{"id":247,"date":"2025-05-06T02:59:16","date_gmt":"2025-05-06T02:59:16","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=247"},"modified":"2026-05-14T08:15:29","modified_gmt":"2026-05-14T08:15:29","slug":"needle-tubing-stiffness-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/da\/needle-tubing-stiffness-test","title":{"rendered":"Stivhedstest af n\u00e5leslanger"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"247\" class=\"elementor elementor-247\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1e601d7 e-flex e-con-boxed e-con e-parent\" data-id=\"1e601d7\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0e5a4e8 elementor-widget elementor-widget-heading\" data-id=\"0e5a4e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Stivhedstest af n\u00e5leslanger<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-307f5d3 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"307f5d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Den <strong>Stivhedstest af n\u00e5leslanger<\/strong> spiller en afg\u00f8rende rolle for at sikre medicinsk udstyrs ydeevne og sikkerhed, is\u00e6r injektionsn\u00e5le. Denne test bestemmer, hvor modstandsdygtige slanger af rustfrit st\u00e5l er over for b\u00f8jning, n\u00e5r de uds\u00e6ttes for en standardiseret kraft. For fagfolk i industrien for medicinsk udstyr - is\u00e6r dem, der er involveret i kvalitetssikring af spr\u00f8jter - er det vigtigt at forst\u00e5 denne test for at opfylde lovm\u00e6ssige standarder og sikre patientsikkerheden.<\/p><p>Syringetest.com tilbyder h\u00f8jpr\u00e6cisionsl\u00f8sninger til udf\u00f8relse af stivhedstest af kanyleslanger og sikrer, at dine produkter overholder globale standarder som f.eks. <strong>ISO 9626<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5684a6e e-flex e-con-boxed e-con e-parent\" data-id=\"5684a6e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-02d54a2 elementor-widget elementor-widget-heading\" data-id=\"02d54a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 9626 og ISO 9626 Annex B<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b9bcb4 e-con-full e-flex e-con e-child\" data-id=\"1b9bcb4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c55fa1a elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"c55fa1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.syringetest.com\/da\/standards\/iso-9626\/\"><strong>ISO 9626<\/strong><\/a>, med titlen <em>N\u00e5leslanger af rustfrit st\u00e5l til fremstilling af medicinsk udstyr - Krav og pr\u00f8vningsmetoder<\/em>fasts\u00e6tter de fysiske og mekaniske kriterier for slanger af rustfrit st\u00e5l, der anvendes i medicinsk udstyr. Blandt de vigtigste komponenter, <strong>ISO 9626 Bilag B<\/strong> giver en detaljeret metode til at udf\u00f8re <strong>Stivhedstest af n\u00e5leslanger<\/strong>og tilbyder strenge procedurekrav og udstyrsspecifikationer.<\/p><p>Bilag B beskriver, hvordan man vurderer stivheden ved at anvende en <strong>specificeret kraft<\/strong> til midten af slangen, der er underst\u00f8ttet i begge ender, og m\u00e5le <strong>resulterende afb\u00f8jning<\/strong>. Denne proces hj\u00e6lper med at vurdere, om slangen har den n\u00f8dvendige mekaniske styrke til at modst\u00e5 brug i den virkelige verden uden at b\u00f8je eller g\u00e5 i stykker.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25a7788 elementor-widget elementor-widget-image\" data-id=\"25a7788\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"590\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard.webp\" class=\"attachment-large size-large wp-image-99\" alt=\"Teststandard for l\u00f8srivelse og glidekraft\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard.webp 600w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/break-loose-and-glide-force-testing-standard-300x295.webp 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd39b91 e-con-full e-flex e-con e-child\" data-id=\"fd39b91\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-315872e elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"315872e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Testprincip og betydning<\/h3><p>Det centrale princip i <strong>Stivhedstest af n\u00e5leslanger<\/strong> er ligetil: En fast nedadg\u00e5ende kraft p\u00e5f\u00f8res midten af n\u00e5leslangen, som er vandret underst\u00f8ttet i begge ender. Den <strong>m\u00e6ngden af afb\u00f8jning<\/strong> p\u00e5 det sted, hvor kraften p\u00e5f\u00f8res, angiver slangens stivhed.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0b91159 elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"0b91159\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Hvorfor er det vigtigt?<\/h3><ul><li><strong>Produktsikkerhed:<\/strong> Undg\u00e5 b\u00f8jning eller brud under injektion.<\/li><li><strong>Konsistens i produktionen:<\/strong> S\u00f8rg for, at hvert parti opfylder de samme mekaniske standarder.<\/li><li><strong>Overholdelse af lovgivningen:<\/strong> M\u00f8des <strong>ISO 9626<\/strong> certificering til global markedsadgang.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2176b2b e-flex e-con-boxed e-con e-parent\" data-id=\"2176b2b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0601f88 elementor-widget elementor-widget-heading\" data-id=\"0601f88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">N\u00f8dvendigt udstyr til stivhedstest af n\u00e5leslanger<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91dcc43 elementor-widget elementor-widget-text-editor\" data-id=\"91dcc43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>For at udf\u00f8re testen i henhold til <strong>ISO 9626 Bilag B<\/strong>er f\u00f8lgende apparatur n\u00f8dvendigt:<\/p><h3>Apparat til test af stivhed<\/h3><p class=\"\" data-start=\"2125\" data-end=\"2247\">I stand til at p\u00e5f\u00f8re op til <strong>60 N<\/strong> af kraft med en n\u00f8jagtighed p\u00e5 <strong>\u00b10.1 N<\/strong>med en <strong>stump kileformet stempel<\/strong>. Kilen skal best\u00e5 af to flade overflader, der h\u00e6lder med <strong>60\u00b0<\/strong>, gennemsk\u00e5ret af en cylindrisk overflade med en <strong>1 mm radius<\/strong>.