{"id":878,"date":"2026-05-08T04:11:57","date_gmt":"2026-05-08T04:11:57","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=878"},"modified":"2026-05-19T07:20:57","modified_gmt":"2026-05-19T07:20:57","slug":"iso-8537","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/de\/standards\/iso-8537","title":{"rendered":"ISO 8537"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"878\" class=\"elementor elementor-878\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-48d9594 e-flex e-con-boxed e-con e-parent\" data-id=\"48d9594\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-85f9391 elementor-widget elementor-widget-heading\" data-id=\"85f9391\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 8537<br><small>Sterile Einmalspritzen, mit oder ohne Nadel, f\u00fcr Insulin<\/small><\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aac7d95 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"aac7d95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"356\" data-end=\"891\">Sterile Insulinspritzen m\u00fcssen pr\u00e4zise funktionieren, um die Sicherheit der Patienten, eine genaue Dosierung und eine zuverl\u00e4ssige Medikamentenabgabe zu gew\u00e4hrleisten. <strong data-start=\"491\" data-end=\"503\">ISO 8537<\/strong> spezifiziert die Anforderungen und entsprechenden Pr\u00fcfverfahren f\u00fcr sterile Einmalspritzen mit oder ohne Nadeln, die f\u00fcr die Insulininjektion bestimmt sind. Die Norm konzentriert sich auf kritische Merkmale wie Leckagefestigkeit, Kolbenbet\u00e4tigungskraft, Totraum und Unversehrtheit der Verbindung zwischen den Spritzenkomponenten einschlie\u00dflich der <strong data-start=\"831\" data-end=\"890\">D\u00fcse, Nabe, Nadel, Zylinder, Kolben und Gummistopfen<\/strong>.<\/p><p data-start=\"893\" data-end=\"1221\">F\u00fcr Spritzenhersteller und Qualit\u00e4tskontrolllabors ist die Einhaltung der <strong data-start=\"969\" data-end=\"981\">ISO 8537<\/strong> hilft bei der \u00dcberpr\u00fcfung der Produktkonsistenz, der Verringerung des Risikos von Leckagen und der Verbesserung der Injektionsleistung w\u00e4hrend der klinischen Anwendung. Moderne Pr\u00fcfsysteme unterst\u00fctzen auch die automatische Datenerfassung, die Wiederholbarkeitsanalyse und die r\u00fcckverfolgbare Qualit\u00e4tsdokumentation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-34af957 e-flex e-con-boxed e-con e-parent\" data-id=\"34af957\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dc7d0ed elementor-widget elementor-widget-heading\" data-id=\"dc7d0ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 8537 Anforderungen an die Leistungspr\u00fcfung von Spritzen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-413ec4f elementor-widget elementor-widget-text-editor\" data-id=\"413ec4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1286\" data-end=\"1440\">ISO 8537 legt mehrere Pr\u00fcfverfahren zur Bewertung der mechanischen und dichtenden Eigenschaften von sterilen Insulinspritzen fest. Die Norm umfasst:<\/p><ul data-start=\"1442\" data-end=\"1681\"><li data-section-id=\"1lghe2x\" data-start=\"1442\" data-end=\"1478\">Leistung der Spritzenkolbendichtung<\/li><li data-section-id=\"km50lt\" data-start=\"1479\" data-end=\"1503\">Widerstand gegen Luftleckagen<\/li><li data-section-id=\"413t8n\" data-start=\"1504\" data-end=\"1531\">Widerstand gegen Fl\u00fcssigkeitsaustritt<\/li><li data-section-id=\"vzeopp\" data-start=\"1532\" data-end=\"1558\">Bestimmung des Totraums<\/li><li data-section-id=\"87u2zy\" data-start=\"1559\" data-end=\"1596\">Losbrech- und Gleitkraftpr\u00fcfung<\/li><li data-section-id=\"1r4pkcu\" data-start=\"1597\" data-end=\"1634\">Integrit\u00e4t der Nadel- und Nabenverbindung<\/li><li data-section-id=\"1cxbo49\" data-start=\"1635\" data-end=\"1681\">Spritzenf\u00e4higkeit und Injektionsf\u00e4higkeit<\/li><\/ul><p data-start=\"1683\" data-end=\"1855\">Diese Bewertungen stellen sicher, dass die Spritze w\u00e4hrend des Ansaugens und der Injektion ihre Dichtungsf\u00e4higkeit beibeh\u00e4lt und gleichzeitig eine reibungslose Kolbenbewegung und eine genaue Dosierung gew\u00e4hrleistet.