{"id":173,"date":"2025-04-30T03:56:30","date_gmt":"2025-04-30T03:56:30","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=173"},"modified":"2025-05-06T03:27:04","modified_gmt":"2025-05-06T03:27:04","slug":"front-end-breakage-resistance-iso-11040-4-annex-c2","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/fi\/front-end-breakage-resistance-iso-11040-4-annex-c2","title":{"rendered":"Ruiskun etup\u00e4\u00e4n murtumiskest\u00e4vyyden testaus"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"173\" class=\"elementor elementor-173\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-292be0b e-flex e-con-boxed e-con e-parent\" data-id=\"292be0b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0f48abd elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"0f48abd\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Ruiskun etup\u00e4\u00e4n murtumiskest\u00e4vyyden testaus<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6817f29 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"6817f29\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong>etup\u00e4\u00e4n murtumattomuus<\/strong> on kriittinen laatuparametri l\u00e4\u00e4kepakkauksissa. T\u00e4m\u00e4 ominaisuus varmistaa, ett\u00e4 ruisku kest\u00e4\u00e4 sivuttaiskuormitukset k\u00e4sittelyn, kuljetuksen tai antamisen aikana ilman vikoja. Valmistajille ja laadunvalvonnan ammattilaisille t\u00e4m\u00e4n kest\u00e4vyyden ymm\u00e4rt\u00e4minen ja asianmukainen testaaminen on olennaista potilasturvallisuuden ja tuotteiden vaatimustenmukaisuuden kannalta.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ba0ff14 e-flex e-con-boxed e-con e-parent\" data-id=\"ba0ff14\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea29382 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ea29382\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Irrotus- ja liukuvoiman testauksen merkitys<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-74b25a1 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"74b25a1\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Etup\u00e4\u00e4n murtumattomuus ei ole vain lains\u00e4\u00e4d\u00e4nn\u00f6llinen vaatimus - se on potilaan terveyden ja ruiskun suorituskyvyn turva. Heikot lasik\u00e4rjet voivat rikkoutua kliinisen k\u00e4yt\u00f6n aikana, mik\u00e4 aiheuttaa loukkaantumis-, kontaminaatio- tai annosteluvirheiden riskin. Erityisesti, <a href=\"https:\/\/www.syringetest.com\/fi\/standards\/iso-11040-4\/\"><strong>ISO 11040-4<\/strong><\/a> ja sen normatiivinen <strong>Liite C2<\/strong> m\u00e4\u00e4ritell\u00e4 standardimenetelm\u00e4t ja -vaatimukset t\u00e4m\u00e4n t\u00e4rke\u00e4n testin suorittamiseksi <strong>injektoitavien l\u00e4\u00e4kkeiden lasitynnyrit<\/strong>. Toteuttamalla <strong>ISO 11040-4 testaus<\/strong>, valmistajat voivat:<\/p><ul><li>Havaita suunnittelu- tai materiaalivirheet varhaisessa vaiheessa<\/li><li>Parantaa rakenteellista eheytt\u00e4<\/li><li>Varmistetaan vaatimustenmukaisuus ja asiakkaiden luottamus<\/li><\/ul><p><strong>Syringetest.comin testausj\u00e4rjestelm\u00e4t<\/strong> antaa laboratorioille mahdollisuuden noudattaa maailmanlaajuisia standardeja ja saada aikaan tehokkaita, toistettavia tuloksia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-819cbda e-flex e-con-boxed e-con e-parent\" data-id=\"819cbda\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-851fda3 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"851fda3\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Testaus ja liite C2<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b45964 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"8b45964\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>ISO 11040-4:ss\u00e4 esitet\u00e4\u00e4n eritelm\u00e4t, jotka koskevat <strong>esisteriloidut lasiruiskut<\/strong> ja <strong>ruiskun tynnyrit<\/strong>, varmistaen, ett\u00e4 jokainen komponentti t\u00e4ytt\u00e4\u00e4 l\u00e4\u00e4keturvallisuusvaatimukset. <strong>Liite C2<\/strong> keskittyy erityisesti <strong>etup\u00e4\u00e4n murtumiskest\u00e4vyystesti<\/strong>, mekaaninen testi, joka simuloi ruiskun haavoittuvimman osan - etup\u00e4\u00e4n - todellista rasitusta.<\/p><p>Standardin mukaan:<\/p><ul><li>Testiss\u00e4 arvioidaan <em>maksimivoima<\/em> ruiskun etup\u00e4\u00e4 kest\u00e4\u00e4 ennen murtumista.<\/li><li>Ruiskun tynnyrit (osakokoonpanon kanssa tai ilman) testataan k\u00e4ytt\u00e4m\u00e4ll\u00e4 <strong>universaali veto- ja puristuskoelaite<\/strong>.