{"id":277,"date":"2025-05-06T05:39:02","date_gmt":"2025-05-06T05:39:02","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=277"},"modified":"2025-05-06T06:34:32","modified_gmt":"2025-05-06T06:34:32","slug":"luer-lock-adaptor-collar-torque-resistance","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/da\/luer-lock-adaptor-collar-torque-resistance","title":{"rendered":"Luer Lock Adaptor Collar Momentmodstand"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"277\" class=\"elementor elementor-277\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-292be0b e-flex e-con-boxed e-con e-parent\" data-id=\"292be0b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0f48abd elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"0f48abd\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Luer Lock Adaptor Collar Momentmodstand<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6817f29 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"6817f29\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Forst\u00e5else <strong>luer lock adapter krave moment modstand<\/strong> er afg\u00f8rende for at sikre kvaliteten og p\u00e5lideligheden af forfyldte spr\u00f8jter. Denne test verificerer Luer Lock Adaptor-kravens (LLA) evne til at modst\u00e5 rotationskr\u00e6fter, n\u00e5r en Luer-fitting, som f.eks. en kanylehub, er sat p\u00e5. At sikre, at dine spr\u00f8jter lever op til pr\u00e6stationsstandarderne, handler ikke kun om overholdelse - det handler om at beskytte slutbrugerne og bevare dit brands omd\u00f8mme.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-05adfe7 e-flex e-con-boxed e-con e-parent\" data-id=\"05adfe7\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ecf369e elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ecf369e\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vigtigheden af at teste Luer Lock-adapterkravens momentmodstand<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f390758 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"f390758\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Den <strong>luer lock adapter krave moment modstand<\/strong> testen evaluerer den mekaniske stabilitet af spr\u00f8jtens LLA-krave under vridningsstress. Hvis kraven svigter under eller efter p\u00e5s\u00e6tning af n\u00e5len, kan det resultere i alvorlige konsekvenser som l\u00e6kage, doseringsfejl eller endda personskade.<\/p><p>Ved at udf\u00f8re denne test kan producenterne sikre:<\/p><ul><li>Spr\u00f8jtens mekaniske holdbarhed under klinisk brug.<\/li><li>Overholdelse af internationale kvalitetsstandarder som <a href=\"https:\/\/www.syringetest.com\/da\/iso-11040-4\/\"><strong>ISO 11040-4<\/strong><\/a>.<\/li><li>H\u00f8jere kundetilfredshed og f\u00e6rre tilbagekaldelser af produkter.<\/li><li>Sikrere l\u00e6gemiddeladministration for sundhedspersonale og patienter.<\/li><\/ul><p>Test af denne egenskab er is\u00e6r vigtig for steriliserede, samlede spr\u00f8jter, der er klar til p\u00e5fyldning, for at sikre, at produktet bevarer sin integritet fra fremstilling til administration.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f79c0a e-flex e-con-boxed e-con e-parent\" data-id=\"3f79c0a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ec7f91b elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ec7f91b\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Annex G4 Krav til test af momentmodstand<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64203b6 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"64203b6\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Den <strong>ISO 11040-4 Bilag G4<\/strong> afsnit beskriver specifikt, hvordan man udf\u00f8rer <strong>luer lock adapter krave moment modstand<\/strong> test p\u00e5 en ensartet og standardiseret m\u00e5de. Her er en oversigt over det vigtigste:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c66d4c9 e-n-tabs-mobile elementor-invisible elementor-widget elementor-widget-n-tabs\" data-id=\"c66d4c9\" data-element_type=\"widget\" data-settings=\"{&quot;tabs_justify_horizontal&quot;:&quot;center&quot;,&quot;_animation&quot;:&quot;fadeInUp&quot;,&quot;horizontal_scroll&quot;:&quot;disable&quot;}\" data-widget_type=\"nested-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-tabs\" data-widget-number=\"208065737\" aria-label=\"Faner. \u00c5bn elementer med Enter eller Space, luk med Escape, og naviger med piletasterne.