{"id":288,"date":"2025-05-06T06:58:13","date_gmt":"2025-05-06T06:58:13","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=288"},"modified":"2025-05-06T06:59:48","modified_gmt":"2025-05-06T06:59:48","slug":"luer-lock-rigid-tip-cap-unscrewing-torque","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/fr\/luer-lock-rigid-tip-cap-unscrewing-torque","title":{"rendered":"Couple de d\u00e9vissage du bouchon Luer Lock \u00e0 embout rigide"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"288\" class=\"elementor elementor-288\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-292be0b e-flex e-con-boxed e-con e-parent\" data-id=\"292be0b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0f48abd elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"0f48abd\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Couple de d\u00e9vissage du bouchon Luer Lock \u00e0 embout rigide<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6817f29 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"6817f29\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dans le domaine de la fabrication de dispositifs m\u00e9dicaux, la <strong>couple de d\u00e9vissage de l'embout rigide luer lock<\/strong> joue un r\u00f4le essentiel dans la v\u00e9rification de la facilit\u00e9 d'utilisation et de la s\u00e9curit\u00e9 des seringues pr\u00e9remplies. Ce test critique permet de s'assurer que l'embout rigide peut \u00eatre retir\u00e9 avec un couple appropri\u00e9, ce qui garantit \u00e0 la fois la fonctionnalit\u00e9 et la s\u00e9curit\u00e9 du patient. Des tests pr\u00e9cis sont essentiels pour se conformer aux normes internationales et pour maintenir les normes de production de haute qualit\u00e9 attendues dans l'industrie m\u00e9dicale.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b18db3 e-flex e-con-boxed e-con e-parent\" data-id=\"7b18db3\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ecf369e elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ecf369e\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Importance du test du bouchon Luer Lock \u00e0 pointe rigide<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f390758 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"f390758\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L'ex\u00e9cution correcte de ce test garantit :<\/p><ul><li><strong>S\u00e9curit\u00e9 des patients<\/strong>: En veillant \u00e0 ce que les bouchons ne soient ni trop serr\u00e9s ni trop l\u00e2ches, on prot\u00e8ge les patients contre la contamination ou les probl\u00e8mes d'utilisation.<\/li><li><strong>Conformit\u00e9 r\u00e9glementaire<\/strong>: Le respect des normes ISO 11040-4 est essentiel pour l'acc\u00e8s au march\u00e9 et l'acceptation des produits.<\/li><li><strong>Coh\u00e9rence des produits<\/strong>: Les essais favorisent la coh\u00e9rence des processus de fabrication, r\u00e9duisent les d\u00e9fauts et garantissent la fiabilit\u00e9 des lots.<\/li><\/ul><p>L'expertise de Syringetest.com en mati\u00e8re d'essais de mat\u00e9riaux et de solutions personnalis\u00e9es permet aux fabricants de seringues de r\u00e9pondre efficacement \u00e0 ces exigences rigoureuses en mati\u00e8re d'essais, ce qui am\u00e9liore la qualit\u00e9 des produits et la comp\u00e9titivit\u00e9 du march\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4835ce e-flex e-con-boxed e-con e-parent\" data-id=\"d4835ce\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c400551 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"c400551\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 et ISO 11040-4 Annexe G5 Exigences<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-55047da e-con-full e-flex e-con e-child\" data-id=\"55047da\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f93495e elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"f93495e\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInLeft&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.syringetest.com\/fr\/standards\/iso-11040-4\/\">ISO 11040-4<\/a> et son annexe G5 d\u00e9crivent les proc\u00e9dures d\u00e9taill\u00e9es et les exigences en mati\u00e8re d'appareils pour l'\u00e9valuation de la <strong>couple de d\u00e9vissage de l'embout rigide luer lock<\/strong>. Ces lignes directrices garantissent des essais coh\u00e9rents et fiables dans l'ensemble du secteur.<\/p><p>Selon le <strong>ISO 11040-4 Annexe G5<\/strong>Le but de ce test est d'\u00e9valuer le couple n\u00e9cessaire pour d\u00e9visser le capuchon de l'embout rigide des seringues st\u00e9rilis\u00e9es et pr\u00eates \u00e0 \u00eatre remplies. L'objectif est de v\u00e9rifier si le couple de d\u00e9vissage du capuchon se situe dans des limites acceptables, ni trop \u00e9lev\u00e9es (ce qui pourrait nuire \u00e0 la facilit\u00e9 d'utilisation), ni trop faibles (ce qui pourrait compromettre la st\u00e9rilit\u00e9).<\/p><p>L'annexe pr\u00e9cise la n\u00e9cessit\u00e9 de :<\/p><ul><li>A <strong>testeur de couple<\/strong> \u00e9quip\u00e9 d'un dispositif de rotation.<\/li><li>A <strong>cellule de couple<\/strong> d'une capacit\u00e9 de 35 Ncm et d'une r\u00e9solution de 0,05 Ncm ou mieux.