{"id":265,"date":"2025-05-06T03:29:29","date_gmt":"2025-05-06T03:29:29","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=265"},"modified":"2025-05-06T03:56:17","modified_gmt":"2025-05-06T03:56:17","slug":"luer-lock-adaptor-collar-pull-off-force","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/es\/luer-lock-adaptor-collar-pull-off-force","title":{"rendered":"Fuerza de extracci\u00f3n del collar adaptador Luer Lock"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"265\" class=\"elementor elementor-265\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-292be0b e-flex e-con-boxed e-con e-parent\" data-id=\"292be0b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0f48abd elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"0f48abd\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fuerza de extracci\u00f3n del collar adaptador Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6817f29 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"6817f29\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>En las industrias farmac\u00e9utica y de dispositivos m\u00e9dicos, es fundamental garantizar la integridad de los componentes de las jeringuillas. Una comprobaci\u00f3n de calidad esencial es esta prueba. Esta evaluaci\u00f3n mide la resistencia de la conexi\u00f3n entre el collar\u00edn del adaptador de cierre Luer (LLA) y la jeringa, evitando la separaci\u00f3n de los componentes durante el uso.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad68bc6 e-flex e-con-boxed e-con e-parent\" data-id=\"ad68bc6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ecf369e elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ecf369e\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">La importancia de las pruebas de fuerza de extracci\u00f3n del collar adaptador Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f390758 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"f390758\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Si la fuerza de extracci\u00f3n del collar\u00edn adaptador con cierre Luer es demasiado baja, el collar\u00edn puede desprenderse de la jeringa durante la manipulaci\u00f3n o la inyecci\u00f3n, lo que puede provocar fugas de medicaci\u00f3n, una dosificaci\u00f3n incompleta o incluso lesiones graves al paciente. Por otra parte, si la fuerza es demasiado alta, los procesos de montaje pueden resultar dif\u00edciles, aumentando el riesgo de da\u00f1os durante la fabricaci\u00f3n.<\/p><p>Por lo tanto, la realizaci\u00f3n de estas pruebas estandarizadas es fundamental para garantizar la fijaci\u00f3n segura del collar\u00edn, mantener la fiabilidad funcional de la jeringa y proteger la seguridad del paciente.<\/p><p><strong>Syringetest.com<\/strong> ofrece equipos de ensayo precisos y fiables para <em>Fuerza de extracci\u00f3n del collar adaptador Luer Lock<\/em> para garantizar que sus jeringuillas cumplen las normas de calidad internacionales con total confianza.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4835ce e-flex e-con-boxed e-con e-parent\" data-id=\"d4835ce\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea29382 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ea29382\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 e ISO 11040-4 Anexo G3<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-55047da e-con-full e-flex e-con e-child\" data-id=\"55047da\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-ae8face e-con-full e-flex e-con e-child\" data-id=\"ae8face\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-42248e5 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"42248e5\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInLeft&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>En <a href=\"https:\/\/www.syringetest.com\/es\/standards\/iso-11040-4\/\"><em>ISO 11040-4<\/em><\/a> norma, en particular <em>ISO 11040-4 Anexo G3<\/em>El procedimiento <em>Fuerza de extracci\u00f3n del collar adaptador Luer Lock<\/em> prueba. Seg\u00fan estas normas, la prueba de fuerza de extracci\u00f3n verifica la capacidad del sistema de collar\u00edn para soportar fuerzas axiales, garantizando que las jeringuillas permanezcan intactas durante operaciones cr\u00edticas como la administraci\u00f3n de medicaci\u00f3n. El m\u00e9todo hace hincapi\u00e9 en las velocidades de ensayo coherentes, la selecci\u00f3n adecuada de la c\u00e9lula de carga y el muestreo de alta frecuencia para garantizar datos precisos y fiables.<\/p><p>Despu\u00e9s de <em>ISO 11040-4 Anexo G3<\/em> mejora la coherencia de las pruebas entre laboratorios y fabricantes, fomentando la confianza en la calidad de los productos y el cumplimiento de la normativa.