{"id":265,"date":"2025-05-06T03:29:29","date_gmt":"2025-05-06T03:29:29","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=265"},"modified":"2026-05-09T06:39:48","modified_gmt":"2026-05-09T06:39:48","slug":"luer-lock-adaptor-collar-pull-off-force","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/da\/luer-lock-adaptor-collar-pull-off-force","title":{"rendered":"Luer Lock Adaptor Collar Pull-Off Force"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"265\" class=\"elementor elementor-265\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0ebe6b e-flex e-con-boxed e-con e-parent\" data-id=\"c0ebe6b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d6d91c9 elementor-widget elementor-widget-heading\" data-id=\"d6d91c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Luer Lock Adaptor Collar Pull-Off Force<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0a5f59 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"f0a5f59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>I den farmaceutiske industri og industrien for medicinsk udstyr er det afg\u00f8rende at sikre integriteten af spr\u00f8jtens komponenter. Et vigtigt kvalitetstjek er denne test. Denne evaluering m\u00e5ler styrken af forbindelsen mellem Luer lock-adapterens (LLA) krave og spr\u00f8jtens cylinder, hvilket forhindrer komponentadskillelse under brug.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7e51b6e e-flex e-con-boxed e-con e-parent\" data-id=\"7e51b6e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a359504 elementor-widget elementor-widget-heading\" data-id=\"a359504\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vigtigheden af test af Luer Lock-adapterkravens udtr\u00e6kningskraft<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de744c7 elementor-widget elementor-widget-text-editor\" data-id=\"de744c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Hvis aftr\u00e6kningskraften p\u00e5 Luer Lock-adapterkraven er for lav, kan kraven l\u00f8sne sig fra spr\u00f8jten under h\u00e5ndtering eller injektion, hvilket kan f\u00f8re til medicinl\u00e6kage, ufuldst\u00e6ndig dosering eller endda alvorlig patientskade. P\u00e5 den anden side, hvis kraften er for h\u00f8j, kan samleprocesser blive vanskelige, hvilket \u00f8ger risikoen for skader under fremstillingen.<\/p><p>Derfor er det vigtigt at udf\u00f8re standardiserede tests for at sikre, at kraven sidder godt fast, opretholde spr\u00f8jtens funktionsdygtighed og beskytte patientsikkerheden.<\/p><p><strong>Syringetest.com<\/strong> tilbyder pr\u00e6cist og p\u00e5lideligt testudstyr til <em>Luer lock-adapterkravens aftr\u00e6kningskraft<\/em> og hj\u00e6lper med at sikre, at dine spr\u00f8jter med sikkerhed opfylder globale kvalitetsstandarder.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f3ad5f2 e-flex e-con-boxed e-con e-parent\" data-id=\"f3ad5f2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d69bf22 elementor-widget elementor-widget-heading\" data-id=\"d69bf22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 og ISO 11040-4 bilag G3<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c32614c e-con-full e-flex e-con e-child\" data-id=\"c32614c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fcd1b36 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"fcd1b36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Den <a href=\"https:\/\/www.syringetest.com\/da\/standards\/iso-11040-4\/\"><em>ISO 11040-4<\/em><\/a> standard, is\u00e6r <em>ISO 11040-4 Bilag G3<\/em>beskriver proceduren for <em>Luer lock-adapterkravens aftr\u00e6kningskraft<\/em> test. I henhold til disse standarder verificerer aftr\u00e6kningskrafttesten kravesystemets evne til at modst\u00e5 aksiale kr\u00e6fter, hvilket sikrer, at spr\u00f8jter forbliver intakte under kritiske operationer som f.eks. medicinadministration. Metoden l\u00e6gger v\u00e6gt p\u00e5 ensartede testhastigheder, passende valg af belastningsceller og h\u00f8jfrekvent pr\u00f8veudtagning for at sikre n\u00f8jagtige og p\u00e5lidelige data.<\/p><p>F\u00f8lgende <em>ISO 11040-4 Bilag G3<\/em> forbedrer testkonsistensen p\u00e5 tv\u00e6rs af laboratorier og producenter, hvilket fremmer tilliden til produktkvalitet og overholdelse af lovgivningen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0502b44 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"0502b44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"515\" height=\"350\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp\" class=\"attachment-medium_large size-medium_large wp-image-272\" alt=\"Luer Lock Adaptor Collar Pull-Off Force - ISO 11040-4 Annex G3\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing.webp 515w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/05\/Needle-Bonding-Strength-Test-Syringe-Needle-Testing-300x204.webp 300w\" sizes=\"(max-width: 515px) 100vw, 515px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c33ea3f e-flex e-con-boxed e-con e-parent\" data-id=\"c33ea3f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b8731e5 elementor-widget elementor-widget-heading\" data-id=\"b8731e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Princippet i Luer Lock Adaptor Collar Pull-Off Force Test<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-931bcc4 elementor-widget elementor-widget-text-editor\" data-id=\"931bcc4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Kerneid\u00e9en bag denne test er enkel: Den m\u00e5ler den maksimale aksiale kraft, der kr\u00e6ves for at l\u00f8sne LLA-kraven fra spr\u00f8jtens cylinder. En st\u00e6rk aftr\u00e6kningskraft betyder, at LLA-kraven er sikkert fastgjort, hvilket minimerer risikoen for frakobling under brug.<\/p><p>N\u00f8gleprincippet fokuserer p\u00e5:<\/p><ul><li>Simulering af realistisk mekanisk belastning.