<\/li><li>A <strong>vitesse de rotation<\/strong> de 20 rotations par minute (rpm), r\u00e9glable sur la base d'un accord entre le fabricant et le client.<\/li><li>Les appareils sp\u00e9cialis\u00e9s tels que les <strong>pince pour capuchon d'embout<\/strong> et <strong>porte-seringue<\/strong>.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a601c24 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-image\" data-id=\"a601c24\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInRight&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"320\" height=\"410\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp\" class=\"attachment-full size-full wp-image-290\" alt=\"Force d&#039;arrachement de l&#039;embout ou du prot\u00e8ge-aiguille - ISO 11040-4 Annexe G5\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp 320w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5-234x300.webp 234w\" sizes=\"(max-width: 320px) 100vw, 320px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d2599ee e-flex e-con-boxed e-con e-parent\" data-id=\"d2599ee\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3919490 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"3919490\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Proc\u00e9dure d'essai pour le couple de d\u00e9vissage du capuchon \u00e0 pointe rigide Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-52ed66d elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"52ed66d\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ex\u00e9cution de la <strong>couple de d\u00e9vissage de l'embout rigide luer lock<\/strong> comporte plusieurs \u00e9tapes pr\u00e9cises :<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3792486 e-n-tabs-mobile elementor-invisible elementor-widget elementor-widget-n-tabs\" data-id=\"3792486\" data-element_type=\"widget\" data-settings=\"{&quot;tabs_justify_horizontal&quot;:&quot;center&quot;,&quot;_animation&quot;:&quot;fadeInUp&quot;,&quot;horizontal_scroll&quot;:&quot;disable&quot;}\" data-widget_type=\"nested-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-tabs\" data-widget-number=\"58270854\" aria-label=\"Tabs. Open items with Enter or Space, close with Escape and navigate using the Arrow keys.\" data-no-translation-aria-label=\"\">\n\t\t\t<div class=\"e-n-tabs-heading\" role=\"tablist\">\n\t\t\t\t\t<button id=\"e-n-tab-title-582708541\" class=\"e-n-tab-title\" aria-selected=\"true\" data-tab-index=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"e-n-tab-content-582708541\" style=\"--n-tabs-title-order: 1;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tPr\u00e9paration de l'\u00e9chantillon\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-582708542\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-582708542\" style=\"--n-tabs-title-order: 2;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tConfiguration de l'appareil\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-582708543\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-582708543\" style=\"--n-tabs-title-order: 3;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tProc\u00e9dure de test\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-582708544\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-582708544\" style=\"--n-tabs-title-order: 4;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tExpression des r\u00e9sultats\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t\t<\/div>\n\t\t\t<div class=\"e-n-tabs-content\">\n\t\t\t\t<div id=\"e-n-tab-content-582708541\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-582708541\" data-tab-index=\"1\" style=\"--n-tabs-title-order: 1;\" class=\"e-active elementor-element elementor-element-a7b6f7f e-con-full e-flex e-con e-child\" data-id=\"a7b6f7f\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e02b36e elementor-widget elementor-widget-text-editor\" data-id=\"e02b36e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>S\u00e9lectionnez des seringues sous-assembl\u00e9es st\u00e9rilis\u00e9es qui correspondent au processus de production. Une manipulation correcte des \u00e9chantillons garantit que les r\u00e9sultats repr\u00e9sentent fid\u00e8lement la qualit\u00e9 de la production.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-582708542\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-582708542\" data-tab-index=\"2\" style=\"--n-tabs-title-order: 2;\" class=\"elementor-element elementor-element-74537e6 e-con-full e-flex e-con e-child\" data-id=\"74537e6\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-171d590 elementor-widget elementor-widget-text-editor\" data-id=\"171d590\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Fixer la seringue verticalement dans le <strong>porte-seringue<\/strong> du dispositif d'essai.<\/li><li>Attachez le <strong>adaptateur<\/strong> (pince pour embout) sur l'embout en toute s\u00e9curit\u00e9 sans appliquer de pr\u00e9-couple.<\/li><li>R\u00e9glez la cellule de mesure du couple sur \"z\u00e9ro\" pour garantir la pr\u00e9cision de la ligne de base.<\/li><li>R\u00e9gler le dispositif de rotation \u00e0 20 tr\/min ou \u00e0 la vitesse convenue.