\">\n\t\t\t<div class=\"e-n-tabs-heading\" role=\"tablist\">\n\t\t\t\t\t<button id=\"e-n-tab-title-2080657371\" class=\"e-n-tab-title\" aria-selected=\"true\" data-tab-index=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"e-n-tab-content-2080657371\" style=\"--n-tabs-title-order: 1;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tPrincip\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-2080657372\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-2080657372\" style=\"--n-tabs-title-order: 2;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tMaterialer og udstyr\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-2080657373\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-2080657373\" style=\"--n-tabs-title-order: 3;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tForberedelse af testpr\u00f8ver\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t\t<\/div>\n\t\t\t<div class=\"e-n-tabs-content\">\n\t\t\t\t<div id=\"e-n-tab-content-2080657371\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-2080657371\" data-tab-index=\"1\" style=\"--n-tabs-title-order: 1;\" class=\"e-active elementor-element elementor-element-661f178 e-con-full e-flex e-con e-child\" data-id=\"661f178\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-45c637c elementor-widget elementor-widget-text-editor\" data-id=\"45c637c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Metoden vurderer, om LLA-kraven kan modst\u00e5 en rotationskraft, der p\u00e5f\u00f8res under tilslutning af en Luer-fitting. Kraven skal forblive sikker uden overdreven bev\u00e6gelse eller l\u00f8srivelse.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-2080657372\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-2080657372\" data-tab-index=\"2\" style=\"--n-tabs-title-order: 2;\" class=\"elementor-element elementor-element-8d83155 e-con-full e-flex e-con e-child\" data-id=\"8d83155\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1bab19a elementor-widget elementor-widget-text-editor\" data-id=\"1bab19a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Testpr\u00f8ver<\/strong>: Steriliserede, samlede spr\u00f8jter, der er klar til at blive fyldt med LLA.<\/li><li><strong>Momenttester<\/strong>: Udstyret med en rotationsenhed, der kan rotere 20 gange i minuttet.<\/li><li><strong>Moment-sensor<\/strong>: 35 Ncm kapacitet med 0,05 Ncm opl\u00f8sning.<\/li><li><strong>Pr\u00f8veudtagningshastighed<\/strong>: 500 Hz anbefales til spidsbelastningsm\u00e5linger.<\/li><\/ul><p>Det er vigtigt at bruge kalibreret udstyr for at sikre m\u00e5lingernes n\u00f8jagtighed. Syringetest.com's l\u00f8sninger til test af drejningsmoment giver h\u00f8je samplingshastigheder og p\u00e5lidelig dataindsamling for at opfylde disse behov.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-2080657373\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-2080657373\" data-tab-index=\"3\" style=\"--n-tabs-title-order: 3;\" class=\"elementor-element elementor-element-bc03100 e-flex e-con-boxed e-con e-child\" data-id=\"bc03100\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5d48674 elementor-widget elementor-widget-text-editor\" data-id=\"5d48674\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Testpr\u00f8ver skal h\u00e5ndteres under samme forhold som det endelige produkt. Konsistens sikrer, at testresultaterne n\u00f8jagtigt afspejler den virkelige verdens ydeevne.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6abe7ae e-flex e-con-boxed e-con e-parent\" data-id=\"6abe7ae\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea29382 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ea29382\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Trin-for-trin testprocedure<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ddce5ee elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"ddce5ee\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Udf\u00f8relse af en <strong>luer lock adapter krave moment modstand<\/strong> test i henhold til <strong>ISO 11040-4 Bilag G4<\/strong> involverer f\u00f8lgende trin:<\/p><ol><li><strong>Ops\u00e6tning af pr\u00f8ve<\/strong>: S\u00e6t den steriliserede spr\u00f8jte lodret ind i spr\u00f8jteholderen.<\/li><li><strong>Fjernelse af spidsd\u00e6ksel<\/strong>: Fjern forsigtigt spidsd\u00e6kslet manuelt for at undg\u00e5 at p\u00e5f\u00f8re et for h\u00f8jt moment.<\/li><li><strong>Montering af griber<\/strong>: S\u00e6t LLA-halsb\u00e5ndsgriberen godt fast p\u00e5 halsb\u00e5ndet.