{"id":205,"date":"2025-04-30T07:52:58","date_gmt":"2025-04-30T07:52:58","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=205"},"modified":"2026-05-09T07:32:11","modified_gmt":"2026-05-09T07:32:11","slug":"needle-bonding-strength-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/de\/needle-bonding-strength-test","title":{"rendered":"Pr\u00fcfung der Nadelbindefestigkeit"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"205\" class=\"elementor elementor-205\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11915ec e-flex e-con-boxed e-con e-parent\" data-id=\"11915ec\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1b7a35f elementor-widget elementor-widget-heading\" data-id=\"1b7a35f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Pr\u00fcfung der Nadelbindefestigkeit<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-295ce65 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"295ce65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die <strong>Nadelklebkraft<\/strong> Pr\u00fcfung ist eine wesentliche Qualit\u00e4tssicherungsma\u00dfnahme in der Spritzenherstellung. Bei dieser Pr\u00fcfung wird festgestellt, ob die Verbindung zwischen Nadel und Spritze - oder zwischen Nadel und Nabe - den zu erwartenden Zugkr\u00e4ften w\u00e4hrend des Gebrauchs standhalten kann. Eine schwache Verbindung kann zu ernsthaften Sicherheitsrisiken wie Auslaufen, Abl\u00f6sen der Nadel oder Verletzungen des Patienten f\u00fchren.<\/p><p>Angesichts der lebenswichtigen Anwendungen von Spritzen im medizinischen, pharmazeutischen und biotechnologischen Bereich sind zuverl\u00e4ssige <strong>Spritzenversuch<\/strong> unter international anerkannten Standards wie <strong>ISO 11040-4 Anhang G1<\/strong>, <strong>ISO 7864<\/strong>und <strong>ISO 11608-2<\/strong> ist unabdingbar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0078138 e-flex e-con-boxed e-con e-parent\" data-id=\"0078138\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99fd12a elementor-widget elementor-widget-heading\" data-id=\"99fd12a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Die Bedeutung der Festigkeitspr\u00fcfung von Nadelbindungen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-489ffe8 elementor-widget elementor-widget-text-editor\" data-id=\"489ffe8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Haftfestigkeit von Nadeln ist ein entscheidender Leistungsparameter bei Spritzen- und Nadelsystemen, insbesondere bei vorgef\u00fcllten Spritzen und nadelbasierten Injektionsger\u00e4ten. Sie entscheidet dar\u00fcber, ob eine Nadel w\u00e4hrend der Anwendung sicher an der Spritze oder der Kan\u00fcle befestigt bleibt, um eine sichere und effektive Medikamentenabgabe zu gew\u00e4hrleisten. Ein Versagen der Haftfestigkeit kann zum Abl\u00f6sen der Nadel, zu Verletzungen des Patienten oder zu einer unvollst\u00e4ndigen Dosierung f\u00fchren - was ein erhebliches Sicherheitsrisiko darstellt.<\/p><p>Das Herzst\u00fcck der Qualit\u00e4tssicherung von Spritzen ist die <strong>Pr\u00fcfung der Nadelhaftfestigkeit<\/strong> bietet eine wesentliche Validierung f\u00fcr die Produktzuverl\u00e4ssigkeit, die Patientensicherheit und die Einhaltung gesetzlicher Vorschriften. Diese Pr\u00fcfungen entsprechen internationalen Standards wie <strong>ISO 11040-4 Anhang G1<\/strong>, <strong>ISO 7864<\/strong>und <strong>ISO 11608-2<\/strong>die alle spezifische Verfahren und Leistungsschwellen f\u00fcr die Klebekraft bei verschiedenen Arten von Spritzenverbindungen festlegen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0ceb936 e-flex e-con-boxed e-con e-parent\" data-id=\"0ceb936\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7056e55 elementor-widget elementor-widget-heading\" data-id=\"7056e55\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verwandte Normen f\u00fcr die