<\/p><p data-start=\"1857\" data-end=\"1907\">F\u00fcr die Hersteller haben diese Tests einen direkten Einfluss:<\/p><ul data-start=\"1909\" data-end=\"2019\"><li data-section-id=\"1kgf4fz\" data-start=\"1909\" data-end=\"1925\">Produktsicherheit<\/li><li data-section-id=\"fw7gsx\" data-start=\"1926\" data-end=\"1945\">Komfort der Injektion<\/li><li data-section-id=\"4fq85f\" data-start=\"1946\" data-end=\"1962\">Pr\u00e4zision der Dosis<\/li><li data-section-id=\"1yh82kt\" data-start=\"1963\" data-end=\"1986\">Einhaltung von Vorschriften<\/li><li data-section-id=\"1lk2gtk\" data-start=\"1987\" data-end=\"2019\">Konsistenz der Produktionsqualit\u00e4t<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-38a36c9 e-flex e-con-boxed e-con e-parent\" data-id=\"38a36c9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ba9a815 elementor-widget elementor-widget-heading\" data-id=\"ba9a815\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pr\u00fcfung der Spritzenf\u00e4higkeit und Injektionsf\u00e4higkeit nach ISO 8537<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-89fad34 e-con-full e-flex e-con e-child\" data-id=\"89fad34\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a2a949 elementor-widget elementor-widget-text-editor\" data-id=\"3a2a949\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2090\" data-end=\"2310\">Die <strong data-start=\"2094\" data-end=\"2135\">Pr\u00fcfung der Spritzenf\u00e4higkeit und Injektionsf\u00e4higkeit<\/strong> bewertet die Betriebseigenschaften des Spritzenkolbens w\u00e4hrend der Fl\u00fcssigkeitsabgabe. Anhang C der ISO 8537 definiert die Bestimmung der f\u00fcr die Bet\u00e4tigung des Kolbens erforderlichen Kr\u00e4fte.<\/p><p data-start=\"2312\" data-end=\"2333\">W\u00e4hrend des Eingriffs:<\/p><ol data-start=\"2335\" data-end=\"2663\"><li data-section-id=\"200s8h\" data-start=\"2335\" data-end=\"2408\">Die Spritze wird bis zum Nennvolumen von 50% mit destilliertem Wasser gef\u00fcllt.<\/li><li data-section-id=\"mdao9q\" data-start=\"2409\" data-end=\"2478\">Die Spritze wird senkrecht mit der Nadel nach unten gerichtet befestigt.<\/li><li data-section-id=\"l6yed3\" data-start=\"2479\" data-end=\"2533\">Eine kontrollierte axiale Kraft wird auf den Kolben ausge\u00fcbt.<\/li><li data-section-id=\"16cx4j2\" data-start=\"2534\" data-end=\"2596\">Die zur Ausl\u00f6sung der Kolbenbewegung erforderliche Kraft wird aufgezeichnet.<\/li><li data-section-id=\"7rurb5\" data-start=\"2597\" data-end=\"2663\">Die zur Aufrechterhaltung der Bewegung erforderliche Dauerkraft wird ebenfalls gemessen.<\/li><\/ol><p data-start=\"2665\" data-end=\"2714\">Bei diesem Verfahren werden zwei wichtige Parameter ermittelt:<\/p><ul data-start=\"2716\" data-end=\"2866\"><li data-section-id=\"fbhnrm\" data-start=\"2716\" data-end=\"2791\"><strong data-start=\"2718\" data-end=\"2739\">Losbrechkraft<\/strong> - die Anfangskraft, die erforderlich ist, um die Kolbenbewegung in Gang zu setzen<\/li><li data-section-id=\"1wcea99\" data-start=\"2792\" data-end=\"2866\"><strong data-start=\"2794\" data-end=\"2809\">Gleitkraft<\/strong> - die kontinuierliche Kraft, die zur Aufrechterhaltung des Kolbenwegs erforderlich ist<\/li><\/ul><p data-start=\"2868\" data-end=\"3028\">Eine zu hohe Losbrechkraft kann zu einem unangenehmen Injektionsvorgang f\u00fchren, w\u00e4hrend eine instabile Gleitkraft die Injektionssteuerung und die Dosiergenauigkeit negativ beeinflussen kann.