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fda7334 e-con-full e-flex e-con e-child\" data-id=\"fda7334\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a601c24 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-image\" data-id=\"a601c24\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInRight&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"515\" height=\"350\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" class=\"attachment-large size-large wp-image-272\" alt=\"Fuerza de extracci\u00f3n del collar adaptador Luer Lock - ISO 11040-4 Anexo G3\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp 515w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing-300x204.webp 300w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-41ab1d6 e-flex e-con-boxed e-con e-parent\" data-id=\"41ab1d6\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-48c60fb elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"48c60fb\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Principio de la prueba de fuerza de extracci\u00f3n del collar adaptador Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c5b3e59 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"c5b3e59\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La idea central de esta prueba es sencilla: mide la fuerza axial m\u00e1xima necesaria para separar el collar LLA de la jeringa. Una fuerza de extracci\u00f3n fuerte significa que el collar LLA est\u00e1 bien sujeto, lo que minimiza el riesgo de desconexi\u00f3n durante el uso.<\/p><p>El principio clave se centra en:<\/p><ul><li>Simulaci\u00f3n de tensiones mec\u00e1nicas realistas.<\/li><li>Garantiza que las fuerzas de inserci\u00f3n de los conectores Luer est\u00e1ndar no provoquen el desprendimiento del collar\u00edn.<\/li><li>Recogida de datos de fuerza m\u00e1xima mediante an\u00e1lisis de fuerza frente a desplazamiento.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad468be e-flex e-con-boxed e-con e-parent\" data-id=\"ad468be\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-edb7717 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"edb7717\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Aparatos y materiales necesarios<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5810d33 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"5810d33\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pruebas precisas de <em>Fuerza de extracci\u00f3n del collar adaptador Luer Lock<\/em> exige equipos de precisi\u00f3n:<\/p><ul><li><strong>M\u00e1quina universal de ensayos de tracci\u00f3n y compresi\u00f3n <\/strong>con:<ul><li>Velocidad de ensayo fijada en 20 mm\/min (seg\u00fan ISO 80369-7, si procede).<\/li><li>C\u00e9lula de carga adecuada para un rango de fuerza de 10 N a 100 N.<\/li><\/ul><\/li><li><strong>Soporte para jeringuillas y dispositivo de agarre<\/strong> que asegura tanto la jeringa como el collar LLA sin aplicar una presi\u00f3n no deseada.<\/li><\/ul><p><strong>Materiales:<\/strong><\/p><ul><li>Jeringas subensambladas esterilizadas listas para el llenado, incluido el sistema LLA.<\/li><\/ul><p><strong>Importante:<\/strong><br \/>La frecuencia de muestreo no debe ser inferior a 100 Hz para las pruebas generales y a 500 Hz para las mediciones de picos, lo que garantiza una gran resoluci\u00f3n y precisi\u00f3n de los datos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-285667c e-con-full e-flex e-con e-parent\" data-id=\"285667c\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f7c629 elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"3f7c629\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procedimiento de prueba de fuerza de extracci\u00f3n del collar adaptador Luer Lock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f6e7fda elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"f6e7fda\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La realizaci\u00f3n correcta de esta prueba garantiza resultados precisos y repetibles:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d737d1 e-n-tabs-mobile elementor-invisible elementor-widget elementor-widget-n-tabs\" data-id=\"9d737d1\" data-element_type=\"widget\" data-settings=\"{&quot;tabs_justify_horizontal&quot;:&quot;center&quot;,&quot;_animation&quot;:&quot;fadeInUp&quot;,&quot;horizontal_scroll&quot;:&quot;disable&quot;}\" data-widget_type=\"nested-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-tabs\" data-widget-number=\"165099473\" aria-label=\"Registerkarten. \u00d6ffnen Sie Elemente mit Enter oder Space, schlie\u00dfen Sie sie mit Escape und navigieren Sie mit den Pfeiltasten.\" data-no-translation-aria-label=\"\">\n\t\t\t<div class=\"e-n-tabs-heading\" role=\"tablist\">\n\t\t\t\t\t<button id=\"e-n-tab-title-1650994731\" class=\"e-n-tab-title\" aria-selected=\"true\" data-tab-index=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"e-n-tab-content-1650994731\" style=\"--n-tabs-title-order: 1;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t1. Preparaci\u00f3n de la muestra\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1650994732\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1650994732\" style=\"--n-tabs-title-order: 2;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t2. Configure\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1650994733\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1650994733\" style=\"--n-tabs-title-order: 3;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t3. Ejecuci\u00f3n de la prueba\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1650994734\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1650994734\" style=\"--n-tabs-title-order: 4;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t4. Finalizaci\u00f3n de la