{"id":265,"date":"2025-05-06T03:29:29","date_gmt":"2025-05-06T03:29:29","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=265"},"modified":"2025-05-06T03:56:17","modified_gmt":"2025-05-06T03:56:17","slug":"luer-lock-adaptor-collar-pull-off-force","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/et\/luer-lock-adaptor-collar-pull-off-force","title":{"rendered":"Luer Lock adapteri krae v\u00e4ljat\u00f5mbej\u00f5ud"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"265\" class=\"elementor elementor-265\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-292be0b e-flex e-con-boxed e-con e-parent\" data-id=\"292be0b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0f48abd elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"0f48abd\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer Lock adapteri krae v\u00e4ljat\u00f5mbej\u00f5ud<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6817f29 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"6817f29\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In the pharmaceutical and medical device industries, ensuring the integrity of syringe components is critical. One essential quality check is the this test. This evaluation measures the strength of the connection between the Luer lock adaptor (LLA) collar and the syringe barrel, preventing component separation during use.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad68bc6 e-flex e-con-boxed e-con e-parent\" data-id=\"ad68bc6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ecf369e elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ecf369e\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">The Importance of Luer Lock Adaptor Collar Pull-Off Force Testing<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f390758 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"f390758\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>If the pull-off force of the Luer lock adaptor collar is too low, the collar may detach from the syringe during handling or injection, leading to medication leakage, incomplete dosing, or even serious patient injury. On the other hand, if the force is too high, assembly processes may become difficult, increasing the risk of damage during manufacturing.<\/p><p>Therefore, conducting standardized this testing is critical to ensure the secure attachment of the collar, maintain the functional reliability of the syringe, and protect patient safety.<\/p><p><strong>Syringetest.com<\/strong> offers precise, reliable testing equipment for <em>Luer lock adaptor collar pull-off force<\/em> assessments, helping ensure your syringes meet global quality standards with confidence.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4835ce e-flex e-con-boxed e-con e-parent\" data-id=\"d4835ce\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea29382 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ea29382\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 and ISO 11040-4 Annex G3<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-55047da e-con-full e-flex e-con e-child\" data-id=\"55047da\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-ae8face e-con-full e-flex e-con e-child\" data-id=\"ae8face\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-42248e5 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"42248e5\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInLeft&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/www.syringetest.com\/et\/standards\/iso-11040-4\/\"><em>ISO 11040-4<\/em><\/a> standard, particularly <em>ISO 11040-4 Annex G3<\/em>, outlines the procedure for the <em>Luer lock adaptor collar pull-off force<\/em> test. According to these standards, the pull-off force test verifies the collar system\u2019s ability to withstand axial forces, ensuring that syringes remain intact during critical operations such as medication administration. The method emphasizes consistent test speeds, appropriate load cell selection, and high-frequency sampling to ensure accurate, reliable data.<\/p><p>Following <em>ISO 11040-4 Annex G3<\/em> improves test consistency across laboratories and manufacturers, fostering trust in product quality and regulatory compliance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fda7334 e-con-full e-flex e-con e-child\" data-id=\"fda7334\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a601c24 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-image\" data-id=\"a601c24\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInRight&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"515\" height=\"350\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" class=\"attachment-large size-large wp-image-272\" alt=\"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp 515w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing-300x204.webp 300w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-41ab1d6 e-flex e-con-boxed e-con e-parent\" data-id=\"41ab1d6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-48c60fb elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"48c60fb\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Principle of the Luer Lock Adaptor Collar Pull-Off Force Test<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c5b3e59 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"c5b3e59\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The core idea behind this\u00a0test is simple: it measures the maximum axial force required to detach the LLA collar from the syringe barrel. A strong pull-off force means the LLA collar is securely attached, minimizing the risk of disconnection during use.<\/p><p>The key principle focuses on:<\/p><ul><li>Simulating realistic mechanical stress.<\/li><li>Ensuring that insertion forces from standard Luer fittings do not cause collar detachment.<\/li><li>Collecting peak force data through force versus displacement analysis.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad468be e-flex e-con-boxed e-con e-parent\" data-id=\"ad468be\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-edb7717 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"edb7717\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Required Apparatus and Materials<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5810d33 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"5810d33\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Accurate testing of <em>Luer lock adaptor collar pull-off force<\/em> demands precision equipment:<\/p><ul><li><strong>Universaalne t\u00f5mbe- ja survekatse masin <\/strong>with:<ul><li>Test speed set at 20 mm\/min (as per ISO 80369-7, if appropriate).<\/li><li>Load cell suitable for 10 N to 100 N force range.