<\/li><li><strong>Nulstilling<\/strong>: Indstil momentsensoren til nul uden at p\u00e5f\u00f8re noget indledende moment.<\/li><li><strong>Rotationshastighed<\/strong>: Juster rotationen til 20 omdrejninger pr. minut (eller som aftalt med kunden).<\/li><li><strong>Test start<\/strong>: Drej pladespilleren 90\u00b0 med eller mod uret, eller drej selve lukningen.<\/li><li><strong>Registrering af maksimalt drejningsmoment<\/strong>: Registrer det maksimale drejningsmoment i det \u00f8jeblik, hvor kraven begynder at rotere.<\/li><\/ol><p>Det maksimalt registrerede drejningsmoment repr\u00e6senterer kravenes modstand mod rotationskraft og skal opfylde de specifikationer, der er defineret i produktstandarderne.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-55047da e-con-full e-flex e-con e-child\" data-id=\"55047da\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-45cda6a eael-infobox-content-align--left elementor-widget__width-initial eael-infobox-icon-bg-shape-none eael-infobox-icon-hover-bg-shape-none elementor-invisible elementor-widget elementor-widget-eael-info-box\" data-id=\"45cda6a\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInLeft&quot;}\" data-widget_type=\"eael-info-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-infobox icon-on-top\">\n\t            <div class=\"infobox-icon eael-icon-only\">\n\n            \n                            <div class=\"infobox-icon-wrap\">\n                                    <\/div>\n            \n            \n        <\/div>\n            <div class=\"infobox-content eael-icon-only\">\n                    <div class=\"infobox-title-section\">\n                <h3 class=\"title\">Udtryk og rapportering af testresultater<\/h3>            <\/div>\n            <div><p>N\u00e5r du har gennemf\u00f8rt testen, er det vigtigt at dokumentere:<\/p><ul><li>Den m\u00e5lte maksimale drejningsmomentv\u00e6rdi (i Ncm).<\/li><li>Den anvendte rotationshastighed.<\/li><li>Antallet af testede og godkendte pr\u00f8ver.<\/li><li>Eventuelle observerede afvigelser eller uregelm\u00e6ssigheder.<\/li><\/ul><p>Sporbarhed er afg\u00f8rende. Selv om nogle ops\u00e6tningsparametre ikke udskrives automatisk, skal de logges manuelt for at opretholde fuld sporbarhed.<\/p><\/div>        <\/div>\n            <\/div>\n\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fda7334 e-con-full e-flex e-con e-child\" data-id=\"fda7334\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a601c24 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-image\" data-id=\"a601c24\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInRight&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"330\" height=\"320\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp\" class=\"attachment-large size-large wp-image-280\" alt=\"Luer Lock Adaptor Collar Torque Resistance - ISO 11040-4 Annex G4\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp 330w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4-300x291.webp 300w\" sizes=\"(max-width: 330px) 100vw, 330px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b581cc e-con-full e-flex e-con e-parent\" data-id=\"1b581cc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-61afd37 e-grid e-con-full e-con e-child\" data-id=\"61afd37\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-f8ace73 e-con-full e-flex elementor-invisible e-con e-child\" data-id=\"f8ace73\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;animation&quot;:&quot;fadeInLeft&quot;}\">\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94cc5ad e-flex e-con-boxed elementor-invisible e-con e-child\" data-id=\"94cc5ad\" data-element_type=\"container\" data-settings=\"{&quot;animation&quot;:&quot;fadeInRight&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-907b713 elementor-widget elementor-widget-heading\" data-id=\"907b713\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvorfor v\u00e6lge <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-718f32f elementor-widget elementor-widget-text-editor\" data-id=\"718f32f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Hos Syringetest.com forst\u00e5r vi, at p\u00e5lidelig <strong>luer lock adapter krave moment modstand<\/strong> Test er afg\u00f8rende for dine spr\u00f8jteprodukters succes. Vi tilbyder momenttestere med h\u00f8j pr\u00e6cision, der opfylder eller overg\u00e5r kravene i <strong>ISO 11040-4<\/strong> og <strong>ISO 11040-4 Bilag G4<\/strong>. Vores instrumenter er udstyret med:<\/p><ul><li><strong>H\u00f8je samplingshastigheder<\/strong> for bedre topn\u00f8jagtighed.