<\/li><li>A <strong>ruostumattomasta ter\u00e4ksest\u00e4 valmistettu sauva ja pidike<\/strong> simuloi sivuttaiskuormaa painamalla 2 mm:n p\u00e4\u00e4ss\u00e4 ruiskun k\u00e4rjest\u00e4.<\/li><\/ul><p>T\u00e4m\u00e4 testi on pakollinen ISO 11040-4 -standardin kuvissa 2, 3 ja 5 esitetyille lasiruiskujen malleille, jotka edustavat yleisi\u00e4 tynnyrimuotoja.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c73df4 elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-image\" data-id=\"0c73df4\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1190\" height=\"300\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2.webp\" class=\"attachment-full size-full wp-image-192\" alt=\"Ruiskun etuosan murtumiskest\u00e4vyys - ISO 11040-4 Liite C2\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2.webp 1190w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2-300x76.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2-1024x258.webp 1024w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2-768x194.webp 768w\" sizes=\"(max-width: 1190px) 100vw, 1190px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3408e59 e-flex e-con-boxed e-con e-parent\" data-id=\"3408e59\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ace8ed5 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ace8ed5\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ruiskun testauslaitteet ja asennusvaatimukset<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bd23b4c elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"bd23b4c\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Suorita <strong>etup\u00e4\u00e4n murtumiskest\u00e4vyystesti<\/strong>vaatimustenmukaisessa laboratoriossa on oltava seuraavat laitteet:<\/p><ul><li><strong>Yleisk\u00e4ytt\u00f6inen veto- ja puristuskoelaite<\/strong>, joka pystyy yll\u00e4pit\u00e4m\u00e4\u00e4n <strong>25 mm\/min<\/strong> lastausnopeus.<\/li><li>Kuormituskenno, joka on r\u00e4\u00e4t\u00e4l\u00f6ity murtovoimien mittaamiseen, yleens\u00e4 vuonna <strong>newtonit (N)<\/strong>.<\/li><li><strong>Nopea n\u00e4ytteenottokyky<\/strong> (mieluiten 500 Hz huippuvoimamittauksissa).<\/li><li><strong>Sovitinsarja ja kiinnikkeet<\/strong> vastaa ruiskun geometriaa.<\/li><li><strong>Lasiturvallinen pidike ja suojakotelo<\/strong> est\u00e4\u00e4ksesi sirpaloituneiden osien aiheuttamat vammat.<\/li><\/ul><p>Koneen asetukset, testinopeus ja kuormituspisteen tarkkuus (2 mm k\u00e4rjest\u00e4) vaikuttavat merkitt\u00e4v\u00e4sti tulosten luotettavuuteen.<\/p><p><strong>Syringetest.comin ruiskutestausratkaisut<\/strong> integroivat \u00e4lykk\u00e4it\u00e4 ohjelmistorajapintoja, s\u00e4\u00e4dett\u00e4vi\u00e4 kiinnikkeit\u00e4 ja tarkkuusantureita, jotka ovat t\u00e4ysin ISO 11040-4 -standardin vaatimusten mukaisia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-25f2615 e-con-full e-flex e-con e-parent\" data-id=\"25f2615\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-01b0d06 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"01b0d06\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Etup\u00e4\u00e4n rikkoutumiskest\u00e4vyystestin suorittaminen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e636038 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"e636038\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Noudata n\u00e4it\u00e4 ohjeita tarkan <strong>ISO 11040-4 Liite C2 ruiskujen testaus<\/strong>:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5da09eb e-n-tabs-mobile elementor-invisible elementor-widget elementor-widget-n-tabs\" data-id=\"5da09eb\" data-element_type=\"widget\" data-settings=\"{&quot;tabs_justify_horizontal&quot;:&quot;center&quot;,&quot;_animation&quot;:&quot;fadeInUp&quot;,&quot;horizontal_scroll&quot;:&quot;disable&quot;}\" data-widget_type=\"nested-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-tabs\" data-widget-number=\"98175467\" aria-label=\"V\u00e4lilehdet. Avaa kohteita Enterill\u00e4 tai v\u00e4lily\u00f6nnill\u00e4, sulje kohteet Escape-n\u00e4pp\u00e4imell\u00e4 ja navigoi nuolin\u00e4pp\u00e4imill\u00e4.