<\/li><\/ul><\/li><li><strong>Syringe holder and gripper device<\/strong> that secures both the syringe barrel and the LLA collar without applying unwanted pressure.<\/li><\/ul><p><strong>Materials:<\/strong><\/p><ul><li>Sterilized subassembled syringes ready for filling, including the LLA system.<\/li><\/ul><p><strong>Important:<\/strong><br \/>The sampling rate must be no less than 100 Hz for general tests, and 500 Hz for peak measurements, ensuring fine data resolution and accuracy.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-285667c e-con-full e-flex e-con e-parent\" data-id=\"285667c\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f7c629 elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"3f7c629\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer Lock Adaptor Collar Pull-Off Force Test Procedure<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f6e7fda elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"f6e7fda\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Performing this\u00a0test correctly ensures accurate, repeatable results:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d737d1 e-n-tabs-mobile elementor-invisible elementor-widget elementor-widget-n-tabs\" data-id=\"9d737d1\" data-element_type=\"widget\" data-settings=\"{&quot;tabs_justify_horizontal&quot;:&quot;center&quot;,&quot;_animation&quot;:&quot;fadeInUp&quot;,&quot;horizontal_scroll&quot;:&quot;disable&quot;}\" data-widget_type=\"nested-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-tabs\" data-widget-number=\"165099473\" aria-label=\"Registerkarten. \u00d6ffnen Sie Elemente mit Enter oder Space, schlie\u00dfen Sie sie mit Escape und navigieren Sie mit den Pfeiltasten.\" data-no-translation-aria-label=\"\">\n\t\t\t<div class=\"e-n-tabs-heading\" role=\"tablist\">\n\t\t\t\t\t<button id=\"e-n-tab-title-1650994731\" class=\"e-n-tab-title\" aria-selected=\"true\" data-tab-index=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"e-n-tab-content-1650994731\" style=\"--n-tabs-title-order: 1;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t1. Sample Preparation\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1650994732\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1650994732\" style=\"--n-tabs-title-order: 2;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t2. Setup\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1650994733\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1650994733\" style=\"--n-tabs-title-order: 3;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t3. Test Execution\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1650994734\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1650994734\" style=\"--n-tabs-title-order: 4;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t4. Ending the Test\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1650994735\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"5\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1650994735\" style=\"--n-tabs-title-order: 5;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t5. Result Recording\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t\t<\/div>\n\t\t\t<div class=\"e-n-tabs-content\">\n\t\t\t\t<div id=\"e-n-tab-content-1650994731\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994731\" data-tab-index=\"1\" style=\"--n-tabs-title-order: 1;\" class=\"e-active elementor-element elementor-element-e75ed08 e-flex e-con-boxed e-con e-child\" data-id=\"e75ed08\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f3434b1 elementor-widget elementor-widget-text-editor\" data-id=\"f3434b1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Use syringes that have undergone the full sterilization and preparation process.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1650994732\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994732\" data-tab-index=\"2\" style=\"--n-tabs-title-order: 2;\" class=\"elementor-element elementor-element-f886d7d e-flex e-con-boxed e-con e-child\" data-id=\"f886d7d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f5549bf elementor-widget elementor-widget-text-editor\" data-id=\"f5549bf\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Remove the tip cap carefully.<\/li><li>Secure the syringe vertically between the holder (finger flange) and gripper (LLA collar) without stressing the collar.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1650994733\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994733\" data-tab-index=\"3\" style=\"--n-tabs-title-order: 3;\" class=\"elementor-element elementor-element-8a12e10 e-flex e-con-boxed e-con e-child\" data-id=\"8a12e10\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3c766c8 elementor-widget elementor-widget-text-editor\" data-id=\"3c766c8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Set the load cell to zero, ensuring no preload.<\/li><li>Apply a pulling force at 20 mm\/min.<\/li><li>Record the force versus displacement curve continuously.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1650994734\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994734\" data-tab-index=\"4\" style=\"--n-tabs-title-order: 4;\" class=\"elementor-element elementor-element-b3f1f40 e-flex e-con-boxed e-con e-child\" data-id=\"b3f1f40\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-904eb23 elementor-widget elementor-widget-text-editor\" data-id=\"904eb23\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Stop the test when the LLA collar clearly separates from the syringe.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1650994735\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994735\" data-tab-index=\"5\" style=\"--n-tabs-title-order: 5;\" class=\"elementor-element elementor-element-af75195 e-flex e-con-boxed e-con e-child\" data-id=\"af75195\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f9a6a49 elementor-widget elementor-widget-text-editor\" data-id=\"f9a6a49\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The maximum force peak on the curve represents the <em>pull-off force<\/em>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b581cc e-con-full e-flex e-con e-parent\" data-id=\"1b581cc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-61afd37 e-grid e-con-full e-con e-child\" data-id=\"61afd37\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-f8ace73 e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"f8ace73\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94cc5ad e-flex e-con-boxed elementor-invisible e-con e-child\" data-id=\"94cc5ad\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInRight&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-907b713 elementor-widget elementor-widget-heading\" data-id=\"907b713\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Miks valida <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-718f32f elementor-widget elementor-widget-text-editor\" data-id=\"718f32f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>T\u00e4itmine <em>Luer lock adaptor collar pull-off force<\/em> test vastavalt <em>ISO 11040-4 Annex G3<\/em> is vital for ensuring the mechanical security of Luer lock syringes. Proper execution and documentation provide assurance that the syringes can endure the stresses of clinical use without failure.