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9edb986 elementor-widget elementor-widget-image\" data-id=\"9edb986\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"982\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-834x1024.webp\" class=\"attachment-large size-large wp-image-891\" alt=\"ISO 8537 Anhang C\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-834x1024.webp 834w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-244x300.webp 244w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-768x943.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-1251x1536.webp 1251w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-1668x2048.webp 1668w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C-10x12.webp 10w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-C.webp 1848w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">ISO 8537 Anhang C<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4f5b350 e-con-full e-flex e-con e-child\" data-id=\"4f5b350\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b02950d elementor-widget elementor-widget-image\" data-id=\"b02950d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/elementor\/thumbs\/SSR-01-Syringe-Sliding-Resistance-Tester-scaled-rn4ztcwa0vu2nv5accvgu3o8gcq1q0c2tqpka41udw.webp\" title=\"SSR-01 Spritzen-Schiebewiderstandsmessger\u00e4t\" alt=\"SSR-01 Spritzen-Schiebewiderstandsmessger\u00e4t\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">SSR-01 Spritzen-Schiebewiderstandsmessger\u00e4t<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9da22d5 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"9da22d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 data-section-id=\"1qgfchs\" data-start=\"3030\" data-end=\"3069\">Losbrech- und Gleitkraftpr\u00fcfung<\/h3><p data-start=\"3071\" data-end=\"3207\"><strong data-start=\"3071\" data-end=\"3110\">Losbrech- und Gleitkraftpr\u00fcfung<\/strong> spielt eine entscheidende Rolle bei der Bewertung der Gebrauchstauglichkeit von Spritzen. Hochwertige Spritzen sollten Folgendes aufweisen:<\/p><ul data-start=\"3209\" data-end=\"3319\"><li data-section-id=\"13vpip9\" data-start=\"3209\" data-end=\"3231\">Leichtg\u00e4ngiger Kolbenweg<\/li><li data-section-id=\"6p5d4b\" data-start=\"3232\" data-end=\"3258\">Stabiles Reibungsverhalten<\/li><li data-section-id=\"7wl59y\" data-start=\"3259\" data-end=\"3286\">Minimale Kraftschwankung<\/li><li data-section-id=\"xdgzww\" data-start=\"3287\" data-end=\"3319\">Zuverl\u00e4ssige Schmierstoffleistung<\/li><\/ul><p data-start=\"3321\" data-end=\"3459\">Eine universelle Materialpr\u00fcfmaschine, die mit Kraftsensoren und ma\u00dfgeschneiderten Spritzenvorrichtungen ausgestattet ist, kann diese Parameter genau messen.<\/p><p data-start=\"3461\" data-end=\"3550\">Cell Instruments empfiehlt Pr\u00e4zisionsdruck- und Zugpr\u00fcfsysteme, die Folgendes k\u00f6nnen:<\/p><ul data-start=\"3552\" data-end=\"3716\"><li data-section-id=\"t8upzl\" data-start=\"3552\" data-end=\"3587\">Hochaufl\u00f6sende Krafterfassung<\/li><li data-section-id=\"2nuhzd\" data-start=\"3588\" data-end=\"3625\">Kraft-Weg-Kurven in Echtzeit<\/li><li data-section-id=\"1ajf2el\" data-start=\"3626\" data-end=\"3662\">Programmierbare Pr\u00fcfgeschwindigkeitskontrolle<\/li><li data-section-id=\"wk2t5e\" data-start=\"3663\" data-end=\"3716\">Statistische Analyse zur \u00dcberpr\u00fcfung der Chargenqualit\u00e4t<\/li><\/ul><p data-start=\"3718\" data-end=\"3843\">Diese Systeme helfen Spritzenherstellern bei der Optimierung der Zylinderoberfl\u00e4che, der Kolbengeometrie und der Silikonschmierverfahren.