bit stable et pr\u00e9visible garantit un dosage pr\u00e9cis et une injection en douceur, en particulier dans les applications impliquant des formulations pharmaceutiques visqueuses.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-07a4672 e-grid e-con-full e-con e-parent\" data-id=\"07a4672\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fdb4b8e elementor-widget elementor-widget-image\" data-id=\"fdb4b8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c92dd9a e-con-full e-flex e-con e-child\" data-id=\"c92dd9a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3ee07a1 elementor-widget elementor-widget-heading\" data-id=\"3ee07a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Avantages des \u00e9quipements d'essai et de l'automatisation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ad2b6d9 elementor-widget elementor-widget-text-editor\" data-id=\"ad2b6d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4921\" data-end=\"5328\">Pour r\u00e9pondre efficacement \u00e0 la norme ISO 7864, les laboratoires s'appuient de plus en plus sur des plates-formes d'essai int\u00e9gr\u00e9es. Une plate-forme<a href=\"https:\/\/www.qualitester.com\/product\/medical-needle-puncture-tester\/\" target=\"_blank\" rel=\"noopener\"> <strong data-start=\"5024\" data-end=\"5068\">Test de p\u00e9n\u00e9tration d'aiguille et de force de tra\u00een\u00e9e<\/strong><\/a> de <strong data-start=\"5074\" data-end=\"5094\">Instruments cellulaires<\/strong> combine la mesure de la force de p\u00e9n\u00e9tration, l'analyse de la force de tra\u00een\u00e9e et la conception d'un dispositif flexible en un seul syst\u00e8me. Ces solutions permettent de r\u00e9aliser des essais normalis\u00e9s tout en autorisant la personnalisation pour des types d'aiguilles sp\u00e9cifiques ou pour r\u00e9pondre aux exigences des clients.<\/p><p data-start=\"5330\" data-end=\"5548\">Les options d'automatisation am\u00e9liorent encore la r\u00e9p\u00e9tabilit\u00e9, r\u00e9duisent l'influence de l'op\u00e9rateur et favorisent les environnements d'essai \u00e0 haut d\u00e9bit. Ces avantages sont conformes aux objectifs de la norme ISO 7864 et aux syst\u00e8mes modernes de gestion de la qualit\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4a5ac7c elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"4a5ac7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/fr\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Nous contacter<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-88a448a e-flex e-con-boxed e-con e-parent\" data-id=\"88a448a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e2733d elementor-widget elementor-widget-text-editor\" data-id=\"6e2733d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"5570\" data-end=\"5981\"><strong data-start=\"5570\" data-end=\"5582\">ISO 7864<\/strong> \u00e9tablit une base technique compl\u00e8te pour l'\u00e9valuation des aiguilles hypodermiques st\u00e9riles. Gr\u00e2ce \u00e0 des tests structur\u00e9s sur les aiguilles hypodermiques, y compris les proc\u00e9dures de test de p\u00e9n\u00e9tration de l'aiguille, l'analyse de la force de p\u00e9n\u00e9tration, la v\u00e9rification de la force d'adh\u00e9rence de l'aiguille, le test de fragmentation des aiguilles m\u00e9dicales et le test de d\u00e9bit \u00e0 travers l'aiguille, les fabricants peuvent garantir la s\u00e9curit\u00e9, la performance et la conformit\u00e9 aux r\u00e9glementations.<\/p><p data-start=\"5983\" data-end=\"6242\" data-is-last-node=\"\" data-is-only-node=\"\">En adoptant des solutions de test avanc\u00e9es telles que le <a href=\"https:\/\/www.qualitester.com\/\" target=\"_blank\" rel=\"noopener\">Instruments cellulaires<\/a> Needle Penetration and Drag Force Tester, les entreprises peuvent am\u00e9liorer la fiabilit\u00e9 des donn\u00e9es, rationaliser le contr\u00f4le de la qualit\u00e9 et r\u00e9pondre en toute confiance aux exigences de la norme ISO 7864 tout au long du cycle de vie du produit.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Needle Tubing Stiffness Test The needle tubing stiffness test plays a critical role in ensuring the performance and safety of medical devices, particularly hypodermic needles. This test determines the resistance of stainless steel tubing to bending when a standardized force is applied. For professionals in the medical device industry\u2014especially those involved in quality assurance of [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":603,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-734","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/pages\/734","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/comments?post=734"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/pages\/734\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/pages\/603"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/media?parent=734"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}