<\/li><li><strong>Brugervenlig software<\/strong> med komplet testdokumentation.<\/li><li><strong>Armaturer, der kan tilpasses<\/strong> s\u00e5 de passer til forskellige spr\u00f8jtedesigns.<\/li><\/ul><p>Desuden st\u00f8tter vi vores kunder med teknisk ekspertise og tilpasning af automatisering, s\u00e5 vi sikrer, at dine testworkflows er effektive, n\u00f8jagtige og i overensstemmelse med reglerne.<\/p><p>Testning <strong>luer lock adapter krave moment modstand<\/strong> if\u00f8lge <strong>ISO 11040-4 Bilag G4<\/strong> er ikke blot en lovgivningsm\u00e6ssig formalitet - det er et kritisk kvalitetskontroltrin, der sikrer produktsikkerhed, p\u00e5lidelighed og brugertilfredshed. Med det rigtige udstyr og de rigtige testmetoder kan du trygt sende sikre og kompatible spr\u00f8jteprodukter p\u00e5 markedet.<\/p><p>Hvis du har brug for hj\u00e6lp til at ops\u00e6tte dine momentmodstandstests eller v\u00e6lge de rigtige testinstrumenter, <strong>Syringetest.com<\/strong> er her for at hj\u00e6lpe. Kontakt os i dag for at f\u00e5 mere at vide om vores l\u00f8sninger, der er skr\u00e6ddersyet til dine behov for spr\u00f8jtetest.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f735b94 elementor-widget elementor-widget-eael-creative-button\" data-id=\"f735b94\" data-element_type=\"widget\" data-widget_type=\"eael-creative-button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"eael-creative-button-wrapper\">\n\n            <a class=\"eael-creative-button eael-creative-button--default\" href=\"#\" data-text=\"Contact Us\">\n\n\t    \n                <div class=\"creative-button-inner\">\n\n                    \n                    <span class=\"cretive-button-text\">Kontakt os<\/span>\n\n                                    <\/div>\n\t                        <\/a>\n        <\/div>\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Adaptor Collar Torque Resistance Understanding luer lock adaptor collar torque resistance is critical for ensuring the quality and reliability of prefilled syringe assemblies. This test verifies the ability of the Luer Lock Adaptor (LLA) collar to resist rotational forces when a Luer fitting, such as a needle hub, is attached. Ensuring that your [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-277","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Luer Lock Adaptor Collar Torque Resistance - ISO 11040-4 Annex G4<\/title>\n<meta name=\"description\" content=\"Conduct the luer lock adaptor collar torque resistance test following ISO 11040-4 and Annex G4 standards, ensuring syringe assembly quality.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.syringetest.com\/da\/luer-lock-adaptor-collar-torque-resistance\/\" \/>\n<meta property=\"og:locale\" content=\"da_DK\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Luer Lock Adaptor Collar Torque Resistance - ISO 11040-4 Annex G4\" \/>\n<meta property=\"og:description\" content=\"Conduct the luer lock adaptor collar torque resistance test following ISO 11040-4 and Annex G4 standards, ensuring syringe assembly quality.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.syringetest.com\/da\/luer-lock-adaptor-collar-torque-resistance\/\" \/>\n<meta property=\"og:site_name\" content=\"Syringe and Needle Testing\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-06T06:34:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"330\" \/>\n\t<meta property=\"og:image:height\" content=\"320\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimeret l\u00e6setid\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance\",\"url\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance\",\"name\":\"Luer Lock Adaptor Collar Torque Resistance - ISO 11040-4 Annex G4\",\"isPartOf\":{\"@id\":\"https:\/\/www.syringetest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp\",\"datePublished\":\"2025-05-06T05:39:02+00:00\",\"dateModified\":\"2025-05-06T06:34:32+00:00\",\"description\":\"Conduct the luer lock adaptor collar torque resistance test following ISO 11040-4 and Annex G4 standards, ensuring syringe assembly quality.