<\/p><h3 data-start=\"2125\" data-end=\"2247\">Enhed til m\u00e5ling af afb\u00f8jning<\/h3><p class=\"\" data-start=\"2755\" data-end=\"3082\">N\u00f8jagtig til <strong>0,01 mm<\/strong>bruges til at registrere, hvor meget slangen b\u00f8jer under den p\u00e5f\u00f8rte kraft.<\/p><p>Syringetest.com leverer tilpassede testinstrumenter, der fuldt ud opfylder disse tekniske krav, og hj\u00e6lper laboratorier og producenter med at implementere standardiserede og gentagelige testprocesser.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-512b05c e-flex e-con-boxed e-con e-parent\" data-id=\"512b05c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-820f2d6 elementor-widget elementor-widget-heading\" data-id=\"820f2d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testprocedure for stivhed af n\u00e5leslanger<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9839f71 elementor-widget elementor-widget-text-editor\" data-id=\"9839f71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>1. Placering af pr\u00f8ve<\/h3><p>Anbring slangen p\u00e5 testapparatet. S\u00f8rg for det:<\/p><ul><li>Den <strong>sp\u00e6ndvidde<\/strong> svarer til v\u00e6rdierne i ISO 9626 tabel 2 for den givne slangest\u00f8rrelse.<\/li><li>Den <strong>Stempel<\/strong> er centreret.<\/li><li>Slangen er orienteret <strong>vinkelret<\/strong> til b\u00e5de stemplet og st\u00f8ttepunkterne.<\/li><\/ul><h3>2. Anvendelse af kraft<\/h3><p>P\u00e5f\u00f8r den nedadg\u00e5ende kraft som specificeret for slangest\u00f8rrelsen med en kontrolleret hastighed p\u00e5 <strong>1 mm\/min til 10 mm\/min<\/strong>.<\/p><h3>3. M\u00e5ling af afb\u00f8jning<\/h3><p>M\u00e5l og registrer <strong>afb\u00f8jning<\/strong> af slangen i midten med en n\u00f8jagtighed p\u00e5 <strong>\u00b10,01 mm<\/strong>.<\/p><h3>4. Rapportering af resultater<\/h3><p>En komplet testrapport skal indeholde:<\/p><ul><li>Slangest\u00f8rrelse og identifikation<\/li><li>Slangetype (RW, TW, ETW, UTW)<\/li><li>M\u00e5lt afb\u00f8jning<\/li><li>Dato for testning<\/li><li>Anvendt legering af rustfrit st\u00e5l<\/li><\/ul><p>Syringetest.com's automatiserede stivhedstestere forenkler denne proces ved at integrere <strong>Pr\u00e6cisionssensorer<\/strong> og <strong>brugervenlige gr\u00e6nseflader<\/strong> for at sikre gentagelighed og sporbarhed af testresultater.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b7a8cd e-grid e-con-full e-con e-parent\" data-id=\"7b7a8cd\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ce47441 elementor-widget elementor-widget-image\" data-id=\"ce47441\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-413684e e-con-full e-flex e-con e-child\" data-id=\"413684e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5ae9222 elementor-widget elementor-widget-heading\" data-id=\"5ae9222\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvorfor v\u00e6lge <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ee84ad elementor-widget elementor-widget-text-editor\" data-id=\"8ee84ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Som en betroet leverand\u00f8r af l\u00f8sninger til materialetestning, <strong>Syringetest.com<\/strong> leverer instrumenter, der opfylder og overg\u00e5r ISO-standarder. Vores stivhedstestere er konstrueret til:<\/p><ul><li><strong>H\u00f8j pr\u00e6cision og p\u00e5lidelighed<\/strong><\/li><li><strong>Brugertilpasning<\/strong> til specielle r\u00f8rst\u00f8rrelser eller legeringstyper<\/li><li><strong>Muligheder for automatisering<\/strong> for at \u00f8ge testeffektiviteten<\/li><li><strong>Datalogning og sporbarhed<\/strong> for revisionsparathed<\/li><\/ul><p>Vi betjener industrier lige fra <strong>medicinsk udstyr og l\u00e6gemidler til kvalitetskontrollaboratorier<\/strong>. Med et st\u00e6rkt fokus p\u00e5 innovation st\u00f8tter vi ogs\u00e5 <strong>Opgraderinger af automatisering<\/strong> og <strong>Udvikling af brugerdefinerede tests<\/strong>.<\/p><p>Den <strong>Stivhedstest af n\u00e5leslanger<\/strong>n\u00e5r det udf\u00f8res korrekt under <strong>ISO 9626 Bilag B<\/strong>sikrer, at medicinske slanger bevarer deres mekaniske integritet under brug. Det handler ikke kun om overholdelse - det handler om <strong>beskytte patienterne og bevare tilliden<\/strong> i medicinske produkter.<\/p><p>Med professionelle testinstrumenter fra <strong>Syringetest.com<\/strong>kan producenterne med sikkerhed sikre produktkvaliteten, opfylde internationale standarder og str\u00f8mline kvalitetskontrolprocesserne.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-383dde0 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"383dde0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/da\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt os<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Needle Tubing Stiffness Test The needle tubing stiffness test plays a critical role in ensuring the performance and safety of medical devices, particularly hypodermic needles. This test determines the resistance of stainless steel tubing to bending when a standardized force is applied. For professionals in the medical device industry\u2014especially those involved in quality assurance of [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-247","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages\/247","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/comments?post=247"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages\/247\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/media?parent=247"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}