Pr\u00fcfung der Nadelbindefestigkeit<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54d2ea3 elementor-widget elementor-widget-text-editor\" data-id=\"54d2ea3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die ISO-Leitlinien bieten einen soliden Rahmen f\u00fcr die Bewertung von <strong>Nadelklebkraft<\/strong> f\u00fcr verschiedene Spritzen- und Nadeltypen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cafe546 e-con-full e-flex e-con e-child\" data-id=\"cafe546\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e0674d5 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"e0674d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>ISO 11040-4 Anhang G1<\/h3><p>Konzentriert sich auf vorgef\u00fcllte Spritzen mit gestochenen Nadeln. Er beschreibt den Aufbau der Ausr\u00fcstung und das Verfahren zur Messung <strong>Nadelauszugskraft<\/strong>Dadurch wird die Integrit\u00e4t des Nadelfixierungsprozesses gew\u00e4hrleistet.<\/p><h3>ISO 7864 Anhang E<\/h3><p>Umrei\u00dft Pr\u00fcfverfahren f\u00fcr <strong>Injektionsnadeln<\/strong>Dabei wird insbesondere die Verbindung zwischen dem Nadelansatz und dem Nadelrohr gepr\u00fcft.<\/p><h3>ISO 11608-2 Anhang B<\/h3><p>Dieser Anhang bezieht sich auf Einmalspritzen f\u00fcr Insulin und definiert die Anforderungen an die Gleitkraft f\u00fcr eine genaue und gleichm\u00e4\u00dfige Insulinabgabe.\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b91224d elementor-widget elementor-widget-image\" data-id=\"b91224d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"515\" height=\"350\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" class=\"attachment-large size-large wp-image-207\" alt=\"Pr\u00fcfung der Nadelbindungsst\u00e4rke - Pr\u00fcfung von Spritzennadeln\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp 515w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing-300x204.webp 300w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6567345 elementor-widget elementor-widget-text-editor\" data-id=\"6567345\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In jeder Norm werden kritische Parameter festgelegt, wie z. B.:<\/p><ul><li>Verwendung eines <strong>Universal-Zug- und Druckpr\u00fcfmaschine<\/strong>.<\/li><li>Eine Standard-Testgeschwindigkeit von <strong>50 mm\/min<\/strong>.<\/li><li>Geeignete Abtastrate (typischerweise <strong>\u2265100 Hz<\/strong>und <strong>500 Hz<\/strong> f\u00fcr die Genauigkeit der Spitzenkraft).<\/li><li>Geeignete Nadelgreifmechanismen zur Vermeidung von Schlupf und Messst\u00f6rungen.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fc94bb4 e-flex e-con-boxed e-con e-parent\" data-id=\"fc94bb4\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5df17a7 elementor-widget elementor-widget-heading\" data-id=\"5df17a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Das Verfahren zur Pr\u00fcfung der Nadelbindefestigkeit<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc1819f elementor-widget elementor-widget-text-editor\" data-id=\"fc1819f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 data-start=\"2125\" data-end=\"2247\">1. Probenvorbereitung<\/h3><p class=\"\" data-start=\"2125\" data-end=\"2247\">Verwenden Sie sterilisierte Spritzen- oder Nadelproben, die auf die gleiche Weise hergestellt wurden wie die tats\u00e4chlichen Produktionschargen.<\/p><h3>2. Einrichtung der Ausr\u00fcstung:<\/h3><ul><li>Sichern Sie die Spritze oder Nadel mit einer <strong>Halterung<\/strong> die die richtige axiale Ausrichtung unterst\u00fctzt.<\/li><li>Befestigen Sie die <strong>Nadelgreifer<\/strong>-Entworfen, um zu greifen, ohne sich zu verformen oder zu verrutschen.<\/li><li>Richten Sie die <strong>Zugfestigkeitspr\u00fcfger\u00e4t<\/strong> mit einem geeigneten <strong>W\u00e4gezelle<\/strong> (je nach Anwendung bis zu 500 N).