prueba\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1650994735\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"5\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1650994735\" style=\"--n-tabs-title-order: 5;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\t5. Registro de resultados\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t\t<\/div>\n\t\t\t<div class=\"e-n-tabs-content\">\n\t\t\t\t<div id=\"e-n-tab-content-1650994731\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994731\" data-tab-index=\"1\" style=\"--n-tabs-title-order: 1;\" class=\"e-active elementor-element elementor-element-e75ed08 e-flex e-con-boxed e-con e-child\" data-id=\"e75ed08\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f3434b1 elementor-widget elementor-widget-text-editor\" data-id=\"f3434b1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utilice jeringuillas que hayan sido sometidas a un proceso completo de esterilizaci\u00f3n y preparaci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1650994732\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994732\" data-tab-index=\"2\" style=\"--n-tabs-title-order: 2;\" class=\"elementor-element elementor-element-f886d7d e-flex e-con-boxed e-con e-child\" data-id=\"f886d7d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f5549bf elementor-widget elementor-widget-text-editor\" data-id=\"f5549bf\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Retire el tap\u00f3n de la punta con cuidado.<\/li><li>Fije la jeringa verticalmente entre el soporte (brida de dedos) y la pinza (collar LLA) sin tensar el collar.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1650994733\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994733\" data-tab-index=\"3\" style=\"--n-tabs-title-order: 3;\" class=\"elementor-element elementor-element-8a12e10 e-flex e-con-boxed e-con e-child\" data-id=\"8a12e10\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3c766c8 elementor-widget elementor-widget-text-editor\" data-id=\"3c766c8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Ponga la c\u00e9lula de carga a cero, asegur\u00e1ndose de que no haya precarga.<\/li><li>Aplique una fuerza de tracci\u00f3n de 20 mm\/min.<\/li><li>Registre continuamente la curva de fuerza en funci\u00f3n del desplazamiento.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1650994734\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994734\" data-tab-index=\"4\" style=\"--n-tabs-title-order: 4;\" class=\"elementor-element elementor-element-b3f1f40 e-flex e-con-boxed e-con e-child\" data-id=\"b3f1f40\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-904eb23 elementor-widget elementor-widget-text-editor\" data-id=\"904eb23\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Detenga la prueba cuando el collar LLA se separe claramente de la jeringa.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1650994735\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1650994735\" data-tab-index=\"5\" style=\"--n-tabs-title-order: 5;\" class=\"elementor-element elementor-element-af75195 e-flex e-con-boxed e-con e-child\" data-id=\"af75195\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f9a6a49 elementor-widget elementor-widget-text-editor\" data-id=\"f9a6a49\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El pico de fuerza m\u00e1xima en la curva representa el <em>fuerza de extracci\u00f3n<\/em>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b581cc e-con-full e-flex e-con e-parent\" data-id=\"1b581cc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-61afd37 e-grid e-con-full e-con e-child\" data-id=\"61afd37\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-f8ace73 e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"f8ace73\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94cc5ad e-flex e-con-boxed elementor-invisible e-con e-child\" data-id=\"94cc5ad\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInRight&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-907b713 elementor-widget elementor-widget-heading\" data-id=\"907b713\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Por qu\u00e9 elegir <b>\u00bfSyringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-718f32f elementor-widget elementor-widget-text-editor\" data-id=\"718f32f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Realizaci\u00f3n de la <em>Fuerza de extracci\u00f3n del collar adaptador Luer Lock<\/em> prueba seg\u00fan <em>ISO 11040-4 Anexo G3<\/em> es vital para garantizar la seguridad mec\u00e1nica de las jeringuillas con cierre Luer. Una ejecuci\u00f3n y documentaci\u00f3n adecuadas garantizan que las jeringuillas puedan soportar las tensiones del uso cl\u00ednico sin fallos.<br \/>Conf\u00ede en <strong>Syringetest.com<\/strong> para obtener soluciones de ensayo de vanguardia que eleven la calidad y la seguridad de sus productos de jeringuilla.