{"id":265,"date":"2025-05-06T03:29:29","date_gmt":"2025-05-06T03:29:29","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=265"},"modified":"2026-05-09T06:39:48","modified_gmt":"2026-05-09T06:39:48","slug":"luer-lock-adaptor-collar-pull-off-force","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/fi\/luer-lock-adaptor-collar-pull-off-force","title":{"rendered":"Luer Lock -sovittimen kauluksen irrotusvoima"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"265\" class=\"elementor elementor-265\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0ebe6b e-flex e-con-boxed e-con e-parent\" data-id=\"c0ebe6b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d6d91c9 elementor-widget elementor-widget-heading\" data-id=\"d6d91c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Luer Lock -sovittimen kauluksen irrotusvoima<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0a5f59 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"f0a5f59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L\u00e4\u00e4ke- ja l\u00e4\u00e4kint\u00e4laiteteollisuudessa ruiskun osien eheyden varmistaminen on ratkaisevan t\u00e4rke\u00e4\u00e4. Yksi olennainen laadunvalvonta on t\u00e4m\u00e4 testi. T\u00e4ss\u00e4 arvioinnissa mitataan Luer lock -sovittimen (LLA) kauluksen ja ruiskun tynnyrin v\u00e4lisen liitoksen lujuus, joka est\u00e4\u00e4 komponenttien irtoamisen k\u00e4yt\u00f6n aikana.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7e51b6e e-flex e-con-boxed e-con e-parent\" data-id=\"7e51b6e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a359504 elementor-widget elementor-widget-heading\" data-id=\"a359504\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer Lock -sovittimen kauluksen irrotusvoiman testauksen merkitys<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de744c7 elementor-widget elementor-widget-text-editor\" data-id=\"de744c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Jos Luer lock -sovittimen kauluksen irrotusvoima on liian pieni, kaulus voi irrota ruiskusta k\u00e4sittelyn tai injektion aikana, mik\u00e4 voi johtaa l\u00e4\u00e4kevuotoon, ep\u00e4t\u00e4ydelliseen annosteluun tai jopa vakavaan potilasvahinkoon. Toisaalta jos voima on liian suuri, kokoonpanoprosessit voivat vaikeutua, mik\u00e4 lis\u00e4\u00e4 vaurioitumisriski\u00e4 valmistuksen aikana.<\/p><p>T\u00e4m\u00e4n vuoksi standardoidun testauksen suorittaminen on ratkaisevan t\u00e4rke\u00e4\u00e4, jotta voidaan varmistaa kauluksen turvallinen kiinnitys, s\u00e4ilytt\u00e4\u00e4 ruiskun toimintavarmuus ja suojella potilasturvallisuutta.<\/p><p><strong>Syringetest.com<\/strong> tarjoaa tarkkoja ja luotettavia testauslaitteita <em>Luer lock -sovittimen kauluksen irrotusvoima<\/em> arvioinnit, jotka auttavat varmistamaan, ett\u00e4 ruiskusi t\u00e4ytt\u00e4v\u00e4t maailmanlaajuiset laatustandardit luotettavasti.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f3ad5f2 e-flex e-con-boxed e-con e-parent\" data-id=\"f3ad5f2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d69bf22 elementor-widget elementor-widget-heading\" data-id=\"d69bf22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 ja ISO 11040-4 liite G3.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c32614c e-con-full e-flex e-con e-child\" data-id=\"c32614c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fcd1b36 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"fcd1b36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/www.syringetest.com\/fi\/standards\/iso-11040-4\/\"><em>ISO 11040-4<\/em><\/a> standardi, erityisesti <em>ISO 11040-4 liite G3<\/em>esitet\u00e4\u00e4n menettely, jota noudatetaan <em>Luer lock -sovittimen kauluksen irrotusvoima<\/em> testi. N\u00e4iden standardien mukaan vetovoimatestill\u00e4 varmistetaan kaulusj\u00e4rjestelm\u00e4n kyky kest\u00e4\u00e4 aksiaalisia voimia, mik\u00e4 varmistaa, ett\u00e4 ruiskut pysyv\u00e4t ehjin\u00e4 kriittisten toimintojen, kuten l\u00e4\u00e4kkeiden antamisen, aikana. Menetelm\u00e4ss\u00e4 korostetaan johdonmukaisia testinopeuksia, sopivaa kuormituskennon valintaa ja suurtaajuusn\u00e4ytteenottoa tarkkojen ja luotettavien tietojen varmistamiseksi.