{"id":247,"date":"2025-05-06T02:59:16","date_gmt":"2025-05-06T02:59:16","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=247"},"modified":"2026-05-14T08:15:29","modified_gmt":"2026-05-14T08:15:29","slug":"needle-tubing-stiffness-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/et\/needle-tubing-stiffness-test","title":{"rendered":"N\u00f5elatoru j\u00e4ikuse test"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"247\" class=\"elementor elementor-247\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1e601d7 e-flex e-con-boxed e-con e-parent\" data-id=\"1e601d7\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0e5a4e8 elementor-widget elementor-widget-heading\" data-id=\"0e5a4e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">N\u00f5elatoru j\u00e4ikuse test<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-307f5d3 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"307f5d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <strong>n\u00f5elatoru j\u00e4ikuse katse<\/strong> m\u00e4ngib kriitilist rolli meditsiiniseadmete, eelk\u00f5ige s\u00fcstlan\u00f5elte toimivuse ja ohutuse tagamisel. Selle katsega m\u00e4\u00e4ratakse kindlaks roostevabast terasest torude vastupidavus paindumisele, kui neile rakendatakse standardiseeritud j\u00f5udu. Meditsiiniseadmete t\u00f6\u00f6stuse spetsialistidele - eriti neile, kes tegelevad s\u00fcstlate kvaliteedi tagamisega - on selle katse m\u00f5istmine oluline regulatiivsete standardite t\u00e4itmiseks ja patsientide ohutuse tagamiseks.<\/p><p>Syringetest.com pakub \u00fclit\u00e4pseid lahendusi n\u00f5elatorude j\u00e4ikuse testide l\u00e4biviimiseks, tagades, et teie tooted vastavad \u00fclemaailmsetele standarditele, nagu nt. <strong>ISO 9626<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5684a6e e-flex e-con-boxed e-con e-parent\" data-id=\"5684a6e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-02d54a2 elementor-widget elementor-widget-heading\" data-id=\"02d54a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 9626 ja ISO 9626 B lisa<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b9bcb4 e-con-full e-flex e-con e-child\" data-id=\"1b9bcb4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c55fa1a elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"c55fa1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.syringetest.com\/et\/standards\/iso-9626\/\"><strong>ISO 9626<\/strong><\/a>, pealkirjaga <em>Roostevabast terasest n\u00f5elatorud meditsiiniseadmete valmistamiseks - N\u00f5uded ja katsemeetodid<\/em>, s\u00e4testatakse meditsiiniseadmetes kasutatavate roostevabast terasest torude f\u00fc\u00fcsikalised ja mehaanilised kriteeriumid. Selle p\u00f5hikomponentide hulgas, <strong>ISO 9626 B lisa<\/strong> annab \u00fcksikasjaliku meetodi, kuidas teostada <strong>n\u00f5elatoru j\u00e4ikuse katse<\/strong>, pakkudes rangeid menetlusn\u00f5udeid ja seadmete spetsifikatsioone.<\/p><p>B lisas on kirjeldatud, kuidas hinnata j\u00e4ikust, kohaldades <strong>kindlaksm\u00e4\u00e4ratud j\u00f5ud<\/strong> torude keskele, mis on m\u00f5lemast otsast toetatud ja m\u00f5\u00f5tes <strong>saadud k\u00f5rvalekalle<\/strong>. See protsess aitab hinnata, kas torud vastavad mehaanilisele tugevusele, mis on vajalik, et nad suudaksid reaalses kasutuses paindumata v\u00f5i rikkumata vastu pidada.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25a7788 elementor-widget elementor-widget-image\" data-id=\"25a7788\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"590\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard.webp\" class=\"attachment-large size-large wp-image-99\" alt=\"lahtirebimise ja libisemisj\u00f5u testimise standard\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard-300x295.webp 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd39b91 e-con-full e-flex e-con e-child\" data-id=\"fd39b91\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-315872e elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"315872e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Katse p\u00f5him\u00f5te ja olulisus<\/h3><p>P\u00f5hiprintsiip on <strong>n\u00f5elatoru j\u00e4ikuse katse<\/strong> on lihtne: m\u00f5lemast otsast horisontaalselt toetatud n\u00f5elatoru keskele rakendatakse fikseeritud allapoole suunatud j\u00f5udu. Veebileht <strong>l\u00e4bipainde suurus<\/strong> j\u00f5u rakendamise kohas n\u00e4itab toru j\u00e4ikust.