\">\n\t\t\t<div class=\"e-n-tabs-heading\" role=\"tablist\">\n\t\t\t\t\t<button id=\"e-n-tab-title-981754671\" class=\"e-n-tab-title\" aria-selected=\"true\" data-tab-index=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"e-n-tab-content-981754671\" style=\"--n-tabs-title-order: 1;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t1. Valmistele laite:\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-981754672\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-981754672\" style=\"--n-tabs-title-order: 2;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t2. Asenna n\u00e4yte:\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-981754673\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-981754673\" style=\"--n-tabs-title-order: 3;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t3. Suorita testi:\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-981754674\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-981754674\" style=\"--n-tabs-title-order: 4;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t4. J\u00e4lkitestin vaiheet:\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-981754675\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"5\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-981754675\" style=\"--n-tabs-title-order: 5;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t5. Tulosten tulkinta ja dokumentointi\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t\t<\/div>\n\t\t\t<div class=\"e-n-tabs-content\">\n\t\t\t\t<div id=\"e-n-tab-content-981754671\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-981754671\" data-tab-index=\"1\" style=\"--n-tabs-title-order: 1;\" class=\"e-active elementor-element elementor-element-1d211a8 e-flex e-con-boxed e-con e-child\" data-id=\"1d211a8\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7bbe7c7 elementor-widget elementor-widget-text-editor\" data-id=\"7bbe7c7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Tarkista sovittimen yhteensopivuus ja eheys.<\/li><li>Tarkista ohjelmistokokoonpano ja turvakotelot.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-981754672\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-981754672\" data-tab-index=\"2\" style=\"--n-tabs-title-order: 2;\" class=\"elementor-element elementor-element-dcb05d7 e-flex e-con-boxed e-con e-child\" data-id=\"dcb05d7\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-010d854 elementor-widget elementor-widget-text-editor\" data-id=\"010d854\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Aseta ruiskun tynnyri pidikkeeseen.<\/li><li>Varmista, ett\u00e4 etup\u00e4\u00e4 kohdistuu tarkasti lastausnastan kanssa.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-981754673\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-981754673\" data-tab-index=\"3\" style=\"--n-tabs-title-order: 3;\" class=\"elementor-element elementor-element-b79b80d e-flex e-con-boxed e-con e-child\" data-id=\"b79b80d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f28f508 elementor-widget elementor-widget-text-editor\" data-id=\"f28f508\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Aseta nopeudeksi 25 mm\/min.<\/li><li>Aloita puristus, kunnes piipun etup\u00e4\u00e4 katkeaa.<\/li><li>Tallenna <em>suurin murtumisvoima<\/em>.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-981754674\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-981754674\" data-tab-index=\"4\" style=\"--n-tabs-title-order: 4;\" class=\"elementor-element elementor-element-4e415a1 e-flex e-con-boxed e-con e-child\" data-id=\"4e415a1\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-698763a elementor-widget elementor-widget-text-editor\" data-id=\"698763a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Poista ja h\u00e4vit\u00e4 lasinsirut turvallisesti.<\/li><li>Puhdista ja nollaa kiinnikkeet ennen seuraavaa testi\u00e4.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-981754675\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-981754675\" data-tab-index=\"5\" style=\"--n-tabs-title-order: 5;\" class=\"elementor-element elementor-element-bc03b00 e-flex e-con-boxed e-con e-child\" data-id=\"bc03b00\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0cce7a elementor-widget elementor-widget-text-editor\" data-id=\"c0cce7a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Testi\u00e4 pidet\u00e4\u00e4n p\u00e4tev\u00e4n\u00e4, kun rikkoutuminen tapahtuu etup\u00e4\u00e4ss\u00e4 m\u00e4\u00e4ritellyiss\u00e4 olosuhteissa. Testiraportin on sis\u00e4llett\u00e4v\u00e4:<\/p><ol><li>K\u00e4ytetty testinopeus (mm\/min)<\/li><li>Voiman k\u00e4ytt\u00f6et\u00e4isyys (\u22482 mm k\u00e4rjest\u00e4)<\/li><li>Suurin murtovoima (N)<\/li><li>Testin\u00e4ytteiden lukum\u00e4\u00e4r\u00e4<\/li><li>Mahdolliset poikkeamat tai poikkeavuudet<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f767c95 e-con-full e-flex e-con e-parent\" data-id=\"f767c95\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-709c163 e-grid e-con-full e-con e-child\" data-id=\"709c163\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-a4a7944 e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"a4a7944\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e4afee6 