{"id":492,"date":"2025-06-04T05:44:42","date_gmt":"2025-06-04T05:44:42","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=492"},"modified":"2026-05-19T08:11:59","modified_gmt":"2026-05-19T08:11:59","slug":"syringe-liquid-leakage-test-for-closure-system","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/et\/syringe-liquid-leakage-test-for-closure-system","title":{"rendered":"Sulgemiss\u00fcsteemi vedeliku lekkekatse s\u00fcstla jaoks"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"492\" class=\"elementor elementor-492\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-14a7ec1 e-flex e-con-boxed e-con e-parent\" data-id=\"14a7ec1\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8ba13c0 elementor-widget elementor-widget-heading\" data-id=\"8ba13c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">S\u00fcstalde sulgemiss\u00fcsteemi vedeliku lekke katse<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bbb28e6 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"bbb28e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"401\" data-end=\"1099\">Ravimi- ja meditsiiniseadmete t\u00f6\u00f6stuses on s\u00fcstlate terviklikkuse tagamine tooteohutuse ja patsiendi tervise seisukohast v\u00e4ga oluline. \u00dcks olulisemaid protseduure on <strong data-start=\"602\" data-end=\"633\">s\u00fcstla vedeliku lekkekatse<\/strong>, millega hinnatakse s\u00fcstla kolvi ja sulgemiss\u00fcsteemi v\u00f5imet v\u00e4ltida vedeliku lekkeid r\u00f5hu all. K\u00e4esolevas artiklis antakse p\u00f5hjalik juhend selle kohta, kuidas viia l\u00e4bi s\u00fcstla vedeliku lekkekatse koosk\u00f5las j\u00e4rgmisega <strong data-start=\"862\" data-end=\"884\"><a href=\"https:\/\/www.syringetest.com\/et\/standards\/iso-7886-1\/\">ISO 7886-1<\/a> D lisa<\/strong> ja <strong data-start=\"889\" data-end=\"913\"><a href=\"https:\/\/www.syringetest.com\/et\/standards\/iso-11040-4\/\">ISO 11040-4<\/a> Lisa G2<\/strong> standardid. Juhtiva t\u00e4ppiskatseseadmete tootjana, <strong data-start=\"985\" data-end=\"1005\">Cell Instruments<\/strong> pakub usaldusv\u00e4\u00e4rseid lahendusi spetsialistidele ja kvaliteedikontrolli personalile s\u00fcstlakatsetustes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb57b12 e-flex e-con-boxed e-con e-parent\" data-id=\"cb57b12\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c5f7942 elementor-widget elementor-widget-heading\" data-id=\"c5f7942\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">S\u00fcstalde vedeliku lekke testi m\u00f5istmine<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24b1f4a elementor-widget elementor-widget-text-editor\" data-id=\"24b1f4a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1106\" data-end=\"1433\">The <strong data-start=\"1162\" data-end=\"1193\">s\u00fcstla vedeliku lekkekatse<\/strong> tagab, et s\u00fcstlad j\u00e4\u00e4vad lekkekindlaks ka r\u00f5hu all. See hindab nii kolvi korgi kui ka sulgemiss\u00fcsteemi (otsakork v\u00f5i n\u00f5elakaitse) tihedust, kaitstes nii saastumise ja doseerimisvigade eest.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0f9719a e-flex e-con-boxed e-con e-parent\" data-id=\"0f9719a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9a70f61 elementor-widget elementor-widget-heading\" data-id=\"9a70f61\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">S\u00fcstla vedeliku lekkekatse vastavalt ISO 7886-1 D lisale<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6461ae4 elementor-widget elementor-widget-text-editor\" data-id=\"6461ae4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1440\" data-end=\"1622\"><strong data-start=\"1506\" data-end=\"1528\">ISO 7886-1 D lisa<\/strong> visandab t\u00e4pse meetodi s\u00fcstla kolbistopperi tihendusv\u00f5ime hindamiseks.<\/p><h3 data-start=\"1440\" data-end=\"1622\">Katse p\u00f5him\u00f5te<\/h3><p data-start=\"1624\" data-end=\"1847\">S\u00fcstel t\u00e4idetakse destilleeritud veega, suletakse otsakuga ja sellele rakendatakse nii aksiaalseid kui ka radiaalseid j\u00f5ude. Eesm\u00e4rk on simuleerida pingeid, mis v\u00f5ivad p\u00f5hjustada vedeliku lekkimist kolvi korgi vahelt.<\/p><h3 data-start=\"1624\" data-end=\"1847\">Seadmed ja reaktiivid<\/h3><ul><li><strong data-start=\"1880\" data-end=\"1898\">Tihendusseade<\/strong>: T\u00e4ielikult sulgeda v\u00f5i sulgeda s\u00fcstla otsik.<\/li><li><strong data-start=\"1949\" data-end=\"1977\">Force Application Device (j\u00f5u rakendusseade)<\/strong>: rakendada kolbile k\u00fclgsuunalist j\u00f5udu 0,25 N kuni 3 N.