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0b91159 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"0b91159\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Miks on see oluline?<\/h3><ul><li><strong>Toote ohutus:<\/strong> V\u00e4ltige s\u00fcstimise ajal painutamist v\u00f5i purunemist.<\/li><li><strong>Tootmise j\u00e4rjepidevus:<\/strong> Veenduge, et iga partii vastab samadele mehaanilistele standarditele.<\/li><li><strong>\u00d5igusaktide j\u00e4rgimine:<\/strong> Tutvu <strong>ISO 9626<\/strong> sertifitseerimine \u00fclemaailmsele turule sisenemiseks.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2176b2b e-flex e-con-boxed e-con e-parent\" data-id=\"2176b2b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0601f88 elementor-widget elementor-widget-heading\" data-id=\"0601f88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">N\u00f5elatoru j\u00e4ikuse testimiseks vajalik varustus<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91dcc43 elementor-widget elementor-widget-text-editor\" data-id=\"91dcc43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Katse l\u00e4biviimiseks vastavalt <strong>ISO 9626 B lisa<\/strong>, on vaja j\u00e4rgmist seadet:<\/p><h3>J\u00e4ikuse katseseadmed<\/h3><p class=\"\" data-start=\"2125\" data-end=\"2247\">V\u00f5imaldab kohaldada kuni <strong>60 N<\/strong> j\u00f5u t\u00e4psusega <strong>\u00b10.1 N<\/strong>, kus on <strong>t\u00fcmpsunud kiilukujuline kolb<\/strong>. Kiil peab koosnema kahest tasasest pinnast, mis on kallutatud aadressil <strong>60\u00b0<\/strong>, mida l\u00f5ikab silindriline pind, millel on <strong>1 mm raadius<\/strong>.<\/p><h3 data-start=\"2125\" data-end=\"2247\">K\u00f5rvalekalde m\u00f5\u00f5tmise seade<\/h3><p class=\"\" data-start=\"2755\" data-end=\"3082\">T\u00e4pne kuni <strong>0,01 mm<\/strong>, mida kasutatakse selleks, et registreerida, kui palju torud painduvad rakendatud j\u00f5u m\u00f5jul.<\/p><p>Syringetest.com pakub kohandatavaid testimisvahendeid, mis vastavad t\u00e4ielikult nendele tehnilistele n\u00f5uetele, aidates laboritel ja tootjatel rakendada standardiseeritud ja korratavaid testimisprotsesse.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-512b05c e-flex e-con-boxed e-con e-parent\" data-id=\"512b05c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-820f2d6 elementor-widget elementor-widget-heading\" data-id=\"820f2d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">N\u00f5eltorude j\u00e4ikuse katse protseduur<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9839f71 elementor-widget elementor-widget-text-editor\" data-id=\"9839f71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>1. Proovi paigutamine<\/h3><p>Asetage toru katseseadmele. Veenduge:<\/p><ul><li>The <strong>span<\/strong> vastab ISO 9626 tabelis 2 loetletud v\u00e4\u00e4rtustele antud torustiku suuruse puhul.<\/li><li>The <strong>Plunger<\/strong> on tsentreeritud.<\/li><li>Torud on orienteeritud <strong>risti<\/strong> nii kolvi kui ka tugipunktide suhtes.<\/li><\/ul><h3>2. J\u00f5u rakendamine<\/h3><p>Rakendage allapoole suunatud j\u00f5udu, nagu on ette n\u00e4htud torude suuruse jaoks, kontrollitud kiirusega <strong>1 mm\/min kuni 10 mm\/min<\/strong>.<\/p><h3>3. L\u00e4bipainde m\u00f5\u00f5tmine<\/h3><p>M\u00f5\u00f5tke ja registreerige <strong>k\u00f5rvalekaldumine<\/strong> torude keskpunktis t\u00e4psusega <strong>\u00b10,01 mm<\/strong>.