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7d5e890 e-flex e-con-boxed e-con e-parent\" data-id=\"7d5e890\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a7e615 elementor-widget elementor-widget-heading\" data-id=\"3a7e615\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Dichtheitspr\u00fcfung f\u00fcr sterile Einwegspritzen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2a1077b e-con-full e-flex e-con e-child\" data-id=\"2a1077b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bdb9680 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"bdb9680\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3898\" data-end=\"4086\"><strong data-start=\"3898\" data-end=\"3945\">Dichtheitspr\u00fcfung f\u00fcr sterile Einwegspritzen<\/strong> Produkte ist einer der wichtigsten Abschnitte der ISO 8537, da Leckagen die Sterilit\u00e4t, die Injektionsgenauigkeit und die Patientensicherheit beeintr\u00e4chtigen k\u00f6nnen.<\/p><p data-start=\"4088\" data-end=\"4116\">Der Standard bewertet beides:<\/p><ul data-start=\"4118\" data-end=\"4185\"><li data-section-id=\"1oxsryt\" data-start=\"4118\" data-end=\"4149\">Luftaustritt beim Absaugen<\/li><li data-section-id=\"1hssqyx\" data-start=\"4150\" data-end=\"4185\">Fl\u00fcssigkeitsaustritt bei der Kompression<\/li><\/ul><p data-start=\"4187\" data-end=\"4253\">Die Dichtheitspr\u00fcfung umfasst mehrere Spritzenkomponenten, darunter die:<\/p><ul data-start=\"4255\" data-end=\"4325\"><li data-section-id=\"1vo9gki\" data-start=\"4255\" data-end=\"4263\">Trommel<\/li><li data-section-id=\"30utxz\" data-start=\"4264\" data-end=\"4272\">Kolben<\/li><li data-section-id=\"152o3t3\" data-start=\"4273\" data-end=\"4289\">Gummistopfen<\/li><li data-section-id=\"1t04wdn\" data-start=\"4290\" data-end=\"4298\">Nadel<\/li><li data-section-id=\"1o447r\" data-start=\"4299\" data-end=\"4304\">Nabe<\/li><li data-section-id=\"ergued\" data-start=\"4305\" data-end=\"4325\">Anschl\u00fcsse der D\u00fcsen<\/li><\/ul><p data-start=\"4327\" data-end=\"4446\">Die zuverl\u00e4ssige Dichtungsleistung gew\u00e4hrleistet, dass unter normalen Einsatzbedingungen keine Fl\u00fcssigkeit oder Luft an den Dichtungsschnittstellen vorbeistr\u00f6mt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0151446 elementor-widget elementor-widget-image\" data-id=\"0151446\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"464\" height=\"1024\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-464x1024.png\" class=\"attachment-large size-large wp-image-895\" alt=\"ISO 8537 Schematische Darstellung einer Insulinspritze zum einmaligen Gebrauch\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-464x1024.png 464w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-136x300.png 136w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-768x1695.png 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-696x1536.png 696w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use-5x12.png 5w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/Schematic-representation-of-insulin-syringe-for-single-use.png 852w\" sizes=\"(max-width: 464px) 100vw, 464px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26e3b02 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"26e3b02\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table width=\"269\"><tbody><tr><td width=\"20\">1<\/td><td width=\"100\">Nadelkappe<\/td><td width=\"28\">10<\/td><td width=\"121\">St\u00f6\u00dfelkappe<\/td><\/tr><tr><td width=\"20\">2<\/td><td width=\"100\">D\u00fcsenkappe<\/td><td width=\"28\">11<\/td><td width=\"121\">Fingergriffe<\/td><\/tr><tr><td width=\"20\">3<\/td><td width=\"100\">D\u00fcsenlumen<\/td><td width=\"28\">12<\/td><td width=\"121\">Passermarkenlinie<\/td><\/tr><tr><td width=\"20\">4<\/td><td width=\"100\">D\u00fcse<\/td><td width=\"28\">13<\/td><td width=\"121\">Nennkapazit\u00e4t<\/td><\/tr><tr><td width=\"20\">5<\/td><td