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-582708543\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-582708543\" data-tab-index=\"3\" style=\"--n-tabs-title-order: 3;\" class=\"elementor-element elementor-element-71780a2 e-flex e-con-boxed e-con e-child\" data-id=\"71780a2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e8c3a51 elementor-widget elementor-widget-text-editor\" data-id=\"e8c3a51\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Initier la rotation dans le sens des aiguilles d'une montre ou dans le sens inverse des aiguilles d'une montre, selon les besoins du syst\u00e8me.<\/li><li>Maintenir une rotation constante jusqu'\u00e0 ce que l'embout commence \u00e0 se d\u00e9visser.<\/li><li>Enregistrer les <strong>couple de pointe<\/strong> appliqu\u00e9e au moment o\u00f9 le bouchon commence \u00e0 bouger.<\/li><\/ul><p>Il est essentiel d'assurer une <strong>taux d'\u00e9chantillonnage \u00e9lev\u00e9<\/strong> pendant les essais. L'annexe G5 recommande un taux d'\u00e9chantillonnage de 500 Hz pour les essais qui n\u00e9cessitent des mesures de couple de pointe, ce qui am\u00e9liore la pr\u00e9cision des donn\u00e9es.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-582708544\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-582708544\" data-tab-index=\"4\" style=\"--n-tabs-title-order: 4;\" class=\"elementor-element elementor-element-2995989 e-flex e-con-boxed e-con e-child\" data-id=\"2995989\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dde996a elementor-widget elementor-widget-text-editor\" data-id=\"dde996a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Apr\u00e8s avoir effectu\u00e9 le test, documentez les \u00e9l\u00e9ments suivants :<\/p><ul><li>Couple maximal atteint (en Ncm).<\/li><li>Vitesse de rotation utilis\u00e9e lors des essais.<\/li><li>Nombre d'\u00e9chantillons test\u00e9s et nombre d'\u00e9chantillons conformes ou non aux sp\u00e9cifications.<\/li><li>Tous les \u00e9carts, anomalies ou observations constat\u00e9s au cours des essais.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b581cc e-con-full e-flex e-con e-parent\" data-id=\"1b581cc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-61afd37 e-grid e-con-full e-con e-child\" data-id=\"61afd37\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-f8ace73 e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"f8ace73\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94cc5ad e-flex e-con-boxed elementor-invisible e-con e-child\" data-id=\"94cc5ad\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInRight&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-907b713 elementor-widget elementor-widget-heading\" data-id=\"907b713\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pourquoi choisir <b>Syringetest.com ?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-718f32f elementor-widget elementor-widget-text-editor\" data-id=\"718f32f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le <strong>couple de d\u00e9vissage de l'embout rigide luer lock<\/strong> tel que d\u00e9fini par <strong>ISO 11040-4 Annexe G5<\/strong>Le test d'utilisation est essentiel pour maintenir la qualit\u00e9 des seringues et garantir la conformit\u00e9 avec les normes mondiales. Avec le bon \u00e9quipement et les bonnes proc\u00e9dures de test, les fabricants peuvent valider en toute confiance la facilit\u00e9 d'utilisation de leurs seringues. Faites confiance \u00e0 Syringetest.com pour vous fournir des solutions de test de pr\u00e9cision adapt\u00e9es \u00e0 vos besoins, vous aidant \u00e0 respecter les normes les plus strictes en mati\u00e8re de s\u00e9curit\u00e9 et de qualit\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f735b94 elementor-widget elementor-widget-eael-creative-button\" data-id=\"f735b94\" data-element_type=\"widget\" data-widget_type=\"eael-creative-button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-creative-button-wrapper\">\n\n            <a class=\"eael-creative-button eael-creative-button--default\" href=\"#\" data-text=\"Contact Us\">\n\n\t    \n                <div class=\"creative-button-inner\">\n\n                    \n                    <span class=\"cretive-button-text\">Nous contacter<\/span>\n\n                                    <\/div>\n\t                        <\/a>\n        <\/div>\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Couple de d\u00e9vissage de l'embout rigide Luer Lock Dans le domaine de la fabrication de dispositifs m\u00e9dicaux, le test de couple de d\u00e9vissage de l'embout rigide Luer Lock joue un r\u00f4le essentiel dans la v\u00e9rification de la facilit\u00e9 d'utilisation et de la s\u00e9curit\u00e9 des seringues pr\u00e9-remplies. Ce test critique garantit que l'embout rigide peut \u00eatre retir\u00e9 avec un couple appropri\u00e9, pr\u00e9servant ainsi la fonctionnalit\u00e9 et la [...]<\/p>","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-288","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Luer Lock Rigid Tip Cap Unscrewing Torque - ISO 11040-4 Annex G5<\/title>\n<meta name=\"description\" content=\"Perform the luer lock rigid tip cap unscrewing torque test following ISO 11040-4 and Annex G5 to ensure syringe quality and compliance.