<\/li><li><strong data-start=\"2042\" data-end=\"2061\">R\u00f5hu seade<\/strong>: V\u00f5imaldab tekitada r\u00f5hku <strong data-start=\"2098\" data-end=\"2109\">200 kPa<\/strong> ja <strong data-start=\"2114\" data-end=\"2125\">300 kPa<\/strong>.<\/li><li><strong data-start=\"2131\" data-end=\"2150\">Destilleeritud vesi<\/strong>: S\u00e4ilitatakse ajavahemikus <strong data-start=\"2171\" data-end=\"2189\">18 \u00b0C kuni 28 \u00b0C<\/strong>.<\/li><\/ul><h3 data-start=\"1624\" data-end=\"1847\">Katsemenetlus<\/h3><ol><li data-start=\"2216\" data-end=\"2283\">T\u00e4itke s\u00fcstel destilleeritud veega \u00fcle selle nimimahutavuse.<\/li><li data-start=\"2287\" data-end=\"2343\">V\u00e4ljendage \u00f5hk ja reguleerige veemaht nimimahule.<\/li><li data-start=\"2347\" data-end=\"2373\">Tihendage s\u00fcstla otsik.<\/li><li data-start=\"2377\" data-end=\"2454\">Maksimaalse radiaalse l\u00e4bipainde saavutamiseks rakendage kolbile k\u00fclgsuunalist j\u00f5udu.<\/li><li data-start=\"2458\" data-end=\"2522\">Looge vajalik r\u00f5hk ja hoidke seda 30-35 sekundit.<\/li><li data-start=\"2526\" data-end=\"2596\">Kontrollige s\u00fcstalt, et ei oleks vedeliku lekkeid, mis on kolvi korgist m\u00f6\u00f6dunud.<\/li><\/ol><h3 data-start=\"1624\" data-end=\"1847\">T\u00e4htsus<\/h3><p data-start=\"2598\" data-end=\"2733\">See katse simuleerib k\u00e4itlemispingeid, et kontrollida, kas <strong data-start=\"2674\" data-end=\"2693\">s\u00fcstla kolb<\/strong> s\u00e4ilitab r\u00f5hu all kindla tihendi.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0e39f22 e-flex e-con-boxed e-con e-parent\" data-id=\"0e39f22\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9e4bce6 elementor-widget elementor-widget-heading\" data-id=\"9e4bce6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">S\u00fcstalde sulgemise lekkekatse: ISO 11040-4 lisa G2<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f35e53 elementor-widget elementor-widget-text-editor\" data-id=\"2f35e53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2740\" data-end=\"2956\">The <strong data-start=\"2798\" data-end=\"2848\">ISO 11040-4 lisa G2 s\u00fcstla sulgemise lekkekatse<\/strong> keskendub j\u00e4rgmiste meetmete tulemuslikkuse hindamisele <strong data-start=\"2889\" data-end=\"2916\">s\u00fcstla sulgemiss\u00fcsteemid<\/strong>, sealhulgas otsakorgid ja n\u00f5elakilbid.<\/p><h3 data-start=\"2740\" data-end=\"2956\">Katse p\u00f5him\u00f5te<\/h3><p data-start=\"2958\" data-end=\"3123\">Eesm\u00e4rk on kontrollida, et s\u00fcstla sulgemiss\u00fcsteem peab vastu v\u00f5imalikule \u00fcler\u00f5hule t\u00e4itmise v\u00f5i transportimise ajal, v\u00e4ltides lekkeid.<\/p><h3 data-start=\"2740\" data-end=\"2956\">Katsemenetlus<\/h3><ol><li data-start=\"3149\" data-end=\"3208\">T\u00e4itke s\u00fcstal kuni <strong data-start=\"3169\" data-end=\"3183\">1\/3 kuni 2\/3<\/strong> nimimahust.<\/li><li data-start=\"3212\" data-end=\"3268\">Sisestage s\u00fcstel testihoidikusse ja kinnitage see.<\/li><li data-start=\"3272\" data-end=\"3322\">Rakenda <strong data-start=\"3278\" data-end=\"3289\">110 kPa<\/strong> survestamise eest <strong data-start=\"3306\" data-end=\"3319\">5 sekundit<\/strong>.<\/li><li data-start=\"3326\" data-end=\"3398\">J\u00e4lgige s\u00fcstalt, kas katse ajal ja p\u00e4rast seda ei leki n\u00e4htavalt.<\/li><li data-start=\"3402\" data-end=\"3544\">Vabastage r\u00f5hk ja hinnake s\u00fcsteemi: test on l\u00e4bitud, kui otsakorgid v\u00f5i n\u00f5elakilbid j\u00e4\u00e4vad paika ja v\u00e4liselt ei teki tilkasid.<\/li><\/ol><h3 data-start=\"2740\" data-end=\"2956\">J\u00f5u arvutamine<\/h3><p data-start=\"3546\" data-end=\"3669\">Siser\u00f5hu j\u00f5ud (<strong data-start=\"3602\" data-end=\"3607\">F<\/strong>) saab arvutada j\u00e4rgmiselt:<br data-start=\"3632\" data-end=\"3635\" \/>F = p \u00d7 \u03c0\/4 \u00d7 d\u00b2 \u00d7 10-\u00b3<br data-start=\"3658\" data-end=\"3661\" \/>kus:<\/p><ul><li data-start=\"3672\" data-end=\"3685\">p = 110 kPa<\/li><li data-start=\"3688\" data-end=\"3743\">d = s\u00fcstlatoru nominaalne sisel\u00e4bim\u00f5\u00f5t (mm)<\/li><\/ul><p data-start=\"3745\" data-end=\"3840\">See tagab t\u00e4pse ja j\u00e4rjepideva surve avaldamise s\u00fcstlasse katse ajal.