width=\"100\">Fass<\/td><td width=\"28\">14<\/td><td width=\"121\">Teilstriche<\/td><\/tr><tr><td width=\"20\">6<\/td><td width=\"100\">St\u00f6psel<\/td><td width=\"28\">15<\/td><td width=\"121\">Null-Linie<\/td><\/tr><tr><td width=\"20\">7<\/td><td width=\"100\">Dichtungen<\/td><td width=\"28\">16<\/td><td width=\"121\">Nadelr\u00f6hre<\/td><\/tr><tr><td width=\"20\">8<\/td><td width=\"100\">Plunger<\/td><td width=\"28\">17<\/td><td width=\"121\">Nabe<\/td><\/tr><tr><td width=\"20\">9<\/td><td width=\"100\">Drucktaste<\/td><td>\u00a0<\/td><td>\u00a0<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5ca68da e-flex e-con-boxed e-con e-parent\" data-id=\"5ca68da\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c08b839 elementor-widget elementor-widget-heading\" data-id=\"c08b839\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Spritzen-Luftlecktest und Vakuum-Lecksuchverfahren<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1de7ad8 elementor-widget elementor-widget-text-editor\" data-id=\"1de7ad8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4516\" data-end=\"4635\">Die <strong data-start=\"4520\" data-end=\"4548\">Luftdichtheitspr\u00fcfung der Spritze<\/strong> nach Anhang B und Anhang F bewertet die Leckage unter Unterdruckbedingungen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-662d174 e-con-full e-flex e-con e-child\" data-id=\"662d174\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-e09dc78 e-con-full e-flex e-con e-child\" data-id=\"e09dc78\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6604812 elementor-widget elementor-widget-text-editor\" data-id=\"6604812\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4637\" data-end=\"4847\">In Anhang B wird die D\u00fcse der Spritze mit einer Referenzarmatur verbunden und die Spritze teilweise mit Wasser gef\u00fcllt. Ein Vakuum von <strong data-start=\"4760\" data-end=\"4797\">88 kPa unter Atmosph\u00e4rendruck<\/strong> wird schrittweise angewendet. Der Bediener pr\u00fcft dann:<\/p><ul data-start=\"4849\" data-end=\"4972\"><li data-section-id=\"nfom55\" data-start=\"4849\" data-end=\"4883\">Luftaustritt an der Kolbendichtung<\/li><li data-section-id=\"cbijpf\" data-start=\"4884\" data-end=\"4920\">Druckstabilit\u00e4t \u00fcber 60 Sekunden<\/li><li data-section-id=\"y5dh1c\" data-start=\"4921\" data-end=\"4972\">Trennung zwischen Gummistopfen und St\u00f6\u00dfel<\/li><\/ul><p data-start=\"4974\" data-end=\"5081\">Dieses Verfahren ist eines der wirksamsten <strong data-start=\"5026\" data-end=\"5059\">Methoden der Vakuum-Lecksuche<\/strong> f\u00fcr Insulinspritzen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-367cbd1 elementor-widget elementor-widget-image\" data-id=\"367cbd1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"429\" height=\"343\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-B.webp\" class=\"attachment-large size-large wp-image-883\" alt=\"ISO 8537 Anhang B Luftaustritt w\u00e4hrend der Aspiration\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-B.webp 429w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-B-300x240.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/ISO-8537-Annex-B-15x12.webp 15w\" sizes=\"(max-width: 429px) 100vw, 429px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">ISO 8537 Anhang B Luftaustritt w\u00e4hrend der Aspiration<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b2032f elementor-widget elementor-widget-image\" data-id=\"6b2032f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"679\" height=\"1024\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-679x1024.webp\" class=\"attachment-large size-large wp-image-884\" alt=\"SLT-02 Spritzen-Dichtheitspr\u00fcfung\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-679x1024.webp 679w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-199x300.webp 199w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-768x1158.