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.syringetest.com\/fr\/luer-lock-rigid-tip-cap-unscrewing-torque\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Luer Lock Rigid Tip Cap Unscrewing Torque - ISO 11040-4 Annex G5\" \/>\n<meta property=\"og:description\" content=\"Perform the luer lock rigid tip cap unscrewing torque test following ISO 11040-4 and Annex G5 to ensure syringe quality and compliance.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.syringetest.com\/fr\/luer-lock-rigid-tip-cap-unscrewing-torque\/\" \/>\n<meta property=\"og:site_name\" content=\"Syringe and Needle Testing\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-06T06:59:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"320\" \/>\n\t<meta property=\"og:image:height\" content=\"410\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque\",\"url\":\"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque\",\"name\":\"Luer Lock Rigid Tip Cap Unscrewing Torque - ISO 11040-4 Annex G5\",\"isPartOf\":{\"@id\":\"https:\/\/www.syringetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp\",\"datePublished\":\"2025-05-06T06:58:13+00:00\",\"dateModified\":\"2025-05-06T06:59:48+00:00\",\"description\":\"Perform the luer lock rigid tip cap unscrewing torque test following ISO 11040-4 and Annex G5 to ensure syringe quality and compliance.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque#primaryimage\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.syringetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Luer Lock Rigid Tip Cap Unscrewing Torque\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.syringetest.com\/#website\",\"url\":\"https:\/\/www.syringetest.com\/\",\"name\":\"Syringe and Needle Testing\",\"description\":\"Syringe and Needle Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.syringetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.syringetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.syringetest.com\/#organization\",\"name\":\"Syringe and Needle Testing\",\"url\":\"https:\/\/www.syringetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"width\":512,\"height\":512,\"caption\":\"Syringe and Needle Testing\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Luer Lock Rigid Tip Cap Unscrewing Torque - ISO 11040-4 Annex G5","description":"Perform the luer lock rigid tip cap unscrewing torque test following ISO 11040-4 and Annex G5 to ensure syringe quality and compliance.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.syringetest.com\/fr\/luer-lock-rigid-tip-cap-unscrewing-torque\/","og_locale":"fr_FR","og_type":"article","og_title":"Luer Lock Rigid Tip Cap Unscrewing Torque - ISO 11040-4 Annex G5","og_description":"Perform the luer lock rigid tip cap unscrewing torque test following ISO 11040-4 and Annex G5 to ensure syringe quality and compliance.","og_url":"https:\/\/www.syringetest.com\/fr\/luer-lock-rigid-tip-cap-unscrewing-torque\/","og_site_name":"Syringe and Needle Testing","article_modified_time":"2025-05-06T06:59:48+00:00","og_image":[{"width":320,"height":410,"url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque","url":"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque","name":"Luer Lock Rigid Tip Cap Unscrewing Torque - ISO 11040-4 Annex G5","isPartOf":{"@id":"https:\/\/www.syringetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque#primaryimage"},"image":{"@id":"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque#primaryimage"},"thumbnailUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp","datePublished":"2025-05-06T06:58:13+00:00","dateModified":"2025-05-06T06:59:48+00:00","description":"Perform the luer lock rigid tip cap unscrewing torque test following ISO 11040-4 and Annex G5 to ensure syringe quality and compliance.","breadcrumb":{"@id":"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque#primaryimage","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Rigid-Tip-Cap-Unscrewing-Torque-ISO-11040-4-Annex-G5.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.syringetest.com\/luer-lock-rigid-tip-cap-unscrewing-torque#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.syringetest.com\/"},{"@type":"ListItem","position":2,"name":"Luer Lock Rigid Tip Cap Unscrewing Torque"}]},{"@type":"WebSite","@id":"https:\/\/www.syringetest.com\/#website","url":"https:\/\/www.syringetest.com\/","name":"Syringe and Needle Testing","description":"Syringe and Needle Test Solutions","publisher":{"@id":"https:\/\/www.syringetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.syringetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.syringetest.com\/#organization","name":"Syringe and Needle Testing","url":"https:\/\/www.syringetest.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","width":512,"height":512,"caption":"Syringe and Needle Testing"},"image":{"@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/pages\/288","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/comments?post=288"}],"version-history":[{"count":5,"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/pages\/288\/revisions"}],"predecessor-version":[{"id":296,"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/pages\/288\/revisions\/296"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/fr\/wp-json\/wp\/v2\/media?parent=288"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}