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f6abf6 e-flex e-con-boxed e-con e-parent\" data-id=\"9f6abf6\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cabb0a8 elementor-widget elementor-widget-heading\" data-id=\"cabb0a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Cell Instrumentsi testimislahenduste kasutamise eelised<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e08dd76 elementor-widget elementor-widget-text-editor\" data-id=\"e08dd76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3847\" data-end=\"4059\"><strong data-start=\"3907\" data-end=\"3927\">Cell Instruments<\/strong> pakub t\u00e4iustatud ja kohandatavat <strong data-start=\"3961\" data-end=\"3992\">s\u00fcstla vedeliku lekkekatse<\/strong> ISO standarditele kohandatud seadmed. Meie katselahendused:<\/p><ul><li data-start=\"4062\" data-end=\"4106\">Anda t\u00e4pseid ja korratavaid tulemusi.<\/li><li data-start=\"4109\" data-end=\"4155\">Sobib erinevate suuruste ja t\u00fc\u00fcbidega s\u00fcstlaid.<\/li><li data-start=\"4158\" data-end=\"4221\">Integreerub sujuvalt olemasolevatesse kvaliteedikontrolli t\u00f6\u00f6voogudesse.<\/li><\/ul><p data-start=\"4223\" data-end=\"4349\"><strong data-start=\"4223\" data-end=\"4251\">Kohandatud testimislahendused<\/strong> ja <strong data-start=\"4256\" data-end=\"4294\">automatiseerimise \u00fcmberkujundamise teenused<\/strong> tagada kohandatavus konkreetsete testimisn\u00f5uete jaoks.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-95bd826 e-flex e-con-boxed e-con e-parent\" data-id=\"95bd826\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-dd9a294 e-con-full e-flex e-con e-child\" data-id=\"dd9a294\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-350f1cc elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"350f1cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"465\" height=\"1024\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-465x1024.webp\" class=\"attachment-large size-large wp-image-494\" alt=\"Sulgemiss\u00fcsteemi vedeliku lekkekatse s\u00fcstla jaoks\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-465x1024.webp 465w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-136x300.webp 136w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-768x1690.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-698x1536.webp 698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-931x2048.webp 931w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/06\/Syringe-Liquid-Leakage-Test-for-Closure-System-scaled.webp 1164w\" sizes=\"(max-width: 465px) 100vw, 465px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6a72395 e-con-full e-flex e-con e-child\" data-id=\"6a72395\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1a711e6 elementor-widget elementor-widget-heading\" data-id=\"1a711e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Miks valida <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e791ed8 elementor-widget elementor-widget-text-editor\" data-id=\"e791ed8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong data-start=\"4377\" data-end=\"4408\">s\u00fcstla vedeliku lekkekatse<\/strong> on oluline ravimirakendustes kasutatavate s\u00fcstlite terviklikkuse valideerimiseks. J\u00e4rgides suuniseid, mille on kehtestanud <strong data-start=\"4527\" data-end=\"4549\">ISO 7886-1 D lisa<\/strong> ja <strong data-start=\"4554\" data-end=\"4578\">ISO 11040-4 lisa G2<\/strong> tagab n\u00f5uetele vastavuse, toote usaldusv\u00e4\u00e4rsuse ja patsiendi ohutuse. Usaldage <strong data-start=\"4646\" data-end=\"4666\">Cell Instruments<\/strong> ekspertide testimislahenduste ja kohandatud toetuse saamiseks, et parandada teie s\u00fcstla kvaliteedikontrolli protsesse.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c65166e elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"c65166e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/et\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">V\u00f5tke meiega \u00fchendust<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Syringe Closure System Liquid Leakage Test In the pharmaceutical and medical device industries, ensuring the integrity of syringes is crucial for product safety and patient health. One of the most essential procedures is the syringe liquid leakage test, which evaluates the ability of a syringe\u2019s plunger and closure system to prevent liquid leaks under pressure. [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-492","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages\/492","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/comments?post=492"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages\/492\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/media?parent=492"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}