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1019x1536.webp 1019w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-1358x2048.webp 1358w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-8x12.webp 8w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SLT-02-Syringe-Leak-Testee-scaled.webp 1698w\" sizes=\"(max-width: 679px) 100vw, 679px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">SLT-02 Spritzen-Leck-Tester<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2baf071 e-flex e-con-boxed e-con e-parent\" data-id=\"2baf071\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3458faa elementor-widget elementor-widget-heading\" data-id=\"3458faa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Spritzenfl\u00fcssigkeitsleckagetest unter Kompression<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e6d789e e-con-full e-flex e-con e-child\" data-id=\"e6d789e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d45890 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"7d45890\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"5667\" data-end=\"5789\">Die <strong data-start=\"5671\" data-end=\"5702\">Dichtheitspr\u00fcfung von Spritzen<\/strong> nach Anhang E bewertet die Dichtheit unter Innendruckbedingungen.<\/p><p data-start=\"5791\" data-end=\"5806\">Die Spritze ist:<\/p><ol data-start=\"5808\" data-end=\"5928\"><li data-section-id=\"6wnabh\" data-start=\"5808\" data-end=\"5841\">\u00dcber das Nennvolumen hinaus bef\u00fcllt<\/li><li data-section-id=\"1fqlmrf\" data-start=\"5842\" data-end=\"5858\">Von Luft gereinigt<\/li><li data-section-id=\"1qsq13s\" data-start=\"5859\" data-end=\"5884\">Druckbeaufschlagung mit 300 kPa<\/li><li data-section-id=\"96c87l\" data-start=\"5885\" data-end=\"5928\">30 Sekunden lang unter Druck gehalten<\/li><\/ol><p data-start=\"5930\" data-end=\"5967\">W\u00e4hrend der Pr\u00fcfung bewerten die Inspektoren:<\/p><ul data-start=\"5969\" data-end=\"6054\"><li data-section-id=\"yefbo4\" data-start=\"5969\" data-end=\"5986\">Bewegung des Kolbens<\/li><li data-section-id=\"te6jnt\" data-start=\"5987\" data-end=\"6014\">Leckage an den Kolbendichtungen<\/li><li data-section-id=\"hl3ixi\" data-start=\"6015\" data-end=\"6054\">Leckage an D\u00fcsen- oder Nadelanschl\u00fcssen<\/li><\/ul><p data-start=\"6056\" data-end=\"6141\">Mit dieser Methode wird die Integrit\u00e4t der Dichtungsschnittstellen w\u00e4hrend der Injektionssimulation \u00fcberpr\u00fcft.<\/p><p data-start=\"6143\" data-end=\"6227\">Ein richtig konzipiertes Druckdichtheitspr\u00fcfsystem kann den Herstellern bei der Bewertung helfen:<\/p><ul data-start=\"6229\" data-end=\"6353\"><li data-section-id=\"swbrf5\" data-start=\"6229\" data-end=\"6261\">Qualit\u00e4t der Gummistopfenabdichtung<\/li><li data-section-id=\"1ekpexs\" data-start=\"6262\" data-end=\"6291\">Zuverl\u00e4ssigkeit der Luer-Verbindung<\/li><li data-section-id=\"1dtrbjl\" data-start=\"6292\" data-end=\"6324\">Ma\u00dfhaltigkeit des Fasses<\/li><li data-section-id=\"1wg6zas\" data-start=\"6325\" data-end=\"6353\">Leistung der Nadelverklebung<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e65e0c6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"e65e0c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"465\" height=\"1024\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-465x1024.webp\" class=\"attachment-large size-large wp-image-885\" alt=\"SPPT-01 Spritzen-\u00dcberdruck-Dichtheitspr\u00fcfger\u00e4t\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-465x1024.webp 465w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-136x300.webp 136w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-768x1690.