{"id":265,"date":"2025-05-06T03:29:29","date_gmt":"2025-05-06T03:29:29","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=265"},"modified":"2026-05-09T06:39:48","modified_gmt":"2026-05-09T06:39:48","slug":"luer-lock-adaptor-collar-pull-off-force","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/de\/luer-lock-adaptor-collar-pull-off-force","title":{"rendered":"Luer-Lock-Adapter Manschette Abzugskraft"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"265\" class=\"elementor elementor-265\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0ebe6b e-flex e-con-boxed e-con e-parent\" data-id=\"c0ebe6b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d6d91c9 elementor-widget elementor-widget-heading\" data-id=\"d6d91c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Luer-Lock-Adapter Manschette Abzugskraft<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0a5f59 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"f0a5f59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In der pharmazeutischen und medizintechnischen Industrie ist es von entscheidender Bedeutung, die Integrit\u00e4t der Spritzenkomponenten zu gew\u00e4hrleisten. Eine wesentliche Qualit\u00e4tspr\u00fcfung ist dieser Test. Bei dieser Pr\u00fcfung wird die Festigkeit der Verbindung zwischen dem Luer-Lock-Adapter (LLA) und dem Spritzenzylinder gemessen, um eine Trennung der Komponenten w\u00e4hrend des Gebrauchs zu verhindern.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7e51b6e e-flex e-con-boxed e-con e-parent\" data-id=\"7e51b6e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a359504 elementor-widget elementor-widget-heading\" data-id=\"a359504\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Die Bedeutung der Pr\u00fcfung der Abzugskraft von Luer-Lock-Adaptermanschetten<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de744c7 elementor-widget elementor-widget-text-editor\" data-id=\"de744c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ist die Abzugskraft des Luer-Lock-Adapterkragens zu gering, kann sich der Kragen w\u00e4hrend der Handhabung oder Injektion von der Spritze l\u00f6sen, was zum Auslaufen des Medikaments, einer unvollst\u00e4ndigen Dosierung oder sogar zu schweren Verletzungen des Patienten f\u00fchren kann. Ist die Kraft hingegen zu hoch, kann der Montageprozess schwierig werden, was das Risiko von Besch\u00e4digungen w\u00e4hrend der Herstellung erh\u00f6ht.<\/p><p>Daher ist die Durchf\u00fchrung dieser standardisierten Tests von entscheidender Bedeutung, um die sichere Befestigung der Manschette zu gew\u00e4hrleisten, die Funktionssicherheit der Spritze aufrechtzuerhalten und die Sicherheit der Patienten zu sch\u00fctzen.<\/p><p><strong>Syringetest.de<\/strong> bietet pr\u00e4zise, zuverl\u00e4ssige Pr\u00fcfger\u00e4te f\u00fcr <em>Abzugskraft des Luer-Lock-Adapterkragens<\/em> Bewertungen, die sicherstellen, dass Ihre Spritzen die globalen Qualit\u00e4tsstandards zuverl\u00e4ssig erf\u00fcllen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f3ad5f2 e-flex e-con-boxed e-con e-parent\" data-id=\"f3ad5f2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d69bf22 elementor-widget elementor-widget-heading\" data-id=\"d69bf22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 und ISO 11040-4 Anhang G3<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c32614c e-con-full e-flex e-con e-child\" data-id=\"c32614c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fcd1b36 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"fcd1b36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die <a href=\"https:\/\/www.syringetest.com\/de\/standards\/iso-11040-4\/\"><em>ISO 11040-4<\/em><\/a> Standard, insbesondere <em>ISO 11040-4 Anhang G3<\/em>skizziert das Verfahren f\u00fcr die <em>Abzugskraft des Luer-Lock-Adapterkragens<\/em> Pr\u00fcfung. Gem\u00e4\u00df diesen Normen wird mit der Abzugskraftpr\u00fcfung die F\u00e4higkeit des Manschettensystems \u00fcberpr\u00fcft, axialen Kr\u00e4ften standzuhalten, um sicherzustellen, dass die Spritzen bei kritischen Vorg\u00e4ngen wie der Verabreichung von Medikamenten intakt bleiben. Die Methode legt Wert auf gleichbleibende Pr\u00fcfgeschwindigkeiten, eine geeignete Auswahl der Kraftmessdosen und hochfrequente Probenahmen, um genaue und zuverl\u00e4ssige Daten zu gew\u00e4hrleisten.