<\/p><p>Seuraavat <em>ISO 11040-4 liite G3<\/em> parantaa testien yhdenmukaisuutta laboratorioiden ja valmistajien v\u00e4lill\u00e4, mik\u00e4 edist\u00e4\u00e4 luottamusta tuotteiden laatuun ja s\u00e4\u00e4nn\u00f6sten noudattamiseen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0502b44 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"0502b44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"515\" height=\"350\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" class=\"attachment-medium_large size-medium_large wp-image-272\" alt=\"Luer Lock -adapterin kauluksen irrotusvoima - ISO 11040-4 Liite G3\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp 515w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing-300x204.webp 300w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c33ea3f e-flex e-con-boxed e-con e-parent\" data-id=\"c33ea3f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b8731e5 elementor-widget elementor-widget-heading\" data-id=\"b8731e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer Lock -sovittimen kauluksen irrotusvoimatestin periaate<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-931bcc4 elementor-widget elementor-widget-text-editor\" data-id=\"931bcc4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>T\u00e4m\u00e4n testin ydinajatus on yksinkertainen: siin\u00e4 mitataan suurin aksiaalinen voima, joka tarvitaan LLA-kauluksen irrottamiseen ruiskun tynnyrist\u00e4. Voimakas irrotusvoima tarkoittaa, ett\u00e4 LLA-kaulus on tukevasti kiinni, mik\u00e4 minimoi irtoamisriskin k\u00e4yt\u00f6n aikana.<\/p><p>Keskeinen periaate keskittyy seuraaviin asioihin:<\/p><ul><li>Realistisen mekaanisen rasituksen simulointi.<\/li><li>Varmistetaan, ett\u00e4 tavallisten Luer-liitosten asettamisvoimat eiv\u00e4t aiheuta kauluksen irtoamista.<\/li><li>Huippuvoimatietojen ker\u00e4\u00e4minen voiman ja siirtym\u00e4n v\u00e4lisen analyysin avulla.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cbb1f00 e-flex e-con-boxed e-con e-parent\" data-id=\"cbb1f00\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9e34cbf elementor-widget elementor-widget-heading\" data-id=\"9e34cbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Tarvittavat laitteet ja materiaalit<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29c5058 elementor-widget elementor-widget-text-editor\" data-id=\"29c5058\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Tarkka testaus <em>Luer lock -sovittimen kauluksen irrotusvoima<\/em> vaatii tarkkuuslaitteita:<\/p><ul><li><strong>Yleisk\u00e4ytt\u00f6inen veto- ja puristuskoelaite <\/strong>kanssa:<ul><li>Testinopeudeksi asetetaan 20 mm\/min (tarvittaessa ISO 80369-7:n mukaisesti).<\/li><li>Kuormituskenno soveltuu 10 N - 100 N voima-alueelle.<\/li><\/ul><\/li><li><strong>Ruiskunpidin ja tartuntalaite<\/strong> joka kiinnitt\u00e4\u00e4 sek\u00e4 ruiskun tynnyrin ett\u00e4 LLA-kauluksen ilman ei-toivottua painetta.<\/li><\/ul><p><strong>Materiaalit:<\/strong><\/p><ul><li>T\u00e4ytt\u00f6valmiit, steriloidut, kokoonpannut ruiskut, mukaan lukien LLA-j\u00e4rjestelm\u00e4.