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-698x1536.webp 698w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-931x2048.webp 931w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-5x12.webp 5w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2026\/05\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester-scaled.webp 1164w\" sizes=\"(max-width: 465px) 100vw, 465px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">SPPT-01 Spritzen-\u00dcberdruck-Dichtheitspr\u00fcfger\u00e4t<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4073de e-flex e-con-boxed e-con e-parent\" data-id=\"d4073de\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-758cd11 elementor-widget elementor-widget-heading\" data-id=\"758cd11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Totraummessung f\u00fcr Spritzengenauigkeit<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6da682f elementor-widget elementor-widget-text-editor\" data-id=\"6da682f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"6408\" data-end=\"6526\"><strong data-start=\"6408\" data-end=\"6434\">Messung des Totraums<\/strong> ist bei Insulinspritzen unerl\u00e4sslich, da sich Fl\u00fcssigkeitsreste direkt auf die Dosiergenauigkeit auswirken.<\/p><p data-start=\"6528\" data-end=\"6620\">ISO 8537 definiert den Totraum als das verbleibende Wasservolumen nach vollst\u00e4ndigem Eindr\u00fccken des Kolbens.<\/p><p data-start=\"6622\" data-end=\"6645\">Das Verfahren umfasst:<\/p><ul data-start=\"6647\" data-end=\"6775\"><li data-section-id=\"14dqth4\" data-start=\"6647\" data-end=\"6684\">Genaues Wiegen von leeren Spritzen<\/li><li data-section-id=\"6xmjzm\" data-start=\"6685\" data-end=\"6715\">Bef\u00fcllung mit destilliertem Wasser<\/li><li data-section-id=\"1y173or\" data-start=\"6716\" data-end=\"6746\">Vollst\u00e4ndiger Aussto\u00df von Fl\u00fcssigkeit<\/li><li data-section-id=\"fuewb\" data-start=\"6747\" data-end=\"6775\">Erneutes Wiegen nach der Entlassung<\/li><\/ul><p data-start=\"6777\" data-end=\"6827\">Die verbleibende Masse entspricht dem Restvolumen.<\/p><p data-start=\"6829\" data-end=\"6858\">Spritzen mit geringem Totraum helfen:<\/p><ul data-start=\"6860\" data-end=\"6950\"><li data-section-id=\"xvtq2v\" data-start=\"6860\" data-end=\"6885\">Verringerung der Medikamentenverschwendung<\/li><li data-section-id=\"juz4tb\" data-start=\"6886\" data-end=\"6912\">Verbesserung der Dosierungsgenauigkeit<\/li><li data-section-id=\"10nqsv3\" data-start=\"6913\" data-end=\"6950\">Minimierung der Restinsulinr\u00fcckhaltung<\/li><\/ul><p data-start=\"6952\" data-end=\"7092\">Pr\u00fcfger\u00e4te mit analytischen Waagen und kontrollierten Handhabungsvorrichtungen verbessern die Messkonsistenz f\u00fcr Qualit\u00e4tssicherungsprogramme.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c7f4aa5 e-flex e-con-boxed e-con e-parent\" data-id=\"c7f4aa5\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9a263b1 elementor-widget elementor-widget-heading\" data-id=\"9a263b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Bedeutung der Pr\u00fcfung von Spritzenkomponenten<br><small>---D\u00fcse, Nabe, Nadel, Zylinder, Kolben und Gummistopfen<\/small><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-088c9f2 elementor-widget elementor-widget-text-editor\" data-id=\"088c9f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"7201\" data-end=\"7307\">Bei der Pr\u00fcfung nach ISO 8537 wird die Interaktion zwischen mehreren Spritzenkomponenten und nicht zwischen einzelnen Teilen bewertet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ee707f7 e-con-full e-flex e-con e-child\" data-id=\"ee707f7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-af54839 