<\/li><li>Sikrer, at indf\u00f8ringskr\u00e6fter fra standard Luer-fittings ikke f\u00e5r kraven til at l\u00f8sne sig.<\/li><li>Indsamling af spidskraftdata gennem analyse af kraft i forhold til forskydning.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cbb1f00 e-flex e-con-boxed e-con e-parent\" data-id=\"cbb1f00\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9e34cbf elementor-widget elementor-widget-heading\" data-id=\"9e34cbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">N\u00f8dvendigt udstyr og materialer<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29c5058 elementor-widget elementor-widget-text-editor\" data-id=\"29c5058\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>N\u00f8jagtig test af <em>Luer lock-adapterkravens aftr\u00e6kningskraft<\/em> kr\u00e6ver pr\u00e6cisionsudstyr:<\/p><ul><li><strong>Universal tr\u00e6k- og trykpr\u00f8vemaskine <\/strong>med:<ul><li>Testhastighed indstillet til 20 mm\/min (i henhold til ISO 80369-7, hvis det er relevant).<\/li><li>Vejecelle egnet til kraftomr\u00e5de p\u00e5 10 N til 100 N.<\/li><\/ul><\/li><li><strong>Spr\u00f8jteholder og gribeanordning<\/strong> der fastg\u00f8r b\u00e5de spr\u00f8jtet\u00f8nden og LLA-kraven uden at ud\u00f8ve u\u00f8nsket tryk.<\/li><\/ul><p><strong>Materialer:<\/strong><\/p><ul><li>Steriliserede, samlede spr\u00f8jter klar til p\u00e5fyldning, inklusive LLA-systemet.<\/li><\/ul><p><strong>Det er vigtigt:<\/strong><br \/>Samplingsfrekvensen skal v\u00e6re mindst 100 Hz for generelle tests og 500 Hz for spidsbelastningsm\u00e5linger, hvilket sikrer fin dataopl\u00f8sning og n\u00f8jagtighed.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-61d3079 e-flex e-con-boxed e-con e-parent\" data-id=\"61d3079\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bd94a54 elementor-widget elementor-widget-heading\" data-id=\"bd94a54\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testprocedure for aftr\u00e6kningskraft p\u00e5 Luer Lock-adapterkrave<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc41e63 elementor-widget elementor-widget-text-editor\" data-id=\"fc41e63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ved at udf\u00f8re denne test korrekt sikres n\u00f8jagtige, gentagelige resultater:<\/p><h3>1. Forberedelse af pr\u00f8ver<\/h3><p>Brug spr\u00f8jter, der har gennemg\u00e5et den fulde steriliserings- og klarg\u00f8ringsproces.<\/p><h3>2. Ops\u00e6tning<\/h3><ul><li>Fjern forsigtigt spidsd\u00e6kslet.<\/li><li>Fastg\u00f8r spr\u00f8jten lodret mellem holderen (fingerflangen) og griberen (LLA-kraven) uden at belaste kraven.<\/li><\/ul><h3>3. Udf\u00f8relse af test<\/h3><ul><li>Indstil vejecellen til nul og s\u00f8rg for, at der ikke er nogen forsp\u00e6nding.<\/li><li>P\u00e5f\u00f8r en tr\u00e6kkraft p\u00e5 20 mm\/min.<\/li><li>Registrer l\u00f8bende kurven for kraft versus forskydning.<\/li><\/ul><h3>4. Afslutning af testen<\/h3><p>Stop testen, n\u00e5r LLA-kraven tydeligt l\u00f8sner sig fra spr\u00f8jten.<\/p><h3>5. Optagelse af resultat<\/h3><p>Den maksimale kraftspids p\u00e5 kurven repr\u00e6senterer <em>aftr\u00e6kningskraft<\/em>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc4abbc e-grid e-con-full e-con e-parent\" data-id=\"dc4abbc\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99d351b elementor-widget elementor-widget-image\" data-id=\"99d351b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ccc877e e-con-full e-flex e-con e-child\" data-id=\"ccc877e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef33af7 elementor-widget elementor-widget-heading\" data-id=\"ef33af7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvorfor v\u00e6lge <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b43d751 elementor-widget elementor-widget-text-editor\" data-id=\"b43d751\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"203\" data-end=\"463\">P\u00e5 <strong>Syringetest.com<\/strong>Vi samler ekspertise, innovation, fra pr\u00e6cis teknik til personlig service for at st\u00f8tte vores kunder over hele verden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28e0c7c elementor-widget elementor-widget-text-editor\" data-id=\"28e0c7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Udf\u00f8relse af <em>Luer lock-adapterkravens aftr\u00e6kningskraft<\/em> test i henhold til <em>ISO 11040-4 Bilag G3<\/em> er afg\u00f8rende for at sikre den mekaniske sikkerhed af Luer lock-spr\u00f8jter. Korrekt udf\u00f8relse og dokumentation giver sikkerhed for, at spr\u00f8jterne kan modst\u00e5 belastningerne ved klinisk brug uden at svigte.<br \/>Stol p\u00e5 <strong>Syringetest.com<\/strong> for banebrydende testl\u00f8sninger, der h\u00f8jner kvaliteten og sikkerheden af dine spr\u00f8jteprodukter.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5463cac elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"5463cac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/da\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt os<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Lock Adaptor Collar Pull-Off Force In the pharmaceutical and medical device industries, ensuring the integrity of syringe components is critical. One essential quality check is the this test. This evaluation measures the strength of the connection between the Luer lock adaptor (LLA) collar and the syringe barrel, preventing component separation during use. The Importance [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-265","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages\/265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/comments?post=265"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages\/265\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/media?parent=265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}