<\/p><p>Unter <em>ISO 11040-4 Anhang G3<\/em> verbessert die Testkonsistenz zwischen Laboren und Herstellern und f\u00f6rdert das Vertrauen in die Produktqualit\u00e4t und die Einhaltung von Vorschriften.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0502b44 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"0502b44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"515\" height=\"350\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" class=\"attachment-medium_large size-medium_large wp-image-272\" alt=\"Abzugskraft der Luer-Lock-Adaptermanschette - ISO 11040-4 Anhang G3\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp 515w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing-300x204.webp 300w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c33ea3f e-flex e-con-boxed e-con e-parent\" data-id=\"c33ea3f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b8731e5 elementor-widget elementor-widget-heading\" data-id=\"b8731e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prinzip des Abzugskrafttests der Luer-Lock-Adaptermanschette<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-931bcc4 elementor-widget elementor-widget-text-editor\" data-id=\"931bcc4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Der Kerngedanke dieses Tests ist einfach: Er misst die maximale axiale Kraft, die erforderlich ist, um den LLA-Kragen vom Spritzenzylinder zu l\u00f6sen. Eine starke Abzugskraft bedeutet, dass die LLA-Manschette sicher befestigt ist, wodurch das Risiko einer Abl\u00f6sung w\u00e4hrend der Anwendung minimiert wird.<\/p><p>Das Schl\u00fcsselprinzip konzentriert sich auf:<\/p><ul><li>Simulation einer realistischen mechanischen Belastung.<\/li><li>Es wird sichergestellt, dass die Einf\u00fchrungskr\u00e4fte von Standard-Luer-Anschl\u00fcssen nicht zu einer Abl\u00f6sung der Manschette f\u00fchren.<\/li><li>Erfassen von Spitzenkraftdaten durch Kraft-Weg-Analyse.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cbb1f00 e-flex e-con-boxed e-con e-parent\" data-id=\"cbb1f00\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9e34cbf elementor-widget elementor-widget-heading\" data-id=\"9e34cbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Erforderliche Ger\u00e4te und Materialien<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29c5058 elementor-widget elementor-widget-text-editor\" data-id=\"29c5058\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Genaue Pr\u00fcfung von <em>Abzugskraft des Luer-Lock-Adapterkragens<\/em> erfordert Pr\u00e4zisionsger\u00e4te:<\/p><ul><li><strong>Universal-Zug- und Druckpr\u00fcfmaschine <\/strong>mit:<ul><li>Die Pr\u00fcfgeschwindigkeit ist auf 20 mm\/min eingestellt (ggf. gem\u00e4\u00df ISO 80369-7).<\/li><li>W\u00e4gezelle geeignet f\u00fcr einen Kraftbereich von 10 N bis 100 N.<\/li><\/ul><\/li><li><strong>Spritzenhalter und Greifvorrichtung<\/strong> die sowohl den Spritzenzylinder als auch den LLA-Kragen sichert, ohne unerw\u00fcnschten Druck auszu\u00fcben.<\/li><\/ul><p><strong>Materialien:<\/strong><\/p><ul><li>Sterilisierte, vormontierte und f\u00fcllfertige Spritzen, einschlie\u00dflich des LLA-Systems.