<\/li><\/ul><h3>3. Testdurchf\u00fchrung:<\/h3><ul><li>Nullstellung der W\u00e4gezelle ohne Vorlast.<\/li><li>F\u00fchren Sie den Test unter <strong>50 mm\/min<\/strong>Datenerfassung mit einer ausreichenden Abtastrate.<\/li><li>Messen und notieren Sie die <strong>maximale Zugkraft<\/strong> vor dem Abl\u00f6sen oder Versagen angewendet werden.<\/li><\/ul><h3>4. Auswertung der Daten:<\/h3><ul><li>Analysieren Sie die <strong>Kraft-Weg-Kurve<\/strong> um die maximale Bindungsst\u00e4rke zu ermitteln.<\/li><li>\u00dcberpr\u00fcfen Sie die Ergebnisse anhand vordefinierter Akzeptanzkriterien aus ISO- oder internen Protokollen.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1103d96 elementor-widget elementor-widget-text-editor\" data-id=\"1103d96\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine ordnungsgem\u00e4\u00dfe Dokumentation der Pr\u00fcfergebnisse, einschlie\u00dflich aller Abweichungen, ist f\u00fcr die R\u00fcckverfolgbarkeit und die Pr\u00fcfung der Einhaltung von Vorschriften unerl\u00e4sslich.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-99b8376 e-grid e-con-full e-con e-parent\" data-id=\"99b8376\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-42da099 elementor-widget elementor-widget-image\" data-id=\"42da099\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-80b6864 e-con-full e-flex e-con e-child\" data-id=\"80b6864\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7980158 elementor-widget elementor-widget-heading\" data-id=\"7980158\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Warum w\u00e4hlen <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a37b10d elementor-widget elementor-widget-text-editor\" data-id=\"a37b10d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Unter <strong>Zelle Instrumente<\/strong>bieten wir spezialisierte Zugpr\u00fcfsysteme an, die speziell f\u00fcr Nadelklebeanwendungen entwickelt wurden. Unsere Ger\u00e4te entsprechen den Anforderungen:<\/p><ul><li>ISO 11040-4 Anhang G1<\/li><li>ISO 7864<\/li><li>ISO 11608-2<\/li><\/ul><p>Die Merkmale umfassen:<\/p><ul><li>Hochpr\u00e4zise <strong>W\u00e4gezellen<\/strong> f\u00fcr eine genaue Kraftmessung.<\/li><li>Konfigurierbar <strong>Nadelgreifer<\/strong> und <strong>Spritzenhalter<\/strong>.<\/li><li>Intuitive Software f\u00fcr <strong>Kraft-Weg-Analyse in Echtzeit<\/strong> und automatische Berichterstellung.<\/li><\/ul><p>Wir bieten auch <strong>kundenspezifische Befestigungen<\/strong> und <strong>Automatisierungsl\u00f6sungen<\/strong> f\u00fcr F&amp;E- und Produktionspr\u00fcfungsanforderungen.<\/p><p>Ob Sie ein <strong>Qualit\u00e4tskontrolleur<\/strong>, <strong>Regulierungsspezialist<\/strong>, oder <strong>Spritzenhersteller<\/strong>Cell Instruments ist Ihr Partner f\u00fcr eine zuverl\u00e4ssige, effiziente und ISO-konforme Spritzenpr\u00fcfung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-43c643d elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"43c643d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/de\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Needle Bonding Strength Testing The needle bonding strength test is an essential quality assurance measure in the syringe manufacturing industry. This test determines whether the connection between the needle and syringe\u2014or the needle and hub\u2014can withstand expected tensile forces during use. Weak bonding could result in serious safety risks such as leakage, needle detachment, or [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-205","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/pages\/205","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/comments?post=205"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/pages\/205\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/de\/wp-json\/wp\/v2\/media?parent=205"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}