<\/p><h3>4. Tulemuste esitamine<\/h3><p>T\u00e4ielik katsearuanne peab sisaldama:<\/p><ul><li>Torude suurus ja identifitseerimine<\/li><li>Torut\u00fc\u00fcp (RW, TW, ETW, UTW)<\/li><li>M\u00f5\u00f5detud k\u00f5rvalekalle<\/li><li>Testimise kuup\u00e4ev<\/li><li>Kasutatav roostevabast terasest sulam<\/li><\/ul><p>Syringetest.com'i automaatsed j\u00e4ikuse testijad lihtsustavad seda protsessi, integreerides <strong>t\u00e4psusandurid<\/strong> ja <strong>kasutajas\u00f5bralikud kasutajaliidesed<\/strong> tagada katsetulemuste korratavus ja j\u00e4lgitavus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b7a8cd e-grid e-con-full e-con e-parent\" data-id=\"7b7a8cd\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ce47441 elementor-widget elementor-widget-image\" data-id=\"ce47441\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-413684e e-con-full e-flex e-con e-child\" data-id=\"413684e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5ae9222 elementor-widget elementor-widget-heading\" data-id=\"5ae9222\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Miks valida <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ee84ad elementor-widget elementor-widget-text-editor\" data-id=\"8ee84ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Usaldusv\u00e4\u00e4rse materjalikontrolli lahenduste pakkujana, <strong>Syringetest.com<\/strong> tarnib ISO standarditele vastavaid ja neid \u00fcletavaid seadmeid. Meie j\u00e4ikuskatseseadmed on konstrueeritud j\u00e4rgmisteks eesm\u00e4rkideks:<\/p><ul><li><strong>K\u00f5rge t\u00e4psus ja usaldusv\u00e4\u00e4rsus<\/strong><\/li><li><strong>Kasutaja kohandamine<\/strong> spetsiaalsete torude suuruste v\u00f5i sulamit\u00fc\u00fcpide puhul<\/li><li><strong>Automatiseerimise v\u00f5imalused<\/strong> testimise t\u00f5hususe suurendamiseks<\/li><li><strong>Andmete registreerimine ja j\u00e4lgitavus<\/strong> auditivalmiduse tagamiseks<\/li><\/ul><p>Me teenindame t\u00f6\u00f6stusharusid alates <strong>meditsiiniseadmed ja ravimid kvaliteedikontrolli laboritele<\/strong>. Keskendudes tugevalt innovatsioonile, toetame ka <strong>automaatika uuendamine<\/strong> ja <strong>kohandatud testide v\u00e4ljat\u00f6\u00f6tamine<\/strong>.<\/p><p>The <strong>n\u00f5elatoru j\u00e4ikuse katse<\/strong>, kui see toimub n\u00f5uetekohaselt <strong>ISO 9626 B lisa<\/strong>, tagab, et meditsiinilised torud s\u00e4ilitavad kasutamise ajal mehaanilise terviklikkuse. K\u00fcsimus ei ole ainult vastavuses - see on seotud <strong>patsientide kaitsmine ja usalduse s\u00e4ilitamine<\/strong> meditsiinitoodete puhul.<\/p><p>Professionaalsete testimisvahenditega alates <strong>Syringetest.com<\/strong>, saavad tootjad kindlalt tagada toote kvaliteedi, t\u00e4ita rahvusvahelisi standardeid ja t\u00f5hustada kvaliteedikontrolliprotsesse.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-383dde0 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"383dde0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/et\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">V\u00f5tke meiega \u00fchendust<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Needle Tubing Stiffness Test The needle tubing stiffness test plays a critical role in ensuring the performance and safety of medical devices, particularly hypodermic needles. This test determines the resistance of stainless steel tubing to bending when a standardized force is applied. For professionals in the medical device industry\u2014especially those involved in quality assurance of [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-247","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages\/247","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/comments?post=247"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/pages\/247\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/et\/wp-json\/wp\/v2\/media?parent=247"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}