{"id":154,"date":"2025-04-30T01:31:34","date_gmt":"2025-04-30T01:31:34","guid":{"rendered":"https:\/\/www.syringetest.com\/?page_id=154"},"modified":"2026-05-09T06:36:31","modified_gmt":"2026-05-09T06:36:31","slug":"finger-flange-breakage-force-test","status":"publish","type":"page","link":"https:\/\/www.syringetest.com\/da\/finger-flange-breakage-force-test","title":{"rendered":"Test af fingerflangens brudstyrke"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"154\" class=\"elementor elementor-154\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-247db7c e-flex e-con-boxed e-con e-parent\" data-id=\"247db7c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab06118 elementor-widget elementor-widget-heading\" data-id=\"ab06118\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Test af fingerflangebrudskraft<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62cf733 elementor-widget elementor-widget-text-editor\" data-id=\"62cf733\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>I den farmaceutiske og medicinske emballageindustri, <strong>fingerflange brudkraft<\/strong> er en kritisk pr\u00e6stationsindikator for at sikre den strukturelle p\u00e5lidelighed af spr\u00f8jtet\u00f8nder. Denne parameter er defineret og standardiseret i <strong><em><a href=\"https:\/\/www.syringetest.com\/da\/standards\/iso-11040-4\/\">ISO 11040-4<\/a> Bilag C1<\/em><\/strong>hj\u00e6lper producenter og kvalitetssikringsfolk med at vurdere, om spr\u00f8jteflangen kan modst\u00e5 mekanisk belastning under h\u00e5ndtering og injektion.<\/p><p>At forst\u00e5 denne m\u00e5ling og dens standardtestmetode er afg\u00f8rende for fagfolk, der er involveret i <strong>Spr\u00f8jtetestning<\/strong>, is\u00e6r til sterile, sammensatte spr\u00f8jter beregnet til injektionsv\u00e6sker.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f136d2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f136d2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b673494 elementor-widget elementor-widget-heading\" data-id=\"b673494\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Betydningen af fingerflangens brudkraft for spr\u00f8jtens integritet<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa819a0 elementor-widget elementor-widget-text-editor\" data-id=\"aa819a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Den <strong>fingerflange brudkraft<\/strong> refererer til den maksimale mekaniske kraft, som flangen p\u00e5 en spr\u00f8jte kan modst\u00e5, f\u00f8r den svigter. Denne v\u00e6rdi angiver spr\u00f8jtens robusthed, is\u00e6r n\u00e5r brugerne l\u00e6gger pres p\u00e5 under injektion, eller n\u00e5r automatiserede fyldesystemer griber fat i spr\u00f8jten.<\/p><p>En utilstr\u00e6kkelig brudkraft kan resultere i revner i flangen eller fuldst\u00e6ndig svigt, hvilket udg\u00f8r en sikkerhedsrisiko. Derfor er det ikke til forhandling at opretholde en ensartet kvalitet p\u00e5 tv\u00e6rs af partier i produktionen af medicinsk udstyr.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-37feff9 e-flex e-con-boxed e-con e-parent\" data-id=\"37feff9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3146496 elementor-widget elementor-widget-heading\" data-id=\"3146496\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test af fingerflanges brudstyrke - ISO 11040-4 Annex C1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08fc359 elementor-widget elementor-widget-text-editor\" data-id=\"08fc359\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Den <strong><a href=\"https:\/\/www.syringetest.com\/da\/standards\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">ISO 11040-4<\/a> Bilag C1<\/strong> beskriver testmetoden til evaluering af modstandsdygtighed over for flangebrud. Proceduren sikrer n\u00f8jagtige, gentagelige resultater, hvilket g\u00f8r den til guldstandarden inden for test af spr\u00f8jters ydeevne.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd10895 e-grid e-con-full e-con e-child\" data-id=\"fd10895\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d98b842 elementor-widget elementor-widget-text-editor\" data-id=\"d98b842\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Testens form\u00e5l<\/h3><p>At bestemme flangens brudstyrke ved at p\u00e5f\u00f8re en nedadg\u00e5ende kraft p\u00e5 spr\u00f8jtens cylinder ved hj\u00e6lp af specialudstyr. Denne test evaluerer b\u00e5de <strong>Styrke p\u00e5 glast\u00f8nde<\/strong> og dens kompatibilitet med resten af spr\u00f8jtedesignet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db58dbc elementor-widget elementor-widget-text-editor\" data-id=\"db58dbc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>N\u00f8dvendigt udstyr<\/h3><ul><li><strong>Universal tr\u00e6k- og trykpr\u00f8vemaskine<\/strong>: Skal omfatte en passende vejecelle og en konfigurerbar testhastighed p\u00e5 <strong>100 mm\/min<\/strong>.<\/li><li><strong>Spr\u00f8jteholder<\/strong>: Typisk fremstillet af PEEK, skr\u00e6ddersyet til spr\u00f8jtens dimensioner.<\/li><li><strong>Indl\u00e6sningsstift<\/strong>: Fremstillet af polyacetal eller rustfrit st\u00e5l, designet til at p\u00e5f\u00f8re kraft ensartet.