{"id":265,"date":"2025-05-06T03:29:29","date_gmt":"2025-05-06T03:29:29","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=265"},"modified":"2026-05-09T06:39:48","modified_gmt":"2026-05-09T06:39:48","slug":"luer-lock-adaptor-collar-pull-off-force","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/et\/luer-lock-adaptor-collar-pull-off-force","title":{"rendered":"Luer Lock adapteri krae v\u00e4ljat\u00f5mbej\u00f5ud"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"265\" class=\"elementor elementor-265\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0ebe6b e-flex e-con-boxed e-con e-parent\" data-id=\"c0ebe6b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d6d91c9 elementor-widget elementor-widget-heading\" data-id=\"d6d91c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Luer Lock adapteri krae v\u00e4ljat\u00f5mbej\u00f5ud<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0a5f59 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"f0a5f59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Farmaatsiat\u00f6\u00f6stuses ja meditsiiniseadmete t\u00f6\u00f6stuses on s\u00fcstla komponentide terviklikkuse tagamine kriitilise t\u00e4htsusega. \u00dcks oluline kvaliteedikontroll on see test. Selle hindamisega m\u00f5\u00f5detakse Luer-lukustusadapteri (LLA) krae ja s\u00fcstlatoru vahelise \u00fchenduse tugevust, mis takistab komponentide eraldumist kasutamise ajal.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7e51b6e e-flex e-con-boxed e-con e-parent\" data-id=\"7e51b6e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a359504 elementor-widget elementor-widget-heading\" data-id=\"a359504\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer Lock adapteri krae v\u00e4ljat\u00f5mbej\u00f5u testimise t\u00e4htsus Luer Locki adapteri krae v\u00e4ljat\u00f5mbej\u00f5u testimine<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de744c7 elementor-widget elementor-widget-text-editor\" data-id=\"de744c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Kui Luer-lukustusadapteri krae t\u00f5mbej\u00f5ud on liiga v\u00e4ike, v\u00f5ib krae k\u00e4sitsemise v\u00f5i s\u00fcstimise ajal s\u00fcstlast lahti tulla, mis v\u00f5ib p\u00f5hjustada ravimi lekke, mittet\u00e4ieliku doseerimise v\u00f5i isegi t\u00f5sise patsiendi vigastuse. Teisest k\u00fcljest, kui j\u00f5ud on liiga suur, v\u00f5ib koosteprotsess muutuda keeruliseks, suurendades kahjustuste ohtu valmistamise ajal.<\/p><p>Seet\u00f5ttu on selle standardiseeritud testimise l\u00e4biviimine kriitilise t\u00e4htsusega, et tagada krae turvaline kinnitamine, s\u00e4ilitada s\u00fcstla t\u00f6\u00f6kindlus ja kaitsta patsiendi ohutust.<\/p><p><strong>Syringetest.com<\/strong> pakub t\u00e4pseid ja usaldusv\u00e4\u00e4rseid katseseadmeid <em>Luer lock adapteri krae t\u00f5mbej\u00f5ud<\/em> hindamised, mis aitavad tagada, et teie s\u00fcstlad vastavad kindlalt \u00fclemaailmsetele kvaliteedistandarditele.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f3ad5f2 e-flex e-con-boxed e-con e-parent\" data-id=\"f3ad5f2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d69bf22 elementor-widget elementor-widget-heading\" data-id=\"d69bf22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 ja ISO 11040-4 lisa G3<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c32614c e-con-full e-flex e-con e-child\" data-id=\"c32614c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fcd1b36 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"fcd1b36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/www.syringetest.com\/et\/standards\/iso-11040-4\/\"><em>ISO 11040-4<\/em><\/a> standard, eriti <em>ISO 11040-4 lisa G3<\/em>, kirjeldab menetlust <em>Luer lock adapteri krae t\u00f5mbej\u00f5ud<\/em> test. Nende standardite kohaselt kontrollitakse t\u00f5mbej\u00f5u testiga, kas krae s\u00fcsteem peab vastu aksiaalsetele j\u00f5ududele, tagades, et s\u00fcstlad j\u00e4\u00e4vad puutumatuks kriitiliste toimingute, n\u00e4iteks ravimite manustamise ajal. Meetodis r\u00f5hutatakse j\u00e4rjekindlaid katsekiirusi, sobivat koormusanduri valikut ja suure sagedusega proovide v\u00f5tmist, et tagada t\u00e4psed ja usaldusv\u00e4\u00e4rsed andmed.