<\/li><\/ul><p><strong>T\u00e4rke\u00e4\u00e4:<\/strong><br \/>N\u00e4ytteenottotaajuuden on oltava v\u00e4hint\u00e4\u00e4n 100 Hz yleisiss\u00e4 testeiss\u00e4 ja 500 Hz huippumittauksissa, jotta varmistetaan tietojen hieno erottelukyky ja tarkkuus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-61d3079 e-flex e-con-boxed e-con e-parent\" data-id=\"61d3079\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bd94a54 elementor-widget elementor-widget-heading\" data-id=\"bd94a54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer Lock -sovittimen kauluksen irrotusvoiman testausmenettely Luer Lock -sovittimen kauluksen irrotusvoiman testausmenettely<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc41e63 elementor-widget elementor-widget-text-editor\" data-id=\"fc41e63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>T\u00e4m\u00e4n testin suorittaminen oikein takaa tarkat ja toistettavat tulokset:<\/p><h3>1. N\u00e4ytteen valmistelu<\/h3><p>K\u00e4yt\u00e4 ruiskuja, jotka on steriloitu ja valmisteltu t\u00e4ydellisesti.<\/p><h3>2. Setup<\/h3><ul><li>Irrota k\u00e4rkikorkki varovasti.<\/li><li>Kiinnit\u00e4 ruisku pystysuoraan pidikkeen (sormilaippa) ja tarttujan (LLA-kaulus) v\u00e4liin ilman, ett\u00e4 kaulusta j\u00e4nnitet\u00e4\u00e4n.<\/li><\/ul><h3>3. Testin suorittaminen<\/h3><ul><li>Aseta kuormituskenno nollaan ja varmista, ettei esij\u00e4nnityst\u00e4 ole.<\/li><li>K\u00e4yt\u00e4 vetovoimaa 20 mm\/min.<\/li><li>Kirjaa voima-siirtym\u00e4-k\u00e4yr\u00e4 jatkuvasti.<\/li><\/ul><h3>4. Testin p\u00e4\u00e4tt\u00e4minen<\/h3><p>Lopeta testi, kun LLA-panta irtoaa selv\u00e4sti ruiskusta.<\/p><h3>5. Tulosten tallentaminen<\/h3><p>K\u00e4yr\u00e4n suurin voimahuippu edustaa <em>irrotusvoima<\/em>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc4abbc e-grid e-con-full e-con e-parent\" data-id=\"dc4abbc\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99d351b elementor-widget elementor-widget-image\" data-id=\"99d351b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ccc877e e-con-full e-flex e-con e-child\" data-id=\"ccc877e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef33af7 elementor-widget elementor-widget-heading\" data-id=\"ef33af7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Miksi valita <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b43d751 elementor-widget elementor-widget-text-editor\" data-id=\"b43d751\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"203\" data-end=\"463\">Osoitteessa <strong>Syringetest.com<\/strong>yhdist\u00e4mme asiantuntemuksen ja innovaatiot, tarkan suunnittelun ja yksil\u00f6llisen palvelun tukeaksemme asiakkaitamme kaikkialla maailmassa.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28e0c7c elementor-widget elementor-widget-text-editor\" data-id=\"28e0c7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Suorittaminen <em>Luer lock -sovittimen kauluksen irrotusvoima<\/em> testi <em>ISO 11040-4 liite G3<\/em> on elint\u00e4rke\u00e4\u00e4 Luer lock -ruiskujen mekaanisen turvallisuuden varmistamiseksi. Asianmukainen toteutus ja dokumentointi takaavat, ett\u00e4 ruiskut kest\u00e4v\u00e4t kliinisen k\u00e4yt\u00f6n rasitukset ilman vikoja.<br \/>Luottaa <strong>Syringetest.com<\/strong> huippuluokan testausratkaisuja, jotka parantavat ruiskutuotteidesi laatua ja turvallisuutta.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5463cac elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"5463cac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/fi\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Ota yhteytt\u00e4<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Adaptor Collar Pull-Off Force In the pharmaceutical and medical device industries, ensuring the integrity of syringe components is critical. One essential quality check is the this test. This evaluation measures the strength of the connection between the Luer lock adaptor (LLA) collar and the syringe barrel, preventing component separation during use. The Importance [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-265","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/pages\/265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/comments?post=265"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/pages\/265\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/media?parent=265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}