<\/li><\/ul><p><strong>Das ist wichtig:<\/strong><br \/>Die Abtastrate muss mindestens 100 Hz f\u00fcr allgemeine Pr\u00fcfungen und 500 Hz f\u00fcr Spitzenmessungen betragen, um eine feine Datenaufl\u00f6sung und Genauigkeit zu gew\u00e4hrleisten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-61d3079 e-flex e-con-boxed e-con e-parent\" data-id=\"61d3079\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bd94a54 elementor-widget elementor-widget-heading\" data-id=\"bd94a54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testverfahren f\u00fcr die Abzugskraft der Luer-Lock-Adaptermanschette<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc41e63 elementor-widget elementor-widget-text-editor\" data-id=\"fc41e63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die korrekte Durchf\u00fchrung dieses Tests gew\u00e4hrleistet genaue, wiederholbare Ergebnisse:<\/p><h3>1. Probenvorbereitung<\/h3><p>Verwenden Sie Spritzen, die den vollst\u00e4ndigen Sterilisations- und Aufbereitungsprozess durchlaufen haben.<\/p><h3>2. Einrichtung<\/h3><ul><li>Nehmen Sie die Kappe vorsichtig ab.<\/li><li>Sichern Sie die Spritze senkrecht zwischen Halter (Fingerflansch) und Greifer (LLA-Kragen), ohne den Kragen zu belasten.<\/li><\/ul><h3>3. Testdurchf\u00fchrung<\/h3><ul><li>Stellen Sie die W\u00e4gezelle auf Null, so dass keine Vorspannung vorhanden ist.<\/li><li>Wenden Sie eine Zugkraft von 20 mm\/min an.<\/li><li>Zeichnen Sie die Kraft-Weg-Kurve kontinuierlich auf.<\/li><\/ul><h3>4. Beenden des Tests<\/h3><p>Brechen Sie den Test ab, wenn sich die LLA-Manschette deutlich von der Spritze l\u00f6st.<\/p><h3>5. Ergebnisaufzeichnung<\/h3><p>Die maximale Kraftspitze auf der Kurve stellt die <em>Abzugskraft<\/em>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc4abbc e-grid e-con-full e-con e-parent\" data-id=\"dc4abbc\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99d351b elementor-widget elementor-widget-image\" data-id=\"99d351b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ccc877e e-con-full e-flex e-con e-child\" data-id=\"ccc877e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef33af7 elementor-widget elementor-widget-heading\" data-id=\"ef33af7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Warum w\u00e4hlen <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b43d751 elementor-widget elementor-widget-text-editor\" data-id=\"b43d751\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"203\" data-end=\"463\">Unter <strong>Syringetest.de<\/strong>Wir vereinen Fachwissen, Innovation, pr\u00e4zise Technik und pers\u00f6nlichen Service, um unsere Kunden weltweit zu unterst\u00fctzen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28e0c7c elementor-widget elementor-widget-text-editor\" data-id=\"28e0c7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Durchf\u00fchren der <em>Abzugskraft des Luer-Lock-Adapterkragens<\/em> Pr\u00fcfung nach <em>ISO 11040-4 Anhang G3<\/em> ist entscheidend f\u00fcr die mechanische Sicherheit von Luer-Lock-Spritzen. Die ordnungsgem\u00e4\u00dfe Ausf\u00fchrung und Dokumentation bieten die Gew\u00e4hr, dass die Spritzen den Belastungen des klinischen Einsatzes ohne Ausfall standhalten.<br \/>Verlassen Sie sich auf <strong>Syringetest.de<\/strong> f\u00fcr hochmoderne Testl\u00f6sungen, die die Qualit\u00e4t und Sicherheit Ihrer Spritzenprodukte verbessern.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5463cac elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"5463cac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/de\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Adaptor Collar Pull-Off Force In the pharmaceutical and medical device industries, ensuring the integrity of syringe components is critical. One essential quality check is the this test. This evaluation measures the strength of the connection between the Luer lock adaptor (LLA) collar and the syringe barrel, preventing component separation during use. The Importance [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-265","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/pages\/265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/comments?post=265"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/pages\/265\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/media?parent=265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}