<\/p><p>P\u00e4rast <em>ISO 11040-4 lisa G3<\/em> parandab laborite ja tootjate katsete j\u00e4rjepidevust, suurendades usaldust toodete kvaliteedi ja \u00f5igusnormide t\u00e4itmise suhtes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0502b44 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"0502b44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"515\" height=\"350\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" class=\"attachment-medium_large size-medium_large wp-image-272\" alt=\"Luer Lock adapteri krae v\u00e4ljat\u00f5mbej\u00f5ud - ISO 11040-4 lisa G3\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp 515w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing-300x204.webp 300w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c33ea3f e-flex e-con-boxed e-con e-parent\" data-id=\"c33ea3f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b8731e5 elementor-widget elementor-widget-heading\" data-id=\"b8731e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer Lock adapteri krae v\u00e4ljat\u00f5mbej\u00f5u katse p\u00f5him\u00f5te<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-931bcc4 elementor-widget elementor-widget-text-editor\" data-id=\"931bcc4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Selle katse p\u00f5hiidee on lihtne: sellega m\u00f5\u00f5detakse maksimaalset aksiaalset j\u00f5udu, mis on vajalik LLA-kaeluse eemaldamiseks s\u00fcstlatorust. Tugev t\u00f5mbej\u00f5ud t\u00e4hendab, et LLA-kaelus on kindlalt kinnitatud, mis minimeerib kasutamise ajal lahti\u00fchendamise ohtu.<\/p><p>Peamine p\u00f5him\u00f5te keskendub:<\/p><ul><li>Realistliku mehaanilise koormuse simuleerimine.<\/li><li>Tagab, et standardsete Luer-\u00fchenduste sisestusj\u00f5ud ei p\u00f5hjusta krae eemaldumist.<\/li><li>Tippj\u00f5u andmete kogumine j\u00f5u ja nihke anal\u00fc\u00fcsi abil.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cbb1f00 e-flex e-con-boxed e-con e-parent\" data-id=\"cbb1f00\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9e34cbf elementor-widget elementor-widget-heading\" data-id=\"9e34cbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vajalikud seadmed ja materjalid<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29c5058 elementor-widget elementor-widget-text-editor\" data-id=\"29c5058\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>T\u00e4pne testimine <em>Luer lock adapteri krae t\u00f5mbej\u00f5ud<\/em> n\u00f5uab t\u00e4pset varustust:<\/p><ul><li><strong>Universaalne t\u00f5mbe- ja survekatse masin <\/strong>koos:<ul><li>Katsekiiruseks on seatud 20 mm\/min (vastavalt ISO 80369-7, kui see on asjakohane).<\/li><li>Koormusandur, mis sobib 10 N kuni 100 N j\u00f5uvahemiku jaoks.<\/li><\/ul><\/li><li><strong>S\u00fcstalhoidja ja haaratsiseadme hoidja<\/strong> mis kindlustab nii s\u00fcstlatoru kui ka LLA krae ilma soovimatu survet avaldamata.<\/li><\/ul><p><strong>Materjalid:<\/strong><\/p><ul><li>T\u00e4itmiseks valmis steriliseeritud alakomplekteeritud s\u00fcstlad, sealhulgas LLA-s\u00fcsteem.