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"af54839\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"7201\" data-end=\"7307\">\u00a0Zu den kritischen Schnittstellen geh\u00f6ren:<\/p><div class=\"TyagGW_tableContainer\"><div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"7339\" data-end=\"7613\"><thead data-start=\"7339\" data-end=\"7376\"><tr data-start=\"7339\" data-end=\"7376\"><th class=\"\" data-start=\"7339\" data-end=\"7351\" data-col-size=\"sm\">Komponente<\/th><th class=\"\" data-start=\"7351\" data-end=\"7376\" data-col-size=\"sm\">Funktionale Bedeutung<\/th><\/tr><\/thead><tbody data-start=\"7387\" data-end=\"7613\"><tr data-start=\"7387\" data-end=\"7424\"><td data-start=\"7387\" data-end=\"7396\" data-col-size=\"sm\">D\u00fcse<\/td><td data-start=\"7396\" data-end=\"7424\" data-col-size=\"sm\">Integrit\u00e4t der Fl\u00fcssigkeits\u00fcbertragung<\/td><\/tr><tr data-start=\"7425\" data-end=\"7462\"><td data-start=\"7425\" data-end=\"7431\" data-col-size=\"sm\">Nabe<\/td><td data-start=\"7431\" data-end=\"7462\" data-col-size=\"sm\">Stabilit\u00e4t der Nadelverbindung<\/td><\/tr><tr data-start=\"7463\" data-end=\"7497\"><td data-start=\"7463\" data-end=\"7472\" data-col-size=\"sm\">Nadel<\/td><td data-start=\"7472\" data-end=\"7497\" data-col-size=\"sm\">Einspritzleistung<\/td><\/tr><tr data-start=\"7498\" data-end=\"7531\"><td data-start=\"7498\" data-end=\"7507\" data-col-size=\"sm\">Trommel<\/td><td data-start=\"7507\" data-end=\"7531\" data-col-size=\"sm\">Ma\u00dfhaltigkeit<\/td><\/tr><tr data-start=\"7532\" data-end=\"7573\"><td data-start=\"7532\" data-end=\"7541\" data-col-size=\"sm\">Kolben<\/td><td data-start=\"7541\" data-end=\"7573\" data-col-size=\"sm\">Reibungsloser Betrieb und Abdichtung<\/td><\/tr><tr data-start=\"7574\" data-end=\"7613\"><td data-start=\"7574\" data-end=\"7591\" data-col-size=\"sm\">Gummistopfen<\/td><td data-start=\"7591\" data-end=\"7613\" data-col-size=\"sm\">Verhinderung von Leckagen<\/td><\/tr><\/tbody><\/table><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2b1852b elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"2b1852b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"7615\" data-end=\"7668\">Jede Unstimmigkeit zwischen diesen Komponenten kann dazu f\u00fchren:<\/p><ul data-start=\"7670\" data-end=\"7749\"><li data-section-id=\"ujvyq0\" data-start=\"7670\" data-end=\"7679\">Durchsickern<\/li><li data-section-id=\"1g1kth9\" data-start=\"7680\" data-end=\"7703\">Instabilit\u00e4t der Injektion<\/li><li data-section-id=\"rmryg9\" data-start=\"7704\" data-end=\"7731\">\u00dcberm\u00e4\u00dfige Bet\u00e4tigungskraft<\/li><li data-section-id=\"17chdkf\" data-start=\"7732\" data-end=\"7749\">Ungenauigkeit der Dosis<\/li><\/ul><p data-start=\"7751\" data-end=\"7845\">Umfassende Pr\u00fcfungen erfordern daher integrierte mechanische und Leckage-Bewertungssysteme.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 8537 definiert kritische Pr\u00fcfverfahren f\u00fcr sterile Einweg-Insulinspritzen, einschlie\u00dflich der Dichtheitspr\u00fcfung von Spritzen, Verfahren zur Pr\u00fcfung der Unversehrtheit der Spritzendichtung, der Pr\u00fcfung der Gleitkraft von Spritzen und der Messung des Totraums.<\/p>","protected":false},"author":2,"featured_media":0,"parent":603,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-878","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/pages\/878","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/comments?post=878"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/pages\/878\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/pages\/603"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/media?parent=878"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}