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a8c15d0 elementor-widget elementor-widget-image\" data-id=\"a8c15d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"202\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-1024x258.webp\" class=\"attachment-large size-large wp-image-163\" alt=\"Test af brudkraft p\u00e5 spr\u00f8jtefingerflange - ISO 11040-4 Annex C1\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-1024x258.webp 1024w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-300x76.webp 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1-768x194.webp 768w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/Syringe-Finger-Flange-Breakage-Force-Test-ISO-11040-4-Annex-C1.webp 1190w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a78210 e-flex e-con-boxed e-con e-parent\" data-id=\"3a78210\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e89a55d elementor-widget elementor-widget-heading\" data-id=\"e89a55d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ops\u00e6tning og udf\u00f8relse af spr\u00f8jtetest<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e8f3f2 elementor-widget elementor-widget-text-editor\" data-id=\"2e8f3f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>For at udf\u00f8re testen som specificeret i <strong>ISO 11040-4-testning<\/strong>skal du f\u00f8lge disse trin:<\/p><h3>1. Forberedelse af pr\u00f8ver<\/h3><p>Undg\u00e5 st\u00f8d eller forkert h\u00e5ndtering af spr\u00f8jtet\u00f8nder f\u00f8r test. Unders\u00f8g holderen og stiften for slitage.<\/p><h3>2. Ops\u00e6tning af udstyr<\/h3><ul><li>S\u00e6t spr\u00f8jten i holderen under flangen.<\/li><li>Just\u00e9r ladestiften, s\u00e5 den ud\u00f8ver kraft i l\u00f8bet af flangens dybde.<\/li><\/ul><h3>3. Udf\u00f8relse af test<\/h3><ul><li>K\u00f8r maskinen ved <strong>100 mm\/min<\/strong>.<\/li><li>Registrer grafen for kraft-forskydning.<\/li><li>Brug en <strong>Samplingshastighed p\u00e5 mindst 500 Hz<\/strong> til registrering af maksimal kraft.<\/li><\/ul><h3>4. Analyse af resultater<\/h3><p>Den maksimale kraft, der observeres f\u00f8r flangesvigt, registreres som <strong>fingerflange brudkraft<\/strong>. ISO 11040-4 Annex C1 specificerer, at denne v\u00e6rdi sammen med testhastighed og pr\u00f8veantal skal rapporteres i den endelige dokumentation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2d148ee e-grid e-con-full e-con e-parent\" data-id=\"2d148ee\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef5e9b3 elementor-widget elementor-widget-image\" data-id=\"ef5e9b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"643\" src=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png\" class=\"attachment-large size-large wp-image-65\" alt=\"\" srcset=\"https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3.png 875w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-300x241.png 300w, https:\/\/www.syringetest.com\/wp-content\/uploads\/2025\/04\/06a8c2a0-image-3-768x617.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f83c119 e-con-full e-flex e-con e-child\" data-id=\"f83c119\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-af86f15 elementor-widget elementor-widget-heading\" data-id=\"af86f15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvorfor v\u00e6lge <b>Syringetest.com?<\/b><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-321653d elementor-widget elementor-widget-text-editor\" data-id=\"321653d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pr\u00e6cis test af flangebrudskraft kr\u00e6ver h\u00f8jtydende instrumenter. P\u00e5 <strong>Syringetest.com<\/strong>tilbyder vi avancerede tr\u00e6k- og trykpr\u00f8vemaskiner, der er skr\u00e6ddersyet til <strong>Spr\u00f8jtetestning<\/strong>fuldt ud i overensstemmelse med <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><em>ISO 11040-4<\/em><\/a>. Vores systemer er udstyret med pr\u00e6cisionsvejeceller, justerbare hastigheder og intuitiv software til datavisualisering og -eksport i realtid.<\/p><p>Vi tilbyder ogs\u00e5 <strong>Tilpassede spr\u00f8jteholdere og integration af automatisering<\/strong>og hj\u00e6lper med at str\u00f8mline testning i produktionsmilj\u00f8er med h\u00f8j kapacitet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-262c330 elementor-widget__width-auto elementor-align-left elementor-widget elementor-widget-button\" data-id=\"262c330\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.syringetest.com\/da\/contact-us\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt os<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Finger Flange Breakage Force Testing In the pharmaceutical and medical packaging industry, finger flange breakage force is a critical performance indicator for ensuring the structural reliability of syringe barrels. This parameter, defined and standardized in ISO 11040-4 Annex C1, helps manufacturers and quality assurance professionals assess whether the syringe flange can withstand mechanical stress during [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-154","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages\/154","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/comments?post=154"}],"version-history":[{"count":0,"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/pages\/154\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.syringetest.com\/da\/wp-json\/wp\/v2\/media?parent=154"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}