<\/li><\/ul><p><strong>Oluline:<\/strong><br \/>Prooviv\u00f5tusagedus peab olema v\u00e4hemalt 100 Hz \u00fcldkatsete puhul ja 500 Hz tippm\u00f5\u00f5tmiste puhul, et tagada andmete t\u00e4pne eraldusv\u00f5ime ja t\u00e4psus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-61d3079 e-flex e-con-boxed e-con e-parent\" data-id=\"61d3079\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bd94a54 elementor-widget elementor-widget-heading\" data-id=\"bd94a54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer Lock adapteri krae t\u00f5mbej\u00f5u katsemenetlus<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc41e63 elementor-widget elementor-widget-text-editor\" data-id=\"fc41e63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Selle testi korrektne l\u00e4biviimine tagab t\u00e4psed ja korratavad tulemused:<\/p><h3>1. Proovi ettevalmistamine<\/h3><p>Kasutage s\u00fcstlaid, mis on l\u00e4binud t\u00e4ieliku steriliseerimis- ja ettevalmistusprotsessi.<\/p><h3>2. Seadistused<\/h3><ul><li>Eemaldage otsakork ettevaatlikult.<\/li><li>Kinnitage s\u00fcstel vertikaalselt hoidiku (s\u00f5rme\u00e4\u00e4riku) ja haaratsite (LLA krae) vahele, ilma krae pingestamata.<\/li><\/ul><h3>3. Katse l\u00e4biviimine<\/h3><ul><li>Seadke koormusandur nullile, tagades, et eelkoormus puudub.<\/li><li>Rakendage t\u00f5mbej\u00f5udu 20 mm\/min.<\/li><li>Registreerige pidevalt j\u00f5u ja nihke vaheline k\u00f5ver.<\/li><\/ul><h3>4. Testi l\u00f5petamine<\/h3><p>L\u00f5petage katse, kui LLA-kaelus eraldub selgelt s\u00fcstlast.<\/p><h3>5. Tulemuste salvestamine<\/h3><p>Maksimaalne j\u00f5u piik k\u00f5veral kujutab endast <em>t\u00f5mbej\u00f5ud<\/em>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc4abbc e-grid e-con-full e-con e-parent\" data-id=\"dc4abbc\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99d351b elementor-widget elementor-widget-image\" data-id=\"99d351b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ccc877e e-con-full e-flex e-con e-child\" data-id=\"ccc877e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef33af7 elementor-widget elementor-widget-heading\" data-id=\"ef33af7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Miks valida <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b43d751 elementor-widget elementor-widget-text-editor\" data-id=\"b43d751\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"203\" data-end=\"463\">Veebilehel <strong>Syringetest.com<\/strong>, \u00fchendame oma klientide toetamiseks kogu maailmas teadmised, uuendused, t\u00e4pse insener-tehnoloogia ja personaalse teeninduse.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28e0c7c elementor-widget elementor-widget-text-editor\" data-id=\"28e0c7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>T\u00e4itmine <em>Luer lock adapteri krae t\u00f5mbej\u00f5ud<\/em> test vastavalt <em>ISO 11040-4 lisa G3<\/em> on oluline Luer-lukuga s\u00fcstlite mehaanilise turvalisuse tagamiseks. N\u00f5uetekohane t\u00e4itmine ja dokumenteerimine annavad kindluse, et s\u00fcstlad taluvad kliinilise kasutamise pinget ilma t\u00f5rgeteta.<br \/>Tugineda <strong>Syringetest.com<\/strong> tipptasemel testimislahendusi, mis t\u00f5stavad teie s\u00fcstlatoodete kvaliteeti ja ohutust.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5463cac elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"5463cac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/et\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">V\u00f5tke meiega \u00fchendust<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Adaptor Collar Pull-Off Force In the pharmaceutical and medical device industries, ensuring the integrity of syringe components is critical. One essential quality check is the this test. This evaluation measures the strength of the connection between the Luer lock adaptor (LLA) collar and the syringe barrel, preventing component separation during use. The Importance [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-265","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages\/265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/comments?post=265"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages\/265\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/media?parent=265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}