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance#breadcrumb\"},\"inLanguage\":\"da-DK\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance#primaryimage\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.syringetest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Luer Lock Adaptor Collar Torque Resistance\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.syringetest.com\/#website\",\"url\":\"https:\/\/www.syringetest.com\/\",\"name\":\"Syringe and Needle Testing\",\"description\":\"Syringe and Needle Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.syringetest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.syringetest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"da-DK\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.syringetest.com\/#organization\",\"name\":\"Syringe and Needle Testing\",\"url\":\"https:\/\/www.syringetest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"contentUrl\":\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp\",\"width\":512,\"height\":512,\"caption\":\"Syringe and Needle Testing\"},\"image\":{\"@id\":\"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Luer Lock Adaptor Collar Torque Resistance - ISO 11040-4 Annex G4","description":"Conduct the luer lock adaptor collar torque resistance test following ISO 11040-4 and Annex G4 standards, ensuring syringe assembly quality.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.syringetest.com\/da\/luer-lock-adaptor-collar-torque-resistance\/","og_locale":"da_DK","og_type":"article","og_title":"Luer Lock Adaptor Collar Torque Resistance - ISO 11040-4 Annex G4","og_description":"Conduct the luer lock adaptor collar torque resistance test following ISO 11040-4 and Annex G4 standards, ensuring syringe assembly quality.","og_url":"https:\/\/www.syringetest.com\/da\/luer-lock-adaptor-collar-torque-resistance\/","og_site_name":"Syringe and Needle Testing","article_modified_time":"2025-05-06T06:34:32+00:00","og_image":[{"width":330,"height":320,"url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimeret l\u00e6setid":"4 minutter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance","url":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance","name":"Luer Lock Adaptor Collar Torque Resistance - ISO 11040-4 Annex G4","isPartOf":{"@id":"https:\/\/www.syringetest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance#primaryimage"},"image":{"@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance#primaryimage"},"thumbnailUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp","datePublished":"2025-05-06T05:39:02+00:00","dateModified":"2025-05-06T06:34:32+00:00","description":"Conduct the luer lock adaptor collar torque resistance test following ISO 11040-4 and Annex G4 standards, ensuring syringe assembly quality.","breadcrumb":{"@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance#breadcrumb"},"inLanguage":"da-DK","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance"]}]},{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance#primaryimage","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Luer-Lock-Adaptor-Collar-Torque-Resistance-ISO-11040-4-Annex-G4.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.syringetest.com\/luer-lock-adaptor-collar-torque-resistance#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.syringetest.com\/"},{"@type":"ListItem","position":2,"name":"Luer Lock Adaptor Collar Torque Resistance"}]},{"@type":"WebSite","@id":"https:\/\/www.syringetest.com\/#website","url":"https:\/\/www.syringetest.com\/","name":"Syringe and Needle Testing","description":"Syringe and Needle Test Solutions","publisher":{"@id":"https:\/\/www.syringetest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.syringetest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"da-DK"},{"@type":"Organization","@id":"https:\/\/www.syringetest.com\/#organization","name":"Syringe and Needle Testing","url":"https:\/\/www.syringetest.com\/","logo":{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","contentUrl":"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/syringetest.webp","width":512,"height":512,"caption":"Syringe and Needle Testing"},"image":{"@id":"https:\/\/www.syringetest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages\/277","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/comments?post=277"}],"version-history":[{"count":5,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages\/277\/revisions"}],"predecessor-version":[{"id":286,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages\/277\/revisions\/286"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/media?parent=277"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}