e-flex e-con-boxed elementor-invisible e-con e-child\" data-id=\"e4afee6\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInRight&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-89f42f9 elementor-widget__width-initial elementor-widget elementor-widget-heading\" data-id=\"89f42f9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Miksi valita <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57329e7 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"57329e7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ymm\u00e4rt\u00e4minen ja soveltaminen <strong>etup\u00e4\u00e4n murtumattomuus<\/strong> testaaminen, sellaisena kuin se on m\u00e4\u00e4ritelty <strong><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Liite C2<\/strong> varmistaa, ett\u00e4 ruiskutuotteet t\u00e4ytt\u00e4v\u00e4t tiukat turvallisuusodotukset. Olitpa sitten valmistaja, s\u00e4\u00e4ntelyst\u00e4 vastaava virkailija tai laadunvalvontainsin\u00f6\u00f6ri, tarkka ja vaatimustenmukainen testaus on v\u00e4ltt\u00e4m\u00e4t\u00f6nt\u00e4.<\/p><p><strong>Syringetest.com<\/strong> toimittaa <strong>luotettavat, standardien mukaiset ruiskutestausratkaisut<\/strong> jotka virtaviivaistavat ty\u00f6nkulkuja ja vahvistavat tuotteiden suorituskyky\u00e4. Tutustu koko valikoimaamme l\u00e4\u00e4ketieteellisten pakkausten testauslaitteita ja paranna laboratoriosi valmiuksia jo t\u00e4n\u00e4\u00e4n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3dc500d elementor-widget elementor-widget-eael-creative-button\" data-id=\"3dc500d\" data-element_type=\"widget\" data-widget_type=\"eael-creative-button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-creative-button-wrapper\">\n\n            <a class=\"eael-creative-button eael-creative-button--default\" href=\"#\" data-text=\"Contact Us\">\n\n\t    \n                <div class=\"creative-button-inner\">\n\n                    \n                    <span class=\"cretive-button-text\">Ota yhteytt\u00e4<\/span>\n\n                                    <\/div>\n\t                        <\/a>\n        <\/div>\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Syringe Front End Breakage Resistance Testing The front end breakage resistance of a syringe is a critical quality parameter in pharmaceutical packaging. This attribute ensures that the syringe can withstand side loads during handling, transportation, or administration without failure. For manufacturers and quality control professionals, understanding and properly testing this resistance is essential to patient [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-173","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Syringe Front End Breakage Resistance - ISO 11040-4 Annex C2<\/title>\n<meta name=\"description\" content=\"Learn how to test syringe front end breakage resistance of syringes per ISO 11040-4 Annex C2. Syringe testing for quality control.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.syringetest.com\/fi\/front-end-breakage-resistance-iso-11040-4-annex-c2\/\" \/>\n<meta property=\"og:locale\" content=\"fi_FI\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Syringe Front End Breakage Resistance - ISO 11040-4 Annex C2\" \/>\n<meta property=\"og:description\" content=\"Learn how to test syringe front end breakage resistance of syringes per ISO 11040-4 Annex C2. Syringe testing for quality control.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.syringetest.com\/fi\/front-end-breakage-resistance-iso-11040-4-annex-c2\/\" \/>\n<meta property=\"og:site_name\" content=\"Syringe and Needle Testing\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-06T03:27:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2.webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Arvioitu lukuaika\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuuttia\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2\",\"url\":\"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2\",\"name\":\"Syringe Front End Breakage Resistance - ISO 11040-4 Annex C2\",\"isPartOf\":{\"@id\":\"https:\/\/www.syringetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2.webp\",\"datePublished\":\"2025-04-30T03:56:30+00:00\",\"dateModified\":\"2025-05-06T03:27:04+00:00\",\"description\":\"Learn how to test syringe front end breakage resistance of syringes per ISO 11040-4 Annex C2. Syringe testing for quality control.