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f735b94 elementor-widget elementor-widget-eael-creative-button\" data-id=\"f735b94\" data-element_type=\"widget\" data-widget_type=\"eael-creative-button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-creative-button-wrapper\">\n\n            <a class=\"eael-creative-button eael-creative-button--default\" href=\"#\" data-text=\"Contact Us\">\n\n\t    \n                <div class=\"creative-button-inner\">\n\n                    \n                    <span class=\"cretive-button-text\">Contacte con nosotros<\/span>\n\n                                    <\/div>\n\t                        <\/a>\n        <\/div>\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Adaptor Collar Pull-Off Force In the pharmaceutical and medical device industries, ensuring the integrity of syringe components is critical. One essential quality check is the this test. This evaluation measures the strength of the connection between the Luer lock adaptor (LLA) collar and the syringe barrel, preventing component separation during use. The Importance [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-265","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3<\/title>\n<meta name=\"description\" content=\"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.syringetest.com\/es\/luer-lock-adaptor-collar-pull-off-force\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3\" \/>\n<meta property=\"og:description\" content=\"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.syringetest.com\/es\/luer-lock-adaptor-collar-pull-off-force\/\" \/>\n<meta property=\"og:site_name\" content=\"Syringe and Needle Testing\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-06T03:56:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"515\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force\",\"url\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force\",\"name\":\"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3\",\"isPartOf\":{\"@id\":\"https:\/\/www.syringetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\",\"datePublished\":\"2025-05-06T03:29:29+00:00\",\"dateModified\":\"2025-05-06T03:56:17+00:00\",\"description\":\"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.syringetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Luer Lock Adaptor Collar Pull-Off Force\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.syringetest.com\/#website\",\"url\":\"https:\/\/www.syringetest.com\/\",\"name\":\"Syringe and Needle Testing\",\"description\":\"Syringe and Needle Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.syringetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.syringetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.syringetest.com\/#organization\",\"name\":\"Syringe and Needle Testing\",\"url\":\"https:\/\/www.syringetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"width\":512,\"height\":512,\"caption\":\"Syringe and Needle Testing\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3","description":"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.syringetest.com\/es\/luer-lock-adaptor-collar-pull-off-force\/","og_locale":"es_ES","og_type":"article","og_title":"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3","og_description":"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.","og_url":"https:\/\/www.syringetest.com\/es\/luer-lock-adaptor-collar-pull-off-force\/","og_site_name":"Syringe and Needle Testing","article_modified_time":"2025-05-06T03:56:17+00:00","og_image":[{"width":515,"height":350,"url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force","url":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force","name":"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3","isPartOf":{"@id":"https:\/\/www.syringetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage"},"image":{"@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage"},"thumbnailUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp","datePublished":"2025-05-06T03:29:29+00:00","dateModified":"2025-05-06T03:56:17+00:00","description":"How to conduct a Luer lock adaptor collar pull-off force test according to ISO 11040-4 Annex G3 and ensure syringe quality with precision.","breadcrumb":{"@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#primaryimage","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-pull-off-force#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.syringetest.com\/"},{"@type":"ListItem","position":2,"name":"Luer Lock Adaptor Collar Pull-Off Force"}]},{"@type":"WebSite","@id":"https:\/\/www.syringetest.com\/#website","url":"https:\/\/www.syringetest.com\/","name":"Syringe and Needle Testing","description":"Syringe and Needle Test Solutions","publisher":{"@id":"https:\/\/www.syringetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.syringetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.syringetest.com\/#organization","name":"Syringe and Needle Testing","url":"https:\/\/www.syringetest.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","width":512,"height":512,"caption":"Syringe and Needle Testing"},"image":{"@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/es\/wp-json\/wp\/v2\/pages\/265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/es\/wp-json\/wp\/v2\/comments?post=265"}],"version-history":[{"count":5,"href":"https:\/\/www.syringetest.com\/es\/wp-json\/wp\/v2\/pages\/265\/revisions"}],"predecessor-version":[{"id":275,"href":"https:\/\/www.syringetest.com\/es\/wp-json\/wp\/v2\/pages\/265\/revisions\/275"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/es\/wp-json\/wp\/v2\/media?parent=265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}