<br \/>Rely on <strong>Syringetest.com<\/strong> for cutting-edge testing solutions that elevate the quality and safety of your syringe products.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f735b94 elementor-widget elementor-widget-eael-creative-button\" data-id=\"f735b94\" data-element_type=\"widget\" data-widget_type=\"eael-creative-button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-creative-button-wrapper\">\n\n            <a class=\"eael-creative-button eael-creative-button--default\" href=\"#\" data-text=\"Contact Us\">\n\n\t    \n                <div class=\"creative-button-inner\">\n\n                    \n                    <span class=\"cretive-button-text\">V\u00f5tke meiega \u00fchendust<\/span>\n\n                                    <\/div>\n\t                        <\/a>\n        <\/div>\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Adaptor Collar Pull-Off Force In the pharmaceutical and medical device industries, ensuring the integrity of syringe components is critical. One essential quality check is the this test. This evaluation measures the strength of the connection between the Luer lock adaptor (LLA) collar and the syringe barrel, preventing component separation during use. The Importance [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-265","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3<\/title>\n<meta name=\"description\" content=\"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.syringetest.com\/et\/luer-lock-adaptor-collar-pull-off-force\/\" \/>\n<meta property=\"og:locale\" content=\"et_EE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3\" \/>\n<meta property=\"og:description\" content=\"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.syringetest.com\/et\/luer-lock-adaptor-collar-pull-off-force\/\" \/>\n<meta property=\"og:site_name\" content=\"Syringe and Needle Testing\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-06T03:56:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"515\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force\",\"url\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force\",\"name\":\"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3\",\"isPartOf\":{\"@id\":\"https:\/\/www.syringetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\",\"datePublished\":\"2025-05-06T03:29:29+00:00\",\"dateModified\":\"2025-05-06T03:56:17+00:00\",\"description\":\"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#breadcrumb\"},\"inLanguage\":\"et\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"et\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.syringetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Luer Lock Adaptor Collar Pull-Off Force\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.syringetest.com\/#website\",\"url\":\"https:\/\/www.syringetest.com\/\",\"name\":\"Syringe and Needle Testing\",\"description\":\"Syringe and Needle Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.syringetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.syringetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"et\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.syringetest.com\/#organization\",\"name\":\"Syringe and Needle Testing\",\"url\":\"https:\/\/www.syringetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"et\",\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"width\":512,\"height\":512,\"caption\":\"Syringe and Needle Testing\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3","description":"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.syringetest.com\/et\/luer-lock-adaptor-collar-pull-off-force\/","og_locale":"et_EE","og_type":"article","og_title":"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3","og_description":"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.","og_url":"https:\/\/www.syringetest.com\/et\/luer-lock-adaptor-collar-pull-off-force\/","og_site_name":"Syringe and Needle Testing","article_modified_time":"2025-05-06T03:56:17+00:00","og_image":[{"width":515,"height":350,"url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force","url":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force","name":"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3","isPartOf":{"@id":"https:\/\/www.syringetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage"},"image":{"@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage"},"thumbnailUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp","datePublished":"2025-05-06T03:29:29+00:00","dateModified":"2025-05-06T03:56:17+00:00","description":"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.","breadcrumb":{"@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#breadcrumb"},"inLanguage":"et","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force"]}]},{"@type":"ImageObject","inLanguage":"et","@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.syringetest.com\/"},{"@type":"ListItem","position":2,"name":"Luer Lock Adaptor Collar Pull-Off Force"}]},{"@type":"WebSite","@id":"https:\/\/www.syringetest.com\/#website","url":"https:\/\/www.syringetest.com\/","name":"Syringe and Needle Testing","description":"Syringe and Needle Test Solutions","publisher":{"@id":"https:\/\/www.syringetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.syringetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"et"},{"@type":"Organization","@id":"https:\/\/www.syringetest.com\/#organization","name":"Syringe and Needle Testing","url":"https:\/\/www.syringetest.com\/","logo":{"@type":"ImageObject","inLanguage":"et","@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","width":512,"height":512,"caption":"Syringe and Needle Testing"},"image":{"@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages\/265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/comments?post=265"}],"version-history":[{"count":5,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages\/265\/revisions"}],"predecessor-version":[{"id":275,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages\/265\/revisions\/275"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/media?parent=265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}