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2#breadcrumb\"},\"inLanguage\":\"fi\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fi\",\"@id\":\"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2#primaryimage\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.syringetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Syringe Front End Breakage Resistance Testing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.syringetest.com\/#website\",\"url\":\"https:\/\/www.syringetest.com\/\",\"name\":\"Syringe and Needle Testing\",\"description\":\"Syringe and Needle Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.syringetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.syringetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fi\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.syringetest.com\/#organization\",\"name\":\"Syringe and Needle Testing\",\"url\":\"https:\/\/www.syringetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fi\",\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"width\":512,\"height\":512,\"caption\":\"Syringe and Needle Testing\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Syringe Front End Breakage Resistance - ISO 11040-4 Annex C2","description":"Learn how to test syringe front end breakage resistance of syringes per ISO 11040-4 Annex C2. Syringe testing for quality control.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.syringetest.com\/fi\/front-end-breakage-resistance-iso-11040-4-annex-c2\/","og_locale":"fi_FI","og_type":"article","og_title":"Syringe Front End Breakage Resistance - ISO 11040-4 Annex C2","og_description":"Learn how to test syringe front end breakage resistance of syringes per ISO 11040-4 Annex C2. Syringe testing for quality control.","og_url":"https:\/\/www.syringetest.com\/fi\/front-end-breakage-resistance-iso-11040-4-annex-c2\/","og_site_name":"Syringe and Needle Testing","article_modified_time":"2025-05-06T03:27:04+00:00","og_image":[{"url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2.webp","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Arvioitu lukuaika":"4 minuuttia"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2","url":"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2","name":"Syringe Front End Breakage Resistance - ISO 11040-4 Annex C2","isPartOf":{"@id":"https:\/\/www.syringetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2#primaryimage"},"image":{"@id":"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2#primaryimage"},"thumbnailUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2.webp","datePublished":"2025-04-30T03:56:30+00:00","dateModified":"2025-05-06T03:27:04+00:00","description":"Learn how to test syringe front end breakage resistance of syringes per ISO 11040-4 Annex C2. Syringe testing for quality control.","breadcrumb":{"@id":"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2#breadcrumb"},"inLanguage":"fi","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2"]}]},{"@type":"ImageObject","inLanguage":"fi","@id":"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2#primaryimage","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Front-End-Breakage-Resistance-ISO-11040-4-Annex-C2.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.syringetest.com\/front-end-breakage-resistance-iso-11040-4-annex-c2#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.syringetest.com\/"},{"@type":"ListItem","position":2,"name":"Syringe Front End Breakage Resistance Testing"}]},{"@type":"WebSite","@id":"https:\/\/www.syringetest.com\/#website","url":"https:\/\/www.syringetest.com\/","name":"Syringe and Needle Testing","description":"Syringe and Needle Test Solutions","publisher":{"@id":"https:\/\/www.syringetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.syringetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fi"},{"@type":"Organization","@id":"https:\/\/www.syringetest.com\/#organization","name":"Syringe and Needle Testing","url":"https:\/\/www.syringetest.com\/","logo":{"@type":"ImageObject","inLanguage":"fi","@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","width":512,"height":512,"caption":"Syringe and Needle Testing"},"image":{"@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/pages\/173","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/comments?post=173"}],"version-history":[{"count":5,"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/pages\/173\/revisions"}],"predecessor-version":[{"id":243,"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/pages\/173\/revisions\/243"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/fi\/wp-json\/wp\/v2\/media?parent=173"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}